05000266/LER-1997-041, Forwards LER 97-041-00 Which Describes Discovery of Potential Common Mode Failure in Control Circuits of AFW Sys at Pbnp,Unit 1.Commitments Made within Ltr,Encl

From kanterella
(Redirected from 05000266/LER-1997-041)
Jump to navigation Jump to search
Forwards LER 97-041-00 Which Describes Discovery of Potential Common Mode Failure in Control Circuits of AFW Sys at Pbnp,Unit 1.Commitments Made within Ltr,Encl
ML20199L728
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 11/24/1997
From: Dante Johnson
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20199L733 List:
References
NPL-97-0754, NPL-97-754, NUDOCS 9712020093
Download: ML20199L728 (1)


LER-2097-041, Forwards LER 97-041-00 Which Describes Discovery of Potential Common Mode Failure in Control Circuits of AFW Sys at Pbnp,Unit 1.Commitments Made within Ltr,Encl
Event date:
Report date:
2662097041R00 - NRC Website

text

, __ _ _________-_ ____- __-___ - __ - _ _.

iii L; -

Wisconsin

. Electnc POWER COMPANY Point Beoch Nuclear Plant (414) 755-2?21 6610 Nuclear Ro.. Two Rrvors. WI 54241 NPL 97-0754 November 24,1997 Document Control Desk U.S. NUCLEAR REGULATORY COMMISSION Mail Station PI-137 Washington, D. C. 20555 Ladies / Gentlemen-DOCKET 50-266 LICENSEE EVENT REPORT 97-041-00 POTENTI Al. COMMON MODE FAILURE IN AUXII,l ARY FEEDWATER SYSTEM CONTROL, CIRCUITS POINT HEACII NUCI. EAR Pl. ANT. UNIT 1 Enclosed is 1.icensee Event Report 97-041-00 for Point Beach Nuclear Plant. Unit 1. This report is provided in accordance with 10 CFR 50.73(a)(2)(ii)(B),"a condition that was outside the design basis of the plant." This report describes the discovery of a potential common mode failure in the control circuits of the Auxiliary Feedwater (AFW) System which could disable two of the three AFW pumps associated with Unit I operability. This condition wculd challenge the capability of the remaining motor-driven AFW pump to satisfy the feedwater requirements for the design basis events requiring AFW System operation.

New commitments within the report are indicated in italics.

Please contact us if you require additional information.

Sincerely,

+

8 -

T h 2 } jg D. F. Johnson Manager '

Regulatory Services & Licensing Enclosure ec: NRC Resident inspector i NRC Regional Administrator PSCY/

bllllll0lll]l{lll INPO Support Services 9712O20093 971124 PDR ADOCK 05000266 8 PDR .-

^ Asuuateofxhwash %efoqmth>n

, y,[QUL4

- _ _ _ _ _ _