ML18047A333

From kanterella
Revision as of 21:19, 17 June 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Forwards Revision 5 to EM-09-04, Inservice Testing of Selected Safety-Related Pumps, Per 811027 Ltr
ML18047A333
Person / Time
Site: Palisades Entergy icon.png
Issue date: 05/20/1982
From: Johnson B
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML18047A334 List:
References
NUDOCS 8205250200
Download: ML18047A333 (1)


Text

  • consumers Power company General Offices: 1945 West Parnell Road, Jackson, Ml 49201 * (517) 788-0550 May 20, 1982 Dennis M Crutchfield, Chief Operating Reactors Branch No 5 Nuclear Reactor Regulation US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 -LICENSE DPR-20 -PALISADES PLANT -INSERVICE PUMP TESTING PROCEDURES As per letter dated October 27, 1981, the Consumers Power Palisades Plant is updating its inservice pump testing program to comply with requirements of the ASME B&PV Code Section XI, 1977 edition with Addenda through Summer 1979. This is done in accordance with 10 CFR 50.55a. A telephone conversation with the NRC brought to the attention of Consumers Power Company that al though relief requests from certain code i terns relating to pump testing had been submitted; a complete description of the procedures for inservice testing of selected safety-related pumps had not. An updated
  • copy of these procedures, EM-09-04, is enclosed.

Brian D Johnson Senior Licensing Engineer CC Administrator, Region III, USNRC NRC Resident Inspector

-Palisades Attachment

-11 pages


0 8..,05 8 2os2so 0 2cg 0500 0255 PDR AD PDR p