ML20205S126: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 14: Line 14:
| document type = INTERNAL OR EXTERNAL MEMORANDUM, MEMORANDUMS-CORRESPONDENCE
| document type = INTERNAL OR EXTERNAL MEMORANDUM, MEMORANDUMS-CORRESPONDENCE
| page count = 1
| page count = 1
| project = TAC:61403, TAC:61404
| stage = Other
}}
}}



Latest revision as of 17:27, 6 December 2021

Requests Assistance in Conducting Reviews of Encl 860304 Submittals Requesting Relief from Section XI Test Requirements.Salp Input Also Requested
ML20205S126
Person / Time
Site: Salem  PSEG icon.png
Issue date: 05/28/1986
From: Novak T
Office of Nuclear Reactor Regulation
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20205S128 List:
References
TAC-61403, TAC-61404, NUDOCS 8606110503
Download: ML20205S126 (1)


Text

mu 4  % UNITED STATES

[ \[ q 'g _ NUCLEAR REGULATORY COMMISSION WASHING TON. D. C. 20555 j[

.;4,y[j/

g 3oka

%, *

  • J c

May 28, 1986

' MEMORANDUM FOR:

hard W. Starostecki, Director Division of Reactor Projects Region I

'FROM:

Thomas M. Novak, Acting Director Division of Licensing Office of Nuclear Reactor Regulation

SUBJECT:

LICENSING ACTION REVIEW FOR SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2 Your assistance is requested in conducting reviews of the enclosed submittals from Public Service Electric and Gas Company dated March 4, 1986. Your review of the. submittal is requested for the subject Relief from Section XI Test Requirements. -The product expected as a result of your review should consist of a written evaluation.

In accordance with NRR Office Letter No. 44, the safety evaluation performed by a technical division shall have a SALP input provided. For purposes of this review, the Regional personnel involved are considered part of the technical division. Therefore, we are requesting that your forwarding memorandum contain a SALP input for the safety evaluation performed.

WorkforthelereviewshasbeendiscussedwithD.Haverkampofyourstaff.

The The TAC numbers are 61403 for Salem Urit I and 61404 for Salem Unit 2.

requested completion date is June 30, 1986 for the review. Contact with the licensee on this review effort or any significant additional information deemed necessary should be obtained through the NRR Project Manager or with his concurrence. The Project Manager for this plant is Donald Fischer and he can be reached at 492-7354.

Thomas M. Novak, Acting Director Division of PWR Licensing-A Office of Nuclear Reactor Regulation

Enclosures:

As stated I

%afoucTo3 I q.

.ys*

4 RECg;y ISss ,,,, gg' Rec,g,,, ,

l'// 3 29 1 .

. i