June 25, 2008

SUBJECT:

PEACH BOTTOM ATOMIC POWER STATION - NRC TEAM INSPECTION REPORT 05000277/2008006 and 05000278/2008006

Dear Mr. Pardee:

On May 16, 2008, the U.S. Nuclear Regulatory Commission (NRC) completed a team inspection of your Peach Bottom Atomic Power Station. The enclosed report documents the teams results, which were discussed, on site, on May 2, 2008, and then by telephone, on May 16, 2008 with Mr. Michael Massaro and other members of your staff.

The inspection examined activities conducted under your license as they relate to the implementation of B.5.b Phase 2 and 3 mitigating strategies, your compliance with the Commissions rules and regulations, and with the condition of your operating license. Within these areas, the inspection involved examination of selected procedures and records, observation of activities, and interviews with station personnel.

This report documents three NRC-identified findings of very low safety significance (Green),

which were determined involve violations of NRC requirements. Because of the very low safety significance and because these violations were entered into your corrective action program, the NRC is treating these finding as non-cited violations (NCVs), in accordance with Section VI.A.1 of the NRCs Enforcement Policy. If you contest these NCVs, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001; with copies to the Regional Administrator, Region I; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Resident Inspector at the Peach Bottom Atomic Power Station.

When separated from the Enclosure, this document is DECONTROLLED. In accordance with 10 CFR 2.390 of the NRC Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of the NRC Agency-wide Documents Access and Management System (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the sensitive information contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be available for public inspection.

Sincerely,

/RA/

John F. Rogge, Chief

Engineering Branch 3

Division of Reactor Safety

Docket No. 50-277, 50-278 License No. DPR-44, DPR-56

Enclosure:

Inspection Report 05000277/2008006 AND 05000278/2008006

w/Attachment: Supplemental Information