LER 79-043/01T-0:on 790906,two of Four Bolts on Hanger 32-GE-S41 Failed During Insp Program.Caused by Improper Installation of Bolt Anchor Shells.Defective Bolts Have Been Removed & Replaced by Wedge Type Anchor Bolts
ML19209A537
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 09/20/1979
From: Colney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19209A532 List:
References
LER-79-043-01T, LER-79-43-1T, NUDOCS 7910040293
Download: ML19209A537 (1)


Text

C FOglM WG (J. h. NUCLE All 64LdUL AI Ols V COMMihS40N

  • 'I)UniC 2 LICENSEE EVENT REPORT Report No. 2-79-h3/1T CONTROL BLOCK. l llllll(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) lP I A PIBlSl2l@lOlOI-IO l OI O! Ol 0 l -l Oi 0 l@l 4 Il1Ill1l@!

I l@1 8 9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE JO

$7 CATSd)N'T.LLI$1URM i L !@l015 1 01 i 012 17 17 !@l 0 l 910 6l719l@loi.)l21017Io @

" 8 M 61 QQCKET NUM8ER Go t>9 EVENT CATE 74?S REPORT OATE 80 EVENT DESCRIPTION AND PROBA8LE CONSEQUENCES h 2 l The insrection procam perfomed in respense to IE Bulletin 79-02 iden-1 2 1 tifled two anchors in one support which had centact between the bolt lPells and the support plate. These anchors are associated with the high I 4 s I pressure service water (EPSW) systes line in the Unit 2 A RER rocm.

I 6 I Even though failure of the eine during a seis=ic event would affect two I 7lEPSV contn4 ent ecoline subsyste=s the safetr siznificance is consider-I.s i ed + 4 m 1 because LPCI and redundant RER subsyste=s are evailable.

I 80 B 9 SYSTEu CAUSE CAUSE COMP.VA LV E CCCE CcQE SUSCCCE COMPONENT CODE SU8 CODE SU8CCCEl Sl El3 3l@C l@ l S l Ul P l0 [R IT lh l Al@ lZ l@

9 8 9 to 11 12 13 18 19 20 SECUE N TI AL CCCURRENCE REPcRT REvtSION_LE RiRO EVENT YEAR REPORT NO.

CcDE TYPE NO.@ 0u'OE 1 01 1719]l-l l o l hi 31 1/l lol11 ITl"-21 22 23 24 26 77 28 29 30 31 32 TA AC C CNP NT MET HOURS S 8 i PC 8.SLPPLI E MANLFA TURER IAl@lZl@lZl@lZl@l0l010l0ll Y l@lN l@y@II l 2 l 0 l 9 [@

21 34 3b 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CCRRECTIVE ACTICNS ito lCentact between the bolt shells and suttert elate was caused bv i=treter I im I installatien of the bolt anchor shells. The defective bolt shells have I i 2i lbeen re=oved and replaced by wedre tvte anchor bolts and have been suc-1 i, lcessfully torcue tested. The resultine ancher belt safety facter attain-lt t4 i ed is greater than 5.

1 W 3 80 STA S% PCWER OTHER STATUS CISC RY OISCOVERY DE3CRIPTION I~~l [_Ej@ l 0 l 9 l 8 l@l N/AllDl@lWork in IE Bulletin 79-02 lmcuNT c, ACTIVITY @

LOCATICN OF RELEASE @

ACTIVITY CO TENT aELE ASin o, RE u ASE I Z I @ I Z l@l N/A i N/A I o% 9 10 ft 44 45 30 Pf 0%ONNf L F XPCT.LRES Nt.;MUE R TYPE DESCRIPTION 17 101010!@lZi@l N/Al'" PE Rsc~N E t iNav'4 ES l (.}g g g f /" "'cESCR,ricN@

.NuM8ER I" l01010l@l N/Al4 9 11 12 80 LCSS OF CH D AMACE TO F ACILITY /"";\

rveE CESCRi, Tion O 79100407- lZl@l N/A I i o e 9 io o 0ESCR., TION @

f NRC USE CNLY

  • '*M , Tr 1 LUut61 N/A// M - ,, I IIiiiiI'IiIi r.s a 1 to y// 7'-]G8 tra 80 ;/N J. Cooney (215) 841-5020
N/.ME OF PREPARER PHONE
o-v