IE Insp Repts 50-280/79-06 & 50-281/79-06 on 790115-19.No Noncompliance Noted.Major Areas Inspected:Steam Generator Repair/Replacement Program & QA Program Including Organizational & Functional Alignment
ML18113A954
Person / Time
Site: Surry  
Issue date: 02/14/1979
From: Brownlee V, Cantrell F, Elrod S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML18113A953 List:
References
50-280-79-06, 50-280-79-6, 50-281-79-06, 50-281-79-6, NUDOCS 7903280026
Download: ML18113A954 (4)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTA STREET, ATLANTA, GEORGIA 30303 Report Nos. :

50-280/79-6 and 50-281/79-6 Licensee:

Virginia Electric and Power Company P. 0. Box 26666 Richmond, Virginia 23261 Facility Name:

Surry 1 and 2 Docket No.:

50-280 and 50-281 License Nos.:

DPR-32 and DPR-37 Approved SUMMARY Inspection on January 15-19, 1979 Areas Inspected Section Chief, RONS Branch CJ EFB 7j Date Signed

/2 i(B 79 Date Signed

~f'f/19 hldsigned This special announced inspection involved 43 inspector-hours onsite in the areas of steam generator repair/replacement program and quality assurance program including organizational and functional alignmen Results Of the two (2) areas inspected, no apparent items of noncompliance or deviations were identifie O 3 2 8 o o=ieo

  • DETAILS Persons Contacted Virginia Electric and Power Company (VEPCO)
  • W. *A. *T. 'i,J. C. E. Y. *R. J. J. M. Stewart, Station Manager Parrish III, Project Manager Kenny, Outage Coordinator Goodson, Resident QC Engineer (Construction)

Rhodes, Resident Engineer, Construction Rivas, Resident Engineer, Construction Mangum, Jr., Resident Engineer, Project Control Saunders, Advisory Engineer Benton, Director Production Technical Support Wilson, Station Operations Superintendent Gettler, Civil Construction Supervisor Stone and Webster Engineering Corp. (S&W)

Leo Viens, Head, Site Engineering Office NRC Resident Inspector

  • D. J. Burke
  • Attended exit intervie.

Exit Interview The inspection scope and findings were summarized on January 19, 1979, with those persons indicated in paragraph 1 abov The licensee was informed that no items of noncompliance were disclosed by the inspectio The items listed in paragraph 6 were discusse The licensee committed to review the QA program as indicated in paragraph.

Unresolved Items Unresolved items were not identified during this inspectio Steam Generator Replacement/Repair Program The licensee program for repair/replacement of steam generators was reviewe This included review of numerous sub-parts of the single design change (DC-77-45) called Engineering Task Assignments (ETA), a

-2-tour of facilities involved, interviews with numerous management per-sonnel and a briefing by the Director of Production Technical Suppor VEPCO is managing the complete steam generator replacement project (SGRP).

VEPCO has obtained personnel for engineering and design support from Stone and Webster Engineering Corporation (S&W).

The S&W engineers are under direct supervision of VEPC Daniel Construction Company (DCC) will be the major site contractor. VEPCO will perform overall directional control of site contractor activitie.

Review of QA Program Inspector reviewed the QA program to ascertain whether QA plans, instruc-tions, and procedures have been established to control the safety related activities and that they conform to the QA program as described in the Safety Analysis Report, VEPCO's submittal for the Steam Generator Replace-ment Project and the NRC Safety Evaluation Repor The following specifications, contracts, QA Manuals, and documents were reviewed by the inspector: SGRP - Surry Power Station QA Manual - Supplement Safety Evaluation by the Office of Nuclear Reactor Regulation dated December 15, 1978 VEPCO/DCC Contract dated May 15, 1978 DCC QA Manual Specification and Purchase Oider (Williams Crane and Rigging, Inc.)

for rigging, handling and hauling of steam generator lower section.

Chicago Bridge and Iron Company Nuclear QA Manual for repairs and alterations to ASME code stamped component.

Williams Crane and Rigging procedure for handling of new steam generator lower shells at barge slip and in temporary storag VEPCO, in addition to overall program control, will review and approve all contractor QA programs; perform procurement functions including site receiving, inspection, storage and issue and provide assurance of VEPCO/

Contractor QA/QC program implementation through surveillance and audit function The inspector held discussions with responsible VEPCO/S&W/DCC Engineers, QA/QC and craft personnel, reviewed controlling specifications, QA Manuals, procedures, and observed that facilities are provided for the support of the requirements of the above document The above identified documents

..,.

-3-confirm that VEPCO and/or their agents have established QA/QC plans and procedures to assure that the SGRP work will be accomplished in accordance with QA program requirements. The following areas were examined: Organizational structure and QA personnel Audits Quality Requirements Design control Work and Quality Inspection Procedures Control of material Control of process Corrective action Document control 1 Test control and control of test equipment 1 Quality records During the inspection and at the exit interview, considerable discussion was held with VEPCO management and QA/QC personnel regarding the following areas: The VEPCO Nuclear Power Station QA Manual Supplement which requires further clarification to more clearly define non-specific require-ments that are identified in the manual supplements. These relate to written notification requirements of significant conditions, audit, control, record retention and maintenance, nonconformance report control, corrective action contro.

Final approval of DCC QC Manual prior to start of wor.

Present manning of the VEPCO Resident QC Group which appears to be inadequate if work were to begin immediately, it appears that some augmentation will be required before work begin.

Training and qualification of VEPCO Resident QC Section personnel to be accomplished prior to participating in active QC Section function VEPCO personnel acknowledged the areas of concern and coauni tted to review of the program areas and make necessary change This area will receive further inspection in the near future (280/79-6-01; 281/79-6-01).