Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
05000461/LER-1988-016, Forwards LER 88-016-00 Re Failure to Recognize Location & Extent of Penetration Seal Repair Results in Violation of Secondary Containment Integrity17 June 1988Forwards LER 88-016-00 Re Failure to Recognize Location & Extent of Penetration Seal Repair Results in Violation of Secondary Containment IntegrityFire Barrier
Fire Watch
Hourly Fire Watch
JSP-676-90, Responds to 900725 Notice of Violation & Proposed Imposition of Civil Penalty Documented in Insp Rept 50-461/90-09. Corrective Action:Critique Initiated to Identify Precise Causes & Contributing Factors Leading to Event23 August 1990Responds to 900725 Notice of Violation & Proposed Imposition of Civil Penalty Documented in Insp Rept 50-461/90-09. Corrective Action:Critique Initiated to Identify Precise Causes & Contributing Factors Leading to Event
JSP-739-90, Requests Expedited Review & Approval of Proposed Change to Emergency Tech Specs Re Div III Nuclear Sys Protection Sys Inverter Concerning Inoperability of Emergency Shutdown Svc Water Sys Pump12 September 1990Requests Expedited Review & Approval of Proposed Change to Emergency Tech Specs Re Div III Nuclear Sys Protection Sys Inverter Concerning Inoperability of Emergency Shutdown Svc Water Sys PumpSafe Shutdown
ML17276A1762 November 1981Forwards Minutes from Mechanical Engineering Branch 810929-30 & 1001 Meetings in Woodbury,Ny & 811016 Preservice Insp Meeting in Washington,Dc.Agenda Items from Both Meetings & Subsequent Resolution Encl
ML17299B32518 November 1985Provides Addl Info Re Behavior of Floor Grating Inside Containment Bldg Following Loca.Analyses Completed Since Insp Confirm Postulated Jet Impingement Loads on Floor Grating Will Not Preclude Safe ShutdownSafe Shutdown
ML18023A06110 July 1986Requests Change to Final Draft Tech Spec Tables 3/4 3.7.12-1.Change Involves Disabling high-range Iodine Monitoring Channel of Both Standby Gas Treatment Sys Exhaust sys-level Particulate Iodine & Noble Gas Monitors
ML19208B17115 August 1979Responds to NRC 790719 Ltr Re Violations Noted in IE Insp Rept 50-461/79-06.Corrective Actions:Baldwin Associates Receiving Insp Instruction Revised to Include Documentation of Physical Damage to Structural Steel for Correction
ML19208D02120 August 1979Responds to IE Bulletin 79-03 Re Longitudinal Weld Defects in ASME SA-312 Type 304 Stainless Steel Pipe Spools Mfg by Youngstown Welding & Engineering Co.Pipe Is Not in Use in safety-related Sys at Facility
ML19208D13726 July 1979Responds to IE Bulletin 79-11, Faulty Overcurrent Trip Device in Circuit Breakers for Engineered Safety Sys. Westinghouse Circuit Breakers DP-75 & DO-50 Will Not Be Used w/safety-related Sys
ML19210E2891 December 1979Forwards Physical Security Plans & Safeguards Contingency Plan.Plans Withheld (Ref 10CFR2.790)
ML19210E66030 November 1979Requests Approval for Use of ASME Code Case N-240 to Exempt Certain Piping from Hydrostatic TestingUltimate heat sink
Hydrostatic
ML19242B25229 May 1979Responds to IE Bulletin 79-07 Re Seismic Analysis Computer Codes.Discusses Verification of Piping Computer Programs in Use
ML19246B94829 May 1979Responds to IE Bulletin 79-04 Re Improper Weights for Check Valves Mfg by Velan Engineering.No Velan Check Valves Are Used
ML19247A79429 May 1979Responds to IE Bulletins 78-12,12A & 12B, Atypical Weld Matl in Reactor Pressure Vessel Welds. Encl 790424 Ltr by CB&I Reports No Weld Deviations for Unit 1.Unit 2 Vessel Fabrication Is Incomplete
ML19247B38815 June 1979Responds to NRC 790509 Ltr Re Violation Noted in IE Insp Rept 50-461/79-03.Corrective Actions:Concrete Vibrators Tested
ML19248D25520 July 1979Supplements Response to IE Bulletin 79-02.IL Power Co, Comm Ed & Three Other Utils Are Presently Testing Expansion Anchors.Resulting Data Will Be Used to Ensure Proper Design
ML19249A93126 July 1979Responds to IE Bulletin 79-11.Westinghouse DB-75 & DB-50 Circuit Breakers Not Used w/safety-related Svcs
ML19250C20431 October 1979Responds to NRC 790912 Ltr Forwarding IE Bulletin 79-23 Re Problem Encountered W/Diesel Generator Excitation Power Transformers.Excitation Power Transformers Will Be Operated W/Floating Primary Neutrals
ML19254B4374 September 1979Responds to IE Bulletin 79-14, Seismic Analyses for As-Built Safety-Related Piping Sys. Results of Insp Would Provide Little Useful Info Due to Limited Amount of Piping Installed to Date.Will Submit Amend to FSAR
ML19257B27111 January 1980Forwards Updated Const Schedule & Revisions to Const Logic. Completion of 62% Expected 791231 & Fuel Loading Expected in Apr 1982.Oversized Milestone Schedule in Central Files Only
ML19257B6493 January 1980Responds to IE Bulletin 79-25, Failures of Westinghouse Bfd Relays in Safety-Related Sys. No Such Relays Will Be Used at Facility
ML19259C25010 May 1979Advises That Response to IE Bulletin 79-03, Longitudinal Weld Defects in ASME SA-312 Type 304 Stainless Steel Pipe Spools, Will Be Submitted by 791231
ML19260G30017 September 1980Forwards Proprietary Info for Fsar.Includes Info Re Initial Core Fuel Design for Use of Gadolinia & Offgas Sys Technology.Affidavit for Withholding Encl.Info Available in Central Files Only
ML19263C31012 January 1979Responds to NRC 781215 Ltr Re Violations Noted in IE Insp Rept 50-461/78-06.Corrective Actions:Developed Written Procedure for Operation of Husky'S Spot Welding Process, Calibr Gauges & Instruments
ML19282B64514 February 1979Responds to NRC 790112 Ltr Re Violation Noted in IE Insp Rept 50-46l/78-06.Corrective Actions:Supplier Instructed in Welding Requirements & Will Establish Calibr Program
ML19284A7007 March 1979Forwards Info Re Potential Reportable Const Deficiency Concerning Defective Welds in Drywell Wall Platework.Welds Have Been Repaired;Reportable Occurrence Rept Will Not Be Submitted
ML19289E94715 March 1979Notifies of Proposed Reactor Pressure Vessel Mod.Ge Authorized to Act as Agent for Performance of Work Which Will Be Subcontracted to Reactor Controls,Inc.Work to Begin 790319
ML19290C5194 January 1980Responds to IE Bulletin 79-02,Revision 2, Pipe Support Base Plate Designs Using Concrete Expansion Anchor Bolts. Util Procedure for Installing Wedge Type Anchor Bolts Approved Approx Two Wks Ago
ML19290D93027 February 1980Forwards Annual Financial Rept 1979.
ML19291B0935 July 1979Forwards Response to IE Bulletin 79-02 & 02,Revision 1 Action Items Re Structural Failures of Piping Supports for Safety Equipment
ML19294B4407 February 1980Responds to IE Bulletin 79-28 Re Namco Model EA180 Limit Switches.Investigations Show No Switches Received.Vendor Checking Not Yet Completed
ML19296B20115 January 1980Submits Suppls to 791226 & 27 Response to Notice of Violation & IE Insp Rept 50-461/79-11 & 50-462/79-01.Program for Training,Evaluation & Testing of Civil Matls Testing Personnel Is Now More Formally Documented
ML19296B20426 December 1979Responds to NRC 791227 Ltr Re Violations Noted in IE Insp Repts 50-461/79-11 & 50-462/79-01.Corrective Actions:Future Us Testing Certification Will Clearly Show Status of Individuals Under Restricted or Limited Qualifications
ML19296C66818 February 1980Requests Approval for Use of ASME Code Cases N-237 & N-241 to Exempt Piping from Hydrostatic TestingHydrostatic
ML19305A86714 March 1980Informs That Util Plans to Submit Petition to Il Pollution Control Board Requesting Mod of 1975 Alternate Thermal Std. Outlines Factors Mitigating Need for 96 F Limit.Requests Comments
ML19305A92312 March 1980Comments on NUREG-0313,Revision 1, Technical Rept on Matl Selection & Processing Guidelines for BWR Coolant Pressure Boundary Piping. Challenges Prohibition of Carbon Steel in Reactor Pressure Boundary.Cast Stainless Steel Is Resistant
ML19305B83413 March 1980Requests That NRC Expedite Review & Approval of Proposed Changes to Environ Preoperational Monitoring Program,As Discussed in 800228 Telcon.Late Apr Deadline Requested
ML19305D15124 March 1980Responds to IE Bulletin 79-09, Failures of GE Type AK-2 Circuit Breaker in Safety-Related Sys. GE Type AK-2 Circuit Breakers Will Not Be Used with Any safety-related Svcs at Facility
ML19305D52124 March 1980Responds to IE Bulletin 80-03 Re Charcoal Adsorber Cells. Liscensee Does Not Use Adsorber Trays Discussed in Bulletin But Uses Vertical Gasketless Adsorbers Mfg by American Air Filter Co
ML19309A75024 March 1980Forwards Comments on NUREG-0588, Interim Staff Position on Environ Qualification of Safety-Related Electrical Equipment, in Response to NRC 800205 Ltr.Certain Sections Need Revision & ClarificationCoatings
ML19309A77824 March 1980Submits Evacuation Time Estimates,In Response to NRC 800226 Ltr.Map of Area Encl
ML19310A8736 June 1980Responds to NRC 800514 Ltr Re Violations Noted in IE Insp Rept 50-461/80-08.Corrective Actions:Removed All Scrap Matl from Designated Reject/Hold Area & Verified Appropriate Boundary Markers
ML19318C01819 June 1980Requests Extension of Time for Submittal of Security Guard Training & Qualification Program Until Dec 1980.Previously Tendered Security Plan Matl Has Been Accepted for Docketing
ML19320A55722 May 1980Responds to NRC 800425 Ltr Re Violations Noted in IE Insp Rept 50-461/80-04.Corrective Actions:Sargent & Lundy Design Drawing Will Be Revised to Identify 480-volt Switchgear Holes to Be Welded to Embedded Angle Iron
ML19320C3028 July 1980Forwards Deficiency Repts Inadvertently Sent to Region 3 Instead of IE Headquarters
ML19320D55817 June 1980Responds to NRC 800520 Ltr Re Violations Noted in IE Insp Rept 50-461/80-06.Corrective Actions:Inspectors Reinstructed on Visual Insp & Bend Test Requirements
ML19321B0762 July 1980Advises NRC That Util Is Planning Repairs to Reactor Pressure Vessel.Ge Has Been Authorized to Perform Work, Which Has Been Subcontracted to Reactor Controls,Inc. Defective Elbow on Reactor Drain Line Will Be Replaced
ML19323B03021 April 1980Responds to IE Bulletin 80-02, Inadequate QA for Nuclear Supplied Equipment. Unit 1 Feedwater Spargers & Thermal Sleeves Are Fabricated by Chicago Bridge & Iron Nuclear. Spargers Were Purchased in May 1977
ML19323B78826 March 1980Responds to NRC 800226 Ltr Re Violations Noted in IE Insp Rept 50-461/80-02.Corrective Actions:Revision to Calibr Procedure for Obsolete Documents Is Being Used in Calibr Lab
ML19323F21523 May 1980Forwards Info for Antitrust Review of OL Application Per 800204 Request