ULNRC-03971, Forwards Annual Personnel Exposure & Monitoring Rept for 1998, Per TS Sections 6.9.1.4 & 6.9.1.5.Rept Includes One Incident of Specific Activity Analysis of RCS in Which Limits of TS 3.4.8 Were Exceeded

From kanterella
Jump to navigation Jump to search
Forwards Annual Personnel Exposure & Monitoring Rept for 1998, Per TS Sections 6.9.1.4 & 6.9.1.5.Rept Includes One Incident of Specific Activity Analysis of RCS in Which Limits of TS 3.4.8 Were Exceeded
ML20207B687
Person / Time
Site: Callaway Ameren icon.png
Issue date: 02/26/1999
From: Passwater A
UNION ELECTRIC CO.
To:
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
Shared Package
ML20207B694 List:
References
ULNRC-03971, ULNRC-3971, NUDOCS 9903080213
Download: ML20207B687 (2)


Text

. .

, Unira fisceric One Ameren Plaza 1901 Chouteau Avenue PO Box 66149 5 St. Louis, M0 63166-6149 314.621.32t2 February 26,1999 i

REIRS Project Manager

, Office ofNuclear Regulatory Research

. U.S. Nuclear Regulatory Commission

. Washington, DC 20555-0001 1

Gentlemen
ULNRC-03971 ,

$4 f T j fg g[*g g DOCKET NUMBER 50-483

, CALLAWAY PLANT UNION ELECTRIC COMPANY ANNUAL PERSONNEL EXPOSURE AND MONITORING REPORT- 1998 i

Included herewith is the Personnel Exposure and monitoring Report for I

1998. submitted pursuant to Sections 6.9.1.4 and 6.9.1.5 of the Callaway j Plant Technical specifications.

This report is also required to include the results of specific activity 4

analysis of the reactor coolant system in which the limits of Specification

} 3.4.8 were exceeded. The attached report provides this information for one meldent in Callaway Cycle 9.

j If there are any questions relating to this information please contact us.

Very tmly yours,

/A U(

Ai Alan C. Passwater Manager, Corporate Nuclear Services i

DS/mlo Attachments /

'= .;y i,-

9903080213 PDR 990226 ' '

R ADOCK 05000483 pon_

r a ubnodoory of Amoren Corporanen

cc: M. d.-Fletcher Professional Nuclear Consulting, Inc. i 19041 Raines Drive Derwood, MD 20855-2432 Regional Administrator  :

U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive Suite 400 Pxlington, TX 76011-8064 I

Senior. Resident Inspector Callaway Resident Office U.S. Nuclear Regulatory Commission 8201 NRC Road i Steedman, MO 65077 Mrc Mel Gray (2) i Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 1 White Flint, North, Mail Stop 13E16 ,

11555 Rockville Pike '

Rockville, MD 20852-2738 l Manager, Electric Department Missouri Public Service Commission  ;

P.O. Box 360 Jefferson City, MO 65102 s

U.S. Nuclear Regulatory Commission Attn: Document Control Desk-Mail Station P1-137 Washington, DC 20555-0001 1

1 l

i , i