MONTHYEARML24127A2402024-05-0707 May 2024 Presentation Slides for Prairie Island 2023 End-of-Cycle Meeting ML24029A0382024-01-31031 January 2024 January 31, 2024, Pre-application Meeting Presentation - Prairie Island ISFSI License Amendment Request to Add Grace to License Conditions ML23168A0032023-06-20020 June 2023 Handout for 6/23/2023 Pre-Application Public Meeting with Prairie Island Nuclear Generating Plant to Revise ISFSI TS 4.4 for TN-40HT Casks ML23156A2602023-06-0505 June 2023 2022 Prairie Island End-of-Cycle Meeting Presentation ML23102A1752023-04-14014 April 2023 April 14, 2023 TS 3.7.8 LAR Pre-Submittal Meeting Slides ML22130A5852022-05-10010 May 2022 2021 Monticello and Prairie Island Nuclear Generating Plant End-of-Cycle Meeting Presentation ML22048B1812022-02-18018 February 2022 Pre-Application Meeting for Prairie Island TS 5.6.6, PTLR, LAR ML21221A0202021-08-11011 August 2021 Nis Pr Bypass Test Panel License Amendment Request ML21166A3792021-06-15015 June 2021 Units 1 and 2 2020 End-of-Cycle Meeting Presentation ML21032A2632021-02-0303 February 2021 Slides for Public Meeting with Xcel Energy to Discuss a Planned Amendment to Combine the Emergency Plans and Create a Common Emergency Offsite Facility for Monticello and Prairie Island ML19347B0722019-12-12012 December 2019 TVA and Xcel Energy Slides for Joint Presubmittal Meeting to License Amendment Requests to Adopt WCAP-17661, Revision 1 ML19268A0422019-09-26026 September 2019 Pre-Application Meeting License Amendment Request Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b ML19210D4512019-07-22022 July 2019 Abeyance Seal Preapplication Meeting Slides ML18051A1752018-02-20020 February 2018 Pre-Application Meeting License Amendment for TSTF-425 Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program Xcel Energy 2/20/2018 ML17240A3382017-08-30030 August 2017 Non-Safety Related Digital Feedwater and Amsac/Dss Control Systems Replacement Project Presentation ML17198A2632017-07-17017 July 2017 Pre-Application Meeting ML17066A3732017-03-0909 March 2017 Spent Fuel Pool Criticality Technical Specification Changes Round 2 Request for Additional Information Public Meeting: March 9, 2017 ML17037D1172017-02-0707 February 2017 License Amendment Requests for Change in Emergency Plan Staff Augmentation Response Times Pre-Submittal Meeting for Prairie Island Nuclear Generating Plant Monticello Nuclear Generating Plant: February 7, 2017 ML17023A0652017-01-24024 January 2017 Pre-Submittal Call Regarding License Amendment Requests for Prairie Island Nuclear Generating Plant, Units 1 and 2 and Monticello Nuclear Generating Plant Emergency Action Level Scheme Changes ML15140A3342015-05-13013 May 2015 Public Meeting 05132015 Licensee Slides Only ML15105A0372015-04-14014 April 2015 Xcel Energy Slide Presentation to Support Pre-Application Meeting on April 14, 2015, to Discuss Nuclear Fuel Design Transition to Include Integral Fuel Burnable Absorber (Ifba) at the Prairie Island Nuclear Generating Plant ML14323B0222014-11-19019 November 2014 Regcon, November 19-20, 2014: 03-Info-Session-2 Ronald Johnson - Tribal Perspective on Continued Storage ML14153A0242014-05-16016 May 2014 Xcel Energy'S Presentation Slides Supporting a May 16, 2014, Public Meeting to Discuss the Flood Hazard Reevaluation Schedule for the Monticello and Prairie Island Nuclear Generating Plants ML14058A1732014-02-19019 February 2014 Diesel Generator Steady State Voltage and Frequency Limits - Prairie Island Nuclear Generating Plant Meeting February 19, 2014 ML13210A2012013-07-29029 July 2013 2012 End-of-Cycle Slides - Licensee ML13210A2002013-07-11011 July 2013 2012 End-of-Cycle Slides ML13056A0262013-02-25025 February 2013 Regulatory Conference Slide Presentation ML12340A5402012-12-0606 December 2012 Reactor Core Cooling & Heat Removal FLEX Strategy - Phase 1 ML12326A9712012-11-21021 November 2012 Encl 3 (Handouts - Public) to Summary of October 24, 2012, Meeting with the Northern States Power Company, D/B/A Excel Energy Regarding Security Requirements and Changes Pertaining to Prairie Island TAC L24689 ML12277A1762012-10-0404 October 2012 Steam Generator Replacement Presentation ML12275A4652012-09-27027 September 2012 Meeting September 27, 2012 - Handouts ML12275A3782012-09-27027 September 2012 Xcel Energy Prairie Island Nuclear Generating Plant Meeting Presentation, Diesel Generator Voltage and Frequency Limits. ML12205A2172012-07-23023 July 2012 NRC 2011 End-of-Cycle Slides ML12205A2202012-07-17017 July 2012 Licensee 2012 End-of-Cycle Slides ML12115A3112012-04-24024 April 2012 Meeting Slides: 04/24/2012 Meeting with Xcel Energy NFPA 805 Presubmittal - Prairie Island Nuclear Generating Plant ML1207904792012-03-14014 March 2012 March 14, 2012 Telecon Slides ML1122803892011-08-18018 August 2011 Pre-Application Meeting for Prairie Island Nuclear Generating Plant (Ping) Extended Power Uprate (EPU) ML1119903462011-07-28028 July 2011 Meeting Presentation, Prairie Island Nuclear Generating Plant - Failure to Maintain the Train a and B Direct Current Electrical Power Subsystems Operable ML1117804242011-06-22022 June 2011 June 22, 2011, Meeting Handout #1 - NRC Meeting Diesel Fuel Oil LAR for Prairie Island Ngp ML1120701572011-06-22022 June 2011 June 22, 2011, Meeting Handout #2 - Proposed Technical Specification Changes for Prairie Island Ngp Diesel Fuel Oil LAR ML1106600792011-03-0303 March 2011 March 3, 2011 Meeting Handouts - Revise Footnote in TS 3.8.1, Prairie Island Nuclear Generating Plant ML1034701142010-12-14014 December 2010 Excel Energy Slides for Public Meeting 12/14/2010 to Discuss Human Performance Issues ML1027802642010-10-0404 October 2010 Session 4 - Heather Westra Presentation at October 4, 2010, Public Meeting on Groundwater Protection ML1023805712010-08-25025 August 2010 Meeting Presentation Alternative Source Term Steam Generator Tube Rupture Margin to Overfill Evaluation - Prairie Island Nuclear Generating Plant ML1014502432010-05-26026 May 2010 Responses to Questions from the Prairie Island Indian Community Concerning Issues Related to Prairie Island Nuclear Generating Plant ML1012604192010-05-20020 May 2010 Meeting Presentation Prairie Island Annual Assessment Meeting - Reactor Oversight Program - 2009 ML1012503422010-05-0505 May 2010 Regulatory Conference Slides ML1015801072010-04-28028 April 2010 2R26 Outage, SG Tube Inspection Telecon Slides ML1010604782010-04-15015 April 2010 April 15, 2010, Meeting Slides - Pre-Application Meeting for Prairie Island Ngp Extended Power Uprate ML0932901282009-12-0101 December 2009 Licensee Slides for Public Meeting 2024-05-07
[Table view] Category:Slides and Viewgraphs
MONTHYEARML24127A2402024-05-0707 May 2024 Presentation Slides for Prairie Island 2023 End-of-Cycle Meeting ML24059A4042024-03-0606 March 2024 March 6, 2023, Presubmittal Meeting for License Amendment Request to Modify Technical Specifications Definitions & Approve Plant-Specific Methods for Response Time Testing (EPID L-2024-LRM-0034) - Slides ML24029A0382024-01-31031 January 2024 January 31, 2024, Pre-application Meeting Presentation - Prairie Island ISFSI License Amendment Request to Add Grace to License Conditions ML23168A0032023-06-20020 June 2023 Handout for 6/23/2023 Pre-Application Public Meeting with Prairie Island Nuclear Generating Plant to Revise ISFSI TS 4.4 for TN-40HT Casks ML23156A2602023-06-0505 June 2023 2022 Prairie Island End-of-Cycle Meeting Presentation ML23102A1752023-04-14014 April 2023 April 14, 2023 TS 3.7.8 LAR Pre-Submittal Meeting Slides ML22130A5852022-05-10010 May 2022 2021 Monticello and Prairie Island Nuclear Generating Plant End-of-Cycle Meeting Presentation ML22048B1812022-02-18018 February 2022 Pre-Application Meeting for Prairie Island TS 5.6.6, PTLR, LAR ML21166A3792021-06-15015 June 2021 Units 1 and 2 2020 End-of-Cycle Meeting Presentation ML21124A0652021-05-0606 May 2021 Xcel Energy Presentation for May 6, 2021 Public Meeting to Discuss 24-Month Cycles at Prairie Island Nuclear Generating Plant, Units 1 and 2 ML21032A2632021-02-0303 February 2021 Slides for Public Meeting with Xcel Energy to Discuss a Planned Amendment to Combine the Emergency Plans and Create a Common Emergency Offsite Facility for Monticello and Prairie Island ML20266F1052020-09-23023 September 2020 (PINGP) COVID-19 Exemption Request for the 2020 Biennial Emergency Preparedness Exercise ML20212L8622020-07-29029 July 2020 2019 Monticello and Prairie Island EOC Presentation from Webinar ML20098F0682020-04-0909 April 2020 Preapplication Teleconference Presentation: License Amendment Request to Adopt TSTF-569 ML20057D3082020-02-18018 February 2020 Slides Potential License Amendment to Remove Note from LCO 3.4.12 and LCO 3.4.13 ML19268A0422019-09-26026 September 2019 Pre-Application Meeting License Amendment Request Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b ML19210D4512019-07-22022 July 2019 Abeyance Seal Preapplication Meeting Slides ML19071A2782019-03-0707 March 2019 Enclosure 3: Meeting Slides (Summary of February 28, 2019, Public Meeting with Xcel Energy to Discuss Increasing the Amount of Special Nuclear Material Authorized for Storage at the Prairie Island ISFSI (W/Enclosures 1 and 2)) ML18162A0262018-06-12012 June 2018 License Amendment Request to Reclassify Certain Fuel Handling Equipment ML18051A1752018-02-20020 February 2018 Pre-Application Meeting License Amendment for TSTF-425 Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program Xcel Energy 2/20/2018 ML17240A3382017-08-30030 August 2017 Non-Safety Related Digital Feedwater and Amsac/Dss Control Systems Replacement Project Presentation ML17209A1192017-07-17017 July 2017 Summary of July 17, 2017, Meeting with Northern States Power Company, Doing Business as Xcel Energy, on Potential License Amendment Request Related to Heavy Lifting Devices ML17198A2632017-07-17017 July 2017 Pre-Application Meeting ML17066A3732017-03-0909 March 2017 Spent Fuel Pool Criticality Technical Specification Changes Round 2 Request for Additional Information Public Meeting: March 9, 2017 ML17037D1172017-02-0707 February 2017 License Amendment Requests for Change in Emergency Plan Staff Augmentation Response Times Pre-Submittal Meeting for Prairie Island Nuclear Generating Plant Monticello Nuclear Generating Plant: February 7, 2017 ML17023A0652017-01-24024 January 2017 Pre-Submittal Call Regarding License Amendment Requests for Prairie Island Nuclear Generating Plant, Units 1 and 2 and Monticello Nuclear Generating Plant Emergency Action Level Scheme Changes ML16280A0372016-09-29029 September 2016 Flood Hazard Reevaluation Report - Response to Requested Information (CAC Nos. MF7710 and MF7711) - Figure 2 of 3 ML16280A0422016-09-29029 September 2016 Flood Hazard Reevaluation Report - Response to Requested Information (CAC Nos. MF7710 and MF7711) - Figure 3 of 3 ML16280A0352016-09-29029 September 2016 Flood Hazard Reevaluation Report - Response to Requested Information (CAC Nos. MF7710 and MF7711) - Figure 1 of 3 ML15140A3342015-05-13013 May 2015 Public Meeting 05132015 Licensee Slides Only ML15127A6562015-05-0707 May 2015 PI EOC Mtg NRC Slides ML15105A0372015-04-14014 April 2015 Xcel Energy Slide Presentation to Support Pre-Application Meeting on April 14, 2015, to Discuss Nuclear Fuel Design Transition to Include Integral Fuel Burnable Absorber (Ifba) at the Prairie Island Nuclear Generating Plant ML14323B0222014-11-19019 November 2014 Regcon, November 19-20, 2014: 03-Info-Session-2 Ronald Johnson - Tribal Perspective on Continued Storage ML14162A5202014-06-11011 June 2014 Slides: Prairie Island Independent Spent Fuel Storage Installation - License Renewal Application - Discussion of Requests for Additional Information, for June 16, 2014, Public Meeting ML14153A0242014-05-16016 May 2014 Xcel Energy'S Presentation Slides Supporting a May 16, 2014, Public Meeting to Discuss the Flood Hazard Reevaluation Schedule for the Monticello and Prairie Island Nuclear Generating Plants ML14084A3242014-03-21021 March 2014 M140321: Slides - Presented by Multiple Participants at Commission Briefing on Waste Confidence Rulemaking ML13210A2012013-07-29029 July 2013 2012 End-of-Cycle Slides - Licensee ML13210A2002013-07-11011 July 2013 2012 End-of-Cycle Slides ML13056A0262013-02-25025 February 2013 Regulatory Conference Slide Presentation ML12340A5402012-12-0606 December 2012 Reactor Core Cooling & Heat Removal FLEX Strategy - Phase 1 ML12326A9712012-11-21021 November 2012 Encl 3 (Handouts - Public) to Summary of October 24, 2012, Meeting with the Northern States Power Company, D/B/A Excel Energy Regarding Security Requirements and Changes Pertaining to Prairie Island TAC L24689 ML12277A1762012-10-0404 October 2012 Steam Generator Replacement Presentation ML12275A3782012-09-27027 September 2012 Xcel Energy Prairie Island Nuclear Generating Plant Meeting Presentation, Diesel Generator Voltage and Frequency Limits. ML12205A2172012-07-23023 July 2012 NRC 2011 End-of-Cycle Slides ML12205A2202012-07-17017 July 2012 Licensee 2012 End-of-Cycle Slides ML12115A3112012-04-24024 April 2012 Meeting Slides: 04/24/2012 Meeting with Xcel Energy NFPA 805 Presubmittal - Prairie Island Nuclear Generating Plant ML1207904792012-03-14014 March 2012 March 14, 2012 Telecon Slides ML1122803892011-08-18018 August 2011 Pre-Application Meeting for Prairie Island Nuclear Generating Plant (Ping) Extended Power Uprate (EPU) ML1119903462011-07-28028 July 2011 Meeting Presentation, Prairie Island Nuclear Generating Plant - Failure to Maintain the Train a and B Direct Current Electrical Power Subsystems Operable ML1117804242011-06-22022 June 2011 June 22, 2011, Meeting Handout #1 - NRC Meeting Diesel Fuel Oil LAR for Prairie Island Ngp 2024-05-07
[Table view] |
Text
£/1 02..-0{;>~
Prairie Island Nuclear Generating Plant Pre-Decisional Enforcement Conference August 2, 2002 NMC)
!f-.--- _Ag e nda_.~_._._____ . _.. ~__.
__.. .~.~ct~aLSllJ)1mar____ '1_
- Calvert Cliffs event review
- 06 operating and maintenance history prior to April 2001
- April 9 06 surveillance problems and NOEO request
- Events subsequent to April 16 grant of NOED
1996
- May - July 1996 - OE Report screened at PINGP
- PINGP lube oils have Total Base Number(TBN) and sulfated ash properties similar to Calvert Cliffs
- No immediate action: fuel sulfur content high (0.18%), no scuffing noted during Preventive Maintenance (PM)
- Corrective actions: Discuss need to change oil with vendors, obtain recommendations for oil change by 1/1/97 to include in PM if required
- Nov 1996 - PINGP engineer attends SACM conference
- Summarized Calvert Cliffs experience as an "incompatibility between an entirely synthetic oil with a high TBN (> 15), high CD classification, and a low sulfur fuel"
- No problems with extensive use of mineral or synthetic lube oil and low sulfur fuel in Sweden, Germany, Switzerland & France
- SACM conclusion was "not enough experience" to "express formal statements about the lubricant-fuel influences"
.~~--~---~
NMC) 3
1996 - 1999
- Late 1996 - Mobil and SACM contacts
- Nov 1998 - 06 5-yr inspection and rebuild (530 hours0.00613 days <br />0.147 hours <br />8.763227e-4 weeks <br />2.01665e-4 months <br />)
- Some carbon buildup, rings move freely, no indications of blow-by
- BG&E experienced engineer involved
- Feb 1999 - PINGP attends SACM Owners Group meeting
- Calvert Cliffs solution included switch to mineral oil
- PINGP engineers report on high temperature in one 06 cylinder
- No linkage of 06 cylinder problem to oil incompatibility
- Nov 1999 - 06 24-hr load test completed successfully NM~
4
2000 - 2001
- Jan 2000 - Revised OE due date to Nov 2000
- Sulfur content dropping slowly, PINGP perceived that the industry and vendors did not agree with Calvert Cliffs root cause analysis
- May 2000 - 05 5-yr inspection and rebuild (450 hrs)
- No abnormal indications
- PINGP inspections of D5 and D6 found no ring problems, no scuffing, no blow-by, and "exceptional results" after 450 and 530 operating hours
- Calvert Cliffs reported hard deposits under rings, liner scuffing at 140-170 operating hours
Conclusions:
(1) Lube oil change not recommended; (2) Current performance monitoring and PMs adequate to identify condition
- Monthly surveillance runs and inspections satisfactory
- No data suggesting oil incompatibility NMC) 5
~ umma~Y-l~96__.-_2_~O O1_____ ~_~_______
- Complex technical issue, conflicting operating data
- Disagreement over Calvert Cliffs conclusion
- No evidence at PINGP after four years
- Continuing to look for indications
-\
NM~
6
~_ Februar-y - April?~Q01
- "Fuel oil" leak reported
- Elevated crankcase pressure noted in log
- Apr 9, 2001 - Monthly run
- 0930 - entered TS LCO for 06 monthly run
- 1330 - terminated engine run -- elevated crankcase pressure
- 1500 - SACM recommends full borescope inspection
- 1526 - 05 Operability run
- 1600 - Borescope identified bore polishing and blow-by on 06 E2-B1
- 1719 - Initiated a work order to repair D6
.:It:
NM~
7
,..----______1:)6 E2-B1 H i~_~~ I~j_~_~ 'lY-- a _ p r()~b ~e m
- Sep 1997 D6 E2-B1 high exhaust temperature
- Feb 1998 Calibrated 06 E2-B1 exhaust temperature instrument - no change
- Feb 1999 Swapped 06 E2-B1/B5 fuel injection pumps
- Apr 1999 Returned 06 E2-B1/B5 fuel injection pumps
- Apr 2001 Blow-by in same cylinder NMC>
8
Draft NOED Pr~p_~_raJion_ . ____
- Management considers contingency need for NOED to complete engine re-assembly
- Condition Report initiated to assess cylinder problem
- Licensing prepares initial draft NOED following guidance in NRC Inspection Manual and previous PINGP NOED request
- 0730 - SACM Tech Rep arrives to support re-assembly
- 1300 - OC reviews draft NOED, oil incompatibility not raised as issue
- 1400 - Draft NOED request faxed to NRC
- 1430 - Conference call with NRC Staff to discuss NOED NMC:>
9
"/
First Conference Call With NRC
- Focus on PRA and compensatory measures
- Mr. Carlson substitutes for system engineering
- Site responded to NRC Staff questions
- History of D6 problem requiring NOED
- Apparent cause - high crankcase pressure from blow-by in a single cylinder
- Cause of blow-by not known
- No indication affecting other cylinders/other engines
- Collective engineering judgment: problem limited to E2-B1 Single problematic cylinder exhibiting limited blow-by
- No basis for tie to D5 or Calvert Cliffs
- Additional PRA information requested
- Follow-up callan April 16, 2001, to confirm need for NOED, PRA changes, NMC) 10
~_ Weekenq_t:!_~~~J~WQrk_______~____
- 1308 - 06 reassembled
- 1835 - Start 06 break-in run
- 0448 - Started 06 24-hr load test
- 0449 - Completed 06 24-hr load test
- 0630 - OC meeting to approve NOED request
- 0730 - NRC conference call -- NOED verbal approval NM~
11
Second Conference Call
- NOED needed - engine not re-assembled
- Revised PRA discussion per April 13 call
- NRC Staff verbally granted NOED
- 06 Successfully Completed 34 hours3.935185e-4 days <br />0.00944 hours <br />5.621693e-5 weeks <br />1.2937e-5 months <br /> of Operation
- Break-in period
- Load test
- No unusual operating parameters, no blow-by
- All indications were that problem limited to single cylinder NMC) 12
Context of the NOED
- PINGP did not suspect credible common mode failure mechanism before or during the NOED
- Site experience supported preliminary conclusion of an isolated cylinder problem of unknown cause
- Focus was on problematic E2-81
- Available information did not point to oil incompatibility
- Single cylinder
- D5 apparently unaffected
- Did not find any "sticky rings"
- Questionable validity of Calvert Cliffs conclusion
- Different type of oil (mineral v. synthetic)
NMC) 13
Re~urn to O~erability "--"----------
Apr 16, 2001
- 0930 - NOED effective
- 1100 - Conference call with SACM (France)
- Purpose to discuss engine condition
- Agreement on 12-hr run and borescope to confirm "break in" marks
- Many potential root causes discussed
- No root cause matched all PINGP conditions
- Oil incompatibility discussed -- SACM could not explain limitation of symptoms to a single cylinder
- 1300 - PINGP personnel and tech rep discuss status, pursue investigation
- 0047 - Started D6 12-hr load test
- C/C pressure normal
- E2-B1 temperature w/in 50 degrees of others
- 1410 - Completed 06 12-hr load test
- 1500 - Performed borescope inspection - no degradation 1900 - Vendor representative concurrence with D6 condition ............
- 2331 - Completed TS required fast start test -- 06 declared operable NM~
14
Post-NOED Period
- E-mail from engine vendor stating "suspect there could be incompatibility problem between fuel and lube oil"
- Root cause team forming to evaluate information
- Requested Root Cause Report of Calvert Cliffs incident from BG&E
- Calvert Cliffs report received by PINGP engineer
- Calvert Cliffs report issued to Root Cause team
- D5 and 06 declared inoperable, Unit 2 shut down NMC>
15
Calvert Cliffs Root Cause Reoort
- First reviewed April 30 - May 2
- Identified technical parallels between events
- Problem initially found in one cylinder
- Established mineral - synthetic distinction not relevant to oil incompatibility issue
- Discussed independent analyses and unanimous conclusion of cause
- Provided root cause team with technical bases for oil incompatibility as the potential cause NMC) 16
Statement of Dennis Carlson
- No vendor recommended oil change
- No information indicated oil incompatibility in April 2001
- Limited role in 06 issue and NOEO
- Provided complete and accurate responses NMC) 17
Statement of Scott Hiedeman
- Before reading the full Calvert Cliffs report had concluded oil incompatibility problem would not develop at PINGP because:
- Vendors did not recommend oil change and assured PINGP engines would not experience oil incompatibility
- PINGP used mineral-based rather than synthetic lube oil
- Absence of operating problems, especially during rebuilds
- Potential problems could be detected in preventive maintenance
- April 2001 incident was limited to a single cylinder NM~
18
StatemeoLof _S~9ttJ~i iedemClIl1cont)
- The full Calvert Cliffs report changed view about the potential for an oil incompatibility problem:
- Realized SACM agreed oil incompatibility was root cause for Calvert Cliffs (contrary to statements made by SACM's U.S. representative)
- Realized symptoms of oil incompatibility could develop in a single cylinder
- Realized significance of "Total Base Number" NMC) 19
SIT Document Timeline
- Document removed from SIT production stack
- Document later retrieved by concerned employee
- Concerned employee determines document appears relevant
- Document returned to NRC production process
- Document produced to SIT
- ECP investigation
- ECP manager informs SIT of investigation results and confirms SIT receipt of document
.. ~~
NM~
20
SIT Document Production
- Promptly investigated individual's action
- Reported incident to SIT/Senior Resident
- Ensured SIT had document
- Determined there was no intent to withhold significant information by individual or PINGP NMC) 21
Statement of Scott Hiedeman -- SIT
~,,---- -----------"-----~
- Did not intend to mislead the NRC or withhold information
- Removed the Lube Notes article because thought it was inaccurate and misleading
- Removing the document was an error of judgment NMC) 22
tn
-c s:::
CI.) CI.)
s) ...as tn s::: ...
0
(.)
(1) <C OJ tnl ..J (1)
(1)1 0:1 tn s::: ...
(.)
a.. 0 (1) tn CJ tn 0
-Z a..
(1)
..J 0
tn tn CI) CI)
(.)
r::
C) :::s
-c
-- -r::
CI)
C'"
CI)
C1) '
....tntn .... ....as
'- CI) '- CI) c:: CI) CI) cCI)
(.)
1 a. c m
C1)
..J w>< --
C) r::
CI)
- s E CI)
- s U) c::
C) r::
....m w
E C'"
CI)
(.)
0
-c
-r::
0 0
en '-
CI)
CI) tn C
w 0 -c r::
U) a. ~ 0 a: CI)
CI.)
..J 0 U'J Z Z >
Lessons Learned
- Roles and responsibilities
- Management expectations, standards, accountabi Iities
- Quality validation/verification (QV&V) weaknesses
- Sense of ownership/urgency/follow-through NM~
25
OE Im~rQy~ments_~~_~_~~___
- Developed very comprehensive processes for review of external OE
- Integrated OE into our daily work
- Formed OE oversight process/team NM9 26
-"t-, .~
EngineeriQA~Or~n_~zatiQn Improvements
- Role/responsibility changes
27
N9ED R~~~est Pro~_e_s_s___~___
- Operations Committee Improvements
- Expectations for Site Organization
- Complete and Accurate Information
- Plant Event Investigation and Recovery Process NMC:>
28
NRC Communications
- Verification and Validation Process
- Regulatory Compliance Organization
- Inspection Support Process
- NRC Confidence in our Communication NMC) 29
.,.I
,-I I
C 0
tn ....0 CO
- J C
0 (.) c en --....CO --
c 0
' .... ::::s E
ca
(.)
0 (.)
CD --
'I
-c Q. E '
c: >< 0 CD G) W 0 >
c:
....0 ca C) en .
....CD
- s c:
tn CD c:: ....c
.... en
-c.ca >
c:
ca ca CD Q) CD
.t: tn OJ C) c:
-:::s ca
(.)
c: :::s ca
- a. ... ...CD>
c: -CD CD
(.)
Z
-a.
ca CD
..J 0
0 w
(.)
0 0
a:
Overall Sum_mary______ ______________
- ... PINGP provided NRC with as complete and accurate information as possible
- ... Lack of aggressive OE investigation inhibited root cause analysis and technical conclusions
- ... Prompt action when new information raised questions with initial technical conclusions
- ... PINGP provided all relevant documents to NRC NM9 32
Broader Initiatives
- Management changes
- Staff realignment
- Formal processes
- Clear management expectations, standards, accountabilities
- Process assessment
33
'.f-*. _
Conclusion
~ Actions were not willful violations
~Corrective actions are in place
~NRC enforcement action is not warranted
~Enforcement discretion is warranted NM~
34