Line 2: |
Line 2: |
| | number = ML070300227 | | | number = ML070300227 |
| | issue date = 02/06/2007 | | | issue date = 02/06/2007 |
| | title = Facsimile Transmission of Draft Request for Additional Information on Emergency Action Level Revision (TAC Nos. MC9456, MC9459, MC9460, MC9461, and MC9462) | | | title = Facsimile Transmission of Draft Request for Additional Information on Emergency Action Level Revision |
| | author name = Martin R | | | author name = Martin R |
| | author affiliation = NRC/NRR/ADRO/DORL/LPLII-1 | | | author affiliation = NRC/NRR/ADRO/DORL/LPLII-1 |
Letter Sequence Draft RAI |
---|
TAC:MC9456, (Open) TAC:MC9457, (Approved, Closed) TAC:MC9459, (Approved, Closed) TAC:MC9460, (Approved, Closed) TAC:MC9461, (Approved, Closed) TAC:MC9462, (Approved, Closed) |
|
MONTHYEARML0600601102005-12-28028 December 2005 Fourth 10-Year Interval Pump and Valve Inservice Testing Program Project stage: Request ML0605900892006-02-27027 February 2006 Draft RAI on Pump and Valve Relief Requests Project stage: Draft RAI ML0616403122006-06-0202 June 2006 Fourth 10-Year Interval Pump and Valve Inservice Testing Program - Request for Additional Information Project stage: Request ML0617301752006-06-28028 June 2006 D.C. Cook, Relief, Relief Requests for the Fourth 10-Year Pump and Valve Inservice Testing Program Interval Project stage: Other ML0621500282006-08-0404 August 2006 )Rai'S, Hatch, Units 1 & 2, Farley, Units 1 & 2 and Vogtle, Units 1 & 2, RAI, Emergency Plan Revision Project stage: RAI ML0620606192006-08-0404 August 2006 RAI, Emergency Plan Revision Project stage: RAI ML0703002272007-02-0606 February 2007 Facsimile Transmission of Draft Request for Additional Information on Emergency Action Level Revision Project stage: Draft RAI ML0711000682007-04-30030 April 2007 Safety Evaluation, Emergency Action Level Revisions for Southern Nuclear Operating Company, Inc (TAC MC9459, MC9460, MC9458, MC9461, & MC9462) Project stage: Approval AEP-NRC-2015-31, Submittal of 10 Cer 50.55a Requests Associated with the Fifth Ten-Year Inservice Testing Interval2015-07-31031 July 2015 Submittal of 10 Cer 50.55a Requests Associated with the Fifth Ten-Year Inservice Testing Interval Project stage: Other 2006-06-28
[Table View] |
|
---|
Category:Memoranda
MONTHYEARML24199A2072024-07-24024 July 2024 TS 3-6-5 LAR - Individual Notice Transmittal Letter and NSHC - Rev 1 (1) - Letter ML24138A0092024-05-17017 May 2024 Public Meeting Summary - 2023 Annual Assessment Meeting for Joseph M. Farley, Units 1 and 2 Docket No. 50-348, and 50-364 -Meeting Number 20240474 ML24123A0502024-05-0202 May 2024 2023 Annual Assessment Public Meeting Summary Meeting Number 20240479 ML24122C6202024-05-0101 May 2024 Public Meeting Summary - 2023 Annual Assessment Meeting Vogtle Electric Generating Plant, Units 1, 2, 3, and 4 Docket Nos.. 50-424, 50-424, 52-025, and 52-026 Meeting Number 20240471 ML24047A2092024-02-22022 February 2024 Calendar Year 2023 Baseline Inspection Completion ML23325A2022024-01-16016 January 2024 CFR Part 52 Construction Lessons-Learned Report ML24004A2192024-01-0808 January 2024 Construction Reactor Oversight Process Performance Metric Report for Calendar Year 2023 ML23303A2032023-11-0101 November 2023 October 24, 2023, Summary of Comment Gathering Public Meeting on Lessons Learned from the ITAAC Hearing Process for Vogtle Units 3 and 4 ML22348A0862023-07-25025 July 2023 Finding in Accordance with 10 CFR 52.103(G) That All Acceptance Criteria Are Met for Vogtle Electric Generating Plant, Unit 4 ML23146A1672023-05-31031 May 2023 Public Meeting Summary2022 Annual Assessment Meeting for Joseph M. Farley, Units 1 and 2 Docket No. 50?348, and 50?364 Meeting Number 20230610 ML23115A0382023-05-0909 May 2023 Summary of Readiness Group Public Meeting on April 20, 2023 ML23115A0662023-05-0101 May 2023 Summary of Public Meeting with Southern Nuclear Operating Company to Have Presubmittal Meeting for Vogtle Electric Generating Plant, Unit 4 IR 05000424/20040252023-04-28028 April 2023 Public Meeting Summary - Vogtle Electric Generating Plant, Units 1, 2, 3, & 4 Docket No. 5000424, 5000425, 5200025, 5200026, Meeting Number 20230375 ML22214B4882023-02-0808 February 2023 Initial Commission Memo Regarding Status of ITAAC Closure, Inspection, and Licensing Activities for Vogtle Electric Generating Plant, Unit 4 ML22355A0322023-01-0303 January 2023 Revised Charter for the Vogtle Readiness Group to Oversee the Transition to Operations for Vogtle Units 3 and 4 ML22334A0812022-12-0101 December 2022 Update to Targeted Inspections, Tests, Analysis, and Acceptance Criteria for Vogtle Electric Generating Plant Unit 4 ML22322A1672022-11-28028 November 2022 Summary of 11/15/2022 Public Meeting on Lessons Learned ML22237A0782022-08-0505 August 2022 American Nuclear Insurers, Notification of Change in the Number of Power Reactors in the Secondary Financial Protection (SFP) Program ML20290A2812022-08-0101 August 2022 103g - Final Memorandum ML22123A0652022-05-0202 May 2022 Public Meeting Summary Vogtle Electric Generating Plant, Units 1, 2, 3, & 4 Docket No. 50-424, 50-425, 52-025, 52-026, Meeting Number 20220330 ML22108A1382022-04-18018 April 2022 Annual Assessment Public Meeting Summary ML21337A0032021-12-0707 December 2021 Summary of Vogtle Readiness Group Public Meeting on December 2, 2021 ML21322A1502021-12-0202 December 2021 Summary of November 10, 2021 Public Meeting with Southern Nuclear Operating Company ML21316A0692021-11-22022 November 2021 November 4, 2021 Summary of Public Meeting with Southern Nuclear Operating Company ML21280A2962021-10-22022 October 2021 Replacement of Page 2 to Letter Dated June 30, 2020, Titled License Amendment Request to Revise the Emergency Plan to Change Staffing and Extend Staff Augmentation Times for Emergency Response Organization Positions (EPID L-2020-LLA0150) ML21230A0102021-08-24024 August 2021 Summary of Public Meeting with Southern Nuclear Operating Company on August 12, 2021 ML21154A2772021-07-20020 July 2021 Summary of a Public Meeting with Southern Nuclear Operating Company on May 27, 2021 ML21194A0402021-07-20020 July 2021 Summary of June 24, 2021 Public Meeting with SNC ML21190A0622021-07-16016 July 2021 Summary of July 8 2021 Public Meeting to Discuss Late-Filed Allegation Process for Vogtle Electric Generating Plant Units 3 and 4 ML21194A0392021-07-16016 July 2021 July 8, 2021 Summary of Public Meeting with Southern Nuclear Operating Company ML21124A2032021-05-0606 May 2021 ASME Alternative ALT-16 Pre-submittal Meeting Summary 4-29-21 ML21123A1432021-05-0505 May 2021 April 22, 2021, Summary of a Public Meeting with Southern Nuclear Operating Company ML21124A1232021-05-0404 May 2021 April 27, 2021, Public Meeting Summary Joseph M. Farley Nuclear Plant Units 1 and 2, Edwin I. Hatch Nuclear Plant Units 1 and 2, Docket No. 50-348, 50-364, 50-321, 50-366, Meeting Number ML21117A030 ML20318A2422020-12-18018 December 2020 .72 50.73 Applicability Memo ML20351A2822020-12-10010 December 2020 Summary of Public Meeting with Southern Nuclear Operating Co ML20318A2412020-11-18018 November 2020 Summary of Public Meeting with Southern Nuclear Operating Company, to Discuss Topic Regarding Vogtle Electric Generating Plant, Unit 4: ITAAC Post Closure Notification for ITAAC Index Number 344 ML20303A0422020-11-0505 November 2020 Summary of October 22, 2020 Public Meeting with Southern Nuclear Operating Company NL-20-1262, Submission of Proposed Alternative to Submitting Vogtle Unit 2 Inservice Inspection Summary Report within 90 Days of Outage Completion2020-10-30030 October 2020 Submission of Proposed Alternative to Submitting Vogtle Unit 2 Inservice Inspection Summary Report within 90 Days of Outage Completion ML20296A2432020-10-15015 October 2020 Summary of 10-15-20 Public Meeting with Southern Nuclear Operating Company ML20283A4652020-10-15015 October 2020 Summary of Public Meeting on October 8, 2020 with Southern Nuclear Operating Company ML20279A5202020-10-0707 October 2020 October 1, 2020, Summary of Public Meeting with Southern Nuclear Operating Company ML20183A0902020-09-24024 September 2020 Initial Commission Memo Regarding Status of ITAAC Closure, Inspection, and Licensing Activities for Vogtle Electric Generating Plant, Unit 3 ML20262G9882020-09-22022 September 2020 September 17, 2020 Summary of Public Meeting with Southern Nuclear Operating Company ML20247J4812020-09-10010 September 2020 Summary for August 27, 2020 Public Meeting with Southern Nuclear Operating Company ML20248H3292020-09-10010 September 2020 Meeting Summary for September 3, 2020 Public Meeting with Southern Nuclear Operating Company ML20191A3832020-08-14014 August 2020 Transition to Reactor Oversight Process for Vogtle Electric Generating Plant, Units 3 and 4 ML20216A6252020-08-10010 August 2020 Summary of a Public Meeting with Southern Nuclear Operating Company on July 30, 2020 ML20216A6362020-08-10010 August 2020 Summary of a Public Meeting with Southern Nuclear Operating Company on July 23, 2020 ML20205L4312020-07-29029 July 2020 Summary of a Public Meeting with Southern Nuclear Operating Company to Discuss Inspections, Tests, Analyses and Acceptance Criteria Nos. 375 and 216 ML20178A1302020-07-15015 July 2020 Memorandum Transmitting Safety Evaluation Regarding Welded Reinforcement Bar Splices at Vogtle Electric Generating Plant Units 3 and 4 2024-07-24
[Table view] |
Text
February 6, 2007 MEMORANDUM TO: Evangelos C. Marinos, Chief Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Robert E. Martin, Sr. Project Manager /RA/
Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
FACSIMILE TRANSMISSION OF DRAFT REQUEST FOR ADDITIONAL INFORMATION ON EMERGENCY ACTION LEVEL REVISIONS (TAC NOS. MC9457, MC9456, MC9459, MC9460, MC9461, AND MC9462)
The Nuclear Regulatory Commission staff transmitted the enclosed draft request for additional information (RAI) to Southern Nuclear Operating Company, Inc. (SNC), on January 17, 2007. The draft RAI supported a conference call that was held with SNC on January 25, 2007, regarding SNCs submittal dated October 13, 2006, on the revisions of the emergency action levels for the Joseph M. Farley Nuclear Plant, Units 1 and 2, the Edwin I.
Hatch Nuclear Plant, Unit Nos. 1 and 2, and the Vogtle Electric Generating Plant, Units 1 and 2.
Docket Nos. 50-348, 50-364, 50-321, 50-366, 50-424 and 50-425
Enclosure:
Draft RAI
February 6, 2007 MEMORANDUM TO: Evangelos C. Marinos, Chief, Branch 2-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Robert E. Martin, Sr. Project Manager /RA/
Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
FACSIMILE TRANSMISSION OF DRAFT REQUEST FOR ADDITIONAL INFORMATION ON EMERGENCY ACTION LEVEL REVISIONS (TAC NOS. MC9457, MC9456, MC9459, MC9460, MC9461, AND MC9462)
The Nuclear Regulatory Commission staff transmitted the enclosed draft request for additional information (RAI) to Southern Nuclear Operating Company, Inc. (SNC), on January 17, 2007. The draft RAI supported a conference call that was held with SNC on January 25, 2007, regarding SNCs submittal dated October 13, 2006, on the revisions of the emergency action levels for the Joseph M. Farley Nuclear Plant, Units 1 and 2, the Edwin I.
Hatch Nuclear Plant, Unit Nos. 1 and 2, and the Vogtle Electric Generating Plant, Units 1 and 2.
Docket Nos. 50-348, 50-364, 50-321, 50-366, 50-424 and 50-425
Enclosure:
Draft RAI DISTRIBUTION:
PUBLIC PDII-1 R/F RidsNrrDorl (CHaney/TMcGinty) RidsNrrPMRMartin RidsNrrLAMOBrien RidsAcrsAcnwMailCenter RidsOgcRp RidsNrrPM(BSingal)
RidsRgn2MailCtr (SShaeffer) RidsNrrPMKCotton RidsNsirDJohnson RidsNrrLARSola ADAMS Accession Number: ML070300227 NRR-106 OFFICE NRR/LPL2-1/PM NRR/LPL2-1/LA NRR/LPL2-1/BC NAME RMartin MOBrien EMarinos DATE 02/5/07 02/5/07 02/6/07 OFFICIAL RECORD COPY
DRAFT REQUEST FOR ADDITIONAL INFORMATION (RAI)
REVISION OF EMERGENCY ACTION LEVELS (EAL)
SOUTHERN NUCLEAR OPERATING COMPANY, INC (SOUTHERN NUCLEAR)
I Joseph M. Farley Nuclear Plant
- 1. RAI-024(1) - RCS L4: The RAI response did not justify this logic as being AND. This is inconsistent with the other fleet EALs. Also, the hard-copy of the EAL Basis Document provided by the licensee does not match the electronic copy as the hard-copy shows a logic OR. Change to logic OR or provide rationale for the logic AND to allow NRC staff to reach the same conclusion. Also, verify that the hard-copy and electronic copy of the EAL Basis Document provided by the licensee are the same.
- 2. RAI-055(1) - SU4.1: The response to this RAI is unacceptable. The licensee needs to provide an acceptable alternative or prove that this condition is bounded by other EALs.
- 3. RAI-065(2) - SS6: Criteria a should be Significant Transient in Progress not Inability to Monitor a Significant Transient in Progress. These are two different statements and this was discussed during the 6/27/06 Teleconference. Correct the EAL.
II Edwin I. Hatch Nuclear Plant
- 1. RAI-001(4) - RU1.2: This EAL was deleted due to the licensee stating that they have no unmonitored release paths. However, this EAL is for non-routine release paths for which a discharge permit would not normally be prepared. Provide an acceptable alternative for this EAL or provide more justification as to why this EAL, or an alternative, cannot be provided.
- 2. RAI-003(4) - RA1.2: This EAL was deleted due to the licensee stating that they have no unmonitored release paths. However, this EAL is for non-routine release paths for which a discharge permit would not normally be prepared. Provide an acceptable alternative for this EAL or provide more justification as to why this EAL, or an alternative, cannot be provided.
- 3. RAI-019(5) - CA4: The notes are incorrect on the hard-copy provided by the licensee but is correct on the electronic copy. These are supposed to be identical. Correct the error and ensure that both documents are identical.
- 4. RAI-065(2) - SS6: Criteria a should be Significant Transient in Progress not Inability to Monitor a Significant Transient in Progress. These are two different statements and this was discussed during the 6/27/06 Teleconference. Correct the EAL.
Enclosure
III Vogtle Electric Generating Plant
- 1. RAI-004(2) - RA2: Based on your RAI response, explain why the alarm does not say Alert Alarm.
- 2. RAI-045(3) - HA1.5: Did not adequately address original RAI. Your justification for deleting this EAL does not account for the potential industrial safety hazards (e.g.,
electric shock) that preclude actions necessary to operate or monitor safety equipment.
Provide more justification or re-instate EAL.
- 3. RAI-055(1) - SU4.1: The response to this RAI is unacceptable. The licensee needs to provide an acceptable alternative or prove that this condition is bounded by other EALs.
- 4. RAI-065(2) - SS6: Criteria a should be Significant Transient in Progress not Inability to Monitor a Significant Transient in Progress. These are two different statements and this was discussed during the 6/27/06 Teleconference. Correct the EAL.
- 5. CU2.1: Another example of inattention to detail. The hard copy states greater than and the electronic copy states greater than or equal. These are supposed to be the same documents. Correct the error and make sure both documents are identical.