Text

r MATER *At TPAN5?'iiTED HEREWITH

.

CONTAlh5 2.793 IlJORMATCN

d o

UNITED STATES

! " ;3,

NUCLEAR REGULATORY COMMISSION

o e REGION 11 g

o,

!

101 MARIETTA sT N.W.. SUITE 3100 I

p

ATLANTA, G EORGI A 3o303

.....

OCT 011980 Report No. 50-302/80-35 Docket No. 50-302 License No. DPR-12 Licensee: Florida Power Corporation 3201 34th Street, South St. Petersburg, Florida 33733 Facility Name: Crystal River Unit 3 Inspection at: Crystal River, Florida Inspection conducted: September 14-17, 1980 Date of Last Physical Security Inspection Visit: July 7-11, 1980 Type of Inspection: Unannounced Physical Security Inspecto C C ) 7 W Nhc D. E. Moore, Security Inspector Dats Approved by:

)_

a

[Date

D. R. McGuire, Chief, Security Section Inspection Summary Areas Inspected: Included review of security organization, vital area physical barriers; access control (identification, authorization, badging and search);

testing and maintenance; lighting and followup on previous enforcement raatters.

The inspection involved 28 inspector hours on site by one NRC inspector. The inspection was begun during an offshift period; 4 inspection hours were accom-plished during offshift periods.

Results:

Of the seven areas examined during the inspection, three apparent items of noncompliance were identified in three areas.

1.

Physical Barriers - Two sections of vital area barrier not constructed of required material (80-35-01).

2.

Access Control - Failure to search hand-carried packages entering the protected area (80-35-02).

3.

Testing & Maintenance - Failure to provide documented evidence of quarterly personnel evaluation of equipment use performance (80-35-03).