consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201
consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201
Line 36: Line 35:
f.
f.


...
2 These dr_awings have been sent to Mr Richard Silver of. the NRC.
2 These dr_awings have been sent to Mr Richard Silver of. the NRC.
David P Hoffman (Signed)
David P Hoffman (Signed)
David P Hoffman Nuclear Licensing Administrator CC  JGKeppler, USNRC .}}
David P Hoffman Nuclear Licensing Administrator CC  JGKeppler, USNRC .}}

Revision as of 13:40, 3 February 2020

Forwards Drawings Per NRC 791012 Request Re Safety Sys motor-operated Valve Control Circuits.Drawings Available in Central Files Only
ML18044A635
Person / Time
Site: Palisades Entergy icon.png
Issue date: 03/03/1980
From: Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Ziemann D
Office of Nuclear Reactor Regulation
Shared Package
ML18044A636 List:
References
TASK-03-10.A, TASK-06-07.F, TASK-3-10.A, TASK-6-7.F, TASK-RR NUDOCS 8003130577
Download: ML18044A635 (2)


Text

-........ 'I f

  • ----_,, --**~ *...

~---*

consumers Power company General Offices: 212 West Michigan Avenue, Jackson, Michigan 49201

  • Area Code 517 788-0550 March 3, 1980 Director, Nuclear Reactor Regulation Att Mr Dennis L Ziemann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - SEP TOPIC III-10.A -

THERMAL OVERLOAD PROTECTION Consumers Power Company was requested by NRC letter dated October 12, 1979 (thermal overload protection) to supply drawings for safety system motor-operated valve control circuits. These drawings (listed below) describe the position of the hand switches, limit switches and automatic switches for all the engineered safeguard system valves .

. ...;;,.,:;..

Valve Number DescriEtion Drawing Number MOV-3008 SI Low Pressure E-244, Sheets 1, 2 & 3 .--/

MOV-3010 SI Low Pressure E-244, Sheets 1, 2 &3 MOV-3012 SI Low Pressure E-244, Sheets 1, 2 &3 MOV-3014 SI Low Pressure E-244, Sheets 1, 2 &3 MOV-3007 SI High Pressure E-244, Sheets 1, 2 &3 MOV-3009 SI High Pre.ssure E-244, Sheets 1, 2 &3 MOV-3062 SI High Pressure E-244, Sheets 1, 2 & 3 MOV-3064 SI High Pressure E-244, Sheets 1, 2 & 3 MOV-3011 SI High Pressure E-244, Sheets 1, 2 .& 3 MOV-3013 SI High Pressure E'-244, Sheets 1, 2 &3 MOV-3066 SI High Pressure E-244, Sheets 1, 2 & 3 MOV-3068 SI High Pressure E-244, Sheets 1, 2 & 3 MOV-3072 Charging Ptimp Test Conn E-242, Sheet 2 MOV-3015 Shutdown Cooling E-242, Sheet 3 MOV-3016 Shutdown Cooling E-242, Sheet 3 MOV-3041 SI Tank E-243, Sheets 1 & 121 ~*

MOV-3045 SI Tank ~-243, Sheets 1 & 2 ~

MOV-3049 SI Tank E-243, Sheets 1 & 2~

MOV-3052 SI Tank E-243, Sheets 1 & 2 ~,, (fi*

8 003180

~7 ~~~ ~\~

)

f.

2 These dr_awings have been sent to Mr Richard Silver of. the NRC.

David P Hoffman (Signed)

David P Hoffman Nuclear Licensing Administrator CC JGKeppler, USNRC .