SVPLTR 10-0037, 2011 Dresden Nuclear Power Station Initial Examination Outline Submittal

From kanterella
Revision as of 20:06, 12 November 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
2011 Dresden Nuclear Power Station Initial Examination Outline Submittal
ML111510572
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 09/23/2010
From: Hanley T
Exelon Generation Co, Exelon Nuclear
To:
Region 3 Administrator
Shared Package
ML11104A075 List:
References
SVPLTR: #10-0037
Download: ML111510572 (20)


Text

2011 DRESDEN NUCLEAR POWER STATION INITIAL EXAMINATION OUTLINE SUBMITTAL

Exelon Generation Company, LLC Dresden Nuclear Power Station www.exeloncorp.com Nuclear 6500 North Dresden Road Morris. IL 60450-9765 September 23,2010 SVPLTR: #lo-0037 Regional Administrator, Region Ill U. S. Nuclear Regulatory Commission 2443 Warrenville Road Lisle, IL 60532-4352 Dresden Nuclear Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-19 and DPR-25 Docket Nos. 50-237 and 50-249

Subject:

Submittal of Initial Operator Licensing Examination Outlines Enclosed are the examination outlines, supporting the initial license exam scheduled for the weeks of March 07,201 1 through March 18, 2011 at Dresden Nuclear Power Station.

This submittal includes all appropriate examination standard forms and outlines in accordance with NUREG-1021, Operator Licensing Examination Standards, revision 9 supplement 1.

In accordance with NUREG 1021, revision 9, supplement 1, Section ES-201, Initial Operator Licensing Examination Process, please ensure that these materials are withheld from public disclosure until after the examinations are complete.

Should you have any questions concerning this letter, please contact Dennis Leggett, Regulatory Assurance Manager, at 815-416-2800. For questions concerning examination outlines, please contact Mr. Frank Ferrero at 815-416-2620.

Respectfully, Tim Hanky Site Vice President Dresden Nuclear Power Station

Enclosures:

(Hand delivered to Chief Examiner Region 111)

Examination Security Agreements (Form ES-201-3)

Administrative Topics Outline (Form ES-301-1)

Control Room/ln-Plant Systems Outline (Form ES-301-2)

BWR Examination Outline (Forms ES-401-1)

Generic Knowledge and Abilities Outline (Tier 3) (Form ES-401-3)

Statement Detailing method of Written Exam Outline Generation Scenario Outlines (Form ES-D-1)

Record of Rejected WAS (Form ES-401-4)

Completed Checklists:

Examination Outline Quality Checklist (Form ES-201-2)

Transient and Event Checklist (Form ES-301-5) cc: (without enclosures)

Chief, NRC Operator Licensing Branch NRC Senior Resident Inspector - Dresden Nuclear Power Station

ES-201 Examination Outline Quality Checklist Form ES-201-2 Facility: Dresden Date of Examination: -

3 7-/

I Item I Task Description I Initials Tp 1.

... I a. Verify that the ouline(s) fit(@the appropriate model, in accordancewith ES-401.

RI T

~

b. Assess whether the outline was systematically and randomlyprepared in accordancewith Section D.l of ES-401 and whether all WA categories are appropriately sampled. p-T E
c. Assess whether the outline over-emphasizesany systems, evolutions, or generic topics. P-N d. Assess whether the justificationsfor deselected or rejected WA statementsare appropriate.
a. Using Form ES-301-5,verify that the proposed scenario sets cover the requirednumber of normal evolutions, instrument and componentfailures, technical specifications, and major transients.
b. Assess whether there are enough scenario sets (andspares) to test the projectednumber and mix of applicants in accordance with the expectedcrew composition and rotation schedule without compromisingexam integrity, and ensure that each applicant can be tested using at least one new or significantlymodifiedscenario, that no scenarios are duplicated from the applicants audit test@),and scenarios will not be repeated on subsequent days.

limits specifiedon the form

a. Author
b. Facility Reviewer c)
c. NRC Chief Examiner (#)

NOTE: # IndependentNRC Reviewer initial items in Column c; chief examiner concurrence required.

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Dresden . Date of Examination: 3/7/11 Examination Level: RO SRO 0 Operating Test Number: 10-1 (2011-301)

Administrative Topic Type Describe activity to be performed (SeeNote) I Code*

Perform Calculated Drywell Leak Rate Conduct of Operations Generic.2.1.I8 Perform Off-Site Power Sources Available Conduct of Operations Generic.2.1.31 Verify Reversal Of EDG Cooling Water Flow Surveillance Equipment Control D, S Generic.2.2.12 Perform CCSW Activity Calculation Radiation Control Generic.2.3.11 Emergency Plan VOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.

' Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank (1.3 for ROs; f4 for SROs & RO retakes)

(N)ew or (M)odified from bank (11)

(P)revious 2 exams 1; randomly selected)

ES 301,Page 22 of 27

ES-301 Ad minist rat ive Topics 0utI i ne Form ES-301-1 Facility: Dresden Date of Examination: 3/7/11 Examination Level: RO 0 SRO Operating Test Number: 10-1 (2011-301)

Administrative Topic Type Describe activity to be performed (See Note) Code*

Reportability Determination Conduct of Operations N, S Generic.2.1.2 Review Off-Site Paperwork Sources Available Conduct of Operations Generic.2.1.31 Review Calculated Drywell Leakrate And Identify Tech Equipment Control Specs Generic.2.2.40 Perform CCSW Activity Calculation Radiation Control Generic.2.3.11 Authorize Use Of KI Emergency Plan Generic.2.4.40 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when 5 are required.

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank (I3 for ROs; 5 4 for SROs & RO retakes)

(N)ew or (M)odified from bank (2 1)

(P)revious 2 exams (5 1; randomly selected)

ES 301,Page 22 of 27

ES-301 Control Room/ln-Plant Systems Outline Form ES-301-2 Facility: Dresden Date of Examination: 317111 Exam Level: RO SRO-I SRO-U 0 Operating Test Number: 10-1 (2011-3011 I Control Room Systems@(8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

Safety System I JPM Title Type 'Ode*

Function

a. SBLC - Injection With RWCU Isolation Failure (211000.A4.08) A, M, s 1
b. CORE SPRAY - Perform Pump Test, With Pump Trip (209001.A4.01) A, D, L, P, S 2 I c. DEHC - Establish RPV Cooldown With Bypass Valves (241000.A4.06) I D, L, S I 3.
d. LPCl - Mitigate High Suction Pressure While Lining Up To CST For A, D, L, S 4 Injection (203000.A4.02)
e. CONTAINMENT -Vent The Torus With Level Less Than 30 Feet A, D, s 5 (295024.A1.14\
f. AUX POWER - Transfer To TR-22 From TR-21, With Breaker Failure D, s 6 (262001.A4.04)
g. RWM - Enter Substitute Rod Position (201006.A4.06) D, S 7
h. OFF GAS - Align Charcoal Adsorber Filters In Series Mode N, L, S 9 (271000.A4.09)

In-Plant Systems@(3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. SBLC - Lineup SBLC Test Tank For Alternate Water Injection D, E, R 2 (295031.Al.O8)
j. EDG - Manually Fill Unit 213 EDG Day Tank (264000.G.2.1.30) D, R 6
k. HVAC - Valve In Control Room Emergency Breathing Air (600000.A2.10) D 8

@ All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO I SRO-I I SRO-U '

(A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank -< 9 158 154 (E)mergency or abnormal in-plant ->1 1 2 1 1 2 1 (EN)gineered safety feature - I - I 2 1 (control room system)

(L)ow-Power I Shutdown -> I 1 2 1 1 2 1 (N)ew or (M)odified from bank including 1(A) -> 2 1 2 2 11.1 (P)revious 2 exams - 3 I 5 3 I 5 2 (randomly selected)

(WA -> I 1 2 1 1 2 1 (S)imulator ES-301, Page 23 of 27

ES-301 Control Room/ln-Plant Svstems Outline Form ES-301-2 Facility: Dresden Date of Examination: 317111 Exam Level: RO 0 SRO-I SRO-U Operating Test Number: 10-1 (201 1-3011 I Control Room Systems@(8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF) I Safety System I JPM Title Type Ode* Function

a. SBLC - Injection With RWCU Isolation Failure (21 1000.A4.08) A, M, S 1
b. CORE SPRAY - Perform Pump Test, With Pump Trip (209001.A4.01) A, D, L, P, S 2 I c. DEHC - Establish RPV Cooldown With Bypass Valves (241000.A4.06) 1 D, L, S I 3 I
h. OFF GAS - Align Charcoal Adsorber Filters In Series Mode N, L, S 9 (271000.A4.09)
i. SBLC - Lineup SBLC Test Tank For Alternate Water Injection D, E, R 2 (295031.AI .08)
j. EDG - Manually Fill Unit 213 EDG Day Tank (264000.G.2.1.30) D, R 6 I k. HVAC - Valve In Control Room Emergency Breathing Air (600000.A2.10) 1 D 1 8 I
  • Type Codes Criteria for RO I SRO-I I SRO-U (A)lternate path 4-6 I 4-6 I 2-3 (C)ontrol room (D)irect from bank -< 9 158 154 (E)mergency or abnormal in-plant -> I 12.1 1 2 1

~ (EN)gineered safety feature - I - I 1. 1 (control room system)

(L)ow-Power I Shutdown -> I 121 / ? I 1 (N)ew or (M)odified from bank including 1(A) -> 2 122 I 1 1 (P)revious 2 exams -3 I 5 3 I 5 2 (randomlyselected)

(WCA -> I 12.1 12.1 (S)imulator ES-301, Page 23 of 27

tS-301 I ransient and tvent ChecklistForm tS-301-5

--

acility: Dresden Date of Exam: 3/7/11 Scenarios Operating Test Number: 10-1 (2011-301)

A E P V 1 M P E L N CREW I T POSITION POSITION POSITION T N C A I A T L M N Y R T O R T O U T P E

RX NOR

RO-I I/C 11 MAJ TS RX NOR
RO-I I/C

!2 MAJ TS Rx NOR 10 I/C

I MAJ TS Rx NOR I/C MAJ

- -

TS nstruci Ins:

1. Check the a licant level and enter the operating test number and Form ES-D-1 event numbers for each event ty e; f8 are not ap licable for RO applicants. ROs must serve in both the at-the-controls (ATC) and baknce-of- lant(B8P) positions. Instant SROs must serve in both the SRO and. the ATC positions, including at leasrtwo instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionallyserves in the BOP position, one I/C malfunction can be credited oward the two I/C malfunctions required for the ATC position.

?. Reactivit mani ulations may be conducted under normal or controlled abnormal conditions (refer to 3.

r Section A.5.d) {ut must be significant.per Section C.2.a of Appendix D. ) Reactivity and normal evolutions may be replaced with additional instrument or component mal unctions on a I-for-I basis.

Whenever practical, both. instrument and component malfunctions should be included; only those that require verifiable actions that provide insight.to the applicants com etence count toward the minimum requirements specified for the applicants license level in &e right-hand columns.

ES-301, Page 26 of 27 tS-301 Transient and tvent Checklistkorm tS-301-5

-

acility: Dresden Date of Exam: 3/7/11 Scenarios Operating Test Number: 10-1 (2011-301)

A P V 1 2 3 P E M 0 I L

I N

T 1 CREW POSITION 1 CREW POSITION CREW POSITION T N J

I C

A T M N 0 0 U Y

T P E

-

1. Check the a licant level and enter the operating test number and Form ES-D-1 event numbers for each event ty e. f.8 are not ap licablefor RO applicants. ROs must seye in both the at-the-controls (ATC) and pafanhe-of- lantjB8P) positions. Instant SROs must serve in both the SRO and. the ATC positions, including at leasrtwo instrument or component ( K ) malfunctions and one major transient, in the ATC position. If an Instant SRO addifional!y serves in the BOP position, one I/C malfunction can be credited oward the two I/C malfunctions required for the ATC position.
2. Reactivit manipulations may be conducted under normal or controlled abnormal conditions (refer to 3.

r Section J.5.d) but must be significant.per Section C.2.a of Appendix D. ) Reactivity and normal evolutions may be replaced with additional instrument or component mal unctions on a I-for-I basis.

Whenever practical, both. instrument and component malfunctions should be included; only those that require verifiable actions that provide insight.to the applicants com etence count toward the minimum requirements specified for the applicants license level in t f e right-hand columns.

ES-301, Page 26 of 27 tS-301 lransient and tvent Checklist korm tS-301-5

-acility: Dresden Date of Exam: 3/7/11 Operating Test Number: 10-1 (2011-301)

A E Scenarios P v 1 2 3 P E L

I N

T CREW POSITION CREW POSITION I CREW POSITION I C

A T N Y T P E

Rx NOR SRO-l IIC

$5 MAJ TS Rx NOR SRO-l I/C Y6 MAJ TS Rx NOR 30 IIC P3 MAJ TS Rx NOR I/C MAJ

-- TS Instrucl Ins:

1. Check the a licant level and enter the operating test number and Form ES-D-1 event numbers for each event ty e; f8 are not ap licablefor RO applicants. ROs must serve in both the at-the-controls (ATC) and bagnce-of- lant(B8P) positions. Instant SROs must serve in both the SRO and. the ATC positions, including at leasrtwo instrument or component (VC) malfunctions and one major transient, in the ATC position. If an Instant SRO addifiona/!yserves in the BOP position, one I/C malfunction can be credited oward the two I/C malfunctions required for the ATC position.
2. Reactivit manipulations may be conducted under normal or controlled abnormal conditions (refer to f

Section J.5.d) but must be significant,per Section C.2.a of Appendix D. ) Reactivity and normal evolutions may be replaced with additional instrument or component mal unctions on a l-for-I basis.

3. Whenever practical, both. instrument and component malfunctions should be included: only those that require verifiable actions that.provide insight.to the applicants com etence count toward the minimum requirements specified for the applicants license level in &e right-hand columns.

ES-301, Page 26 of 27 kS-301 Transient and Event Checklist korm ES-301-5 Dresden Date of Exam: 3/7/11 Operating Test Number: 10-1 (2011-301)

E Scenarios V

E 1 2 I I

3 I I

I N CREW CREW CREW T POSITION POSITION POSITION T

Y P

E NOR I/C MAJ I/C MAJ rs w

VOR IC MAJ rs w

UOR VlAJ

-

rs ns:

1. Check the a licant level and enter the operating test number and Form ES-D-1 event numbers for each event ty e; f8 are not ap licablefor RO applicants. ROs must serve in both the at-the-controls (ATC) and baLnce-of- lant(B8P) positions. Instant SROs must serve in both the SRO and. the ATC positions, including at leasrtwo instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited oward the two I/C malfunctions required for the ATC position.
2. Reactivit manipulations may be conducted under normal or controlled abnormal conditions (refer to 3.

r Sectiqn J.5.d) but must be siqnificant.per Section C.2.a of Appendix D. ) Reactivity and normal evolutions may be replaced with additional instrument or component mal unctions on a I-for-I basis.

Whenever practical, both. instrument and component malfunctions should be included; only those that require verifiable actions that.provide insight. to the applicants competence count toward the minimum requirements specified for the applicants license level in the right-hand columns.

ES-301, Page 26 of 27 ES-401 2 Form ES-401-1 95024 High Drywell Pressure / 5 Emergency generators Suppression pool level Protectionof the general public

TQ-AA-151-F10 Revision 0 Paqe 1 of 1 Scenario Outline I Station: Dresden Generating Station Scenario No.: ILT-N-1 Class ID: 10-01 (2011-301)

I Evaluators Operators I crew position I ATC I BOP I CRS Initial Conditions: Initial Power = 75%

Turnover:

Malf. Event Event No. -

le* DescriDtion RDFAILF5 I ATC CRD - RPlS failure for rod F-05.

Q22 C BOP SERV WATER - Pump Trip.

ICSPDFT I BOP IS0 COND - Inadvertent Initiation.

NONE C ATC RFP - 2B RFP Develops an Oil Leak / Must Swap.

Manual Scram - Earthquake Causes Plant Damage and CSBRKSEV M TEAM Subsequent Torus Leak.

_ _ _ ~

EMERGENCY DEPRESSURIZE - Torus ECCS Suction CSBRKSEV M TEAM Line Break / ED due to Lowering Torus Level.

  • (N)orrr , (R)eactivity, (1)i trument it, (M)ajor, (T)ech Spec SRRS: 3D.105

TQ-AA-151-F10 Revision 0 Paqe 1 of 1 Scenario Outline Station: Dresden Generating Station Scenario No.: ILT-N-2 Class ID: 10-01 (2011-301; Evaluators Operators / crew position I ATC I BOP I CRS Initial Conditions: Initial Power = 80%

Turnover: Lower Reactor Power with Recirc Event No.

1 2

3 Malf.

No.

NONE HPlNlT RRMBBIAS

  • Event Event Descrbtion RECIRC - Lower Reactor Power using Recirculation Flow.

HPCl - Spurious HPCl Initiation.

RECIRC - Individual Pump Controller Signal Fails Downscale.

4 NONE N 1 BOP HVAC - Swap Reactor Building Supply Fans.

5 RLLMLS I 1 ATC FW - FWLC Controller Drifts High.

6 121 M 1 TEAM Manual Scram - Steam Leak in the Drywell.

121 EMERGENCY DEPRESSURIZE - Steam Leak inside the 7 K23 M TEAM Drywell / Loss of Bus 23-1 & 28 / ED due to Exceeding K40 Primary Containment Pressure.

-

  • (N)orrr , (R)eactivity, (I) trument, (C)omponent, (M)ajor, (T)ech Spec SRRS: 3D.105

TQ-AA-151-F10 Revision 0 Paae 1 of 1 Scenario Outline I Station: Dresden Generatinq Station Scenario No.: ILT-N-3 Class ID: 10-01 (201 1-301)

I EvaIuato rs Operators I crew position

/ BOP I CRS Initial Conditions: Initial Power = 5%

Turnover: Shutdown the U2 EDG per DOS 6600-01 Malf. Event Event No.

-

)e* Description EDG - Shutdown the U2 EDG Following Surveillance NONE N BOP Testing.

ADS3CBN C BOP ERV - Spurious ERV Opening.

ADS3CSD

~~

RDFCFHI C ATC CRD - Indicated Flow to CRD Flow Controller Fails High.

B15 NBI - B Med Range Level lnst Fails Low with Partial Half I ATC NVMl OOBP Scram.

RDPPATRP C ATC CRD - CRD Pump 2A Trip.

43 1 M TEAM Manual Scram - Loss of all Service Water.

AT5 NVMl OOBP FLOODING - Loss of RPV Level Indication Due to Loss of NVML29AP M TEAM NVML29BP Instrument Power And Transmitter Failures NVMLI 12P

  • (N)orm , (R)eactivity, (I)r irumeni :C)omponent, (M)ajor, (T)ech Spec SRRS: 30.105