ML19209A532

From kanterella
Jump to navigation Jump to search
Forwards LER 79-043/01T-0
Date released: 08/11/2019 Download: ML19209A532


LER 79-043/01T-0:on 790906,two of Four Bolts on Hanger 32-GE-S41 Failed During Insp Program.Caused by Improper Installation of Bolt Anchor Shells.Defective Bolts Have Been Removed & Replaced by Wedge Type Anchor Bolts
ML19209A537
Person / Time
Site: Peach Bottom 
Issue date: 09/20/1979
From: Colney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19209A537 (1)
Forwards LER 79-043/01T-0
ML19209A531
Person / Time
Site: Peach Bottom 
Issue date: 09/20/1979
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19209A531 (2)