Safety Evaluation Report with Open Items Related to the License Renewal of Susquehanna Steam Electric Station, Units 1 and 2
ML090440374
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 03/13/2009
From: Holian B E
Division of License Renewal
To: Spence W H
Susquehanna
Gettys Evelyn, NRR/DLR/RLRA 415-4029
References
TAC MD3698
Download: ML090440374 (6)


Text

March 13, 2009 Mr. W. H. Spence Vice President and Chief Nuclear Officer PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467

SUBJECT:

SAFETY EVALUATION REPORT WITH OPEN ITEMS RELATED TO THE LICENSE RENEWAL OF SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2

Dear Mr. Spence:

By letter dated September 13, 2006, PPL Susquehanna, LLC, submitted, for the U.S. Nuclear Regulatory Commission's (NRC) review, an application to renew the Susquehanna Steam Electric Station (SSES), Units 1 and 2, operating license for up to an additional 20 years. The license renewal application (LRA) was submitted pursuant to Title 10 of the Code of Federal Regulations Part 54, "Requirements for Renewal of Operating Licenses for Nuclear Power Plants." The staff determined that the LRA was complete and acceptable for docketing on October 30, 2006.

The staff reviewed the SSES LRA and developed the enclosed "Safety Evaluation Report With Open Items related to the License Renewal of Susquehanna Steam Electric Station, Units 1 and 2," hereinafter referred to as the Safety Evaluation Report (SER). This SER reflects the status of the staff's review of the LRA, requests for additional information (RAIs), the applicant's responses to the staff's RAIs, and other questions related to the LRA through December 2008, unless otherwise noted. Issuance of the enclosed SER is an important milestone for both the applicant and the staff.

In accordance with the schedule for completing the review of the SSES LRA, the applicant is requested to review the enclosed SER, verify its accuracy, and provide comments to the staff by May 5, 2009. The staff plans to review the current content and format of the SER for further improvement, while incorporating the applicant's comments. Upcoming milestones for this project include an Advisory Committee on Reactor Safeguards meeting on April 1, 2009, and a final SER which is currently scheduled to be issued on or about August 28, 2009.

W. Spence If you have any questions regarding this matter, please contact the license renewal project manager, Evelyn Gettys, at 301-415-4029 or by e-mail at evelyn.gettys@nrc.gov.

Sincerely, \RA\ Brian Holian, Director Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-387 & 50-388

Enclosure:

As stated

cc w/encl: See next page

ML090440374 *Via e-mail OFFICE LA:DLR PM:DLR:RPB1 BC:DLR:RPB1 BC:DLR:RER1* BC:DLR:RER2* NAME SFigueroa EGettys DPelton JDozier RAuluck DATE 02/20/09 03/03/09 02/26/09 02/12/09 02/12/09 OFFICE PM:DKR:RPOB

  • BC:DE:EEEB* BC:DSS:SBPB* BC:DSS:SRXB* BC:DSS:SCVB* NAME JDaily GWilson DHarrison GCranston RDennig DATE 03/6/09 01/15/09 01/26/09 01/22/09 01/22/09 OFFICE BC:DCI:CVIB* BC:DE:EMCB* BC:DCI:CSGB* BC:DRA:AFPB* OGC (NLO) NAME MMitchell KManoly AHiser AKlein LSubin DATE 01/21/09 01/27/09 01/16/09 01/22/09 03/02/09 OFFICE D:DE* D:DSS D:DCI* D:DRA* D:DLR NAME PHiland WRuland MEvans MCunningham BHolian DATE 02/09/09 02/12/09 02/12/09 02/12/09 03/13/09 Letter to W. Spence from B. Holian, dated March 13, 2009 DISTRIBUTION

SUBJECT:

SAFETY EVALUATION REPORT WITH OPEN ITEMS RELATED TO THE LICENSE RENEWAL OF SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 HARD COPY: DLR RF E-MAIL: PUBLIC RidsNrrDlr RidsNrrDlrRlra RidsNrrDlrRlrb RidsNrrDlrRlrc RidsNrrDlrReba RidsNrrDlrRebb RidsNrrDciCvib RidsNrrDciCpnb RidsNrrDraAfpb RidsNrrDeEmcb RidsNrrDeEeeb RidsNrrDssSrxb RidsNrrDssSbpb RidsNrrDssScvb RidsOgcMailCenter


EGettys FJaxheimer Susquehanna Steam Electric Station, Units 1 and 2 cc: Cornelius J. Gannon Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467

Robert M. Paley General Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Michael H. Crowthers Manager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179

Ronald E. Smith General Manager - Site Preparedness and Services PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Michael H. Rose Manager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Joseph J. Scopelliti Community Relations Manager, Susquehanna PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467 Board of Supervisors Salem Township Bryan A. Snapp, Esq.

Associate General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Document Control Services PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Richard W. Osborne Allegheny Electric Cooperative, Inc. 212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266 Director, Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469

Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035

Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406

Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803

Dayne R. Brophy Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467