ML19200A179: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:/RA/}}
{{#Wiki_filter:OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 July 19, 2019 Dr. Ronald J. Land Site Manager Framatome Inc.
2101 Horn Rapids Road Richland, WA 99354-0130
 
==SUBJECT:==
FRAMATOME, INC., U.S. NUCLEAR REGULATORY COMMISSION INSPECTION REPORT 70-1257/2019-401
 
==Dear Dr. Land:==
 
The Nuclear Regulatory Commission (NRC) conducted a routine safeguards inspection, at the Framatome Inc. facility, in Richland, Washington, on June 17 - 20, 2019. The purpose of the inspection was to evaluate activities authorized by your license were conducted safely and in accordance with Nuclear Regulatory Commission (NRC) regulatory requirements. The enclosed report presents the results of this inspection which were discussed with members of your staff during an exit meeting held at the conclusion of the onsite inspection on June 20, 2019.
This inspection examined activities conducted under your license as they relate to public health and safety, the common defense and security, and to confirm compliance with the Commissions rules, regulations, and the conditions of your license. Areas examined during this inspection included management structure, item control, measurement systems and control, physical inventory, resolution, assessment, and recordkeeping. Within these areas, the inspection consisted of selective examination of procedures and representative records, interviews with personnel, and observations of activities in progress. No violations of more than minor significance were identified during this inspection.
The enclosed inspection report contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosures will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
The enclosure contains Sensitive Unclassified Non Safeguards Information (Security-Related Information). Upon separation, this cover letter is DECONTROLLED.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
 
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION R. Land 2
Should you have any questions concerning this report, please contact Mr. Thomas Grice at 404-997-4477, or via e-mail to Thomas.Grice@nrc.gov.
Sincerely,
                                                  /RA/
Eric Michel, Chief Projects Branch 2 Division of Fuel Facility Inspection Docket No. 70-1257 License No. SNM-1227
 
==Enclosure:==
 
NRC Inspection Report 70-1257/2019-401 w/Supplemental Information cc:
Timothy J. Tate, Manager Environmental, Health, Safety & Licensing Framatome Inc.
2101 Horn Rapids Road Richland, Washington 99354 Calvin D. Manning, Manager Licensing and Compliance Framatome Inc.
2101 Horn Rapids Road Richland, Washington 99354 Michael Wilbricht, Specialist MC&A Safeguards Framatome Inc.
2101 Horn Rapids Road Richland, Washington 99352 OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
 
ML19200A179 OFFICE            RII: DFFI  RII: DFFI  RII: DFFI NAME              TGrice      DAnderson  RGibson DATE              7/17/2019  7/18/2019  7/18/2019}}

Latest revision as of 16:26, 19 October 2019

Framatome, Inc., U.S. Nuclear Regulatory Commission Inspection Report 07001257/2019401
ML19200A179
Person / Time
Site: Framatome ANP Richland
Issue date: 07/19/2019
From: Eric Michel
NRC/RGN-II/DFFI
To: Land R
Framatome
Geanette D
References
IR 2019401
Download: ML19200A179 (3)


Text

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 245 PEACHTREE CENTER AVENUE NE, SUITE 1200 ATLANTA, GEORGIA 30303-1257 July 19, 2019 Dr. Ronald J. Land Site Manager Framatome Inc.

2101 Horn Rapids Road Richland, WA 99354-0130

SUBJECT:

FRAMATOME, INC., U.S. NUCLEAR REGULATORY COMMISSION INSPECTION REPORT 70-1257/2019-401

Dear Dr. Land:

The Nuclear Regulatory Commission (NRC) conducted a routine safeguards inspection, at the Framatome Inc. facility, in Richland, Washington, on June 17 - 20, 2019. The purpose of the inspection was to evaluate activities authorized by your license were conducted safely and in accordance with Nuclear Regulatory Commission (NRC) regulatory requirements. The enclosed report presents the results of this inspection which were discussed with members of your staff during an exit meeting held at the conclusion of the onsite inspection on June 20, 2019.

This inspection examined activities conducted under your license as they relate to public health and safety, the common defense and security, and to confirm compliance with the Commissions rules, regulations, and the conditions of your license. Areas examined during this inspection included management structure, item control, measurement systems and control, physical inventory, resolution, assessment, and recordkeeping. Within these areas, the inspection consisted of selective examination of procedures and representative records, interviews with personnel, and observations of activities in progress. No violations of more than minor significance were identified during this inspection.

The enclosed inspection report contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosures will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

The enclosure contains Sensitive Unclassified Non Safeguards Information (Security-Related Information). Upon separation, this cover letter is DECONTROLLED.

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION R. Land 2

Should you have any questions concerning this report, please contact Mr. Thomas Grice at 404-997-4477, or via e-mail to Thomas.Grice@nrc.gov.

Sincerely,

/RA/

Eric Michel, Chief Projects Branch 2 Division of Fuel Facility Inspection Docket No. 70-1257 License No. SNM-1227

Enclosure:

NRC Inspection Report 70-1257/2019-401 w/Supplemental Information cc:

Timothy J. Tate, Manager Environmental, Health, Safety & Licensing Framatome Inc.

2101 Horn Rapids Road Richland, Washington 99354 Calvin D. Manning, Manager Licensing and Compliance Framatome Inc.

2101 Horn Rapids Road Richland, Washington 99354 Michael Wilbricht, Specialist MC&A Safeguards Framatome Inc.

2101 Horn Rapids Road Richland, Washington 99352 OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION

ML19200A179 OFFICE RII: DFFI RII: DFFI RII: DFFI NAME TGrice DAnderson RGibson DATE 7/17/2019 7/18/2019 7/18/2019