Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- IR 05000390/2019004 + (20:17:24, 19 December 2024)
- ML20043F233 + (20:17:33, 19 December 2024)
- ML20043F231 + (20:17:34, 19 December 2024)
- ML20043F228 + (20:17:35, 19 December 2024)
- ML20043F226 + (20:17:36, 19 December 2024)
- ML20043F224 + (20:17:37, 19 December 2024)
- ML20043F223 + (20:17:37, 19 December 2024)
- 05000254/LER-1989-024, :on 891214,main Turbine Unexpectedly Tripped Following Isolation of Reactor Water Level Switch (Lits). Caused by Channel B Lits Having Been Previously Replaced W/ Switch That Operated Reverse Function + (20:17:42, 19 December 2024)
- ML20043F215 + (20:17:44, 19 December 2024)
- ML20043F212 + (20:17:45, 19 December 2024)
- ML20043F210 + (20:17:46, 19 December 2024)
- AECM-90-0100, Forwards 1989 Annual Financial Repts for Sys Energy Resources,Inc & South Mississippi Electric Power Assoc + (20:17:47, 19 December 2024)
- ML20043F204 + (20:17:49, 19 December 2024)
- ML20043F199 + (20:17:50, 19 December 2024)
- ML20043F192 + (20:17:51, 19 December 2024)
- ML20043F191 + (20:17:52, 19 December 2024)
- ML20043F190 + (20:17:53, 19 December 2024)
- ML20043F188 + (20:17:54, 19 December 2024)
- ML20043F185 + (20:17:55, 19 December 2024)
- ML20043F183 + (20:17:56, 19 December 2024)
- ML20043F179 + (20:17:57, 19 December 2024)
- ML20043F174 + (20:17:59, 19 December 2024)
- ML20043F173 + (20:18:00, 19 December 2024)
- 05000374/LER-1990-009-02, :on 900510,RWCU Outboard Suction Isolation Valve 2G33-F004 Auto Closed Which Tripped RWCU Pump B. Caused by Procedure Deficiency.Procedure LTS-500-209 Will Be Revised + (20:18:01, 19 December 2024)
- ML20043F170 + (20:18:03, 19 December 2024)
- 05000364/LER-1990-001-01, :on 900512,reactor Tripped Due to lo-lo Water Level in Steam Generator 2A.Caused by Procedural Inadequacy. Procedure FNP-2-STP-151 Revised to Provide Addl Initial Conditions to Prevent Subj Event + (20:18:04, 19 December 2024)
- ML20043F163 + (20:18:06, 19 December 2024)
- ML20043F161 + (20:18:09, 19 December 2024)
- 3F0690-04, Provides Supplemental Info on Reactor Bldg Flooding,Per Util Describing Resolution Plan Being Pursued.Util Has Limited Vol of Water Contributed by Borated Water Storage Tank & Sodium Hydroxide Tank to Flood Level + (20:18:10, 19 December 2024)
- ML20043F159 + (20:18:12, 19 December 2024)
- 05000482/LER-1990-008, :on 900504,fuel Bldg/Control Room Ventilation Isolation Signals Received from Exhaust Radiation Monitor. Caused by Burned Out Lamp & Blown Fuse in Power Supply.Fuse & Lamp Replaced & Monitor Returned to Svc + (20:18:14, 19 December 2024)
- 05000445/LER-1990-013, :on 900509,while Installing Jumpers Across Feedwater Pump Speed Controllers,Pump Coastdown Occurred, Resulting in Loss of Feedwater Flow & Reactor Trip.Caused by Inadequate Procedure Review.Review Performed + (20:18:16, 19 December 2024)
- IR 05000341/1990008 + (20:18:22, 19 December 2024)
- ML20043F152 + (20:18:24, 19 December 2024)
- ML20043F148 + (20:18:24, 19 December 2024)
- ML20043F146 + (20:18:26, 19 December 2024)
- ML20043F138 + (20:18:27, 19 December 2024)
- ML20043F136 + (20:18:29, 19 December 2024)
- ML20043F131 + (20:18:31, 19 December 2024)
- 05000373/LER-1990-009-01, :on 900511,apparent Ruptured Diaphragm Found on Pressure Differential Switch in RCIC Steam Line.Caused by Torn Diaphragm Inside Switch.Replacement Switch Installed, Calibr & Functionally Tested Satisfactorily + (20:18:32, 19 December 2024)
- ML20043F124 + (20:18:34, 19 December 2024)
- 05000317/LER-1990-017, :on 900505,pin Hole Leak Observed in Discharge Piping of Saltwater Pump 13.Caused by Localized Corrosion. Leaking Spool Piece Removed & Blank Flange Installed + (20:18:36, 19 December 2024)
- IR 05000461/1990012 + (20:18:44, 19 December 2024)
- ML20043F119 + (20:18:46, 19 December 2024)
- IR 05000263/1989020 + (20:18:48, 19 December 2024)
- ML20043F112 + (20:18:49, 19 December 2024)
- ML20043F110 + (20:18:50, 19 December 2024)
- ML20043F107 + (20:18:52, 19 December 2024)
- ML20043F105 + (20:18:53, 19 December 2024)
- ML20043F102 + (20:18:54, 19 December 2024)
- ML20043F101 + (20:18:55, 19 December 2024)