{{#Wiki_filter:Attachment A Remove Technical Specification pages 3.13-4 through 3.13-6.Xnsert attached Technical Specification pages 3.13-4 through 3.13-7.  
{{#Wiki_filter:Attachment A Remove Technical Specification pages 3.13-4 through 3.13-6.
.abl.e 3.13-l{Continued)
Xnsert attached Technical Specification pages 3.13-4 through 3.13-7.
Safety Related Shock Sluppressors (Snubbers)
 
Snubber Nark Ho.\APl'7-25 I I A I I Aux.Feedwater Accessibl.e or Inaccessible (A or I)Hspecia11y Elijah Radiation**
                                        .abl.e 3.13-l {Continued)
Ai f ficult to Zone Remove No AP'">-~6 l AFll~7 Aux.Peedwater Aux.Peedwater Uo No No No AFh'-20 APN-29 Aux.Feedwater"A",Aux.Feedwater No No AFN-31 IIAII Aux.Feedwater Uo No AP<'1-49'I F01-30 I FU-80"A" Aux.Feedwater"B" Feedwater"8" Peedwater No No No Ho No No FN-81't FW-82 I"8" Peedwater"B" Peedwater No No No Table 3.13-1 (Continued)
Safety Related Shock Sluppressors   (Snubbers)
Sachet Related Shock Suppressors (Snubbers)
Accessibl.e or                          Hspecia11y Inaccessible        Elijah Radiation** Aif ficult to Snubber Nark Ho.                                 (A or I)                Zone          Remove
Snubber.Mark No.Pi inq System Accessible or Inaccessible (A or I)Hiqh Radiation**
          \
Zone Especially Difficult to FN-03;I AFN-1 0 AF!'-1 3"8" Feedwater"8" Aux.Feedwa ter"B" Aux.Feedwater No bJo No'..Jo No bJo SbJB-265 Stm to TD Aux.Feedwater No HG-22"A" Hain Steam No No MS-8"B" Main Steam No Yes b1S-146 (Top)MS-146 (Bottom)"8" blain Steam"8" Main St.earn No No No Table 3.13-1 (Continued)
APl'7-25       II A II Aux. Feedwater                                                     No AP'">-~6               Aux. Peedwater                                    Uo                No l
Safety Related Shock Su pressors (Snubbers)
AFll ~7               Aux. Peedwater                                   No               No AFh'-20                 Aux. Feedwater APN-29         "A",Aux. Feedwater                                       No               No AFN-31         IIAII   Aux. Feedwater                                   Uo               No AP<'1-49'I     "A" Aux. Feedwater                                       No                Ho F01-30          "B" Feedwater                                             No                No I
Snubber Hark No.Pinin S stem Accessible or Inaccessible (A or I)Especially High Radiation**
FU-80          "8" Peedwater                                             No               No FN-81           "8" Peedwater                                             No                No "B" Peedwater
Difficult to Zone Remove 4)4J I Ch HG-147-.HS-148>HS-159 HS-160'E" t1ain Steam"E" Haz.n Steam"E" Hain Steam"E" Hain Steam No No No No No H-1 I'-2 H-3 0 H-4 H 5 I, PRZR Relief PR?R Belief PRZR Pe 1 ie f PRZR Relief PPZR Relief Yes Yes Yes Yes Yes No No H-6 H-7 El-8 K PRZR Relief PRZR Relief PPZR Relief Yes Yes Yes No Table 3.13-1 (Continued)
          't FW-82                                                                    No I
Safet Related Shock Suppressors (Snubbers)
 
Snubber Mark No.Piping S stem Accessible or Inaccessible (A or I)Especially High Padiation**
Table 3.13-1 (Continued)
Difficult to Zone Remove PS-2 PS-4 PS-5 FS-6 PS-0 PS-'9 PS-10 PS-11 PRZR Safety 6 Relief Valve PRZR Safety S Relief Valve PRZR Safety S Relief Valve PRZR Safety PR R Safety Relic f Valve F Relief Valve PRZR Safety&Relief Valve PRZR Safety 6 Relief Valve PRZR Safety 5 Relief Valve Yes Yes Yes Yes Yes Yes Yes No No No No No No No No I ,Snubbers may be added to or removed from safety related systems without prior License Amendment to Table 3.13-1 provided that a proposed revision to Table 3.13-1 is included~with the next License Amendment request.I ,Modifications to this table due to changes in high radiation areas (during shutdown)shall be submitted to the NRC as part of the next License Amendment request.
Sachet Related Shock Suppressors   (Snubbers)
Attachment B f The proposed change reflects changes made to piping systems at.Ginna as a result of recent analyses.One hydraulic shock suppressor was added to the steam supply piping for the turbine driven auxiliary feedwater pump.Eight hydraulic shock suppressors were added to the pressurizer safe ty and relief piping.As a result of our seismic upgrade program, four existing hydraulic shock suppressors are being replaced with mechanical units.The seismic upgrade program has been described in previous letters to the URC.Decause of the changes which will result from our seismic upgrade program, the footnote to Table 3.13-1 deal.ing with snubber addition has been revised to permit removal of snubbers without prior license amendment.
Accessible or                          Especially Inaccessible        Hiqh Radiation** Difficult to Snubber. Mark No. Pi inq System           (A or I)                 Zone FN-03;           "8" Feedwater                                        No              '..Jo I
Such a change is necessary in order to permit timely implementation of the seismic upgrade program.Changes would only be made following appropriate analysis.Changes to the Technical Specification requirements for snubbers were requested by letter dated starch 23, 1981 from Darrell Eisenhut.A separate change request will be prepared which responds to the request.}}
AFN-1 0         "8" Aux. Feedwa ter                                 bJo            No AF!'-1 3        "B" Aux. Feedwater                                   No             bJo SbJB-265         Stm to TD Aux. Feedwater                           No HG-22           "A" Hain Steam                                       No             No MS-8             "B" Main Steam                                       No             Yes b1S-146 (Top)   "8" blain Steam                                                      No MS-146 (Bottom) "8" Main St.earn                                     No             No
 
Table 3.13-1 (Continued)
Safety Related Shock   Su pressors (Snubbers)
Accessible or                          Especially Inaccessible        High Radiation** Difficult to
          'E" Snubber Hark No.     Pinin     S stem         (A or I)               Zone           Remove HG-147 -.
t1ain Steam                                     No
: 4)                  "E" Haz.n Steam HS-148 >
No              No 4J I
Ch HS-159          "E" Hain Steam                                       No HS-160          "E" Hain Steam                                                         No H-1             PRZR  Relief                                          Yes I'-2               PR?R  Belief                                          Yes H-3             PRZR Pe 1 ie f                                        Yes              No 0
H-4             PRZR  Relief                                          Yes H 5     I,       PPZR Relief                                         Yes             No H-6             PRZR  Relief                                          Yes H-7             PRZR  Relief                                          Yes              No El-8             PPZR Relief                                         Yes K
 
Table 3.13-1 (Continued)
Safet   Related Shock Suppressors   (Snubbers)
Accessible or                          Especially Inaccessible        High Padiation** Difficult to Snubber Mark No.       Piping S stem         (A or I)                 Zone           Remove PS-2       PRZR Safety 6 Relief Valve                             Yes              No PS-4        PRZR Safety S Relief Valve                                               No PS-5        PRZR Safety S Relief Valve                             Yes              No FS-6        PRZR Safety   Relic f Valve                            Yes              No PS-0        PR R Safety F Relief Valve                             Yes              No PS-'9      PRZR Safety & Relief Valve                             Yes              No PS-10      PRZR Safety 6 Relief Valve                             Yes              No PS-11      PRZR Safety 5 Relief Valve                             Yes             No
      ,Snubbers may be added to or removed from safety related systems without prior License I
Amendment to Table 3.13-1 provided that a proposed revision to Table 3.13-1 is included
      ~with the next License Amendment request.
I
      ,Modifications to this table due to changes in high radiation areas (during shutdown) shall be submitted to the NRC as part of the next License Amendment request.
 
Attachment B f
The proposed change reflects changes made to piping systems at. Ginna as a result of recent analyses. One hydraulic shock suppressor was added to   the steam supply piping for the turbine driven auxiliary feedwater pump. Eight hydraulic shock suppressors were added to the pressurizer safe ty and relief piping. As a result of our seismic upgrade program, four existing hydraulic shock suppressors are being replaced with mechanical units.
The seismic upgrade program has been described in previous letters to the URC.
Decause of the changes which will result from our seismic upgrade program, the footnote to Table 3.13-1 deal.ing with snubber addition has been revised to permit removal of snubbers without prior license amendment. Such a change is necessary in order to permit timely implementation of the seismic upgrade program. Changes would only be made following appropriate analysis.
Changes to the Technical Specification requirements for snubbers were requested   by letter dated starch 23, 1981 from Darrell Eisenhut. A separate     change request will be prepared which responds to the request.}}

Latest revision as of 09:23, 29 October 2019

Proposed Revision to App a Tech Spec Table 3.13.1 Re Hydraulic Shock Suppressors
ML17311A010
Person / Time
Site: Ginna Constellation icon.png
Issue date: 05/26/1981
From:
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17258B068 List:
References
NUDOCS 8106010329
Download: ML17311A010 (6)


Text

Attachment A Remove Technical Specification pages 3.13-4 through 3.13-6.

Xnsert attached Technical Specification pages 3.13-4 through 3.13-7.

.abl.e 3.13-l {Continued)

Safety Related Shock Sluppressors (Snubbers)

Accessibl.e or Hspecia11y Inaccessible Elijah Radiation** Aif ficult to Snubber Nark Ho. (A or I) Zone Remove

\

APl'7-25 II A II Aux. Feedwater No AP'">-~6 Aux. Peedwater Uo No l

AFll ~7 Aux. Peedwater No No AFh'-20 Aux. Feedwater APN-29 "A",Aux. Feedwater No No AFN-31 IIAII Aux. Feedwater Uo No AP<'1-49'I "A" Aux. Feedwater No Ho F01-30 "B" Feedwater No No I

FU-80 "8" Peedwater No No FN-81 "8" Peedwater No No "B" Peedwater

't FW-82 No I

Table 3.13-1 (Continued)

Sachet Related Shock Suppressors (Snubbers)

Accessible or Especially Inaccessible Hiqh Radiation** Difficult to Snubber. Mark No. Pi inq System (A or I) Zone FN-03; "8" Feedwater No '..Jo I

AFN-1 0 "8" Aux. Feedwa ter bJo No AF!'-1 3 "B" Aux. Feedwater No bJo SbJB-265 Stm to TD Aux. Feedwater No HG-22 "A" Hain Steam No No MS-8 "B" Main Steam No Yes b1S-146 (Top) "8" blain Steam No MS-146 (Bottom) "8" Main St.earn No No

Table 3.13-1 (Continued)

Safety Related Shock Su pressors (Snubbers)

Accessible or Especially Inaccessible High Radiation** Difficult to

'E" Snubber Hark No. Pinin S stem (A or I) Zone Remove HG-147 -.

t1ain Steam No

4) "E" Haz.n Steam HS-148 >

No No 4J I

Ch HS-159 "E" Hain Steam No HS-160 "E" Hain Steam No H-1 PRZR Relief Yes I'-2 PR?R Belief Yes H-3 PRZR Pe 1 ie f Yes No 0

H-4 PRZR Relief Yes H 5 I, PPZR Relief Yes No H-6 PRZR Relief Yes H-7 PRZR Relief Yes No El-8 PPZR Relief Yes K

Table 3.13-1 (Continued)

Safet Related Shock Suppressors (Snubbers)

Accessible or Especially Inaccessible High Padiation** Difficult to Snubber Mark No. Piping S stem (A or I) Zone Remove PS-2 PRZR Safety 6 Relief Valve Yes No PS-4 PRZR Safety S Relief Valve No PS-5 PRZR Safety S Relief Valve Yes No FS-6 PRZR Safety Relic f Valve Yes No PS-0 PR R Safety F Relief Valve Yes No PS-'9 PRZR Safety & Relief Valve Yes No PS-10 PRZR Safety 6 Relief Valve Yes No PS-11 PRZR Safety 5 Relief Valve Yes No

,Snubbers may be added to or removed from safety related systems without prior License I

Amendment to Table 3.13-1 provided that a proposed revision to Table 3.13-1 is included

~with the next License Amendment request.

I

,Modifications to this table due to changes in high radiation areas (during shutdown) shall be submitted to the NRC as part of the next License Amendment request.

Attachment B f

The proposed change reflects changes made to piping systems at. Ginna as a result of recent analyses. One hydraulic shock suppressor was added to the steam supply piping for the turbine driven auxiliary feedwater pump. Eight hydraulic shock suppressors were added to the pressurizer safe ty and relief piping. As a result of our seismic upgrade program, four existing hydraulic shock suppressors are being replaced with mechanical units.

The seismic upgrade program has been described in previous letters to the URC.

Decause of the changes which will result from our seismic upgrade program, the footnote to Table 3.13-1 deal.ing with snubber addition has been revised to permit removal of snubbers without prior license amendment. Such a change is necessary in order to permit timely implementation of the seismic upgrade program. Changes would only be made following appropriate analysis.