| title = Forwards Analysis of Reactor Pressure Vessel Fast Neutron Fluence & PTS Ref Temps for Palisades Nuclear Plant. Rept Concludes That PTS Screening Criteria Will Be Exceeded at Axial Welds in Sept 2001 as Opposed to Mar 2002
| title = Forwards Analysis of Reactor Pressure Vessel Fast Neutron Fluence & PTS Ref Temps for Palisades Nuclear Plant. Rept Concludes That PTS Screening Criteria Will Be Exceeded at Axial Welds in Sept 2001 as Opposed to Mar 2002
| author name = SMEDLEY R W
| author name = Smedley R
| author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.),
| author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.),
| addressee name =  
| addressee name =  

Revision as of 19:50, 17 June 2019

Forwards Analysis of Reactor Pressure Vessel Fast Neutron Fluence & PTS Ref Temps for Palisades Nuclear Plant. Rept Concludes That PTS Screening Criteria Will Be Exceeded at Axial Welds in Sept 2001 as Opposed to Mar 2002
ML18057A231
Person / Time
Site: Palisades Entergy icon.png
Issue date: 05/17/1990
From: Smedley R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18057A232 List:
References
RTR-REGGD-01.099, RTR-REGGD-1.099 TAC-59970, NUDOCS 9005240071
Download: ML18057A231 (2)


Text

... _. .[ ,. consumers Power PDWERINli MICHlliAN'S PRDliRESS General Offices: 1945 West Parnall Road,Jackson,'MI 49201 * (517) 788-0550 May 17, 1990 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 -LICENSE DPR-20 -PALISADES PLANT -COMPLIANCE WITH PRESSURIZED THERMAL SHOCK REGULATION 10CFR50.61 AND REGULATORY GUIDE 1.99 REVISION 2 (TAC NO. 59970) Consumers Power Company (CPC) submittal on April 3, 1989 provided a revised report on reactor vessel fluence for Cycles 1 -8. Attached is the vessel fluence reduction report describing the effect of incorporating fuel management for the Cycle 9 core loading pattern. In this proposed Cycle 9 design, 16 thrice-burned fuel assemblies with zircaloy-clad hafnium absorber rods will be used at the selected core peripheral locations to protect the vessel axial welds from neutron fast flux E>l.O MeV. Remaining core pheral locations will be loaded with twice-burned fuel assemblies.

All once-burned and fresh fuel assemblies will be inside the core away from the peripheral locations.

This report reflects results based upon the development of in-house logy utilizing the DOT 4.3 discrete ordinates transport code and Reactor Engineering Analyses performed during the period of 1987-1990.

It concludes that the PTS screening criteria will be exceeded at the axial welds in September, 2001, as opposed to the previously reported exceed date of March, 2002. The difference reflects an improvement in vessel flux reduction in Cycle 9 relative to Cycle 8 and slightly higher vessel flux levels calculated by the refined in-house transport methodology relative to the Westinghouse methodology previously utilized.

Thus, the previously OC0590-0016-NL02

\ A CMS' *1\/E"RGY COMPANY

.. l ... e

  • Nuclear Regulatory Commission Palisades Nuclear Plant Thermal Shock Reg 10CFR50.61/Reg Guide 1.99 Rev 2 May 17, 1990 derived conclusion that the flux reductions achieved in the Cycle 8 and 9 core loading patterns are, by themselves, insufficient to allow plant operation to the current expected end of life in 2011 remains valid. Further measures, eg, greater flux reduction, Regulatory Guide 1.154 analysis, vessel shielding etc, are necessary to allow plant operation to the nominal end of plant life and beyond. Richard W Smedley Staff Licensing Engineer CC Administrator, Region III, USNRC NRC Resident Inspector

-Palisades OC0590-0016-NL02