ML16243A472

From kanterella
Jump to navigation Jump to search
Part 21 Reporting of Defects and Noncompliance
ML16243A472
Person / Time
Site: Hatch, Monticello, Indian Point, Wolf Creek, Point Beach, Watts Bar, Cooper, Pilgrim, Prairie Island, Vogtle, Waterford, 99900833  
Issue date: 08/25/2016
From: Friedman L
Electroswitch
To:
Office of Nuclear Reactor Regulation
References
Download: ML16243A472 (7)


Text

0812612016 U.S. Nuclear Regulatory Commission Operations Center Event Report

Rep Org: ELECTROSWITCH Supplier: ELECTROSWITCH Region: 1 Event#

Notification Date I Time: 05/10/2016 15:59 Event Date I Time: 05/10/2016 Last Modification: 08/25/2016 Docket #: 99900833 City: WEYMOUTH County:

Agreement State:

Yes State: MA NRC Notified by: LARRY FRIEDMAN HQ Ops Officer: BETHANY CECERE Emergency Class: NON EMERGENCY 10 CFR Section:

21.21(d)(3)(i)

DEFECTS AND NONCOMPLIANCE License#:

Notifications: ART BURRITT JAMIE HEISSERER ERIC DUNCAN VIVIAN CAMPBELL PART 21/50.55 REACTORS PART 21 REPORTING OF DEFECTS AND NONCOMPLIANCE The following is a synopsis of information received via fax:

Pagel 51915 (EDT)

(EDT)

R1DO R2DO R3DO R4DO EMAIL "Various Electroswitch products - Series 24 Instrument & Control (Part #24XX, 24XXX, 243XX, 74XXX), Series 24 LOR (part #78XX), Series 24 LOR/ER (part #78XX), Series 24 CSR (part #88XX), Series 24 LSR (part #92XX),

Series 31 Instrument & Control (part #31XXX, 65XXX, 75XXX), Series 31 TR/LSR (part #93XX), Series 20 Cam (part #20KB, 20KD, 20LB, 20LD, 20MB, 20MD, 20MF, 20MG, 20PF, 20PG, 20PH, 20PJ, 20PL, 20PY), Series 20 Module (part#10XXX, 17XXX, 18XXX, 19XXX, 29XXX, 30XXX, 32XXX,38XXX,40XXX, 60XXX, 61XXX, 62XXX, 63XXX) [have a potential deviation (departure from the technical requirements included in the procure document)]

"It was determined on May 10, 2016 that Electroswitch does not have the capability to perform the evaluation to determine if a defect, which could create a substantial. safety hazard, exists.

.Any Electroswitch product that has a part number listed above and was sold as a Safety-Related Class 1 E product [may contain the deviation].

The two nonconformance issues are:

"Initial Product Qualification Tests for Dielectric Withstanding Voltage, Insulation Resistance and Contact Resistance as defined in Electroswitch's ESC-STD-1000 Rev. 3 dated 9/3/1984 General Specifications for Rotary Switches and Auxiliary Relays for Utility Applications including Class 1 E Equipment for Nuclear Power Generating Stations was found to be in contradiction to IEEE C37.90-1978 Relays and Relay Systems Associated with Electric Power Apparatus.

0812612016 U.S. Nuclear Regulatory Commission Operations Center Event Report Page 2 "Electroswitch did not procure materials, parts, equipment and/or services from an Appendix B supplier nor were applicable Commercial Grade Surveys, Source Inspections and Material Analyses performed for the following materials:

Precious metal blade overlay material Red metal blade material Precious metal overlay thickness of switch blade material Molding compound of switch insulators (terminal decks and barriers)

Carbon steel for securing rods Solenoids Relays Services (test labs) pertaining to product qualification Electroswitch is attempting to determine which NRC licensees are potentially affected.

"The following personnel may be contacted regarding this notification:

Larry Friedman Quality Assurance Manager 781-607-3309 Ed Reszenski Engineering Manager 781-607 -3341"

      • UPDATE FROM LARRY FRIEDMAN TO DONALD NORWOOD AT 1656 EDT ON 5/11/2016 * *
  • The following information was received via fax:

Below is the list of utilities (and plants where specified) which were notified of Electroswitch's decision to end the Appendix B Quality Assurance Program:

Ameren Energy Dominion Energy Duke Energy Energy Northwest Entergy Nuclear (Waterford 3 Nuclear)

Entergy Nuclear (Pilgrim Power Plant)

Entergy Nuclear (Indian Point Energy)

Xcel Energy (Monticello Nuclear)

MPR Associates for FPL Nebraska Public Power (Cooper Nuclear)

Nextera (Point Beach Nuclear)

Xcel Energy (Prairie Island Gen)

Southern Power (Hatch)

0812612016 U.S. Nuclear Regulatory Commission Operations Center Event Report Page3 Southern Power (Vogtle)

TVA TVA (Watts Bar Nuclear)

Wolf Creek Nuclear Notified R1 DO (Burritt), R2DO (Heisserer), R3DO (Duncan) and R4DO (Campbell) and via E-mail Part 21/50.55 Reactors Group.

      • UPDATE FROM LARRY FRIEDMAN TO DONG HWA PARK AT 1617 EDT ON 8/25/2016 * *
  • The following information was received via fax:

"Electroswitch is formally requesting a thirty (30) day extension to complete the evaluation by Sept. 24, 2016 in order to provide detailed answers to the questions and provide any needed updates to the Part 21 notification report."

Notified R1 DO (Dimitriadis), R2DO (Michel), R3DO (Cameron) and R4DO (Kellar) and Part 21/50.55 Reactors Group via E-mail.

AUG/25/2016/THU 03:02 PM Electroswitch-Sales e

~f!rfr:~~~§fl'&~l/

UNJTQFELECTRD SWITCH CORP.

180 King Avenue Weymouth, MA 02188 Phone: 781-335-5200 Fax: 781-331"3798 Attention: NRC Operations Cente:r Company: U. S. Nuclear Regulatory Commission Fax#: 301-816-5151 From: Larry Friedman Quality Assurance Mau.ager Phone:

781-607-3309 FAX No. 781-335-4253 P. 001 Date: August 25, 2016

  1. of Pages: 4 (including cover)

Attached is a Request for Extension for Interim Part 21 to address the notice of nonconformance from the Vendor Inspection of Electroswitch Corporation Report No. 99900833/2016-201.

Reference:

Event #51915

AUG/25/2016/THU 03:02 PM Electroswitch-Sales e

ELECTROSWITCH *SWITCHES & RELAYS UNIT OF ~LE.CfRO SWITCH CORP.

FAX No. 781-335-4253 P. 002 180 King Avenue Weymouth, MA 02188 e

Phone 781-335~5200 e Fax 781-335-4253 August 25, 2016 U. S. Nuclear Regulatory Commission

_ NRC Operations Center Facsimile# 30lw816-5151

Subject:

Request for Thirty (30) Day Extension for Interim Part 21 Report

Reference:

10 CFR Part21 Reporting of Defects and Noncompliance - Vendor Inspection of Electroswitch Corporation Docket #99900833 (Event #51915)

To Whom It May Concern:

Electtoswitch is formally requesting a thirty (30) day extension to complete the evaluation by Sept. 24, 2016 in order to provide detailed answers to the questions and provide any needed updates to the Part 21 notification report.

Electroswitch had opened a formal Interim Part 21 Report to address the notice of nonconfon:o.ance from the Vendor Inspection of Electro switch Corporation Report No.

99900833/2016w201. Tue nonconformances were:

NON 99900833/2016-201-01: Criterion III, Design Control, of 10CFR50 Appendix B m part states "Measures shall be established to assure that applicable regulatory requirements and the design basis, as defined m § 50.2 and as specified in the license application, for those structures, systems, and components to which this appendix applies are correctly translated into specifications, drawings, procedures, and instructions. These measures shall include provisions to assure that appropriate quality standards are specified and included in design documents and that deviations from such standards are controlled.".

Electroswitch's ESC-STD-1000 Rev. 3 dated 9/3/1984 General Specifications for Rotazy Switches and Auxiliary Relays for Utility Applications inclucling Class IE Equipment for Nuclear Power Generating Stations.states the following:

1. Dielectric Withstanding Voltage -2200VRMS, 60Hz for one minute with a maximum of 100 microamps leakage initially a11d 600VRMS, 60Hz for one nrlnute with a maximum of 100 milliamps after aging.
a. This is contrary to contrary to IEEE C37.90-1978 Relays and Relay Systems Associated with Electric Power Apparatus.
2. Insulation Resistance - 100 megohms miuimum at 500VDC for one minute and 50.m.egobms minimum at 500VDC for one minute after endurance and aging.
a. This is contrary to paragraph 3.8 of ESC-STD-1000 Rev. 3 dated 9/311984, which states 100 megohms minimum.

AUG/25/2016/THU 03:02 PM Electroswitch-Sales FAX No. 781-335-4253 P. 003

~

ELECTROSWITCH *SWITCHES & RELAYS

~

UN/TDF ELECTRO SWITCH CDfi.P.

180 King Avenue Weymouth, MA 02188 Phone 781-335-5200

  • Fax 781M3354253
3. Contact Resistance - 10 roilliobm.s maximum at rated current and 1 O millioluns at 100 milliamps after endmance.

a Thls is contrary to paragraph 3.9 of ESC-STD-1000 Rev. 3 dated 9/3/1984, which states 10 milliohms maximum at rated current.

NON 99900833/2016-201-02: Criterion III, Design Control, of 10CFR.50 Appendix B in part states '~easures shall also be established for the selection and review for suitability of application of materials, parts, equipment, and processes that are essential to the safety~related functions of the structures, systems and components."

Electroswitch did not procure materials, parts, equipment and/or services from an Appendix B supplier nor were applicable Commercial Grade Surveys, Source Inspections and Material analyses performed for the following materials:

Precious metal blade overlay material Red metal blade material Precious metal overlay thickness of switch blade material Molding compound of switch insulators Carbon steel for securing rods Solenoids Relays Services pertaiJJ.ing to product qualification Electroswitch had submitted formal corrective action reports (CAR# 16-010 and CAR #16~011) to the NRC and to the affected utilities. The NRC had revievved the docu:rnents and have subsequently asked questions related to the responses (reference letter from Terry Jackson dated August 5, 2016). In addition, a request by the NRC was to provide additional technical details for the descriptions of both findings and an updated list of affected utilities, if need be~ to the P<Ui:

21 notification report.

Electroswitch has continued to respond to direct questions from*the utilities during tbis evaluation.

Please sign below, acknowledging receipt of this request, and return a copy to the attention of Larry Friedman, Quality Assurance Manager, at the above address or fax to 781-335-4253 within 10 working days after receipt.

Sincerely, ELECTRO SWITCH

~

LafrYFrid1l13!l Quality Assurance Manager

AUG/25/2016/THU 03:03 PM Electroswitch-Sales

~

ELECTRDSWITCH *SWITCHES & RELAYS

~

UNITOF £lEcmO SW/tCH CORP.

FAX No. 781-335-4253 P. 004 180 King Avenue

  • Weymouth, MA 02188 Phone 781~335-5200
  • t=ax 781-335-4253 Please let us know if ANY of your mailing information changes - name of recipient, name of company/facility, address, etc. Mark the changes on this acknowledgement form and send to us by mail to the address above or by FAX to 781-335-4253.

RECEIVED: __________ _

DATE: