ML18051A237: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:.--<-. consumers Power **
{{#Wiki_filter:*~*
General Offices: 1945 West Parnell Jackson, Ml 49201 * (517) 788-0550 I December 15, 1982 I I Dennis M Crutchfield, Chief Operating Reactor Branch No 5
consumers Power
* Nuclear Reactor Regulation US Nuclear Commisssion
* compa~y
* Washington, DC 20555
                  .--<-.
* DOCKET 50-255 -LICENSE DPR-20 -\ \ t . .. PALISADES PLANT -PROPOSED TECHNICAL SPECIFICATION CHANGE REQUEST -"SAFETY INJECTION TANK BORON CONCENTRATION" Attached are three (3) originals and thirty-seven (37) conformed copies of a Request for Change to the Palisades Technical Specifications.
General Offices:   1945 West Parnell ~oad, Jackson, Ml 49201 * (517) 788-0550 I
The proposed . changes provide limiting conditions for operation, the surveillance requirements and the basis for a reduction in the required boron concentration in Safety Injection Tank T-82B for the remainder of cycle 5. The proposed change involves a single safety issue, therefore a check in the *amount of $4,000.00 is attached pursuant to 10 CFR 170.22, Class III change. Nuclear Licensing Administrator CC Administrator, Region III, USNRC .. NRC Resident Inspector  
I I
-Palisades r 8212200070 821215 ! . *. '\\. PDR ADOCK 05000255 \ I p PDR OC1282-0013A-NL02  
December 15, 1982
/J <toa0.oo}}
                                                                        \ \
t...
Dennis M Crutchfield, Chief Operating Reactor Branch No 5
* Nuclear Reactor Regulation US Nuclear Regulat~ry Commisssion
* Washington, DC             20555
* DOCKET 50-255 - LICENSE DPR     PALISADES PLANT - PROPOSED TECHNICAL SPECIFICATION CHANGE REQUEST -
                                  "SAFETY INJECTION TANK BORON CONCENTRATION" Attached are three (3) originals and thirty-seven (37) conformed copies of a Request for Change to the Palisades Technical Specifications. The proposed
  . changes provide limiting conditions for operation, the surveillance requirements and the basis for a reduction in the required boron concentration in Safety Injection Tank T-82B for the remainder of cycle 5.
The proposed change involves a single safety issue, therefore a check in the
    *amount of $4,000.00 is attached pursuant to 10 CFR 170.22, Class III change.
Nuclear Licensing Administrator CC   Administrator, Region III, USNRC
        . NRC Resident Inspector - Palisades                                       /J <toa0.oo r 8212200070 821215 ! . *.                         '\\.
PDR ADOCK 05000255 \
p                           PDR 1 ~
I OC1282-0013A-NL02}}

Revision as of 21:03, 21 October 2019

Forwards Application to Amend License DPR-20,changing Tech Spec Section 3.3.1 & Table 4.2.1 to Reduce Required Boron Concentration in Safety Injection Tank T-82B for Remainder of Cycle 5
ML18051A237
Person / Time
Site: Palisades Entergy icon.png
Issue date: 12/15/1982
From: Vandewalle D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML18051A238 List:
References
NUDOCS 8212200070
Download: ML18051A237 (1)


Text

  • ~*

consumers Power

  • compa~y

.--<-.

General Offices: 1945 West Parnell ~oad, Jackson, Ml 49201 * (517) 788-0550 I

I I

December 15, 1982

\ \

t...

Dennis M Crutchfield, Chief Operating Reactor Branch No 5

  • Nuclear Reactor Regulation US Nuclear Regulat~ry Commisssion
  • DOCKET 50-255 - LICENSE DPR PALISADES PLANT - PROPOSED TECHNICAL SPECIFICATION CHANGE REQUEST -

"SAFETY INJECTION TANK BORON CONCENTRATION" Attached are three (3) originals and thirty-seven (37) conformed copies of a Request for Change to the Palisades Technical Specifications. The proposed

. changes provide limiting conditions for operation, the surveillance requirements and the basis for a reduction in the required boron concentration in Safety Injection Tank T-82B for the remainder of cycle 5.

The proposed change involves a single safety issue, therefore a check in the

  • amount of $4,000.00 is attached pursuant to 10 CFR 170.22, Class III change.

Nuclear Licensing Administrator CC Administrator, Region III, USNRC

. NRC Resident Inspector - Palisades /J <toa0.oo r 8212200070 821215 ! . *. '\\.

PDR ADOCK 05000255 \

p PDR 1 ~

I OC1282-0013A-NL02