FW: MACCS2 input files for sensitivity cases in ER Page I of I Robert Palla - FW: MACCS2 input files for sensitivity cases in ER From:
"Mogolesko, Fred" <fmogole@entergy.com>
To:
"Alicia Williamson" <ARW1@nrc.gov>, "Robert Palla" <RLP3@nrc.gov>
Date:
05/04/2007 2:40 PM
Subject:
FW: MACCS2 input files for sensitivity cases in ER CC:
"Mogolesko, Fred" <fmiogole@entergy.com>, "Ford, Bryan" <BFord@entergy.com>, "Gaukler, Paul A."
<paul.gaukler@pillsburylaw.com>
See attached.
Fred From: Hong, Kou John Sent: Friday, May 04, 2007 2:21 PM To: Mogolesko, Fred
Subject:
MACCS2 input files for sensitivity cases Please find attached EARS1 P.INP and EARS2P.INP for Sensitivity Case 1 (2-hr delayed evacuation) and Sensitivity Case 2 (lower speed, 0.69 m/s, of evacuation), respectively.
<<ears1 p.txt>> <<ears2p.txt>>
file://C:\\temp\\GW} 00001.HTM 05/30/2007
c:\\temp\\GW}OOOQ1.TMP Pg Mail Envelope Properties (463B7E04.870 :23 :22640)
Subject:
Creation Date From:
Created By:
FW: MACCS2 input files for sensitivity cases in ER 05/04/2007 2:39:43 PM "Mogolesko, Fred" <fmogole@entergy.com>
fmogole(d)entergy.com Recipients nrc.gov TWGWPO04.HQGWDOO1 ARWI (Alicia Williamson) nrc.gov TWGWPO03.HQGWDO01 RLP3 (Robert Palla) pillsburylaw.com paul.gaukler CC (Paul A. Gaukler) entergy.com BFord CC (Bryan Ford)
Post Office TWGWPO04.HQGWDOO1 TWGWPO03.HQGWDOO1 Route nrc.gov nrc.gov pillsburylaw.com entergy.com Files MESSAGE TEXT.htm ears lp.txt ears2p.txt Mime.822 Options Expiration Date:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
Security:
Size 402 2433 13187 13187 42322 Date & Time 05/04/2007 2:39:43 PM None Standard No None No Standard
- \\temp\\'GW}O01.Pg.TMP...
Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled
earslp.txt
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "EARLY" INPUT FILE MIEANAM1001
'EARLY.IN, PNPS INPUT FROM THE EVACUATION TIME ESTIMATES' DCF-FILE001 'DOSDATA.INP' (DCF file of MACCS 1.5.11.1)
ORGNAM ORGFLG MIORGDEF001
'A-SKIN'
.TRUE.
MIORGDEF002
'A-RED MARR'
.TRUE.
MIORGDEF003
'A-LUNGS'
.TRUE.
MIORGDEF004
'A-THYROIDH'
.TRUE.
MIORGDEF005
'A-STOMACH'
.TRUE.
MIORGDEF006
'A-LOWER LI'
.FALSE.
(does not contribute to early fatalities)
MIORGDEF007
'L-EDEWBODY'
.TRUE.
MIORGDEF008
'L-RED MARR'
.TRUE.
MIORGDEF009
'L-BONE SUR'
.TRUE.
MIORGDEF010
'L-BREAST'
.TRUE.
MIORGDEF011
'L-LUNGS'
.TRUE.
MIORGDEF012
'L-THYROID'
.TRUE.
MIORGDEF013
'L-LOWER LI'
.TRUE.
MIORGDEF014
'L-BLAD WAL'
.TRUE.
MIORGDEF015
'L-LIVER'
.FALSE.
MIORGDEF016
'L-THYROIDH'
.TRUE.
- FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN MIENDAT2001
.FALSE.
(SET THIS VALUE TO.TRUE.
TO SKIP CHRONC)
- DISPERSION MODEL OPTION CODE:
1 STRAIGHT LINE 2
WIND-SHIFT WITH ROTATION 3
WIND-SHIFT WITHOUT ROTATION MIIPLUME001 2
- NUMBER OF FINE MINUMFIN001 7
- LEVEL OF DEBUG MIIPRINT001 0
GRID SUBDIVISIONS USED BY THE MODEL (3,
5 OR 7 ALLOWED)
OUTPUT REQUIRED, NORMAL RUNS SHOULD SPECIFY ZERO
- LOGICAL FLAG SIGNIFYING THAT THE BREAKDOWN OF RISK BY WEATHER CATEGORY
- BIN ARE TO BE PRESENTED TO SHOW THEIR RELATIVE CONTRIBUTION TO THE MEAN RISBIN MIRISCAT001
.FALSE.
FLAG INDICATING IF WIND-ROSES FROM ATMOS ARE TO BE OVERRIDDEN MIOVRRID001
.FALSE.
(USE THE WIND ROSE CALCULATED FOR EACH WEATHER BIN)
- POPULATION DISTRIBUTION DATA BLOCK, LOADED BY INPOPU, STORED IN /POPDAT/
PDPOPFLGO01 FILE
- PDPOPFLGO01 UNIFORM
- PDIBEGIN001 1
(SPATIAL INTERVAL AT WHICH POPULATION BEGINS)
- PDPOPDEN001
- 50.
(POPULATION DENSITY (PEOPLE PER SQUARE KILOMETER))
- .SHIELDING AND EXPOSURE FACTORS, LOADED BY INDFAC, STORED IN /EADFAC/
Page 1
earslp.txt
- THREE VALUES OF EACH PROTECTION FACTOR ARE SUPPLIED,
- ONE FOR EACH TYPE OF ACTIVTY:
- ACTIVITY TYPE:
1 -
EVACUEES WHILE MOVING 2 -
NORMAL ACTIVITY IN SHELTERING AND EVACUATION ZONE 3 -
SHELTERED ACTIVITY
- CLOUD SHIELDING FACTOR SITE GG PB SEQ SUR ZION SHELTERING 0.7 0.5 0.65 0.6 0.5 EVACUEES NORMAL SHELTER SECSFACT001
- 1.
0.75 0.6 SURRY SHELTERING VALUE
- PROTECTION FACTOR FOR INHALATION SEPROTIN001
- 1.
0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
- BREATHING RATE (CUBIC METERS PER SECOND)
SEBRRATE001 2.66E-4 2.66E-4 2.66E-4
- SKIN PROTECTION FACTOR SESKPFAC001 1.0 0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
- GROUND SHIELDING FACTOR SITE GG PB SEQ SUR ZION SHELTERING 0.25 0.1 0.2 0.2 0.1 SEGSHFAC001 0.5 0.4 0.2
- VALUE FOR NORMAL ACTIVITY SELECTED BY NRC STAFF
- RESUSPENSION INHALATION MODEL CONCENTRATION COEFFICIENT (/METER)
RESCON = 1.E-4 IS APPROPRIATE FOR MECHANICAL RESUSPENSION BY VEHICLES.
RESHAF'= 2.11 DAYS CAUSES 1.E-4 TO DECAY IN ONE WEEK TO 1.E-5, THE VALUE OF RESCON USED IN THE FIRST TERM OF THE LONG-TERM RESUSPENSION EQUATION USED IN CHRONC.
SERESCON001 1.E-4 (RESUSPENSION IS TURNED ON)
- RESUSPENSION CONCENTRATION COEFFICIENT HALF-LIFE (SEC)
SERESHAF001 1.82E5 (2.11 DAYS)
- EVACUATION ZONE DATA BLOCK, LOADED BY EVNETW, STORED IN /NETWOR/,
/EOPTIO/
- SPECIFIC DESCRIPTION OF THE EMERGENCY RESPONSE SCENARIO BEING USED EZEANAM2001
'EVACUATION WITHIN 10 MILES, RELOCATION MODELS APPLY ELSEWHERE'
- THE TYPE OF WEIGHTING TO BE APPLIED TO THE EMERGENCY RESPONSE SCENARIOS
- YOU MUST SUPPLY A VALUE OF 'TIME' OR 'PEOPLE' EZWTNAME001
'PEOPLE' Page 2
earslp.txt
- WEIGHTING FRACTION APPLICABLE TO THIS SCENARIO EZWTFRAC001 1.00
- LAST RING IN THE MOVEMENT ZONE EZLASMOV001 12 (EVACUEES DISAPPEAR AFTER TRAVELING TO 20 MILES)
Flag defining the time at which evacuees "enter" the destination element
- TRAVELPOINT
'CENTERPOINT' (new option implemented at MACCS2 v. 1.11f)
TRAVELPOINT
'BOUNDARY' (functionality derived from MACCS circa 1984)
- RADIAL EVACUATION SPEED (M/S)
EZESPEED001 0.97 0.97 0.97 EZEVATYP001
'RADIAL' EZDURBEGO01 86400.0 EZDURMID001 0.0 EZREFPNT001
'ALARM' EZNUMEVA001 10 EZDLTSHL001 7200.
7200.
7200.
7200.
7200.
EZDLTSHL002 7200.
7200.
7200.
7200.
7200.
EZDLTEVA001
- 0.
- 0.
- 0.
- 0.
0.
EZDLTEVA002
- 0.
- 0.
- 0.
- 0.
0.
- SHELTER AND RELOCATION ZONE DATA BLOCK, LOADED BY INPEMR, STORED IN /INPSRZ/,
/RELOCA/
- DURATION OF THE EMERGENCY PHASE (SECONDS FROM PLUME ARRIVAL)
SRENDEMP001 604800.
(ONE WEEK)
- CRITICAL ORGAN FOR RELOCATION DECISIONS SRCRIORGO01
'L-EDEWBODY'
- HOT SPOT RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
SRTIMHOT001 43200.
(ONE-HALF DAY)
- NORMAL RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
SRTIMNRM001 86400.
(ONE DAY)
- HOT SPOT RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSHOT001 0.5 (50 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
- NORMAL RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSNRM001 0.25 (25 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
- EARLY FATALITY MODEL PARAMETERS, LOADED BY INEFAT, STORED IN /EFATAL/
- NUMBER OF EARLY FATALITY EFFECTS EFNUMEFA001 2
ORGNAM EFFACA EFFACB EFFTHR EFATAGRP001
'A-RED MARR' 3.8 5.0 1.5 EFATAGRPO02
'A-LUNGS' 10.0 7.0 5.0 Page 3
earslp.txt
- EARLY INJURY MODEL PARAMETERS, LOADED BY INEINJ, STORED IN /EINJUR/
- NUMBER OF EARLY INJURY EFFECTS EINUMEIN001 7
EINAME ORGNAM EISUSC EITHRE EIFACA EIFACB EINJUGRP001
'PRODROMAL VOMIT'
'A-STOMACH'
- 1.
.5
- 2.
3.
EINJUGRP002
'DIARRHEA'
'A-STOMACH'
- 1.
- 1.
- 3.
2.5 EINJUGRP003
'PNEUMONITIS'
'A-LUNGS'
- 1.
- 5.
- 10.
7.
EINJUGRP004
'SKIN ERYTHEMA'
'A-SKIN'
- 1.
- 3.
- 6.
5.
EINJUGRP005
'TRANSEPIDERMAL'
'A-SKIN'
- 1.
- 10.
- 20.
5.
EINJUGRP006
'THYROIDITIS'
'A-THYROIDH'
- 1.
- 40.
240.
2.
EINJUGRP007
'HYPOTHYROIDISM'
'A-THYROIDH'
- 1.
- 2.
- 60.
1.3
- ACUTE EXPOSURE CANCER PARAMETERS, LOADED BY INACAN STORED IN /ACANCR/.
- NUMBER OF ACUTE EXPOSURE CANCER EFFECTS LCNUMACA001 7
- THRESHOLD DOSE FOR APPLYING THE DOSE DEPENDENT REDUCTION FACTOR LCDDTHRE001 0.2 (LOWEST DOSE FOR WHICH DDREFA WILL BE APPLIED)
- DOSE THRESHOLD FOR LINEAR DOSE RESPONSE (SV)
LCACTHRE001 0.0 (LINEAR-QUADRATIC MODEL IS NOT BEING USED)
ACNAME ORGNAM ACSUSC DOSEFA DOSEFB CFRISK CIRISK DDREFA LCANCERS001 'LEUKEMIA'
'L-RED MARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 LCANCERS002
'BONE'
'L-BONE SUR' 1.0 1.0 0.0 9.OOE-4 0.0 2.0 LCANCERS003
'BREAST'
'L-BREAST' 1.0 1.0 0.0 5.40E-3 1.7E-2 1.0 LCANCERS004
'LUNG'
'L-LUNGS' 1.0 1.0 0.0 1.55E-2 0.0 2.0 LCANCERS005
'THYROID'
'L-THYROIDH' 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 LCANCERS006
'GI'
'L-LOWER LI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 LCANCERS007
'OTHER'
'L-EDEWBODY' 1.0 1.0 0.0 2.76E-2 0.0 2.0
- RESULT 1 OPTIONS BLOCK, LOADED BY INOUT1, STORED IN /INOUT1/
- TOTAL NUMBER OF A GIVEN EFFECT (LATENT
- CANCER, EARLY DEATH, EARLY INJURY)
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPElNUMBER 4
TYPElOUT001
'ERL FAT/TOTAL' 1
15 NOCCDF (0 TO 50 MILES)
TYPElOUT009
'CAN FAT/TOTAL' 1
15 NOCCDF TYPElOUT019
'CAN FAT/TOTAL' 1
11 NOCCDF (0 TO 10 MILES)
TYPEIOUT020
'ERL FAT/TOTAL' 1
11 (0 TO 10 MILES)
- RESULT 2 OPTIONS BLOCK, LOADED BY INOUT2, STORED IN /INOUT2/
- FURTHEST DISTANCE AT WHICH A GIVEN RISK OF EARLY DEATH IS EXCEEDED.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE2NUMBER 0
FATALITY RISK THRESHOLD
- TYPE2OUT001 0.
Page 4
earslp.tx-t
- RESULT 3 OPTIONS BLOCK, LOADED BY INOUT3, STORED IN /INOUT3/
- NUMBER OF PEOPLE WHOSE DOSE TO A GIVEN ORGAN EXCEEDS A GIVEN THRESHOLD.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE3NUMBER 0
ORGAN NAME DOSE'THRESHOLD (SV)
- TYPE3OUT001
'A-RED MARR' 1.5
- TYPE3OUT002
'A-LUNGS' 5.0
- TYPE3OUT003
'L-EDEWBODY' 0.05
- RESULT 4 OPTIONS BLOCK, LOADED BY INOUT4, STORED IN /INOUT4/
- 360 DEGREE AVERAGE RISK OF A GIVEN EFFECT AT A GIVEN DISTANCE.
- POSSIBLE TYPES OF EFFECTS ARE:
'ERL FAT/TOTAL'
'ERL INJ/INJURY NAME'
'CAN FAT/CANCER NAME'
'CAN FAT/TOTAL'
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE4NUMBER 3
RADIAL INDEX TYPE OF EFFECT TYPE40UT001 1
'ERL FAT/TOTAL' TYPE4OUT002 2
'ERL FAT/TOTAL' TYPE4OUT003 3
'ERL FAT/TOTAL'
- RESULT 5 OPTIONS BLOCK, LOADED BY' INOUT5, STORED IN /INOUT5/
- TOTAL POPULATION DOSE TO A GIVEN ORGAN BETWEEN TWO DISTANCES.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE5NUMBER 1
ORGAN IlDIS5 I2DIS5 TYPE5OUT001
'L-EDEWBODY' 1
15 NOCCDF (0-50 MILES)
- RESULT 6 OPTIONS BLOCK, LOADED BY INOUT6, STORED IN /INOUT6/
- CENTERLINE DOSE TO AN ORGAN VS DIST BY PATHWAY, PATHWAY NAMES ARE AS FOLLOWS:
PATHWAY NAME:
'CLD' CLOUDSHINE
'GRD' GROUNDSHINE
'INH ACU' "ACUTE DOSE EQUIVALENT" FROM DIRECT INHALATION OF THE CLOUD
'INH LIF' "LIFETIME DOSE COMMITMENT" FROM DIRECT INHALATION OF THE CLOUD
'RES ACU' "ACUTE DOSE EQUIVALENT" FROM RESUSPENSION INHALATION
'RES LIF' "LIFETIME DOSE COMMITMENT" FROM RESUSPENSION INHALATION
'TOT ACU' "ACUTE DOSE EQUIVALENT" FROM ALL PATHWAYS
'TOT LIF' "LIFETIME DOSE COMMITMENT" FROM ALL PATHWAYS
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE6NUMBER 0
Page 5
earslp.txt ORGNAM PATHNM IDIS6 12DIS6
- TYPE6OUT001
'A-RED MARR'
'TOT ACU' 1
19 (0-50 MILES)
- TYPE6OUT002
'A-LUNGS'
'TOT ACU' 1
19 (0-50 MILES)
- TYPE6OUT003
'L-EDEWBODY'
'TOT LIF' 1
26 (0-1000 MILES)
- RESULT 7 OPTIONS BLOCK, LOADED BY INOUT7, STORED IN /INOUT7/
- CENTERLINE RISK OF A GIVEN EFFECT VS DISTANCE
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE7NUMBER 0
NAME IIDIS7 12DIS7
- TYPE7OUT001
'ERL FAT/TOTAL' 1
19 (0-50 MILES)
- TYPE7OUT002
'CAN FAT/TOTAL' 1
26 (0-1000 MILES)
- RESULT 8 OPTIONS BLOCK, LOADED BY INOUT8, STORED IN /INOUT8/
- POPULATION WEIGHTED FATALITY RISK BETWEEN 2 DISTANCES
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE8NUMBER 2
NAME IIDIS8 12DIS8 TYPE8OUT001
'ERL FAT/TOTAL' 1
.3 NOCCDF TYPE8OUT002
'CAN FAT/TOTAL' 1
11 NOCCDF (0-10 MILES)
- RESULT A OPTIONS BLOCK, LOADED BY INOUTA, STORED IN /INOUTA/
- peak dose to a given organ NUMA TYPEANUMBER 0
ORGNAM IlDISA I2DISA
- TYPEAOUT001
'L-EDEWBODY' 1
15 Page 6
ears2p.txt
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "EARLY" INPUT FILE MIEANAM1001 DCF-FILE001 MIORGDEF001 MIORGDEF002 MIORGDEF003 MIORGDEF004 MIORGDEF005 MIORGDEF006 MIORGDEF007 MIORGDEFO08 MIORGDEF009 MIORGDEF010 MIORGDEF011 MIORGDEF012 MIORGDEF013 MIORGDEF014 MIORGDEF015 MIORGDEF016
'EARLY.IN, PNPS INPUT FROM THE EVACUATION TIME ESTIMATES'
'DOSDATA.INP' (DCF file of MACCS 1.5.11.1)
ORGNAM ORGFLG
'A-SKIN'
.TRUE.
'A-RED MARR'
.TRUE.
'A-LUNGS'
.TRUE.
'A-THYROIDH'.
TRUE.
'A-STOMACH'
.TRUE.
'A-LOWER LI'
.FALSE.
(does not contribute to early fatalities)
'L-EDEWBODY'
.TRUE.
'L-RED MARR'
.TRUE.
'L-BONE SUR'
.TRUE.
'L-BREAST'
.TRUE.
'L-LUNGS'
.TRUE.
'L-THYROID'
.TRUE.
'L-LOWER LI'
,TRUE.
'L-BLAD WAL'
,TRUE.
'L-LIVER'
.FALSE.
'L-THYROIDH'
,TRUE.
FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN MIENDAT2001
.FALSE.
(SET THIS VALUE TO.TRUE.
TO SKIP CHRONC)
- DISPERSION MODEL OPTION CODE:
1 STRAIGHT LINE 2
WIND-SHIFT WITH ROTATION 3
WIND-SHIFT WITHOUT ROTATION MIIPLUME001 2
- NUMBER OF FINE GRID SUBDIVISIONS USED BY THE MODEL MINUMFIN001 7
(3, 5 OR 7 ALLOWED)
- LEVEL OF DEBUG OUTPUT REQUIRED, NORMAL RUNS SHOULD SPECIFY ZERO MIIPRINT001 0
- LOGICAL FLAG SIGNIFYING THAT THE BREAKDOWN OF RISK BY WEATHER CATEGORY
- BIN ARE TO BE PRESENTED TO SHOW THEIR RELATIVE CONTRIBUTION TO THE MEAN RISBIN MIRISCAT001
.FALSE.
FLAG INDICATING IF WIND-ROSES FROM ATMOS ARE TO BE OVERRIDDEN MIOVRRID001
.FALSE.
(USE-THE WIND ROSE CALCULATED FOR EACH WEATHER BIN)
- POPULATION DISTRIBUTION DATA BLOCK, LOADED BY INPOPU, STORED IN /POPDAT/
PDPOPFLGO01 FILE
- PDPOPFLGO01 UNIFORM
- PDIBEGIN001 1
(SPATIAL INTERVAL AT WHICH POPULATION BEGINS)
- PDPOPDEN001
- 50.
(POPULATION DENSITY (PEOPLE PER SQUARE KILOMETER))
- SHIELDING AND EXPOSURE FACTORS, LOADED BY INDFAC, STORED IN /EADFAC/
Page 1
- c
- r SE ears2p.txt THREE VALUES OF EACH PROTECTION FACTOR ARE SUPPLIED, ONE FOR EACH TYPE OF ACTIVTY:
ACTIVITY TYPE:
1 -
EVACUEES WHILE MOVING 2 -
NORMAL ACTIVITY IN SHELTERING AND EVACUATION ZONE 3 -
SHELTERED ACTIVITY CLOUD SHIELDING FACTOR SITE GG PB SEQ SUR ZION SHELTERING 0.7 0.5 0.65 0.6 0.5 EVACUEES NORMAL SHELTER ECSFACT001
- 1.
0.75 0.6 SURRY SHELTERING
/ALUE
- PROTECTION FACTOR FOR INHALATION SEPROTINO01
- 1.
0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
- BREATHING RATE (CUBIC METERS PER SEC(
SEBRRATE001 2.66E-4 2.66E-4 2.66E-4
- SKIN PROTECTION FACTOR SESKPFACO01 1.0 0.41 0.33
)ND)
- VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
- GROUND SHIELDING FACTOR SITE GG PB SEQ SHELTERING 0.25 0.1 0.2 SUR ZION 0.2 0.1 SEGSHFAC001 0.5 0.4 0.2
- VALUE FOR NORMAL ACTIVITY SELECTED BY NRC STAFF
- RESUSPENSION INHALATION MODEL CONCENTRATION COEFFICIENT (/METER)
RESCON = 1.E-4 IS APPROPRIATE FOR MECHANICAL RESUSPENSION.BY VEHICLES.
RESHAF = 2.11 DAYS CAUSES 1.E-4 TO DECAY IN ONE WEEK TO 1.E-5, THE VALUE OF RESCON USED IN THE FIRST TERM OF THE LONG-TERM RESUSPENSION EQUATION USED IN CHRONC.
SERESCON001 1.E-4 (RESUSPENSION IS TURNED ON)
- RESUSPENSION CONCENTRATION COEFFICIENT HALF-LIFE (SEC)
SERESHAF001 1.82E5 (2.11 DAYS)
EVACUATION ZONE DATA BLOCK, LOADED BY EVNETW, STORED IN /NETWOR/,
/EOPTIO/
- SPECIFIC DESCRIPTION OF THE EMERGENCY RESPONSE SCENARIO BEING USED EZEANAM2001
'EVACUATION WITHIN 10 MILES, RELOCATION MODELS APPLY ELSEWHERE'
- THE TYPE OF WEIGHTING TO BE APPLIED TO THE EMERGENCY RESPONSE SCENARIOS
- YOU MUST SUPPLY A VALUE OF 'TIME' OR 'PEOPLE' EZWTNAME001
'PEOPLE' Page 2
ears2p.txt
- WEIGHTING FRACTION APPLICABLE TO THIS SCENARIO EZWTFRACO01 1.00
- LAST RING IN THE MOVEMENT ZONE EZLASMOVO01 12 (EVACUEES DISAPPEAR AFTER TRAVELING TO 20 MILES)
Flag defining the time at which evacuees "enter" the destination element
- TRAVELPOINT
'CENTERPOINT' (new option implemented at MACCS2 v. 1.11f)
TRAVELPOINT
'BOUNDARY' (functionality derived from MACCS circa 1984)
- RADIAL EVACUATION SPEED (M/S)
EZESPEED001 0.69 0.69 0.69 EZEVATYP001
'RADIAL' EZDURBEGO01 86400.0 EZDURMIDO01 0.0 EZREFPNTO01
'ALARM' EZNUMEVAO01 10 EZDLTSHLO01 2400.
2400.
2400.
2400.
2400.
EZDLTSHL002 2400.
2400.
2400.
2400.
2400.
EZDLTEVAO01
- 0.
- 0.
- 0.
- 0.
0.
EZDLTEVA002
- 0.
- 0.
- 0.
- 0.
0.
- SHELTER AND RELOCATION ZONE DATA BLOCK, LOADED BY INPEMR, STORED IN /INPSRZ/,
/RELOCA/
- DURATION OF THE EMERGENCY PHASE (SECONDS FROM PLUME ARRIVAL)
SRENDEMPO01 604800.
(ONE WEEK)
- CRITICAL ORGAN FOR RELOCATION DECISIONS SRCRIORGO01 'L-EDEWBODY'
- HOT SPOT RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
SRTIMHOTO01 43200.
(ONE-HALF DAY)
- NORMAL RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
SRTIMNRMO01 86400.
(ONE DAY)
- HOT SPOT RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSHOTO01 0.5 (50 REM DOSE TO WHOLE BODY IN I WEEK TRIGGERS RELOCATION)
- NORMAL RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSNRM001 0.25 (25 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
- EARLY FATALITY MODEL PARAMETERS, LOADED BY INEFAT, STORED IN /EFATAL/
- NUMBER OF EARLY FATALITY EFFECTS EFNUMEFA001 2
ORGNAM EFFACA EFFACB EFFTHR EFATAGRPO01
'A-RED MARR' 3.8 5.0 1.5 EFATAGRP002
'A-LUNGS' 10.0 7.0 5.0 Page 3
ears2p.txt EARLY INJURY MODEL PARAMETERS, LOADED BY INEINJ, STORED IN /EINJUR/
- NUMBER OF EARLY INJURY EFFECTS EINUMEINO01 7
EINAME ORGNAM EISUSC EITHRE EIFACA EIFACB EINJUGRP001
'PRODROMAL VOMIT'
'A-STOMACH'
- 1.
.5
- 2.
3.
EINJUGRP002
'DIARRHEA'
'A-STOMACH'
- 1.
- 1.
- 3.
2.5 EINJUGRP003
'PNEUMONITIS'
'A-LUNGS'
- 1.
- 5.
- 10.
7.
EINJUGRP004
'SKIN ERYTHEMA'
!A-SKIN'
- 1.
- 3.
- 6.
5.
EINJUGRP005
'TRANSEPIDERMAL'
'A-SKIN'
- 1.
- 10.
- 20.
5.
EINJUGRP006
'THYROIDITIS'
'A-THYROIDH'
- 1.
- 40.
240.
2.
EINJUGRP007
'HYPOTHYROIDISM'
'A-THYROIDH'
- 1.
- 2.
- 60.
1.3
- ACUTE EXPOSURE CANCER PARAMETERS, LOADED BY INACAN STORED IN /ACANCR/.
- NUMBER OF ACUTE EXPOSURE CANCER EFFECTS LCNUMACA001 7
- THRESHOLD DOSE FOR APPLYING THE DOSE DEPENDENT REDUCTION FACTOR LCDDTHRE001 0.2 (LOWEST DOSE FOR WHICH DDREFA WILL BE APPLIED)
- DOSE THRESHOLD FOR LINEAR DOSE RESPONSE (Sv)
LCACTHRE001 0.0 (LINEAR-QUADRATIC MODEL IS NOT BEING USED)
ACNAME ORGNAM ACSUSC DOSEFA DOSEFB CFRISK CIRISK DDREFA LCANCERS001 'LEUKEMIA'
'L-RED MARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 LCANCERS002
'BONE'
'L-BONE SUR' 1.0 1.0 0.0 9.OOE-4 0.0 2.0 LCANCERS003
'BREAST'
'L-BREAST' 1.0 1.0 0.0 5".40E-3 1.7E-2 1.0 LCANCERS004
'LUNG'
'L-LUNGS' 1.0 1.0 0.0 1.55E-2 0.0 2.0 LCANCERS005
'THYROID'
'L-THYROIDH' 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 LCANCERS006
'GI'
'L-LOWER LI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 LCANCERS007
'OTHER'
'L-EDEWBODY' 1.0 1.0 0.0 2.76E-2 0.0 2.0
- RESULT 1 OPTIONS BLOCK, LOADED BY INOUT1, STORED IN /INOUT1/
- TOTAL NUMBER OF A GIVEN EFFECT (LATENT
- CANCER, EARLY DEATH, EARLY INJURY)
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPElNUMBER 4
TYPElOUTO01
'ERL FAT/TOTAL' 1
15 NOCCDF (0 TO 50 MILES)
TYPElOUT009
'CAN FAT/TOTAL' 1
15 NOCCDF TYPElOUT019
'CAN FAT/TOTAL' 1
11 NOCCDF (0 TO 10 MILES)
TYPEIOUT020
'ERL FAT/TOTAL' 1
11 (0 TO 10 MILES)
- RESULT 2 OPTIONS BLOCK, LOADED BY INOUT2, STORED IN /INOUT2/
- FURTHEST DISTANCE AT WHICH A GIVEN RISK OF EARLY DEATH IS EXCEEDED.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE2NUMBER 0
FATALITY RISK THRESHOLD
- TYPE2OUT001 0.
Page 4
ears2p.txt
- RESULT 3 OPTIONS BLOCK, LOADED BY INOUT3, STORED IN /INOUT3/
- NUMBER OF PEOPLE WHOSE DOSE TO A GIVEN ORGAN EXCEEDS A GIVEN THRESHOLD.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE3NUMBER 0
ORGAN NAME DOSE THRESHOLD (Sv)
- TYPE3OUT001
'A-RED MARR' 1.5
- TYPE3OUT002
'A-LUNGS' 5.0
- TYPE3OUT003
'L-EDEWBODY' 0.05
- RESULT 4 OPTIONS BLOCK, LOADED BY INOUT4, STORED IN /INOUT4/
- 360 DEGREE AVERAGE RISK OF A GIVEN EFFECT AT A GIVEN DISTANCE.
- POSSIBLE TYPES OF EFFECTS ARE:
'ERL FAT/TOTAL'
'ERL INJ/INJURY NAME'
'CAN FAT/CANCER NAME'
'CAN FAT/TOTAL'
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE4NUMBER 3
RADIAL INDEX TYPE OF EFFECT TYPE40UT001 1
'ERL FAT/TOTAL' TYPE4OUT002 2
'ERL FAT/TOTAL' TYPE4OUT003 3
'ERL FAT/TOTAL'
- RESULT 5 OPTIONS BLOCK, LOADED BY INOUTS, STORED IN /INOUT5/
- TOTAL POPULATION DOSE TO A GIVEN ORGAN BETWEEN TWO DISTANCES.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPESNUMBER 1
ORGAN IlDIS5 12DIS5 TYPE5OUT001
'L-EDEWBODY' 1
15 NOCCDF (0-50 MILES)
- RESULT 6 OPTIONS BLOCK, LOADED BY INOUT6, STORED IN /INOUT6/
- CENTERLINE DOSE TO AN ORGAN VS DIST BY PATHWAY, PATHWAY NAMES ARE AS FOLLOWS:
PATHWAY NAME:
'CLD' CLOUDSHINE
'GRD' GROUNDSHINE
'INH ACU' "ACUTE DOSE EQUIVALENT" FROM DIRECT INHALATION OF THE CLOUD
'INH LIF' "LIFETIME DOSE COMMITMENT" FROM DIRECT INHALATION OF THE CLOUD
'RES ACU' "ACUTE DOSE EQUIVALENT" FROM RESUSPENSION INHALATION
'RES LIF' "LIFETIME DOSE COMMITMENT" FROM RESUSPENSION INHALATION
'TOT ACU' "ACUTE DOSE EQUIVALENT" FROM ALL PATHWAYS
'TOT LIF' "LIFETIME DOSE COMMITMENT" FROM ALL PATHWAYS
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE6NUMBER 0
Page 5
ears2p.txt ORGNAM PATHNM IIDIS6 I2DIS6
- TYPE6OUT001
'A-RED MARR'
'TOT ACU' 1
19 (0-50 MILES)
- TYPE6OUT002
'A-LUNGS'
'TOT ACU' 1
19 (0-50 MILES)
- TYPE6OUT003
'L-EDEWBODY'
'TOT LIF' 1
26 (0-1000 MILES)
- RESULT 7 OPTIONS BLOCK, LOADED BY INOUT7, STORED IN /INOUT7/
- CENTERLINE RISK OF A GIVEN EFFECT VS DISTANCE
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE7NUMBER 0
NAME IIDIS7 12DIS7
- TYPE7OUT001
'ERL FAT/TOTAL' 1
19 (0-50 MILES)
- TYPE7OUT002
'CAN FAT/TOTAL' 1
26 (0-1000 MILES)
- RESULT 8 OPTIONS BLOCK, LOADED BY INOUT8, STORED IN /INOUT8/
- POPULATION WEIGHTED FATALITY RISK BETWEEN 2 DISTANCES
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE8NUMBER 2
NAME IIDIS8 12DIS8 TYPE8OUT001 'ERL FAT/TOTAL' 1
3 NOCCDF TYPE8OUT002
'CAN FAT/TOTAL' 1
11 NOCCDF (0-10 MILES)
- RESULT A OPTIONS BLOCK, LOADED BY INOUTA, STORED IN /INOUTA/
- peak dose to a given organ NUMA TYPEANUMBER 0
ORGNAM IlDISA I2DISA
- TYPEAOUT001
'L-EDEWBODY' 1
15 Page 6