05000341/LER-2017-002, Regarding High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to Be Inoperable

From kanterella
(Redirected from 05000341/LER-2017-002)
Jump to navigation Jump to search
Regarding High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to Be Inoperable
ML17076A431
Person / Time
Site: Fermi 
Issue date: 03/16/2017
From: Polson K
DTE Electric Company
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NRC-17-0020 LER 17-002-00
Download: ML17076A431 (8)


LER-2017-002, Regarding High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to Be Inoperable
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(i)
LER closed by
IR 05000341/2017001 (1 May 2017)
3412017002R00 - NRC Website

text

Keith J. Poison Site Vice President DTE Energy Company 6400 N. Dixie Highway, Newport, MI 48166 Tel: 734.586.4849 Fax: 734.586.4172 Email: keith.polsontdteenergy.com 10 CFR 50.73 March 16, 2017 NRC-17-0020 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001

Reference:

Fermi 2 NRC Docket No. 50-341 NRC License No. NPF-43

Subject:

Licensee Event Report (LER) No. 2017-002 Pursuant to 10 CFR 50.73(a)(2)(i)(B) and 10 CFR 50.73 (a)(2)(v)(D), DTE Electric Company (DTE) is submitting LER No. 2017-002, High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to be Inoperable.

No new commitments are being made in this LER.

Should you have any questions or require additional information, please contact Mr. Scott A. Maglio, Manager -Nuclear Licensing, at (734) 586-5076.

Sincerely, Keith J. Polson Site Vice President

Enclosure:

Licensee Event Report No. 2017-002, High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to be Inoperable cc: NRC Project Manager NRC Resident Office Reactor Projects Chief, Branch 5, Region III Regional Administrator, Region III Michigan Public Service Commission Regulated Energy Division (kindschl@michigan.gov)

Enclosure to NRC-17-0020 Fermi 2 NRC Docket No. 50-341 Operating License No. NPF-43 Licensee Event Report (LER) No. 2017-002, High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to be Inoperable

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 1013112018 (06-2016)

Estimated burden per response to comply with this mandatory collection request:

80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br />.

Reported lessons learned are incorporated into the licensing process and fed back to industry.

LICENSEE EVENT REPORT LER Send comments regarding burden estimate to the FOIA, Privacy and Information Collections

(

)

Branch (T-5 F53), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by e-mail (See Page 2 for required number of digits/characters for each block) to Infocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0104), Office of Management and Budget, Washington, DC 20503. If a (See NUREG-1022, R.3 for instruction and guidance for completing this form means used to impose an information collection does not display a currently valid OMB control http://www.nrc.gov/readina-rm/doc-collections/nuregs/staff/srl022/r3/)

number, the NRC may not conduct or sponsor, and a person is not required to respond to, the information collection.

3. PAGE Fermi 2 05000 341 1 OF 6
4. TITLE High Water Level Indications at Low Reactor Pressures Causes Some Functions of High Pressure Coolant Injection System and Reactor Core Isolation Cooling System to be Inoperable
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED MONTH DAY YEAR YEAR SEQUENTIAL REV MONTH DAY YEAR NFACITYNAME DOCKETNUMBER MYER YR NUMBER NO.

/

05000 FACILITY NAME DOCKET NUMBER 01 19 2017 2017 -

002 00 03 16 2017 N/A 05000

9. OPERATING MODE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR : (Check all that apply) 20.2201(b)

[] 20.2203(a)(3)(i)

E 50.73(a)(2)(ii)(A)

Q 50.73(a)(2)(viii)(A) 1 El 20.2201(d) 20.2203(a)(3)(ii)

E] 50.73(a)(2)(ii)(B)

E] 50.73(a)(2)(viii)(B)

El 20.2203(a)(1) 20.2203(a)(4)

Q 50.73(a)(2)(iii)

Q 50.73(a)(2)(ix)(A) 20.2203(a)(2)(i)

E 50.36(c)(1)(i)(A)

[ 50.73(a)(2)(iv)(A) 50.73(a)(2)(x)

10. POWER LEVEL 20.2203(a)(2)(ii) 50.36(c)(1)(ii)(A)

Q 50.73(a)(2)(v)(A) 73.71(a)(4) 20.2203(a)(2)(iii)

E 50.36(c)(2)

[]50.73(a)(2)(v)(B) 73.71(a)(5) 20.2203(a)(2)(iv) 50.46(a)(3)(ii) 50.73(a)(2)(v)(C) 73.77(a)(1) 100 20.2203(a)(2)(v) 50.73(a)(2)(i)(A)

/

50.73(a)(2)(v)(D)

El 73.77(a)(2)(i) 20.2203(a)(2)(vi)

/ 50.73(a)(2)(i)(B) 50.73(a)(2)(vii) 73.77(a)(2)(ii) 50.73(a)(2)(i)(C)

OTHER Specify in Abstract below or in To prevent potential turbine damage due to flooding the reactor vessel above the main steam lines, the HPCI and RCIC systems are prevented from operating above the high reactor vessel water level (Level 8) setting in all actuation modes.

Once actuated, the HPCI high reactor vessel water level trip is sealed in and will inhibit automatic (or manual) system actuation until indicated water level drops below the Level 8 setting and the high reactor vessel water level trip is manually reset, or the trip signal is automatically reset when indicated reactor vessel water level reaches the Level 2 actuation setting. For RCIC, there is no seal-in circuit for the Level 8 trip, so once reactor vessel water level drops below the Level 8 setting, the RCIC system can be manually initiated, or the system is automatically initiated when indicated reactor vessel water level reaches the Level 2 actuation setting.

The Fermi 2 wide range reactor vessel level instruments are differential pressure type instruments that are reactor coolant density sensitive and are calibrated to be most accurate at normal reactor operating conditions. As a result, at low reactor coolant temperatures and pressures, because the reactor vessel water density is higher than at calibration conditions, these instruments read higher than actual water level. This level indication condition at low reactor pressures is acknowledged in plant procedures and training material. As a result of this level instrumentation condition, a high reactor vessel water level (Level 8) trip signal is present for the HPCI and RCIC systems at low reactor pressures (up to 600 psig),

but above the pressure at which the systems are required to be operable (150 psig) per Technical Specifications (TS) 3.5.1 and 3.5.3.

TS Table 3.3.5.1-1 requires HPCI "Drywell Pressure - High" and "Manual Initiation" actuation instrumentation to be operable when HPCI is required to be operable. Any challenge to the reactor coolant pressure boundary (RCPB) that results in a high drywell pressure condition will result in an automatic actuation of the HPCI system actuation logic; however, the system will not start (either automatically or manually) with the Level 8 trip present, as designed. The system would automatically start, without operator intervention, when a demand for inventory is sensed at reactor vessel water low-low level (Level 2). Similar to HPCI, TS Table 3.3.5.2-1 requires RCIC "Manual Initiation" actuation instrumentation to be operable when RCIC is required to be operable. However, as a result of the level instrumentation condition, a high reactor vessel water level trip signal is present for the RCIC system at low reactor pressures (up to 600 psig), but above the pressure at which the RCIC system is required to be operable (150 psig), and the system will not manually start with the Level 8 trip present, as designed. The system would automatically start, without operator intervention, when a demand for inventory is sensed at reactor vessel water low-low level (Level 2). This HPCI and RCIC operation is the same for a high reactor vessel water level occurring at rated pressure and temperature, or at low reactor vessel pressures and temperatures.

The TS Table 3.3.5.1-1 HPCI functions of "Drywell Pressure - High" (Function 3.b) and "Manual Initiation" (Function 3.f) and the TS Table 3.3.5.2-1 RCIC function of "Manual Initiation" (Function 4) should be considered inoperable when they are inhibited by a Level 8 trip signal at low reactor pressures (below 600 psig) based on the phenomena described above.

At the time of this discovery, Fermi 2 was operating at 100% power and the Reactor Vessel Water Level - High (Level 8) signal was not present. Therefore, the HPCI and RCIC functions in TS Tables 3.3.5.1-1 and 3.3.5.2-1 were all operable such that the condition did not exist at the time of discovery. No immediate actions were required. However, Fermi 2 had operated in a region of low reactor pressure in the past three years. A past operability review for the three years prior to January 19, 2017 was performed to identify when the Reactor Vessel Water Level - High (Level 8) signal was present while operating at low reactor pressures but above 150 psig. The instances are listed below:

1) At approximately 1330 EST on February 10, 2014, Fermi 2 entered MODE 3 for a refueling outage. During the ensuing shutdown, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.
2) At approximately 0130 EDT on March 28, 2014, Fermi 2 entered MODE 2 following a refueling outage. During the ensuing startup, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 19 hours2.199074e-4 days <br />0.00528 hours <br />3.141534e-5 weeks <br />7.2295e-6 months <br />.
3) At approximately 0230 EDT on April 16, 2014, Fermi 2 entered MODE 3 for an outage. During the ensuing shutdown, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
4) At approximately 1730 EDT on April 21, 2014, Fermi 2 entered MODE 2 following an outage. During the ensuing startup, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />.
5) At approximately 0700 EDT on March 19, 2015, Fermi 2 entered MODE 3 due to a reactor scram. During the ensuing shutdown, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />.
6) At approximately 0730 EDT on April 3, 2015, Fermi 2 entered MODE 2 following an outage. During the ensuing startup, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
7) At approximately 2300 EDT on September 13, 2015, Fermi 2 entered MODE 3 due to a reactor scram. During the ensuing shutdown, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.
8) At approximately 1300 EST on November 25, 2015, Fermi 2 entered MODE 2 following a refueling outage. During the ensuing startup, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 15 hours1.736111e-4 days <br />0.00417 hours <br />2.480159e-5 weeks <br />5.7075e-6 months <br />.
9) At approximately 2300 EDT on May 3, 2016, Fermi 2 entered MODE 3 for an outage. During the ensuing shutdown, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
10) At approximately 1630 EDT on May 12, 2016, Fermi 2 entered MODE 2 following an outage. During the ensuing startup, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />.
11) At approximately 0300 EST on November 7, 2016, Fermi 2 entered MODE 3 for an outage. During the ensuing shutdown, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
12) At approximately 2245 EST on November 11, 2016, Fermi 2 entered MODE 2 following an outage. During the ensuing startup, the Reactor Vessel Water Level - High (Level 8) signal was present for approximately 7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br />.

The twelve occurrences identified above are conditions where Fermi 2 was operating at low reactor pressure but above 150 psig such that the Reactor Vessel Water Level - High (Level 8) signal was present in a manner which would have prevented the injection of HPCI by the "Drywell Pressure - High" function and prevented the injection of HPCI and RCIC by the "Manual Initiation" functions. Considering these functions inoperable results in entry to TS Limiting Condition for Operation (LCO) 3.3.5.1 Condition A and TS LCO 3.3.5.2 Condition A. A review of the consequences of entering these LCOs is provided in the paragraphs that follow.

TS LCO 3.3.5.1 Required Action A.1 requires immediate entry to the Condition referenced by TS Table 3.3.5.1-1 for the inoperable channel(s). TS Table 3.3.5.1-1 references Conditions B and C for Functions 3.b and 3.f, respectively. For TS LCO 3.3.5.1 Condition B, Required Action B.2 requires declaring HPCI inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> from discovery of loss of HPCI initiation capability (this also results in entry to TS LCO 3.5.1 Condition E as discussed below). Required Action B.3 requires placing the channel(s) in trip within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Note that Required Action B.1 does not apply to Function 3.b. For TS LCO 3.3.5.1 Condition C, Required Action C.2 requires restoring the channel(s) to operable status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Note that Required Action C.1 does not apply to Function 3.f. If the Required Actions and associated Completion Times of TS LCO 3.3.5.1 Conditions B or C are not met, then Condition G applies and Required Action G.1 is to immediately declare associated supported feature(s) inoperable. Since Required Action A.1 has an immediate Completion Time and no entry to the LCO was made, Required Action A.1 was not met in any of the twelve occurrences. Required Action B.2 was also not met since all twelve occurrences exceeded 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Required Action B.3 would have been met since none of the twelve occurrences exceeded 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Since Required Action B.2 was not met, Condition G would have been entered and Required Action G.1 would not have been met since it has an immediate Completion Time. However, the action taken for Required Action G.1 would only have been to declare HPCI inoperable which was the same as already required by Required Action B.2.

TS LCO 3.3.5.2 Required Action A.1 requires immediate entry to the Condition referenced by TS Table 3.3.5.2-1 for the inoperable channel(s). TS Table 3.3.5.2-1 references Condition C for Function 4. For TS LCO 3.3.5.2 Condition C, Required Action C.1 requires restoring the channel(s) to operable status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Since Required Action A.1 has an immediate Completion Time and no entry to the LCO was made, Required Action A.1 was not met in any of the twelve occurrences. Required Action C.1 would have been met since none of the twelve occurrences exceeded 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

If HPCI is declared inoperable per TS LCO 3.3.5.1 Required Action B.2, entry to TS LCO 3.5.1 Condition E is required.

Required Action E.1 is to immediately verify by administrative means that RCIC is operable and Required Action E.2 is to restore HPCI to operable status within 14 days. Although the RCIC instrumentation "Manual Initiation" function would have been inoperable, none of the TS LCO 3.3.5.2 actions described above would have resulted in declaring the RCIC system inoperable during any of the twelve occurrences (i.e. RCIC was operable). The duration of each of the occurrences was also much less than 14 days. Therefore, although no entry to TS LCO 3.5.1 Condition E was made, both Required Actions E.1 and E.2 would have been met.

Finally, TS LCO 3.0.4 prohibits entry into a Mode or other specified condition in the Applicability unless certain criteria are met. As a result, the occurrences associated with the six startups discussed above (i.e. #2, #4, #6, #8, #10, and #12) would have been prohibited by TS LCO 3.0.4. This LCO does not prevent changes in Modes that are part of a shutdown and therefore does not apply to the six shutdowns described above (i.e. #1, #3, #5, #7, #9, and #11).

In consequence of the above discussion, a Licensee Event Report (LER) is being made in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 50.73. Since HPCI is a single train system, the inoperability of HPCI could have prevented the HPCI system from fulfilling its safety function to mitigate the consequences of an accident. Therefore, this LER is being made under 10 CFR 50.73(a)(2)(v)(D) as an "event or condition that could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident." In addition, TS LCO Required Actions were not performed within their associated Completion Times for twelve of the occurrences and TS LCO 3.0.4 was not met for six of the occurrences. Therefore, this LER is also being made under 10 CFR 50.73(a)(2)(i)

(B) as an "operation or condition which was prohibited by the plant's TS." No notification was made under 10 CFR 50.72 as the condition was not present at the time of discovery as previously described.

As discussed in the "Corrective Actions" subsection below, Fermi 2 submitted a license amendment request to revise the TS such that it will no longer be necessary to consider HPCI and RCIC functions inoperable due to the condition described in this LER.

SIGNIFICANT SAFETY CONSEQUENCES AND IMPLICATIONS

An engineering analysis was performed to evaluate the safety consequences and implications. The analysis determined that the HPCI functions of "Drywell Pressure - High" and "Manual Initiation" and the RCIC function of "Manual Initiation" are not required at reactor pressures below 600 psig in order for HPCI and RCIC to perform their intended safety functions. The analysis confirms that the HPCI and RCIC functions of "Reactor Vessel Water Level - Low-Low, Level 2" remain available and are sufficient to perform the intended safety functions. The details of the analysis were provided in the license amendment request submitted to the NRC on February 23, 2017 (see discussion in "Corrective Actions" subsection below). Since these functions of HPCI and RCIC are not required under low reactor pressure conditions, there are no safety consequences or implications associated with any of the twelve occurrences described above. In addition, the inoperability of the HPCI and RCIC functions described above was solely due to the presence of the Level 8 trip signal under low reactor pressure conditions, not due to any actual equipment problems or plant events. Fermi 2 procedures contain actions to defeat the Level 8 trip signal for HPCI and RCIC. Defeating the Level 8 trip would allow HPCI and RCIC to be manually initiated and HPCI to be automatically initiated on high drywell pressure. Therefore, these HPCI and RCIC functions were available during all of the periods described above even though they would have been considered inoperable. In conclusion, there was no adverse impact to public health and safety or to plant employees. There were no radiological releases.

CAUSE OF THE EVENT

The cause was that the specified conditions in the Applicability of certain functions in TS 3.3.5.1 and 3.3.5.2 were not consistent with the original design and licensing basis of the HPCI and RCIC systems. In addition, the TS Bases and/or Updated Final Safety Analysis Report (UFSAR) did not provide adequate description of the original design of the HPCI and RCIC systems with respect to the Level 8 trip signal. Per the original design, the reactor level instrumentation is calibrated for normal operating pressure conditions and therefore reads higher than the Level 8 trip signal under low pressure conditions.

CORRECTIVE ACTIONS

As discussed previously, no immediate action was required to restore compliance since the condition did not exist at the time of discovery. This LER is being submitted to report the previous occurrences of this condition. To prevent future occurrence of this condition, Fermi 2 submitted a license amendment request to the NRC on February 23, 2017, to modify TS 3.3.5.1 and 3.3.5.2 to clarify the applicability of certain HPCI and RCIC functions. In addition, Fermi 2 plans to modify the TS Bases and/or UFSAR to include additional details regarding the Level 8 trip signal.

PREVIOUS OCCURRENCES

The previous occurrences within the past three years were discussed in this LER.Page 6

of 6