IR 05000269/2017007

From kanterella
Jump to navigation Jump to search
Notification of Oconee Nuclear Station Design Bases Assurance Inspection - U.S. Nuclear Regulatory Commission Inspection Report 05000269/2017007, 05000270/2017007 and 05000287/2017007
ML16309A277
Person / Time
Site: Oconee  
(DPR-038, DPR-047, DPR-055)
Issue date: 11/03/2016
From: Bartley J
NRC/RGN-II/DRS/EB1
To: Teresa Ray
Duke Energy Corp
References
IR 2017007
Download: ML16309A277 (5)


Text

November 3, 2016

SUBJECT:

NOTIFICATION OF OCONEE NUCLEAR STATION DESIGN BASES ASSURANCE INSPECTION - U.S. NUCLEAR REGULATORY COMMISSION INSPECTION REPORT 05000269/2017007, 05000270/2017007 AND 05000287/2017007

Dear Mr. Ray:

The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC)

Region II staff will conduct a design bases assurance inspection (DBAI) at your Oconee Nuclear Station during the weeks of March 6 and March 20, 2017. Mr. Geoffrey Ottenberg, a Senior Reactor Inspector from the NRCs Region II office, will lead the inspection team. The inspection will be conducted in accordance with Inspection Procedure 71111.21M, Design Bases Assurance Inspection (Team), effective January 1, 2017. This inspection procedure is expected to be issued in November 2016, and will be provided after issuance.

The inspection will evaluate the capability of risk-significant/low-margin components to function as designed and to support proper system operation. The inspection will also include a review of selected operator actions, operating experience, and modifications.

During a telephone conversation on October 24, 2016, with Ms. Pam Metler, we confirmed arrangements for an information-gathering site visit and the two-week onsite inspection. The schedule is as follows:

  • Information-gathering visit: Week of January 30 - February 3, 2017

Onsite weeks: Weeks of March 6 - 10 and March 20 - 24, 2017

The purpose of the information-gathering visit is to meet with members of your staff to identify risk-significant components and operator actions. Information and documentation needed to support the inspection will also be identified. Mr. John Hanna, a Region II Senior Risk Analyst, will support Mr. Ottenberg during the information-gathering visit to review probabilistic risk assessment data and identify risk-significant components to be examined during the inspection.

Additionally, during the onsite weeks, time will be needed on the plant-referenced simulator in order to facilitate the development of operator action-based scenarios. The enclosure lists documents that will be needed prior to the information-gathering visit.

Please provide the referenced information to the Region II Office by January 23, 2017.

Additional documents will be requested following the information-gathering visit. The inspectors will try to minimize your administrative burden by specifically identifying only those documents required for inspection preparation. The additional information will be needed in the Region II office by February 24, 2017, to support the inspection teams preparation week. During the information-gathering trip, Mr. Ottenberg will also discuss the following inspection support administrative details: (1) availability of knowledgeable plant engineering and licensing personnel to serve as points of contact during the inspection; (2) method of tracking inspector requests during the inspection; (3) licensee computer access; (4) working space; (5)

arrangements for site access; and (6) other applicable information.

In accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding, of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Thank you for your cooperation in this matter. If you have any questions, regarding the information requested or the inspection, please contact Mr. Ottenberg at 404-997-4658 or contact me at 404-997-4607.

Sincerely,

/RA: Eric J. Stamm/

Jonathan H. Bartley, Chief

Engineering Branch 1

Division of Reactor Safety

Docket Nos.: 50-269, 50-270, 50-287 License Nos.: DPR-38, DPR-47, DPR-55

Enclosure:

Information Request for Oconee Nuclear Station, Design Bases Assurance Inspection

cc: Distribution via Listserv

_________________________

SUNSI REVIEW COMPLETE FORM 665 ATTACHED OFFICE RII:DRS RII:DRS

SIGNATURE GKO EJS2 FOR JHB1

NAME OTTENBERG BARTLEY

DATE 11/ /2016 11/ /2016

E-MAIL COPY?

YES NO YES NO YES NO YES NO YES NO YES NO YES NO

Enclosure INFORMATION REQUEST FOR OCONEE NUCLEAR STATION DESIGN BASES ASSURANCE INSPECTION

Please provide the information electronically in.pdf files, Excel, or other searchable format on CDROM (or FTP site, SharePoint, etc.). The CDROM (or website) should be indexed and hyperlinked to facilitate ease of use. The requested items below, identified with an asterisk (*),

should have a date range from January 1, 2014, until present.

1.

From your most recent probabilistic safety analysis (PSA) excluding external events and fires:

a. Two risk rankings of components from your site-specific PSA: one sorted by Risk Achievement Worth (RAW), and the other sorted by Birnbaum Importance

b. A list of the top 500 cut-sets

c. A list of the top 500 LERF contributors

2.

From your most recent PSA including external events and fires:

a. Two risk rankings of components from your site-specific PSA: one sorted by RAW, and the other sorted by Birnbaum Importance

b. A list of the top 500 cut-sets

3.

Risk ranking of operator actions from your site-specific PSA sorted by RAW and human reliability worksheets for these items

4.

List of time-critical operator actions with a brief description of each action

5.

  • List of components with low-design margins (i.e., pumps closest to the design limit for flow or pressure, diesel generator close to design-required output, heat exchangers close to rated design heat removal, and motor-operated valve risk-margin rankings, etc.) and associated evaluations or calculations

6.

  • List and brief description of safety-related structures, systems, or components (SSCs)

design modifications implemented

7.

  • List and brief description of Root Cause Evaluations performed 8.
  • List and brief description of common-cause component failures that have occurred

9.

List and brief description of equipment currently in degraded or nonconforming status as described in NRC Inspection Manual Chapter 0326, issued December 3, 2015 10. *List and brief description of Operability Determinations and Functionality Assessments

11. *List and reason for equipment that has been classified in maintenance rule (a)(1) status

12. *List of equipment on the sites Station Equipment Reliability Issues List, including a description of the reason(s) why each component is on that list, and summaries (if available) of your plans to address the issue(s) along with dates added or removed from the issues list

13. List of current operator work arounds/burdens

14. Copy of Updated Final Safety Analysis Report

15. Copy of Technical Specification(s)

16. Copy of Technical Specifications Bases

17. Copy of Technical Requirements Manual(s)

18. Copy of the Quality Assurance Program Manual

19. Copy of Corrective Action Program Procedure(s)

20. Copy of Operability Determination Procedure(s)

21. List of motor operated valves and air operated valves in the valve program, and their associated design margin and risk ranking

22. Primary AC and DC calculations for safety-related buses

23. One-line diagram of electrical plant (Electronic only)

24. Index and legend for electrical plant one-line diagrams

25. Piping and instrumentation diagrams (P&IDs) for safety-related systems (Electronic)

26. Index and Legend for P&IDs

27. Index (procedure number, title, and current revision) of station Emergency Operating Procedures, Abnormal Operating Procedures, and Annunciator Response Procedures

28. Copies of corrective action documents generated from previous CDBI

29. Copy of any self-assessments performed, and corrective action documents generated, in preparation for current CDBI

30. Contact information for a person to discuss PSA information prior to and during the information-gathering trip (Name, title, phone number, and e-mail address)