Line 47: |
Line 47: |
| Bill Fitzgerald Nuclear Business Unit Vice President Fisher Controls International LLC 205 South Center Street Marshalltown, IA 50158 Fax: (641) 754-2854 Equipment Affected By This Information Notice: | | Bill Fitzgerald Nuclear Business Unit Vice President Fisher Controls International LLC 205 South Center Street Marshalltown, IA 50158 Fax: (641) 754-2854 Equipment Affected By This Information Notice: |
| ORDERS PROCESSED BY POSI-SEAL INTERNATIONAL THAT USED GASKET RETAINER HEX HEAD CAP SCREWS PROVIDED BY TEXAS BOLT COMPANY ORDER 204653 (POSI-SEAL PART NUMBER 131550, DRAWING NUMBER 5200-001) | | ORDERS PROCESSED BY POSI-SEAL INTERNATIONAL THAT USED GASKET RETAINER HEX HEAD CAP SCREWS PROVIDED BY TEXAS BOLT COMPANY ORDER 204653 (POSI-SEAL PART NUMBER 131550, DRAWING NUMBER 5200-001) |
| Purpose: | | |
| | ==Purpose:== |
| The purpose of this Fisher Information Notice (FIN) is to notify customers of an issue reported to us by Duke Energy. | | The purpose of this Fisher Information Notice (FIN) is to notify customers of an issue reported to us by Duke Energy. |
| We have informed our customers of record of this circumstance in accordance with 21.21 (b) of 10CFR21 because Fisher Controls International LLC, is not aware of each and every application or system design and cannot determine whether an anomaly could cause a defect or "failure to comply," relating to a substantial safety hazard. In particular, this Information Notice deals with customer orders that used improperly heat treated cap screws provided by Texas Bolt Company (Texas Bolt Order 204653, Certified by Texas Bolt Company, April 20, 1987). | | We have informed our customers of record of this circumstance in accordance with 21.21 (b) of 10CFR21 because Fisher Controls International LLC, is not aware of each and every application or system design and cannot determine whether an anomaly could cause a defect or "failure to comply," relating to a substantial safety hazard. In particular, this Information Notice deals with customer orders that used improperly heat treated cap screws provided by Texas Bolt Company (Texas Bolt Order 204653, Certified by Texas Bolt Company, April 20, 1987). |
Revision as of 04:03, 7 December 2019
Notification of Potential Part 21 Report (Draft) Re Defective ASME SA-193, Grade 6 Cap Screw MaterialML090410485 |
Person / Time |
---|
Site: |
Mcguire, Indian Point, Catawba, McGuire |
---|
Issue date: |
02/06/2009 |
---|
From: |
Farrell M Fisher Controls International |
---|
To: |
Office of New Reactors, Office of Nuclear Reactor Regulation, NRC Region 1, NRC/RGN-II, NRC/RGN-III, NRC Region 4 |
---|
References |
---|
44836, SA-193 |
Download: ML090410485 (8) |
|
|
---|
Category:Deficiency Report (per 10CFR50.55e and Part 21)
MONTHYEARML23207A0762023-07-14014 July 2023 EN 56557 - Update to Part 21 Report Re Potential Defect with Trane External Auto/Stop Emergency Stop Relay Card Pn: XI2650728-06 ML23066A2212023-03-0707 March 2023 Velan, Inc. - Revised Part 21 Notification Re Butterfly Valves Found to Have a Number of Fasteners Loose ML22303A0042022-08-31031 August 2022 Final Report Notification Pursuant to 10 CFR Part 21.21, Regarding Supply of 6 NPS Sch. 40 Seamless Stainless-Steel Pipe; Manufacturer: Maxim Tubes Company Pvt. Ltd.; Heat No: N200309AW01, SR No: 7; 9 Pcs; 180 Feet Total Procured as Unquali ML22259A1732022-08-26026 August 2022 EN 55960 - Curtiss Wright Part 21 Report Re Potential Defect in Configuration of the Quick Disconnect Connector Cable Assemblies Supplied to McGuire and Catawba Nuclear Power Stations ML22201A1012022-07-18018 July 2022 Framatome, Inc. - 10 CFR Part 21 Notification of Existence of a Defect and Failure to Comply ML22222A0092022-07-0101 July 2022 EN 55974 - Flowserve, Part 21 Report Re Solenoid Coil Failure of Model 38878-8 Solenoid Valve at Catawba Nuclear Station for Use on FWIV Actuator RA-22-0127, Interim Part 21 Report of a Deviation or Failure to Comply for Cutler-Hammer Relay2022-04-0808 April 2022 Interim Part 21 Report of a Deviation or Failure to Comply for Cutler-Hammer Relay ML21225A0812021-08-0404 August 2021 Lake Engineering Co., Final Report Per 10 CFR Part 21 Degraded Snubber SF1154 Hydraulic Fluid Batch No. 17BLVS293 ML20136A2552020-04-21021 April 2020 10 CFR Part 21 Report Notification for Curtiss Wright Scientech Certain RTL500 and RTL851 Modules ML20073G4572020-03-0909 March 2020 Carrier Corporation - Final Report Notification of Defect Pursuant to 10 CFR Part 21 for 17FA999-1200-107 Oil Pump ML20016A2202020-01-10010 January 2020 Carrier - Interim Report/Notification of Defect Pursuant to 10 CFR Part 21 ML20024D8232020-01-10010 January 2020 Carrier Corp., Interim Report/Notification of Defect Pursuant to 10 CFR Part 21 ML19346H8732019-12-12012 December 2019 Westinghouse Electric Company - Notification of the Potential Existence of Defect Pursuant to 10 CFR Part 21 ML19347A4262019-12-10010 December 2019 General Atomics - Reportable Occurrence Under 10CFR21: Reported Failure in Analog High Range Radiation Monitor (RP-2C) ML19261A1942019-09-0606 September 2019 Final Report (Log # 2019-22-00) (Event# EN 54215) - Non-Destructive Examination (Liquid Penetrant) Performance of Components by an Un-Qualified Employee ML19071A1122019-03-0101 March 2019 Lake Engineering Co., Corrected Potentially Degraded Snubber SF1154 Hydraulic Fluid Batch 11KLVS146 Final Report, Per 10 CFR Part 21 ML18302A2282018-10-19019 October 2018 Itt Enidine - USNRC 10CFR Part 21 Notification ML18269A1122018-09-12012 September 2018 Engine Systems, Inc. Report No. 10CFR21-0122, Rev. 0 - 10CFR21 Reporting of Defects and Non-Compliance ML17194A8252017-07-11011 July 2017 Part 21 Report Re Wedge Pin Failure in Anchor Darling Motor Operated Double Disc Gate Valves with Threaded Stem to Upper Wedge Connections ML17173A1392017-06-0909 June 2017 Engine Systems, Inc. - Transmittal of 10CFR21 Reporting of Defects and Non-Compliance - Report No. 10CFR21-0117, Rev. 0 ML17165A4072017-06-0909 June 2017 Part 21 Report - Defective Motor Operated Potentiometer ML17081A4532017-03-20020 March 2017 Part 21 - Plastic Jar Dedication Sampling ML17026A4142017-01-20020 January 2017 C&D Technologies, Inc. - Part 21 - Plastic Jar Dedication Sampling ML16328A3102016-11-18018 November 2016 Notification of the Potential Existence of Defects Pursuant to 10 CFR Part 21 ML16321A4512016-10-21021 October 2016 Part 21 Reporting of Defects and Noncompliance MNS-16-078, Written Notification Joslyn Clark Overload Heater Element Part No. 24552016-10-19019 October 2016 Written Notification Joslyn Clark Overload Heater Element Part No. 2455 ML16294A2642016-10-18018 October 2016 Part 21 Report - Defective Current to Pressure Transducers ML16281A2712016-09-30030 September 2016 Part 21 - Safety Related Component Welding by an Unqualified Welder ML16278A4712016-09-22022 September 2016 Notification of 10 CFR Part 21 Condition, Masterpact Breaker Fail to Close ML16281A2702016-09-22022 September 2016 Part 21 - Initial Notification of Masterpact Breaker Fail to Close ML16281A2722016-09-19019 September 2016 Part 21 Notification - Joslyn Clark Overload Heater Element Part Number 2455 ML16251A0982016-09-0202 September 2016 Part 21 - Potential Failure of Battery System Connections ML16243A4752016-08-26026 August 2016 Part 21 Safety Related Component Welding by an Unqualified Welder ML16243A4722016-08-25025 August 2016 Part 21 Reporting of Defects and Noncompliance ML16209A0502016-07-13013 July 2016 Part 21 - Furmanite Nuclear Grade Leak Seal Material FSC-N-1B ML16196A0642016-07-10010 July 2016 Part 21 Report - Materials Not Properly Dedicated ML16139A8322016-05-13013 May 2016 Part 21 - Initial Notification of Masterpact Breaker Fail to Close ML16139A8332016-05-13013 May 2016 Part 21 - Initial Notification of Masterpact Breaker Fail to Close ML16139A8342016-05-10010 May 2016 Electroswitch - Transmittal of 10CFR Part 21 Reporting of Defects and Noncompliance Regarding Vendor Inspection of Electroswitch Corporation Docket No. 99900833 ML16127A5952016-05-0404 May 2016 Rotork Controls Inc. Part 21 Notification Concerning V12 (Pt No. N69-921) and K5 (N69-838 & N69-926) Safety Related Micro Switches ML16076A2612016-03-11011 March 2016 Part 21 - Commercial Grade Cap Screws Provided with Safety Related Fisher Type 3570 Positioners ML16258A4562015-11-0505 November 2015 Part-21 Report - Closed Switch Not Actuating When Valve Is Fully Closed ML15303A0062015-10-26026 October 2015 Part 21 Report Regarding Closed Switch No. Actuating When Valve Is Fully Closed, Per Catawba Nuclear Station ML15205A2892015-07-24024 July 2015 Notification of Part 21 Report - Deviation in Nozzle Modeling Internal Reports ML15188A0662015-06-25025 June 2015 Part 21 Report - Deviation in Nozzle Modeling Internal Reports ML15155A5752015-05-29029 May 2015 C&D Technologies, Inc. - Interim Report - Inability to Complete 10CFR Part 21 Evaluation Regarding Cracking in KCR-13 Standby Battery Jars at Indian Point ML15155A5762015-05-29029 May 2015 C&D Technologies, Inc., Interim Part 21 Report - Inability to Complete Evaluation Regarding Cracking in KCR-13 Standby Battery Jars at Indian Point ML15103A4852015-04-0707 April 2015 Itt Engineered Valves - 2nd Interim Report to the NRC of 10 CFR 21 Event 50285, Reported by Itt 07/18/14 Concerning M I Diaphragms, Customer Testing ML15103A2442015-04-0606 April 2015 Part 21 Report - Deviation of Hk Circuit Breaker Close Latch Spring ML15089A4372015-03-20020 March 2015 Part 21 - Dual Alarm Modules That May Contain Faulty Diodes in Single State Relays 2023-07-14
[Table view] |
Text
02/09/2009 U.S. Nuclear Regulatory Commission Operations Center Event Report Page 1 General Information or Other (PAR) Event # 44836 Rep Org: FISHER CONTROLS INTERNATIONAL Notification Date / Time: 02/06/2009 15:54 (EST)
Supplier: FISHER CONTROLS INTERNATIONAL Event Date / Time: 02/06/2009 (CST)
Last Modification: 02/06/2009 Region: 3 Docket #:
City: MARSHALLTOWN Agreement State: Yes County: License #:
State: IA NRC Notified by: MATTHEW FARRELL Notifications: MARK RING R3 HQ Ops Officer: VINCE KLCO HAROLD GRAY R1 Emergency Class: NON EMERGENCY STEVEN RUDISAIL R2 10 CFR Section: JEFF CLARK R4 21.21 UNSPECIFIED PARAGRAPH OMID TABATABAI-EMAIL NRO TOM HERRITY-EMAIL NRR PART 21 REPORT - DEFECTIVE ASME SA-193, GRADE 6 CAP SCREW MATERIAL The following information was obtained from Fisher Controls International via facsimile:
Fisher Information Notice (FIN 2009-01, dated February 2, 2009) was issued to notify customers of an issue reported to Fisher by Duke Energy.
"[Fisher has] informed [their] customers of record of this circumstance in accordance with 21.21 (b) of 10CFR21 because Fisher Controls International LLC, is not aware of each and every application or system design and cannot determine whether an anomaly could cause a defect or "failure to comply," relating to a substantial safety hazard. In particular, this Information Notice deals with customer orders that used improperly heat treated cap screws provided by Texas Bolt Company (Texas Bolt Order 204653, Certified by Texas Bolt Company, April 20, 1987). Receipt of this notice does not necessarily mean that the recipient has been shipped any of the subject equipment. It is expected that the recipients of this notice will review the information for applicability to their facilities, and if required, take the appropriate action as described in the section at the end of this notice.
"This notice applies only to customer orders processed by Posi-Seal International that used the 100 quantity lot of hex head cap screws identified by Texas Bolt Company Material Certification Report Number 001.87-1758, certified by Texas Bolt Company, April 20, 1987.
"Fisher was informed by Duke Energy that there have been failures of ASME SA-193 Grade B6 hex head cap screws at the Catawba Nuclear Station. These bolts are used on various size Posi-Seal butterfly valves to maintain a pressure seal on the outboard side of the valve body. Failure of these bolts will impair the pressure
02/09/2009 U.S. Nuclear Regulatory Commission Operations Center Event Report Page 2 General Information or Other (PAR) Event # 44836 retaining capability of the valve body.
"Based on the experiences at Duke Energy, it is possible that a defective batch of cap screws were used by Posi-Seal around 1987. Fisher Controls International has attempted to determine a complete list of valve serial numbers that may have used bolts from this particular lot. Unfortunately, Fisher Controls International's review of available Posi-Seal records cannot provide validation of its completeness.
"It is recommended that customers verify if the QA documentation package, provided with the valve, contains a copy of the cap screw material certification attached to this information notice. If so, Fisher Controls International recommends that the subject cap screws be replaced.
"Fisher Controls requests that the recipient of this notice review it and take appropriate action in accordance with 10CFR21.
"If there are any technical questions or concerns, contact:
Michael Wedemeyer Manager, Quality Fisher Controls International LLC 205 South Center Street Marshalltown, IA 50158 Fax: (641) 754-2854 Phone: (641) 754-2066 Michael.Wedemeyer@.Emerson.com" Possible domestic constructions with defective cap screw material (Posi-Seal part number 131550, drawing number 5200-001) include McGuire, Catawba and Indian Point.