Arkansas Nuclear One - Administrative Senices
;-                                      ENTERGY OPS, INC 1448 SR 333 Russellville, AR 72801 Document Control
        ,                                    11/2498 Controlled Document Transmittal COPYHOLDER NO:                102 TO:                          NRC DOCUMENT CONTROL WASIIINGTON, D.C.
DOCUMENT TITLE:              UNIT II TECIINICAL REQUIREMENT MANUAL REV/ AMEND /CHG NO: APPROVED REV 01
 
==SUBJECT:==
EFFECTIVE DATE 11/23/98 f this box is checked, please sign, date, and return transmittal in    O envelope provided.                                                        /
ANO-1 Docket 50-313                        A
                                                                                <%v/
7ANO-2 Docket 50-368 Signature                                  Date
                                          ~
9812020128 981124 PDR      ADOCK0500g8 I
 
I
    ,                                                                                                        l ATTACHMENT TO REVISION NO. "1" i~                                                      FOR ANO- 2 i
TECHNICAL REOUIREMENTS MANUAL (TRhD l
j-.
Revise the following pages of the TRM for ANO-2 with the attached pages. The revised pages
;              are identified by Revision number and contain vertical lines indicating the area of change.
i l                              INSERT PAGES                                REMOVE PAGES i                                  3.3-8                                          3.3-8                  i
)                                                                                                          i i
J l
i lO
:                                                                                                          l i
0 I
1                                                                                                            l l
1 l
i l
O i
I
                                                                                                            ]
 
4      .
INSTRUMENTATION
!'            3/4.3.4 TURBINE OVERSPEED PROTECTION LIMITING CONDITION FOR OPERATION 3.3.4.1 -      At least one turt>ine overspeed protection system shall be OPERABLE.
4 f
APPLICABILITY: MODES 1,2 and 3.
ACTION:
i 2
: a. With one stop valve and/or one control valve inoperable, and/or one reheat stop j'
~
valve and/or one intercept valve inoperable, restore the inoperable valve (s) to OPERABLE status within 72 hours, or close the inoperable valve (s) or isolate the                i
[                            turbine from the steam supply within the next 12 hours.
t i                      b. With the above required turt>ine overspeed pret.ction system otherwise inoperable,                  j i                            within 24 hours isolate the turbbe from the steam supply.                                          '
t                                                                                                                          l j              SURVEILLANCE REQUIREMENTS                                                                                      j
,            4.3.4.1.1 The provisions of Technical Specificabon 4.0.4 are not applicable.
j                                                                                                                            ;
4.3.4.1.2 The above required turt>ine overspeed protection system shall be demonstrated j              OPERABLE:
i
: a. At least once per 92 days
* by direct observation of the movement of each of the                l ;
j                            foliowing valves through at least one complete cycle from the running position:                l,
!                            1. Four high pressure turbine stop valves.                                                      '
4                                                                                                                              i
: 2. Four high pressure turbine control valves.                                                  .
l 1
l                            3. Four low pressure turbine reheat stop and intercept valves.                                l j                      b. At least once per 18 months by performance of a CHANNEL CAUBRATION on the i                            turbine overspeed protection systems.                                                            !
l l                      c. At lemt once per 40 months by disassembling at least one of each of the above
;                            valves and performing a visual and surface inspechon of valve seats, disks and
;                            stems and verifying no unacceptable flaws or corrosion.
l                                                                                                                                ,
i i
!                                                                                                                              l 1
i i
l m The 92 day frequency may be extended on a case by case basis for the high pressure                              ,
    .        turbine control valves with an approved ER evaluation that has been evalua'.sd under 50.59.                      l ANO-2 TRM                                        3.3-8                                          Rev. 1          1 i
j
          ,}}

Latest revision as of 05:31, 13 November 2020

Rev 1 to Unit 2 Technical Requirements Manual
ML20196C976
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 11/24/1998
From:
ENTERGY OPERATIONS, INC.
To:
References
PROC-981124, NUDOCS 9812020128
Download: ML20196C976 (3)


Text

._

Arkansas Nuclear One - Administrative Senices

- ENTERGY OPS, INC 1448 SR 333 Russellville, AR 72801 Document Control

, 11/2498 Controlled Document Transmittal COPYHOLDER NO: 102 TO: NRC DOCUMENT CONTROL WASIIINGTON, D.C.

DOCUMENT TITLE: UNIT II TECIINICAL REQUIREMENT MANUAL REV/ AMEND /CHG NO: APPROVED REV 01

SUBJECT:

EFFECTIVE DATE 11/23/98 f this box is checked, please sign, date, and return transmittal in O envelope provided. /

ANO-1 Docket 50-313 A

<%v/

7ANO-2 Docket 50-368 Signature Date

~

9812020128 981124 PDR ADOCK0500g8 I

I

, l ATTACHMENT TO REVISION NO. "1" i~ FOR ANO- 2 i

TECHNICAL REOUIREMENTS MANUAL (TRhD l

j-.

Revise the following pages of the TRM for ANO-2 with the attached pages. The revised pages

are identified by Revision number and contain vertical lines indicating the area of change.

i l INSERT PAGES REMOVE PAGES i 3.3-8 3.3-8 i

) i i

J l

i lO

l i

0 I

1 l l

1 l

i l

O i

I

]

4 .

INSTRUMENTATION

!' 3/4.3.4 TURBINE OVERSPEED PROTECTION LIMITING CONDITION FOR OPERATION 3.3.4.1 - At least one turt>ine overspeed protection system shall be OPERABLE.

4 f

APPLICABILITY: MODES 1,2 and 3.

ACTION:

i 2

a. With one stop valve and/or one control valve inoperable, and/or one reheat stop j'

~

valve and/or one intercept valve inoperable, restore the inoperable valve (s) to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, or close the inoperable valve (s) or isolate the i

[ turbine from the steam supply within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

t i b. With the above required turt>ine overspeed pret.ction system otherwise inoperable, j i within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> isolate the turbbe from the steam supply. '

t l j SURVEILLANCE REQUIREMENTS j

, 4.3.4.1.1 The provisions of Technical Specificabon 4.0.4 are not applicable.

j  ;

4.3.4.1.2 The above required turt>ine overspeed protection system shall be demonstrated j OPERABLE:

i

a. At least once per 92 days
  • by direct observation of the movement of each of the l ;

j foliowing valves through at least one complete cycle from the running position: l,

! 1. Four high pressure turbine stop valves. '

4 i

2. Four high pressure turbine control valves. .

l 1

l 3. Four low pressure turbine reheat stop and intercept valves. l j b. At least once per 18 months by performance of a CHANNEL CAUBRATION on the i turbine overspeed protection systems.  !

l l c. At lemt once per 40 months by disassembling at least one of each of the above

valves and performing a visual and surface inspechon of valve seats, disks and
stems and verifying no unacceptable flaws or corrosion.

l ,

i i

! l 1

i i

l m The 92 day frequency may be extended on a case by case basis for the high pressure ,

. turbine control valves with an approved ER evaluation that has been evalua'.sd under 50.59. l ANO-2 TRM 3.3-8 Rev. 1 1 i