1 E0P: TITLE:

LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11

.ECA-0.2 REQUIRED PAGE 1 of 9 O

(_f ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER b e

RESPONSIBLE)hANAGER j JR -H4f EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

U 9812210279 981214 I t-

' PDR ADOCK 05000244, 1 P PDR Q _ _

. .. ~ - . . . - _ . . - . -

. - . . . . . . . - _ . . ~ . . ~ - . ~ . - . ~ . . . - . . . .

4 l , E0P: TITLE:

l LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0.2 REQUIRED i

PAGE 2 of 9 IO lJ A. PURPOSE - This procedure provides actions to use engineered safeguards systems to recover plant conditions following restoration of AC emergency power.

B. ENTRY CONDITIONS / SYMPTOMS

1. ENTRY CONDITIONS - This procedure is entered from:

l a. ECA-0.0, LOSS OF ALL AC POWER, when AC emergency l power is restored and SI is required.

l b. ECA-0.1, LOSS OF ALL AC POWER RECOVERY WITHOUT SI REQUIRED, if SI is required.

I h

l O

l l

l

E0P: TITLE:

LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0*2 4

REQUIRED TAGE 3 of 9 G

V -

STEP -

ACTION / EXPECTED RESPONSE RESPONSENOTUBTi.1NEDl NOTE: o CSFSTs should be monitored for information only. FR procedures

should not be implemented prior to completion of Step 10.

l o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+05 R/hr.

1 Reset SI 2 Check RCP CCW Isolation Status:

a. CCW pumps - BOTH PUMPS OFF a. Go to Step 3.

l b. RCP CCW return valves - CLOSED b. Manually close valves as l necessary:

i e MOV-759A i' . MOV-759B o RCP CCW thermal barrier j outlet valves l

l -OR-l' o RCP CCW supply valves e MOV-749A  ;

e MOV-749B

i i i 3 Check RWST Level - GREATER Co to ES-1.3. TRANSFEP. TO COLD LEG THAN 28% RECIRCULATION, Step 1.

l l

l l

I i

l a

LOP: 'ilI LE:

LOSS OF ALL AC' POWER RECOVERY WITH SI REV: 11 ECA-0.2 4

REQUIRED PAGE 4 of 9 O -

STEP -

ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED F_QIB: SI actuation to establish safeguards valve alignment is not recommended.

4 Manually Align SI And RHR Pumps To Establish SI Injection:

a. SI pump suction valves from RWST a. Ensure at least one SI pump

- OPEN suction valve from RWST open.

. MOV-825A e MOV-825A

= MOV-825B e MOV-825B

b. Verify SI pump C discharge b. Manually open valves as valves - OPEN necessary.

. MOV-871A e MOV-871B

c. RHR pump discharge to Rx vessel c. Ensure at least one deluge valve O

deluge - OPEN open.

. MOV-852A e MOV-852A e MOV-852B e MOV-852B O _

E0P: TITLE:

LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0.2 REQUIRED PAGE 5 of 9 p .

V STEP -

ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION THE LOADS PLACED ON THE ENERGIZED AC EMERGENCY BUS SHOULD NOT EXCEED THE CAPACITY OF THE POWER SOURCE.

5 Manually Load Following -

Safeguards Equipment On AC Emergency Bus: 1

a. Start all SI pumps a. Perform the following:
1) Start available SI pumps.
2) H SI pump A or B M available. THEN verify SI pump C aligned as follows:

o H SI pump A M available. THEN ensure MOV-871B closed, o H SI pump B M available. THEN ensure MOV-871A closed,

b. Check RCS pressure: b. Manually start both RHR pumps and go to Step Sd.

o Pressure - GREATER THAN 250 psig [465 psig adverse CNMT) o Pressure - STABLE OR INCREASING

c. Place RHR pump switches in AUTO
d. Start all available CNMT RECIRC fans

-a _ L z_ - . . . . ._ , A -...A __ ._.A ., .m.R _-. h E0P: TITLE: l LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 j 4

ECA-0.2 REQUIRED l PAGE 6 of 9

('~\ ,

I (_ /

STEP --

ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED i

l CAUTION l

o IF CST LEVEL DECREASES TO LESS TRAN 5 FEET. THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.I. ALTERNATE WATER SUPPLY TO AFW PUMPS).

I o IF S/G NR LEVEL DECREASES TO LESS THAN 5% [25% ADVERSE CNMT] AND FEED FLOW

' l IS LESS THAN 200 GPM, THEN THE MDAFW PUMPS SHOULD BE MANUALLY LOADED ON AC l EMERGENCY BUS TO SUPPLY WATER TO THE S/G(S).

4 l

NOTE: o If MDAFW pump operation is not required, pump switches should be l maintained in PULL-STOP to prevent automatic start.

o TDAFW pump flow control valves fail open on loss of IA.

  • 6 Monitor Intact S/G Levels:

fx i() a. Narrow range level - GREATER THAN 5% [25% adverse CNMT]

a. Maintain total feed flow greater than 200 gpm until narrow range level greater than 5% [25%

adverse CNMT] in at least one S/G.

IE feed flow less than 200 gpm, THEN perform the following:

1) Verify MDAFW pump discharge valve to intact S/G(s) open.

. S/G A, MOV-4007 e S/G B, MOV-4008

2) Manually start MDAFW pumps as necessary (228 KW).
b. Control feed flow to maintain narrow range level between 17%

l [25% adverse CNMT] and 50%

,T U

f i

LOP: TITLE:

LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11

. ECA-0.2 REQUIRED PAGE 7 of 9 b'i l O l STEP -

ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 1

l l 7 Verify CI And CVI:

1

a. CI and CVI annunciators - LIT a. Depress manual CI pushbutton.

ISOIATION l

  • Annunciator A-25. CONTAINMENT l VENTILATION ISOLATION l i
b. Verify CI and CVI valve status b. Manually close CI and CVI l
lights - BRIGHT valves. IE valves can EI be '

verified closed by MCB indication THEN dispatch A0 to locally close valves (Refer to Attachment CI/CVI).

c. CNMT RECIRC fan coolers SW c. Dispatch A0 to locally fail apen outlet valve status lights - valves.

BRIGHT i e A0V-4561 e A0V-4562 i

1 b[h I

LOP: ilTLE:

LOSS OF ALL AC POWER RECOVERY WITH SI RW: 11 ECA-0.2 4

REQUIRED PAGE 8 of 9

.O V

STEP -

ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 8 Verify CNMT Spray Not IE CNMT pressure is less than 28 Required: psig. THEN perform the following:

o Annunciator A-27. CNMT SPRAY - a. Reset CNMT spray.

EXTINGUISHED

b. Place CNMT spray pump dinharge o CNMT pressure - LESS THAN 28 PSIG valve switches to CLOSE to deenergize open contactor.

IF NOT, THEN perform the following:

a. Depress manual CNMT spray pushbuttons (2 of 2).
b. Ensure CNMT spray pump discharge valves open.

o CNMT spray pump A:

  • MOV-860A e MOV-860B o CNMT spray pump B:
  • MOV-8600 e MOV-860D c'. Ensure NaOH tank outlet valves open.
d. Start both CNMT spray pumps.
e. Go to step 10.

O O

(

. . - . _ . - . . . . _ . ~ . . - . _ - _ - . . . . . . - . . . _ _ . . .

se

E0P
TITLE:

LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0.2 i REQUIRED PAGE 9 of 9 0 -

STEP -

ACTION / EXPECTED RESPONSE -<

RESPONSE NOT OBTAINED 9 Place CNMT Spray Pumps In AUTO 10 Check RCP Seal Injection Locally close valves before Needle Valves - CLOSED starting charging pump.

e V-300A

= V-300B HQI_E: FR procedures may now be implemented as necessary.

11 Go to E-1, LOSS OF REACTOR OR SECONDAR'I COOLANT, Step 1

-END-O i