05000301/LER-1997-001, Forwards LER 97-001-00,re Containment Structure Where Internal Containment Structural Members Could Have Damaged Containment Liner During Safe Shutdown Earthquake

From kanterella
Jump to navigation Jump to search
Forwards LER 97-001-00,re Containment Structure Where Internal Containment Structural Members Could Have Damaged Containment Liner During Safe Shutdown Earthquake
ML20134H773
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 02/06/1997
From: Dante Johnson
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20134H776 List:
References
PBL-97-0042, PBL-97-42, NUDOCS 9702110460
Download: ML20134H773 (1)


LER-2097-001, Forwards LER 97-001-00,re Containment Structure Where Internal Containment Structural Members Could Have Damaged Containment Liner During Safe Shutdown Earthquake
Event date:
Report date:
3012097001R00 - NRC Website

text

- _ . - _- . ._ _

l Wisconsin Electnc POWER COMPANY F

Point Beoch Nuclear Plant (414) 755-2321 6610 Nuclear Rd., Two Rivers. WI 54241 <

i PBL 97-0042 February 6,1997 '

Document Control Desk U.S. NUCLEAR REGULATORY COMMISSION Mail Station PI-137 Washington, D. C. 20555 Ladies / Gentlemen:

DOCKET 50-301 LICENSEE EVENT REPORT 97-001-00 CONTAINMENT LINER CLEARANCE NOT IN l ACCORDANCE WITH PLANT DESIGN BASIS POINT BEACH NUCl. EAR PLANT. UNIT 2 i

Enclosed is Licensee Event Report 97-001-00 for Point Beach Nuclear Plant, Unit 2. This report is provided in accordance with 10 CFR 50.73(aX2XiiXB),"Any event or condition that resulted in the nuclear power plant being in a condition that i was outside the design basis of the plant." This report describes the identification of one location inside the Unit 2 l containment structure where internal containment structural members could have damaged the containment liner during a safe shutdown earthquake (SSE), contrary to the plant design basis which requires containment integrity to be maintained during a SSE.

Please contact us if you require additional information.

Sincerely, Douglas F. Johnson Manager - Regulatory Services & Licensing

{

cib ,

Enclosure .

3.- >

cc: NRC Resident Inspector NRC Regional Administrator 9702110460 970206 PDR ADOCK 05000301 S PDR bhN A subsMhn af Hinwsh Ency Gepuativi