Line 3: Line 3:
| issue date = 08/27/2014
| issue date = 08/27/2014
| title = Interim Report -10CFR 21 Evaluation Regarding Potential Deficiencies in Ensuring Customer Wall Thickness Requirements Were Met
| title = Interim Report -10CFR 21 Evaluation Regarding Potential Deficiencies in Ensuring Customer Wall Thickness Requirements Were Met
| author name = Tuttle D E
| author name = Tuttle D
| author affiliation = Anderson Greenwood Crosby Corp, Pentair Valves And Controls
| author affiliation = Anderson Greenwood Crosby Corp, Pentair Valves And Controls
| addressee name =  
| addressee name =  
Line 15: Line 15:


=Text=
=Text=
{{#Wiki_filter:PE NTAI RDavid TuttleQuality Assurance ManagerPENTAIR VALVES & CONTROLS508-594-4430 (direct)508-594-4249 (fax)David.Tuttle@Pentair.com Mansfield, MA 02048www.pentair.com August 27, 2014VIA REGULAR MAIL:U.S. Nuclear Regulatory Commission Document Control DeskWashington, DC 20555-0001 VIA OVERNIGHT DELIVERY:
{{#Wiki_filter:PE NTAI R                                                                                      David Tuttle Quality Assurance Manager PENTAIR VALVES & CONTROLS 508-594-4430 (direct) 508-594-4249 (fax)
U.S. Nuclear Regulatory Commission 11555 Rockville PikeRockville, MD 20852-2746
David.Tuttle@Pentair.com Mansfield, MA 02048 www.pentair.com August 27, 2014 VIA REGULAR MAIL:
U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 VIA OVERNIGHT DELIVERY:
U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2746


==Subject:==
==Subject:==
Interim Report -10CFR 21 Evaluation Regarding Potential Deficiencies in Ensuring Customer Wall Thickness Requirements were Met.
The purpose of this letter is to close out the NRC report in general conformity to the requirements of 10CFR 21 Part 21.21 (a) (2).
This report is the result of an evaluation of a deviation in components that have been delivered to a nuclear power plant customer.
This report is to close out the subject line to the NRC of the 10CFR 21 evaluation and the results of that evaluation to date. Pentair Valves and Controls US LP, dba Anderson Greenwood Crosby is notifying the NRC of these results as well as the affected licensee.
Required information as per 10CFR Part 21.21 (d)(4) follows:
(i)    Name and Address of the individual or individuals informing the Commission:
David Tuttle Quality Assurance Manager Pentair Valves and Controls US LP, dba Anderson Greenwood Crosby Mansfield Operations 55 Cabot Blvd Mansfield, MA 02048 6/9


Interim Report -10CFR 21 Evaluation Regarding Potential Deficiencies in EnsuringCustomer Wall Thickness Requirements were Met.The purpose of this letter is to close out the NRC report in general conformity to therequirements of 10CFR 21 Part 21.21 (a) (2).This report is the result of an evaluation of a deviation in components that have beendelivered to a nuclear power plant customer.
PENTAIR (ii) Identification of the facility, the activity, or basic component supplied for such facility or such activity within the Unites States which fails to comply or contains a defect.
This report is to close out the subject line to the NRC of the 10CFR 21 evaluation and theresults of that evaluation to date. Pentair Valves and Controls US LP, dba AndersonGreenwood Crosby is notifying the NRC of these results as well as the affected licensee.
Four valves (N900299-00-0001 thru 0004) were delivered to Luminant Energy - Comanche Peak Station that were subsequently returned by the customer in order for the required wall thickness measurements to be performed.
Required information as per 10CFR Part 21.21 (d)(4) follows:(i) Name and Address of the individual or individuals informing the Commission:
(iii) Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.
David TuttleQuality Assurance ManagerPentair Valves and Controls US LP, dba Anderson Greenwood CrosbyMansfield Operations 55 Cabot BlvdMansfield, MA 020486/9 PENTAIR(ii) Identification of the facility, the activity, or basic component supplied for such facilityor such activity within the Unites States which fails to comply or contains a defect.Four valves (N900299-00-0001 thru 0004) were delivered to LuminantEnergy -Comanche Peak Station that were subsequently returned by thecustomer in order for the required wall thickness measurements to beperformed.
Pentair Valves and Controls US LP, dba Anderson Greenwood Crosby Mansfield Operations 55 Cabot Blvd Mansfield, MA 02048 (iv) Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.
(iii) Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.Pentair Valves and Controls US LP, dba Anderson Greenwood CrosbyMansfield Operations 55 Cabot BlvdMansfield, MA 02048(iv) Nature of the defect or failure to comply and the safety hazard which is created orcould be created by such defect or failure to comply.The nature of the failure to comply is that Pentair did not performcustomer required wall thickness measurements on the valve bodies.Pentair requested the subject valves back from Luminant Energy onReturned Goods Authorization 2392 on March 21, 2014. Pentair hasdisassembled the subject valves and has performed the required wallthickness measurements.
The nature of the failure to comply is that Pentair did not perform customer required wall thickness measurements on the valve bodies.
(v) The date on which the information of such defect or failure to comply was obtained.
Pentair requested the subject valves back from Luminant Energy on Returned Goods Authorization 2392 on March 21, 2014. Pentair has disassembled the subject valves and has performed the required wall thickness measurements.
21 March 2014(vi) In the case of a basic component which contains a defect or fails to comply, the numberand location of these components in use at, supplied for, being supplied for, or may besupplied for, manufactured or being manufactured for one or more facilities oractivities subject to the regulations in this Part.See section ii above.(vii) The corrective action which has been, is being, or will be taken; the name of theindividual or organization responsible for the action and the length of time that hasbeen or will be taken to complete the action.Wall thickness measurements have performed and no deficiencies werefound.2 0PENTAIR(viii) Any advice related to the defect or failure to comply about the facility,  
(v)   The date on which the information of such defect or failure to comply was obtained.
: activity, or basiccomponent that has been, is being, or will be given to purchasers or licensees.
21 March 2014 (vi) In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured or being manufactured for one or more facilities or activities subject to the regulations in this Part.
None.(ix) In the case of an early site permit, the entities to whom an early site permit wastransferred.
See section ii above.
(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action and the length of time that has been or will be taken to complete the action.
Wall thickness measurements have performed and no deficiencies were found.
2
 
0PENTAIR (viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.
None.
(ix)   In the case of an early site permit, the entities to whom an early site permit was transferred.
Not applicable.
Not applicable.
If you have any questions or wish to discuss this matter or this report, please feel freeto contact me.Sincerely, David TuttleQuality Assurance Manager3}}
If you have any questions or wish to discuss this matter or this report, please feel free to contact me.
Sincerely, David Tuttle Quality Assurance Manager 3}}

Latest revision as of 01:56, 4 November 2019

Interim Report -10CFR 21 Evaluation Regarding Potential Deficiencies in Ensuring Customer Wall Thickness Requirements Were Met
ML14241A238
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 08/27/2014
From: Tuttle D
Anderson Greenwood Crosby Corp, Pentair Valves And Controls
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML14241A238 (3)


Text

PE NTAI R David Tuttle Quality Assurance Manager PENTAIR VALVES & CONTROLS 508-594-4430 (direct) 508-594-4249 (fax)

David.Tuttle@Pentair.com Mansfield, MA 02048 www.pentair.com August 27, 2014 VIA REGULAR MAIL:

U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 VIA OVERNIGHT DELIVERY:

U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2746

Subject:

Interim Report -10CFR 21 Evaluation Regarding Potential Deficiencies in Ensuring Customer Wall Thickness Requirements were Met.

The purpose of this letter is to close out the NRC report in general conformity to the requirements of 10CFR 21 Part 21.21 (a) (2).

This report is the result of an evaluation of a deviation in components that have been delivered to a nuclear power plant customer.

This report is to close out the subject line to the NRC of the 10CFR 21 evaluation and the results of that evaluation to date. Pentair Valves and Controls US LP, dba Anderson Greenwood Crosby is notifying the NRC of these results as well as the affected licensee.

Required information as per 10CFR Part 21.21 (d)(4) follows:

(i) Name and Address of the individual or individuals informing the Commission:

David Tuttle Quality Assurance Manager Pentair Valves and Controls US LP, dba Anderson Greenwood Crosby Mansfield Operations 55 Cabot Blvd Mansfield, MA 02048 6/9

PENTAIR (ii) Identification of the facility, the activity, or basic component supplied for such facility or such activity within the Unites States which fails to comply or contains a defect.

Four valves (N900299-00-0001 thru 0004) were delivered to Luminant Energy - Comanche Peak Station that were subsequently returned by the customer in order for the required wall thickness measurements to be performed.

(iii) Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.

Pentair Valves and Controls US LP, dba Anderson Greenwood Crosby Mansfield Operations 55 Cabot Blvd Mansfield, MA 02048 (iv) Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

The nature of the failure to comply is that Pentair did not perform customer required wall thickness measurements on the valve bodies.

Pentair requested the subject valves back from Luminant Energy on Returned Goods Authorization 2392 on March 21, 2014. Pentair has disassembled the subject valves and has performed the required wall thickness measurements.

(v) The date on which the information of such defect or failure to comply was obtained.

21 March 2014 (vi) In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be supplied for, manufactured or being manufactured for one or more facilities or activities subject to the regulations in this Part.

See section ii above.

(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action and the length of time that has been or will be taken to complete the action.

Wall thickness measurements have performed and no deficiencies were found.

2

0PENTAIR (viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.

None.

(ix) In the case of an early site permit, the entities to whom an early site permit was transferred.

Not applicable.

If you have any questions or wish to discuss this matter or this report, please feel free to contact me.

Sincerely, David Tuttle Quality Assurance Manager 3