E0P:

TITLE:

REV: 5

. T.

FR-Z.1, RESPONSE TO HIGH CONTAINMENT PRESSURE PAGE 1 of 6 ROCHESTER GAS AND ELECTRIC CORPORATION l

GINNA STATION l

CONTROLLED COPY NUMBER 1

i

.h i

m D

RESPONSIBLE} MANAGER I

/2+/4C EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:

9812210291 981214 7 PDR ADOCK 05000244

?l PDRf P

E0P:

TITLE:

REV: 5 9

FR-Z.1 RESPONSE TO HIGH CONTAINMENT PRESSURE PAGE 2 of 6 AU A.

PURPOSE - This procedure provides actions to respond to a high CNMT pressure.

B.

ENTRY CONDITIONS / SYMPTOMS 1.

ENTRY CONDITIONS - This procedure is entered from:

a.

F-0.5, CONTAINMENT Critical Safety Function Status Tree, on a RED or ORANGE condition.

n tv/

I t

_. - ~. -.. -. -

E0P:

TITLE:

REV: 5 1

}

FR-Z.1 RESPONSE TO HIGH CONTAINMENT PRESSURE PAGE 3 of 6 eG 1

e ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED STEP I

1 Verify All CI And CVI Valve H flow path M required. THEN Status Lights - BRIGHT manually close CI and CVI valves.

E valves can M be verified closed by MCB indication. THEN dispatch A0 to locally close valves. (Refer to Attachment CI/CVI).

CAUTION IF ECA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION, IS IN EFFECT THEN CNMT SPRAY SHOULD BE OPERATED AS DIRECTED IN ECA-1.1, RATHER THAN STEP 2 BELOW.

2 Verify CNMT Spray Actuated:

a. Verify RWST outlet to SI and
a. E in RHR recirculation mode, b)

CNMT spray pumps - OPEN THEN perform the following:

%J e MOV-896A

1) Operate SI pumps and one CNMT

. MOV-896B spray pump as directed in ES-1.3 TRANSFER TO COLD LEG RECIRCULATION, Step 14.

2) Go to Step 3.

b Verify CNMT spray pumps RUNNING

b. Manually start pumps,
c. Verify CNMT spray NaOH addition
c. Ensure at least one valve open.

valves - OPEN

. HCV-836A e HCV-836B

d. Verify CNMT spray pump discharge
d. Ensure at least one in each set valves - OPEN open.

. MOV-860A

  • MOV-860A or MOV-860B l

. MOV-860B e MOV-860C or MOV-860D

. MOV-860C

. MOV-860D D0 L

m...

~

E0P:

TITLE:

REV: 5 4

FR-Z.1 RESPONSE TO HIGH CONTAINMENT PRESSURE k

PAGE 4 of 6 i

")

1l O ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED STEP I..

3 Verify CNMT RECIRC Fans i

Running:

1

a. All fans - RUNNING
a. Manually start fans.

I

b. Charcoal filter dampers green
b. Dispatch personnel to relay room i

status lights - RXTINGUISHED with relay rack key to locally open dampers by pushing in trip 4

j relay plungers.

1 4

. AUX RELAY RACK RA-2 for fan A

= AUX RELAY RACK RA-3 for fan C 4 Verify MSIVs - CLOSED Manually close valves.

4 4

O

E0P:

TITLE:

REV: 5 FR-Z.1 RESPONSE TO HIGH CONTAINMENT PRESSURE g

PAGE 5 of 6

/'7T V

ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED STEP CAUTION AT LEAST ONE S/G SHALL BE MAINTAINED AVAILABLE FOR RCS C00LDOWN.

o o IF BOTH S/GS ARE FAULTED THEN AT LEAST 50 GPM FEED FLOW SHOULD BE MAINTAINED TO EACH S/G.

5 Check If S/G Secondary Side Isolate feed flow to faulted S/G:

Is Intact:

a. Ensure faulted S/G MDAFW pump o Pressure in both S/Gs - STABLE discharge valve closed.

OR INCREASING S/G A, MOV-4007 e

o Pressure in both S/Gs - GREATER S/G B, MOV-4008 e

TRAN 110 PSIG

b. Ensure faulted S/G TDAFW flow control valve closed.

l)

S/G A. A0V-4297 S/G B, A0V-4298

c. Ensure faulted S/G MFW regulating valve and bypass valve closed, S/G A HCV-466 and HCV-480 e

. S/G B, HCV-476 and HCV-481

d. Ensure MFW pump discharge valves closed.

If valves can HOI be closed. THEN dispatch A0 to locally close valves as necessary to isolate flow.

O

. _ _. ~. _.... _ _.... _ _ _. _

E0P:

TITLE:

i REV: 5 FR-Z.1 RESPONSE TO HIGH CONTAINMENT PRESSURE e4 PAGE 6 of 6

~

j ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED STEP 1

(

6 Return To Procedure And Step In Effect

-END-i i