IR 05000302/1980029
| ML19343A271 | |
| Person / Time | |
|---|---|
| Site: | Crystal River |
| Issue date: | 08/04/1980 |
| From: | Gillespie F, Howell J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | |
| Shared Package | |
| ML19343A269 | List: |
| References | |
| 50-302-80-29, NUDOCS 8009170152 | |
| Download: ML19343A271 (1) | |
Text
.
.
5-y2TERIA!.TP).T.iiTT'D EEr3?iTH
-
( s) spur 0 CONTAIK3 2.7031Nf0P.EilSH
y#
9'o UNITED STATES
.
j 8'
NUCLEAR REGULATORY COMMISSION s
A() 3 i REGION 11 o
'
f o
101 MARIETTA ST., N.W., SUITE 3100
- (/w ATLANTA, GEORGIA 30303
.....
AUG 0 51980 Report No. 50-302/80-29
.
Docket No. 50-302
.
License No. DPR-72 5-T2 %
W-
~
Licensee: Florida Power Corporation Copy of Ccpies P. O. Box 14042 Mail Stop C-4
Pc885 St. Petersburg, FL 31733 This Dccuror.t is not to be repreduced without specific Facility Name: Crystal River bait 3 approval of IE8II Inspection at: Crystal River, Florida Inspection conducted: July 7-11, 1980 Date of Last Physical Security Inspection Visit: February 25-28, 1980 Type of Inspectio Un unce hysical Security Inspector:
_
efl! hys cal Security Inspector Date Signed I-7- 8C)
. C.
Approved by: [
i>
d bN~W F. P. Gillespie, Apting Chief, Security and Date Signed
_
Investigation Section, Safeguards Branch Inspection Summary Areas Inspected: Included review of the security program audit, security organi-zation, protected / vital area physical barriers, lighting, access controls (iden-tification, authorization and badging; search; and vital areas), alarm stations, detection aids, power supply, and response.
The inspect. ion involved 37 inspector hours on site by one NRC inspector. The inspection was begun during an offshift period; 10 inspection hours were accomp-lished during offshift periods.
Results: The licensee was found to be in compliance with NRC requirements within the areas examined during this inspection except for the following two items:
1.
Detection Aids - Tamper indicating capability could not be demonstrated for the entire alarm system (Infraction, 80-29-01).
i l
2.
Response - Required security emergency drills were not conducted (Infraction, l
80-29-02).
!
800917o ME FATERlatTRANSMiTTED HEREVi!Til CONTAINS 2.793 IXFORMATION
- _ _