Text

ACCELERATED D UTION DEMON TION SYSTEM I REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)ACCESSION NBR:9003150446 DOC.DATE: 90/03/08 NOTARIZED:

YES FACIL:50-335 St.Lucie Plant, Unit 1, Florida Power 6 Light Co.AUTH.NAME AUTHOR AFFILIATION GOLDBERG,J.H.

Florida Power&Light Co.RECIP.NAME RECIPIENT'FFILIATION Document Control Branch (Document Control Desk),DOCKET g 05000335

SUBJECT:

Application for amend to License DPR-67,revising Tech Specs for subj proposed license amend,per 890503 ltr.DISTRIBUTION CODE: B054D COPIES RECEIVED:LTR 1 ENCL i SIZE: TITLE: OR Submittal:

Steam Generator Sleeving Review for PWR's NOTES: RECIPIENT I D CODE/NAME PD2-2 LA NORRIS,J INTERNAL: ACRS NRR/DET/ECMB 9H NRR/DST/SPLB 8D NUDOCS-ABSTRACT OGC/HDS2 RES/DSIR/EIB EXTERNAL'PDR NSIC COPIES LTTR ENCL 1 0 1 1 6 6 1 0 1 0 1 1 1 1 1 1 1 1.1 1 RECIPIENT ID CODE/NAME PD2-2 PD AEOD NRR/DOEA/OGCB11 NRR/PMAS/ILRB12-M REG FI E 01 NRC PDR COPIES LTTR ENCL 3 3 1 1 1 0 1 0 1'0 1 1 1 1 NO'IE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!CONTACI'HE.DOCUMENI'ONTROL DESK, ROOM Pl-37 (EXT.20079)TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISIS FOR DOCUMENTS YOU DON'T NEEDI TOTAL NUMBER OF COPIES REQUIRED: LTTR , 24 ENCL 18 H j 1 I t~t<l , l~'1 I l~~,7 E I

~'.O.Box14000,Juno Beach, FL 33408-0420 MARCH 0 8 39SO L-90-76 10 CFR 50.90 U.S.Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.20555 Gentlemen:

Re: St.Lucie Unit 1 Docket No.50-335 Proposed License Amendment Steam Generator Sleevin TAC No.73328 By letter L-89-140, dated May 3, 1989, Florida Power 6 Light Company (FPL)proposed to amend the St.Lucie Unit 1 Technical Specifications to permit repair of steam generator tubes by the installation of either Westinghouse or Combustion Engineering mechanical sleeves.In a telephone conversation on June 2, 1989, the NRC stated that it found the subject license amendment generally acceptable.

Subsequent to the June 2, 1989, telephone conversation, FPL and the NRC have held several discussions on the format and content of the revised Technical Specifications.

As a result of these discussions, FPL proposes the attached revised Technical Specifications for the subject proposed license amendment.

The attachment supersedes the proposed marked-up Technical Specifications of Attachment 1 to FPL's L-89-140 letter.If you have further questions on this topic, please contact us.Very truly yours, J.H.Goldberg Executive Vice President JHG/EJW/tbj Attachment CC Stewart D.Ebneter Regional Administrator, Region II, USNRC, Jacob Nash, Florida Department of Health and Rehabilitative Services Senior Resident Inspector, USNRC, St.Lucie Plant~0031 Qpgp(c+0030 P R AQOCK P500033+PDC an FPL Group company STATE OF FLORIDA))ss~COUNTY OF PALM BEACH)J.H.Goldber being first duly sworn, deposes and says: That he is Executive Vice President, of Florida Power 6 Light Company, the Licensee herein;That he has executed the foregoing document;that the statements made in this document are true and correct to the best of his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.J.H.Gol erg Subscribed and sworn to before me this Notary Pub1ic,'State of Florida h$y Commission Expires lone 1, 1993 rondad rfrru Troy fain~Inruranca Inc.NOTARY PUBLIC, in and he County of., Palm Beach, State of Florida My Commi.ssion expires i).,

s~