NRC-94-4318, Forwards non-proprietary WCAP-14191, Scaling Analysis for AP600 Passive Containment Cooling Sys, & Proprietary WCAP-14190, Scaling Analysis for AP600 Passive Containment Cooling Sys.Proprietary Portion of Doc Sent to Westinghouse

From kanterella
Revision as of 15:06, 11 December 2021 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards non-proprietary WCAP-14191, Scaling Analysis for AP600 Passive Containment Cooling Sys, & Proprietary WCAP-14190, Scaling Analysis for AP600 Passive Containment Cooling Sys.Proprietary Portion of Doc Sent to Westinghouse
ML20149G816
Person / Time
Site: 05200003
Issue date: 10/27/1994
From: Liparulo N
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Borchardt R
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20149G819 List:
References
NTD-NRC-94-4318, NUDOCS 9411080034
Download: ML20149G816 (160)


Text

, ,

Westinghouse Energy Systems Ba 355 Pmsbu@ PennsyNania 15230 0355 Electric Corporation NTD-NRC-94-4318 DCP/NRC0227 Docket No.: STN-52-003 October 27,1994 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 t

ATTENTION: MR. R. W. BORCHARDT

SUBJECT:

AP600 PASSIVE CONTAINMENT COOUNG SYSTEM SCALING REPORT

Dear Mr. Borchardt:

Enclosed is a report addressing scaling for the AP600 Passive Containment Cooling System (PCCS).

The following enclosures are provided:

Enclosure 1 WCAP-14190, " Scaling Analysis for AP600 Passive Containment Cooling System,"

t October,1994 (proprietary),

/

Enclosure 2 - WCAP-1419/, " Scaling Analysis for AP600 Passive Containment Cooling System,"

October,1994 (non-proprietary).

f The Westinghouse Electric Corporation copyright notice, proprietary information notice, application for t withholding and affidavit are attached.

This submittal contains Westinghouse proprietary information consisting of trade secrets, commercial information or financial information which we consider privileged or confidential pursuant to 10CFR2.790. Therefore, it is requested that the Westinghouse proprietary information attached hereto be handled on a confidential basis and be withheld from public disclosures.

This material is for your internal use only and may be used for the purpose for which it is submitted.

It should not be otherwise used, disclosed, duplicated, or disseminated, in whole or in part, to any other person or organization outside the Commission, the Office of Nuclear Reactor Regulation, the Office of Nuclear Regulatory Research and the necessary subcontractors that have signal a proprietary non-disclosure agreement with Westinghouse without the express written approval of Westinghouse.

Correspondence with respect to the application for withholding should refererce AW-94-737, and should be addressed to N. J. Liparuto, Manager of Nuclear Safety Regulatory And Licensing Activities, Westinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania, 15230-0355.

.f .

I am 9411080034 941027 PDR pk ADOCK 05200003 1\g i

A PDR s \d

a l

l NTD-NRC-94-4318 DCP/NRCO227 October 27,1994 1

1 1

Please contact Brian A. McIntyre on (412) 374-4334 if you have any questiona concerning this transmittal.

4 /NYN vl N. J. Liparulo, Man r Nuclear Safety Regulatory And Licensing Activiti u

/nja Attachments Enclosures cc: T. Kenyon, NRC (w/o Enclosures / Attachments)

R. Hasselberg, NRC (5 copies of Enclosure 1,3 copies of Enclosure 2)

C Hoxie, NRC (Enclosure 1)

A. Notafrancesco, NRC P. Bochnert, ACRS (5 copics of Enclosure 1)

L Shotkin, NRC (w/o Enclosures /Attachmen's)

B. A. McIntyre, Westinghouse (w/o Enclosures / Attachments) 2143A w._ m