I Alicia Williamson - FW: MACCS2 input files for sensitivity cases in ER I
Page I1I I Alicia..Will.amson....FW:. MAC. CS..inpu. f....l....s fo sen......si iv.i..ty cases in ER Page 1 From:
"Mogolesko, Fred" <fmogole@entergy.com>
To:
"Alicia Williamson" <ARWl@nrc.gov>, "Robert Palla" <RLP3@nrc.gov>
Date:
05/04/2007 2:40:29 PM
Subject:
FW: MACCS2 input files for sensitivity cases in ER See attached.
Fred From: Hong, Kou John Sent: Friday, May 04, 2007 2:21 PM To: Mogolesko, Fred
Subject:
MACCS2 input files for sensitivity cases Please find attached EARSIP.INP and EARS2P.INP for Sensitivity Case 1 (2-hr delayed evacuation) and Sensitivity Case 2 (lower speed, 0.69 m/s, of evacuation), respectively.
<<earslp.txt>> <<ears2p.txt>>
CC:
"Mogolesko, Fred" <fmogole@entergy.com>, "Ford, Bryan" <BFord@entergy.com>,
"Gaukler, Paul A." <paul.gaukler@pillsburylaw.com>
l I cAtemp\\ VYJ00001.TMP Page 1:1 I c:\\te-m. p....W }....O O.....T M
P a g e 1 I....r
- ¸*d**d*h;;
..... H %k...................
Mail Envelope Properties (463B7E04.870 :23 :22640)
Subject:
Creation Date From:
Created By:
FW: MACCS2 input files for sensitivity cases in ER 05/04/2007 2:39:43 PM "Mogolesko, Fred" <fmogole(*entergy.com>
fmiogolea~entergM.com Recipients nrc.gov TWGWPO04.HQGWDO01 ARWI (Alicia Williamson) nrc.gov TWGWPO03.HQGWDO01 RLP3 (Robert Palla>
pillsburylaw.com paul.gaukler CC (Paul A. Gaukler) entergy.com BFord CC (Bryan Ford)
Post Office TWGWPOO4.HQGWDOO1 TWGWPO03.HQGWDO0I Route nrc.gov nrc.gov pillsburylaw.com entergy.corn Files MESSAGE TEXT.htm earslp.txt ears2p.txt Mime.822 Options Expiration Date:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
Security:
Size 402 2433 13187 13187 42322 Date & Time 05/04/2007 2:39:43 PM None Standard No None No Standard
I Alicia Williamson - ears1 p.txt SPagel 1
- GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "EARLY" INPUT FILE MIEANAM1001 'EARLY.IN, PNPS INPUT FROM THE EVACUATION TIME ESTIMATES' DCFFILE001 'DOSDATA.INP' (DCF file of MACCS 1.5.11.1)
ORGNAM ORGFLG MIORGDEF001 'A-SKIN'
.TRUE.
MIORGDEF002 'A-RED MARR'
.TRUE.
MIORGDEF003 'A-LUNGS'
.TRUE.
MIORGDEF004 'A-THYROIDH'
.TRUE.
MIORGDEF005 'A-STOMACH'
.TRUE.
MIORGDEF006 'A-LOWER LI'
.FALSE. (does not contribute to early fatalities)
MIORGDEF007 'L-EDEWBODY'
.TRUE.
MIORGDEF008 'L-RED MARR'
.TRUE.
MIORGDEF009 'L-BONE SUR'
.TRUE.
MIORGDEF010 'L-BREAST'
.TRUE.
MIORGDEF01 1 'L-LUNGS'
.TRUE.
MIORGDEF012 'L-THYROID'
.TRUE.
MIORGDEF013 'L-LOWER LI'
.TRUE.
MIORGDEF014 'L-BLAD WAL'
.TRUE.
MIORGDEF015 'L-LIVER'
.FALSE.
MIORGDEF016 t_-THYROIDH'
.TRUE.
- FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN MIENDAT2001.FALSE.
(SET THIS VALUE TO.TRUE. TO SKIP CHRONC)
- DISPERSION MODEL OPTION CODE: I
- STRAIGHT LINE 2
- WIND-SHIFT WITH ROTATION 3
- WIND-SHIFT WITHOUT ROTATION MIIPLUME001 2 0
- NUMBER OF FINE GRID SUBDIVISIONS USED BY THE MODEL MINUMFIN001 7 (3,5 OR 7 ALLOWED)
- LEVEL OF DEBUG OUTPUT REQUIRED, NORMAL RUNS SHOULD SPECIFY ZERO MIIPRINTOOI 0
- LOGICAL FLAG SIGNIFYING THAT THE BREAKDOWN OF RISK BY WEATHER CATEGORY
- BIN ARE TO BE PRESENTED TO SHOW THEIR RELATIVE CONTRIBUTION TO THE MEAN RISBIN MIRISCAT001
.FALSE.
- FLAG INDICATING IF WIND-ROSES FROM ATMOS ARE TO BE OVERRIDDEN MIOVRRID001.FALSE. (USE THE WIND ROSE CALCULATED FOR EACH WEATHER BIN)
- POPULATION DISTRIBUTION DATA BLOCK, LOADED BY INPOPU, STORED IN /POPDAT/
F PDPOPFLG001 FILE
Ahicia Williamson - earslp.!tt Page 2
'PDPOPFLGO01 UNIFORM
- PDIBEGIN001 1 (SPATIAL INTERVAL AT WHICH POPULATION BEGINS)
- PDPOPDEN001 50. (POPULATION DENSITY (PEOPLE PER SQUARE KILOMETER))
- SHIELDING AND EXPOSURE FACTORS, LOADED BY INDFAC, STORED IN /EADFAC/
'THREE VALUES OF EACH PROTECTION FACTOR ARE SUPPLIED,
'ONE FOR EACH TYPE OF ACTIVTY:
"ACTIVITY TYPE:
I - EVACUEES WHILE MOVING S2
- NORMAL ACTIVITY IN SHELTERING AND EVACUATION ZONE 3 - SHELTERED ACTIVITY
- CLOUD SHIELDING FACTOR SITE GG PB SEQ SUR ZION SHELTERING 0.7 0.5 0.65 0.6 0.5 EVACUEES NORMAL SHELTER SECSFACT001
- 1.
0.75 0.6
- SURRY SHELTERING VALUE
- PROTECTION FACTOR FOR INHALATION SEPROTIN001
- 1.
0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
'BREATHING RATE (CUBIC METERS PER SECOND)
SEBRRATE001 2.66E-4 2.66E-4 2.66E-4
'SKIN PROTECTION FACTOR SESKPFAC001 1.0 0.41 0.33 ' VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
'GROUND SHIELDING FACTOR SITE GG PB SEQ SUR ZION SHELTERING 0.25 0.1 0.2 0.2 0.1 SEGSHFAC001 0.5 0.4 0.2 ' VALUE FOR NORMAL ACTIVITY SELECTED BY NRC STAFF
'RESUSPENSION INHALATION MODEL CONCENTRATION COEFFICIENT (/METER)
' RESCON = 1.E-4 IS APPROPRIATE FOR MECHANICAL RESUSPENSION BY VEHICLES.
RESHAF = 2.11 DAYS CAUSES I.E-4 TO DECAY IN ONE WEEK TO I.E-5, THE VALUE OF RESCON USED IN THE FIRST TERM OF THE LONG-TERM RESUSPENSION EQUATION USED IN CHRONC.
SERESCON001 1.E-4 (RESUSPENSION IS TURNED ON)
' RESUSPENSION CONCENTRATION COEFFICIENT HALF-LIFE (SEC)
Alicia Williamson - earslp.txt Paae 3 I I
I Alicia Williamson - earsip.b(t Page 3 1 SERESHAF001 1.82E5 (2.11 DAYS)
- EVACUATION ZONE DATA BLOCK, LOADED BY EVNETW, STORED IN /NETWOR/, /EOPTIOI 0
'SPECIFIC DESCRIPTION OF THE EMERGENCY RESPONSE SCENARIO BEING USED EZEANAM2001 'EVACUATION WITHIN 10 MILES, RELOCATION MODELS APPLY ELSEWHERE'
- THE TYPE OF WEIGHTING TO BE APPLIED TO THE EMERGENCY RESPONSE SCENARIOS
" YOU MUST SUPPLY A VALUE OF 7IME' OR 'PEOPLE' EZWTNAME001 'PEOPLE'
'WEIGHTING FRACTION APPLICABLE TO THIS SCENARIO EZWTFRAC001 1.00
'LAST RING IN THE MOVEMENT ZONE EZLASMOV001 12 (EVACUEES DISAPPEAR AFTER TRAVELING TO 20 MILES) 0 Flag defining the time at which evacuees "enter" the destination element
'TRAVELPOINT
'CENTERPOINT' (new option implemented at MACCS2 v. 1.11f)
TRAVELPOINT 'BOUNDARY' (functionality derived from MACCS circa 1984)
'RADIAL EVACUATION SPEED (M/S)
EZESPEED001 0.97 0.97 0.97 EZEVATYP001
'RADIAL' EZDURBEG001 86400.0 EZDURMID001 0.0 EZREFPNT001
'ALARM' EZNUMEVA001 10 EZDLTSHL001 7200. 7200. 7200. 7200. 7200.
EZDLTSHLOO2 7200. 7200. 7200. 7200. 7200.
EZDLTEVA001
- 0.
- 0.
- 0.
- 0.
0.
EZDLTEVA002
- 0.
- 0.
- 0.
- 0.
0.
'SHELTER AND RELOCATION ZONE DATA BLOCK, LOADED BY INPEMR, STORED IN IINPSRZ/, /RELOCA/
'DURATION OF THE EMERGENCY PHASE (SECONDS FROM PLUME ARRIVAL)
SRENDEMP001 604800. (ONE WEEK)
- CRITICAL ORGAN FOR RELOCATION DECISIONS SRCRIORG001 'L-EDEWBODY'
'HOT SPOT RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
SRTIMHOT001 43200.
(ONE-HALF DAY)
'NORMAL RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
I....
I Alicia Williamson - earslp.txt PnnA 4 I Pan 41I SRTIMNRM001 86400.
(ONE DAY)
- HOT SPOT RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSHOT001 0.5 (50 REM DOSE TO WHOLE BODY IN I WEEK TRIGGERS RELOCATION)
- NORMAL RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSNRM001 0.25 (25 REM DOSE TO WHOLE BODY IN I WEEK TRIGGERS RELOCATION)
- EARLY FATALITY MODEL PARAMETERS, LOADED BY INEFAT, STORED IN /EFATALI
- NUMBER OF EARLY FATALITY EFFECTS EFNUMEFA001 2 ORGNAM EFFACA EFFACB EFFTHR EFATAGRP001 'A-RED MARR' 3.8 5.0 1.5 EFATAGRP002 'A-LUNGS' 10.0 7.0 5.0
- EARLY INJURY MODEL PARAMETERS, LOADED BY INEINJ, STORED IN /EINJURI
- NUMBER OF EARLY INJURY EFFECTS EINUMEIN001 7 EINAME ORGNAM EISUSC EITHRE EIFACA EIFACB EINJUGRP001 'PRODROMAL VOMIT' 'A-STOMACH' 1.
.5
- 2.
3.
EINJUGRP002 'DIARRHEA'
'A-STOMACH' 1.
- 1.
- 3.
2.5 EINJUGRP003 'PNEUMONITIS'
'A-LUNGS'
- 1.
- 5.
- 10.
7.
EINJUGRP004 'SKIN ERYTHEMA' 'A-SKIN'
- 1.
- 3.
- 6.
5.
EINJUGRPOO5 7RANSEPIDERMAL' 'A-SKIN'
- 1.
- 10. 20.
5.
EINJUGRP006 7HYROIDITIS'
'A-THYROIDH' 1. 40. 240.
2.
EINJUGRP007 'HYPOTHYROIDISM' 'A-THYROIDH' 1.
- 2.
- 60.
1.3 ACUTE EXPOSURE CANCER PARAMETERS, LOADED BY INACAN STORED IN /ACANCRI.
- NUMBER OF ACUTE EXPOSURE CANCER EFFECTS LCNUMACA001 7
"THRESHOLD DOSE FOR APPLYING THE DOSE DEPENDENT REDUCTION FACTOR LCDDTHRE001 0.2 (LOWEST DOSE FOR WHICH DDREFA WILL BE APPLIED)
- DOSE THRESHOLD FOR LINEAR DOSE RESPONSE (Sv)
LCACTHRE001 0.0 (LINEAR-QUADRATIC MODEL IS NOT BEING USED)
ACNAME ORGNAM ACSUSC DOSEFA DOSEFB CFRISK CIRISK DDREFA LCANCERS0OI 'LEUKEMIA"'L-RED MARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 LCANCERS002'BONE'
'L-BONE SUR' 1.0 1.0 0.0 9.OOE-4 0.0 2.0
I 1 Alicia Williamson - earslp.txt Page 5 jt I Alicia Williamson - earslp.txt Page 51 LCANCERS003'BREAST' 'L-BREAST' 1.0 1.0 0.0 5.40E-3 1.7E-2 1.0 LCANCERS004 'LUNG'
'L-LUNGS' 1.0 1.0 0.0 1.55E-2 0.0 2.0 LCANCERS005 'THYROID' 'L-THYROIDH' 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 LCANCERS006'GI'
'L-LOWERLI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 LCANCERS007'OTHER'
'L-EDEWBODY' 1.0 1.0 0.0 2.76E-2 0.0 2.0
- RESULT 1 OPTIONS BLOCK, LOADED BY INOUTI, STORED IN /INOUTI/
- TOTAL NUMBER OF A GIVEN EFFECT (LATENT CANCER, EARLY DEATH, EARLY INJURY)
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE1NUMBER 4
TYPE1OUT001
'ERL FAT/TOTAL' 1 15 NOCCDF (0 TO 50 MILES)
TYPElOUT009
'CAN FAT/TOTAL' 1 15 NOCCDF TYPElOUT019
'CAN FAT/TOTAL' 1 11 NOCCDF (0 TO 10 MILES)
TYPElOUT020
'ERL FAT/TOTAL' 1 11 (0 TO 10 MILES)
- RESULT 2 OPTIONS BLOCK, LOADED BY INOUT2, STORED IN /INOUT2/
- FURTHEST DISTANCE AT WHICH A GIVEN RISK OF EARLY DEATH IS EXCEEDED.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE2NUMBER 0 e
FATALITY RISK THRESHOLD
- TYPE2OUT001 0.
" RESULT 3 OPTIONS BLOCK, LOADED BY INOUT3, STORED IN INOUT3/
" NUMBER OF PEOPLE WHOSE DOSE TO A GIVEN ORGAN EXCEEDS A GIVEN THRESHOLD.
'NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE3NUMBER 0 ORGAN NAME DOSE THRESHOLD (Sv)
'TYPE3OUT001
'A-RED MARR' 1.5
- TYPE3OUT002
'A-LUNGS' 5.0
- TYPE3OUT003
'L-EDEWBODY' 0.05
- RESULT 4 OPTIONS BLOCK, LOADED BY INOUT4, STORED IN INOUT4/
- 360 DEGREE AVERAGE RISK OF A GIVEN EFFECT AT A GIVEN DISTANCE.
'POSSIBLE TYPES OF EFFECTS ARE:
'ERL FAT/TOTAL' O 'ERL INJ/INJURY NAME' O 'CAN FAT/CANCER NAME'
- 'CAN FAT/TOTAL'
'NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE4NUMBER 3
L I Ailcla Williamson - earsl p.bd Page 61 I Alicia Williamson-earsip.txt Page 61 RADIAL INDEX TYPE OF EFFECT T
TYPE4OUT002 2
'ERL FAT/TOTAL' TYPE4OUT002 2
'ERL FAT/TOTAL' TYPE4OUT003 3
'ERL FAT/TOTAL'
- RESULT 5 OPTIONS BLOCK, LOADED BY INOUT5, STORED IN INOUT5/
- TOTAL POPULATION DOSE TO A GIVEN ORGAN BETWEEN TWO DISTANCES.
'NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE5NUMBER 1
ORGAN 11DIS5 12DIS5 TYPE5OUT001 'L-EDEWBODY' 1
15 NOCCDF (0-50 MILES)
- RESULT 6 OPTIONS BLOCK, LOADED BY INOUT6, STORED IN /INOUT6/
'CENTERLINE DOSE TO AN ORGAN VS DIST BY PATHWAY, PATHWAY NAMES ARE AS FOLLOWS:
' PATHWAY NAME:
" 'CLD'
- CLOUDSHINE
- 'GRD'
-GROUNDSHINE
" 'INH ACU' - "ACUTE DOSE EQUIVALENT" FROM DIRECT INHALATION OF THE CLOUD
" 'INH LIF' - "LIFETIME DOSE COMMITMENT" FROM DIRECT INHALATION OF THE CLOUD
" 'RES ACU' - "ACUTE DOSE EQUIVALENT" FROM RESUSPENSION INHALATION
" 'RES LIF' - "LIFETIME DOSE COMMITMENT" FROM RESUSPENSION INHALATION S'TOT ACU' - "ACUTE DOSE EQUIVALENT" FROM ALL PATHWAYS
" TOT LIF' - "LIFETIME DOSE COMMITMENT" FROM ALL PATHWAYS
'NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE6NUMBER 0
ORGNAM PATHNM I1DIS6 12DIS6
- 'TYPE6OUT001 'A-RED MARR'
'TOT ACU' 1
19 (0-50 MILES)
- TYPE6OUT002 'A-LUNGS'
'TOT ACU' 1
19 (0-50 MILES)
- TYPE6OUT003 'L-EDEWBODY' TOT LIF' 1
26 (0-1000 MILES)
'RESULT 7 OPTIONS BLOCK, LOADED BY INOUT7, STORED IN INOUT7/
'CENTERLINE RISK OF A GIVEN EFFECT VS DISTANCE
'NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE7NUMBER 0 NAME 11DIS7 12DIS7
- TYPE7OUT001
'ERL FAT/TOTAL' 1
19 (0-50 MILES)
- 'TYPE7OUT002
'CAN FAT/TOTAL' 1
26 (0-1000 MILES)
I Alicia Williamson - earsl p.txt Page 7 ý r l c a W l i m o P a g e 7...
.1*
,t,,
- f
,t
- * *~r.....
.* = 1 lit tilltt " *..
- RESULT 8 OPTIONS BLOCK, LOADED BY INOUT8, STORED IN INOUT8/
- POPULATION WEIGHTED FATALITY RISK BETWEEN 2 DISTANCES
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE8NUMBER 2 NAME I1DIS8 12DIS8 TYPE8OUTOO 'ERL FAT/TOTAL' 1 3
NOCCDF TYPE8OUT002 'CAN FAT/TOTAL' 1 11 NOCCDF (0-10 MILES)
- RESULT A OPTIONS BLOCK, LOADED BY INOUTA, STORED IN INOUTA/
t
- peak dose to a given organ NUMA TYPEANUMBER 0 ORGNAM IIDISA 12DISA
- TYPEAOUT001 'L-EDEWBODY' 1 15
I....
I AliCia Williamson - ears2p.txt Paoe I I Pawl
'GENERAL DESCRIPTIVE TITLE DESCRIBING THIS "EARLY" INPUT FILE MIEANAM1001 'EARLY.IN, PNPS INPUT FROM THE EVACUATION TIME ESTIMATES' DCF_FILE001 'DOSDATA.INP' (DCF file of MACCS 1.5.11.1)
ORGNAM ORGFLG MIORGDEF001 'A-SKIN'
.TRUE.
MIORGDEF002 'A-RED MARR'
.TRUE.
MIORGDEF003 'A-LUNGS'
.TRUE.
MIORGDEF004 'A-THYROIDH'
.TRUE.
MIORGDEF005 'A-STOMACH'
.TRUE.
MIORGDEF006 'A-LOWER L'
.FALSE. (does not contribute to early fatalities)
MIORGDEF007 1.-EDEWBODY'
.TRUE.
MIORGDEF008 1.-RED MARR'
.TRUE.
MIORGDEF009 'L-BONE SUR'
.TRUE.
MIORGDEF010 'L-BREAST'
,TRUE.
MIORGDEF01 I 'L-LUNGS'
.TRUE.
MIORGDEF012 'L-THYROID'
.TRUE.
MIORGDEF013 'L-LOWER LI'
.TRUE.
MIORGDEF014 'L-BLAD WAL'
.TRUE.
MIORGDEF015 'L-LIVER'
.FALSE.
MIORGDEF016 'L-THYROIDH'
.TRUE.
"FLAG TO INDICATE THAT THIS IS THE LAST PROGRAM IN THE SERIES TO BE RUN MIENDAT2001.FALSE.
(SET THIS VALUE TO.TRUE. TO SKIP CHRONC)
'DISPERSION MODEL OPTION CODE: I
- STRAIGHT LINE 2
- WIND-SHIFT WITH ROTATION 3
- WIND-SHIFT WITHOUT ROTATION MIIPLUME001 2
- NUMBER OF FINE GRID SUBDIVISIONS USED BY THE MODEL MINUMFIN001 7 (3, 5 OR 7 ALLOWED)
'LEVEL OF DEBUG OUTPUT REQUIRED, NORMAL RUNS SHOULD SPECIFY ZERO MIIPRINT001 0
'LOGICAL FLAG SIGNIFYING THAT THE BREAKDOWN OF RISK BY WEATHER CATEGORY
'BIN ARE TO BE PRESENTED TO SHOW THEIR RELATIVE CONTRIBUTION TO THE MEAN RISBIN MIRISCAT001
.FALSE.
'FLAG INDICATING IF WIND-ROSES FROM ATMOS ARE TO BE OVERRIDDEN MIOVRRID001.FALSE. (USE THE WIND ROSE CALCULATED FOR EACH WEATHER BIN)
- POPULATION DISTRIBUTION DATA BLOCK, LOADED BY INPOPU, STORED IN /POPDAT/
PDPOPFLG001 FILE
I..
II Alicia Wlliamson - ears2p.txt Paao 2 I I
I-I!
'PDPOPFLGO01 UNIFORM
- PDIBEGIN001 1 (SPATIAL INTERVAL AT WHICH POPULATION BEGINS)
'PDPOPDEN001
- 50. (POPULATION DENSITY (PEOPLE PER SQUARE KILOMETER))
- SHIELDING AND EXPOSURE FACTORS, LOADED BY INDFAC, STORED IN /EADFAC/
- THREE VALUES OF EACH PROTECTION FACTOR ARE SUPPLIED,
- ONE FOR EACH TYPE OF ACTIVTY:
'ACTIVITY TYPE:
1 - EVACUEES WHILE MOVING 2 - NORMAL ACTIVITY IN SHELTERING AND EVACUATION ZONE 3-SHELTERED ACTIVITY
- CLOUD SHIELDING FACTOR SITE GG PB SEQ SUR ZION SHELTERING 0.7 0.5 0.65 0.6 0.5 EVACUEES NORMAL SHELTER SECSFACT001
- 1.
0.75 0.6
- SURRY SHELTERING VALUE
'PROTECTION FACTOR FOR INHALATION SEPROTIN001
- 1.
0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
'BREATHING RATE (CUBIC METERS PER SECOND)
SEBRRATE001 2.66E-4 2.66E-4 2.66E-4
'SKIN PROTECTION FACTOR 0
SESKPFAC001 1.0 0.41 0.33
- VALUES FOR NORMAL ACTIVITY AND SHELTERING SELECTED BY NRC STAFF
'GROUND SHIELDING FACTOR SITE GG PB SEQ SUR ZION SHELTERING 0.250.1 0.2 0.2 0.1 SEGSHFAC001 0.5 0.4 0.2
- VALUE FOR NORMAL ACTIVITY SELECTED BY NRC STAFF
'RESUSPENSION INHALATION MODEL CONCENTRATION COEFFICIENT (/METER)
' RESCON = 1.E-4 IS APPROPRIATE FOR MECHANICAL RESUSPENSION BY VEHICLES.
RESHAF = 2.11 DAYS CAUSES 1.E-4 TO DECAY IN ONE WEEK TO I.E-5, THE VALUE OF RESCON USED IN THE FIRST TERM OF THE LONG-TERM RESUSPENSION EQUATION
- USED IN CHRONC.
SERESCON001 1.E-4 (RESUSPENSION IS TURNED ON)
' RESUSPENSION CONCENTRATION COEFFICIENT HALF-LIFE (SEC)
Alicia Williamson - ears2p.txt Pagqe 3.1 I Alicia Williamson - ears2p.txt Pai~e 3 SERESHAF001 1.82E5 (2.11 DAYS)
'EVACUATION ZONE DATA BLOCK, LOADED BY EVNETW, STORED IN /NETWOR/, IEOPTIOI
'SPECIFIC DESCRIPTION OF THE EMERGENCY RESPONSE SCENARIO BEING USED EZEANAM2001 'EVACUATION WITHIN 10 MILES, RELOCATION MODELS APPLY ELSEWHERE' "THE TYPE OF WEIGHTING TO BE APPLIED TO THE EMERGENCY RESPONSE SCENARIOS
'YOU MUST SUPPLY A VALUE OF TIME' OR 'PEOPLE' EZWTNAME001 'PEOPLE'
'WEIGHTING FRACTION APPLICABLE TO THIS SCENARIO EZWTFRAC001 1.00
'LAST RING IN THE MOVEMENT ZONE EZLASMOV001 12 (EVACUEES DISAPPEAR AFTER TRAVELING TO 20 MILES)
- Flag defining the time at which evacuees "enter" the destination element
- 'TRAVELPOINT 'CENTERPOINT' (new option implemented at MACCS2 v. 1.110 TRAVELPOINT 'BOUNDARY' (functionality derived from MACCS circa 1984)
'RADIAL EVACUATION SPEED (M/S)
EZESPEED001 0.69 0.69 0.69 EZEVATYP001
'RADIAL' EZDURBEGO01 86400.0 EZDURMID001 0.0 EZREFPNT001
'ALARM' EZNUMEVA001 10 EZDLTSHL001 2400. 2400. 2400. 2400. 2400.
EZDLTSHLOO2 2400. 2400. 2400. 2400. 2400.
EZDLTEVA001
- 0.
- 0.
- 0.
- 0.
0.
EZDLTEVA002
- 0.
- 0.
- 0.
- 0.
0.
'SHELTER AND RELOCATION ZONE DATA BLOCK, LOADED BY INPEMR, STORED IN /INPSRZ/, /RELOCAI
- DURATION OF THE EMERGENCY PHASE (SECONDS FROM PLUME ARRIVAL)
SRENDEMP001 604800. (ONE WEEK)
'CRITICAL ORGAN FOR RELOCATION DECISIONS SRCRIORG001 'L-EDEWBODY'
'HOT SPOT RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
SRTIMHOT001 43200.
(ONE-HALF DAY)
' NORMAL RELOCATION TIME (SECONDS FROM PLUME ARRIVAL)
I h~!...!.. tAIfl*+/-
IAicia Wvilliamson - ears~p.xxi Paae 4 I SRTIMNRM001 86400.
(ONE DAY)
- HOT SPOT RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSHOT001 0.5 (50 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
'NORMAL RELOCATION DOSE CRITERION THRESHOLD (SIEVERTS)
SRDOSNRM001 0.25 (25 REM DOSE TO WHOLE BODY IN 1 WEEK TRIGGERS RELOCATION)
'EARLY FATALITY MODEL PARAMETERS, LOADED BY INEFAT, STORED IN IEFATAL/
- NUMBER OF EARLY FATALITY EFFECTS EFNUMEFA001 2 ORGNAM EFFACA EFFACB EFFTHR EFATAGRPOOI 'A-RED MARR' 3.8 5.0 1.5 EFATAGRP002 'A-LUNGS' 10.0 7.0 5.0
- EARLY INJURY MODEL PARAMETERS, LOADED BY INEINJ, STORED IN /EINJURI
- NUMBER OF EARLY INJURY EFFECTS EINUMEIN001 7 EINAME ORGNAM EISUSC EITHRE EIFACA EIFACB EINJUGRPOO1 'PRODROMAL VOMIT' 'A-STOMACH' 1.
.5
- 2.
3.
EINJUGRP002 'DIARRHEA'
'A-STOMACH' 1.
- 1.
- 3.
2.5 EINJUGRP003'PNEUMONITIS'
'A-LUNGS'
- 1.
- 5.
- 10.
7.
EINJUGRP004 'SKIN ERYTHEMA' 'A-SKIN'
- 1.
- 3.
- 6.
5.
EINJUGRP005 TRANSEPIDERMAU 'A-SKIN'
- 1. 10.
- 20.
5.
EINJUGRP006 THYROIDITIS'
'A-THYROIDH' 1. 40. 240.
2.
EINJUGRP007 'HYPOTHYROIDISM' 'A-THYROIDH' 1.
- 2.
- 60.
1.3
- ACUTE EXPOSURE CANCER PARAMETERS, LOADED BY INACAN STORED IN /ACANCRI.
'NUMBER OF ACUTE EXPOSURE CANCER EFFECTS LCNUMACA001 7
'THRESHOLD DOSE FOR APPLYING THE DOSE DEPENDENT REDUCTION FACTOR LCDDTHRE001 0.2 (LOWEST DOSE FOR WHICH DDREFA WILL BE APPLIED)
'DOSE THRESHOLD FOR LINEAR DOSE RESPONSE (Sv)
LCACTHRE001 0.0 (LINEAR-QUADRATIC MODEL IS NOT BEING USED)
ACNAME ORGNAM ACSUSC DOSEFA DOSEFB CFRISK CIRISK DDREFA LCANCERS001 'LEUKEMIA'L-REDMARR' 1.0 1.0 0.0 9.70E-3 0.0 2.0 LCANCERS002'BONE'
'1-BONE SUR' 1.0 1.0 0.0 9.OOE-4 0.0 2.0
Alicia Williamson - ears2p.txt Page 5 LCANCERS003'BREAST' 'L-BREAST' 1.0 1.0 0.0 5.40E-3 1.7E-2 1.0 LCANCERS004'LUNG'
'L-LUNGS' 1.0 1.0 0.0 1.55E-2 0.0 2.0 LCANCERS005 'THYROID' 'L-THYROIDH' 1.0 1.0 0.0 7.20E-4 7.2E-3 1.0 LCANCERS006'Gr'
'L-LOWERLI' 1.0 1.0 0.0 3.36E-2 0.0 2.0 LCANCERS007'OTHER'
'L-EDEWBODY' 1.0 1.0 0.0 2.76E-2 0.0 2.0
" RESULT 1 OPTIONS BLOCK, LOADED BY INOUT1, STORED IN IINOUTI/
" TOTAL NUMBER OF A GIVEN EFFECT (LATENT CANCER, EARLY DEATH, EARLY INJURY)
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPEINUMBER 4
TYPEIOUT001
'ERL FAT/TOTAL' 1 15 NOCCDF (0 TO 50 MILES)
TYPElOUT009
'CAN FAT/TOTAL' 1 15 NOCCDF TYPEIOUT019
'CAN FAT/TOTAL' 1 11 NOCCDF (OTO 10 MILES)
TYPEIOUT020
'ERL FAT/TOTAL' 1 11 (0 TO 10 MILES)
"RESULT 2 OPTIONS BLOCK, LOADED BY INOUT2, STORED IN /INOUT2/
" FURTHEST DISTANCE AT WHICH A GIVEN RISK OF EARLY DEATH IS EXCEEDED.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE2NUMBER 0 FATALITY RISK THRESHOLD
- TYPE2OUT001 0.
- RESULT 3 OPTIONS BLOCK, LOADED BY INOUT3, STORED IN /INOUT3/
" NUMBER OF PEOPLE WHOSE DOSE TO A GIVEN ORGAN EXCEEDS A GIVEN THRESHOLD.
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE3NUMBER 0 ORGAN NAME DOSE THRESHOLD (Sv)
- TYPE3OUT001
'A-RED MARR' 1.5
- TYPE3OUT002
'A-LUNGS' 5.0
- TYPE3OUT003
'L-EDEWBODY' 0.05
- RESULT 4 OPTIONS BLOCK, LOADED BY INOUT4, STORED IN /INOUT4/
- 360 DEGREE AVERAGE RISK OF A GIVEN EFFECT AT A GIVEN DISTANCE.
- POSSIBLE TYPES OF EFFECTS ARE:
- 'ERL FAT/TOTAL'
- 'ERL INJIINJURY NAME'
- 'CAN FAT/CANCER NAME'
'CAN FAT/TOTAL' 0
NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE4NUMBER 3
Alicia Williamson - ears2p.txt Pa~ie 6 I II Alicia Williamson - ears2p.txt Page 61 RADIAL INDEX TYPE4OUT001 I
TYPE4OUT002 2
TYPE4OUT003 3
TYPE OF EFFECT
'ERL FAT/TOTAL'
'ERL FAT/TOTAL' ERL FAT/TOTAL'
- RESULT 5 OPTIONS BLOCK, LOADED BY INOUT5, STORED IN INOUT5/
- TOTAL POPULATION DOSE TO A GIVEN ORGAN BETWEEN TWO DISTANCES.
NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE5NUMBER 1
0 ORGAN IIDIS5 12DIS5 TYPE5OUT001 'L-EDEWBODY 1
15 NOCCDF (0-50 MILES)
'RESULT 6 OPTIONS BLOCK, LOADED BY INOUT6, STORED IN /INOUT6/
- CENTERLINE DOSE TO AN ORGAN VS DIST BY PATHWAY, PATHWAY NAMES ARE AS FOLLOWS:
" PATHWAY NAME:
- 'CLD'
-CLOUDSHINE
- 'GRD'
-GROUNDSHINE
" 'INH ACU' - "ACUTE DOSE EQUIVALENT" FROM DIRECT INHALATION OF THE CLOUD
" 'INH LIF' - "LIFETIME DOSE COMMITMENT" FROM DIRECT INHALATION OF THE CLOUD
- 'RES ACU' - "ACUTE DOSE EQUIVALENT" FROM RESUSPENSION INHALATION
- 'RES LIF' - "LIFETIME DOSE COMMITMENT" FROM RESUSPENSION INHALATION
- TOT ACU' - "ACUTE DOSE EQUIVALENT" FROM ALL PATHWAYS
- TOT LIF'- "LIFETIME DOSE COMMITMENT" FROM ALL PATHWAYS
'NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE6NUMBER 0
ORGNAM PATHNM 11DIS6 12DIS6 0
'TYPE6OUT001 'A-RED MARR' TOT ACU' 1
19 (0-50 MILES)
'TYPE6OUT002 'A-LUNGS' TOT ACU' 1
19 (0-50 MILES)
'TYPE6OUT003 'L-EDEWBODY TOT LIF' 1
26 (0-1000 MILES)
'RESULT 7 OPTIONS BLOCK, LOADED BY INOUT7, STORED IN INOUT7/
'CENTERLINE RISK OF A GIVEN EFFECT VS DISTANCE
'NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE7NUMBER 0 NAME 11DIS7 12DIS7
'TYPE7OUT001
'ERL FAT/TOTAL' 1
TYPE7OUT002
'CAN FAT/TOTAL' 1
19 26 (0-50 MILES)
(0-1000 MILES)
I Alicia Williamson - ears2p.txt Page 7 -1 I l ic a W l i m o t
P a ge..
7..........
- RESULT 8 OPTIONS BLOCK, LOADED BY INOUT8, STORED IN /INOUT8/
- POPULATION WEIGHTED FATALITY RISK BETWEEN 2 DISTANCES
- NUMBER OF DESIRED RESULTS OF THIS TYPE TYPE8NUMBER 2 NAME 11DIS8 12DIS8 TYPE8OUT001 'ERL FAT/TOTAL' 1 3
NOCCDF TYPE8OUT002 'CAN FAT/TOTAL' 1 11 NOCCDF (0-10 MILES)
- RESULT A OPTIONS BLOCK, LOADED BY INOUTA, STORED IN /INOUTA/
- peak dose to a given organ NUMA TYPEANUMBER 0 ORGNAM IlDISA 12DISA
- 'TYPEAOUT001 'L-EDEWBODY' 1 15