ML20366A047

From kanterella
Jump to navigation Jump to search
Curtiss-Wright 10 CFR Part 21 Notification for SF-1154 Hydraulic Fluid Batch 17BLVS293
ML20366A047
Person / Time
Site: Beaver Valley, Palisades, Perry, Harris, Watts Bar, Grand Gulf, Arkansas Nuclear, Diablo Canyon, Comanche Peak  
Issue date: 11/18/2020
From: Anaya L
Curtiss-Wright Corp
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML20366A047 (3)


Text

\\

CURTISS-WRIGHT November 18, 2020 NRG Document Control U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Nuclear Division 2950 Birch Street Brea, CA 92821 T: 714.528.2301 IF. 714 528.0128 www.curtisswright.com/NuclearDivision

Subject:

10CFR Part 21 Notification for SF-1154 Hydraulic Fluid Batch 17BLVS293

Reference:

CWND Enertech NRG 20-003 Report

-(i) Name and address of the individual or individuals infonning the Commission Loretta Anaya, Quality Assurance Manager 2950 Birch Street Brea, CA 92821

-(ii) Identification of the facility, the activity, or the basic component supplied for such facility or such activity within the United States which fails to comply or contains defect.

Basic Component SF~1154 Hydraulic Fluid Batch Number 17BLVS2,93 provided by Enertech to the foll owing:

CUSTOMER SITE P.O.NO.

CW PROJECT Duke Energy Shearon Harris 03053099 520342 Entergy Palisades 10563794 T70275 Pacific Gas & Electric C Diablo Canyon 3501188958 770287 Pacific Gas & Electric Diablo Canyon 3501189966 770288 Soliet Almaraz E-19/122-PE 770293 KH&NP Kori K160440181 801261/830828 Luminant Comanche Peak 453278 830681 First Energy Beaver Valley 45520464 830683 Entergy Grand Gulf 10531691 830689 Entergy Arkansas Nuclear One 10542924 830715 Entergy Palisades 10546655 830724 First Energy Perrv 47806699 830730 TVA Watts Bar 4769368 830780 TVA Watts Bar 4514608 830806 Duke Energy Shearon Harris 03083722 960103 Pacific Gas & Electric Diablo Canyon 3501204336 990253 Duke Energy Shearon Harris 03097719 830821 I

CURl1SS--

WRIGHT Nuclear Division 2950 Birch Street Brea, CA 92821 T* 714 528.2301 I F: 714.528.0128 www.cu(tisswright.com/NuciearDivision

-(iii) Identification of the fim, constr,t.1cting the facility or supplying the basic component which fails to comply or contains a defect.

Supplied/Dedicated by:,

Curtiss Wright Nuclear Division Brea Operations - Enertech

  • 2950 Birch Street Brea, CA 92821 _

Manufactured by:

Momentive Batch Number 17BLVS293

-(ivJ Nature of the defect or failure to comply and the safety hazard wh,ich is created or could be created by such defect or failure to comply.

Duke Energy, based on a 1 0CFR Part 21 notification from Lake Engineering, notified Enertech of th*e issue related to silicon fluid, Batch 17BLVS293: The potential defect identified in the Fluid to have opaque semi solid material. The fluid used in va,rious snubbers. In snubbers, the semi-solid material could potentially block the bleed orifice and cause the snubber to lock up.

-(v) The date on which the infom,ation of such d~fect or failure to comply was obtained.

September 21, 2020

-(vi) In the case of a basic component which contains a defect or fails to comply, the number and location of these components in use at, supplied for, being supplied for, or may be *supplied for, manufacture or being manufactured for one or more facilities or activities subject to the regulations in this part.

CW Enertech procured (3) 200 kg (55-gallon drums) on December 18, 2017 Morrientive Batch 17BL VS293. This was $eparated into smaller 5-gallon container and supplied to the following sites:

CUSTOMER SITE P.O.NO.

Duke Energy Shearon Harris 03053099 Enter~

Palisades 10563794 Pacific Gas & Electric Diablo Canvon 3501188958 Pacific Gas & Electric Diablo Canyon 3501189966 Soliet Almaraz E-19/122-PE KH&NP Kori K160440181 Luminant Comanche Peak 453278 First Energy Beaver Valley 45520464 EnterQV Grand Gulf 10531691

(

CURl1SS--

- WRIGHT Enterav Entergy First Energy TVA TVA Duke Energy Pacific Gas & Electric Duke Energy Arkansas Nuclear One Palisades Perrv Watts Bar Watts Bar Shearon Harris Diablo Canyon Shearon Harris 10542924 10546655 47806699 4769368

'4514608 03083722 3501204336 03097719 Nuclear Division 2950 Birch Street Brea, CA 92821 T: 714.528.2301 I F: 714.528.0128 www.curtisswrlght.com/NuciearD1vision

-(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action, and the length of time that has been

~-

or will be taken to complete the action.

We understand the potential hazard in regards to the snubber fluid, however Enertech no longer has any fluid remaining for this batch. We then informed our customers the fluid was reported to NRC and we are not able to test the fluid and cannot determine if the flµid will have any impact on the safety function of the snubber.

-(viii) Any advice related to the defect or failure to comply about the*facility, activity, or

.basic component that has b~en, is being, or will be given to purchasers or licensees.

N/A.

  • -(ix) In the ~se of early site permit, the entities to whom an early site permit was transferred.

N/A CWND Eriertech customers noted herein were notified_ of their procurement requirements.

Regards,

'fi~f!:7-Quality Assurance Manager, Enertech Nuclear Division Curtiss-Wright-2950 Birch Street, Brea, CA 92821 T: 714-528-2301;1856 ID: 714-982-18561 F: 714-528-0128 IM: 562-371-5395 lanaya@curtlsswrlghlcom I www.curtisswrighlcom/NuclearDlvlsion