List of results
- ML20247R798 + (23:59:06, 1 December 2024)
- ML20247R792 + (23:59:07, 1 December 2024)
- ML20247R790 + (23:59:08, 1 December 2024)
- ML20247R791 + (23:59:08, 1 December 2024)
- ML20247R789 + (23:59:09, 1 December 2024)
- 05000369/LER-1989-021-01, :on 890623,discovered That Design of Sys Did Not Take Into Account temp-induced Difference in Pressure Gradients Inside & Outside Annulus.Caused by Design Deficiency.Sys Setpoint Mods Implemented + (23:59:11, 1 December 2024)
- ML20247R784 + (23:59:12, 1 December 2024)
- ML20247R785 + (23:59:12, 1 December 2024)
- 05000482/LER-1989-017, :on 890830,control Room Ventilation Isolation Signal Initiated When Chlorine Monitor Indicated High Level. Caused by Spurious Spike.Recorder Connected to Chlorine Monitor GK-AITS-3 to Monitor Channel Behavior + (23:59:14, 1 December 2024)
- 05000458/LER-1998-001-04, :on 980417,flow Rate Through SBGTS Filter Assembly Units Was Found to Be Higher than Design Flow Rate. Cause Analysis Is Currently Being Performed.Detailed Evaluation of Sys Ability to Perform Was Done + (23:59:17, 1 December 2024)
- ML20247R780 + (23:59:18, 1 December 2024)
- ML20247R779 + (23:59:18, 1 December 2024)
- ML20247R775 + (23:59:19, 1 December 2024)
- ML20247R774 + (23:59:19, 1 December 2024)
- ML20247R773 + (23:59:20, 1 December 2024)
- ML20247R772 + (23:59:20, 1 December 2024)
- 05000368/LER-1986-017, :on 860604,discovered That Required Type C Testing of Containment Isolation Valves Not Performed Resulting in Noncompliance W/Tech Specs.Caused by Personnel Error.Actions Taken to Test Affected Valves + (23:59:23, 1 December 2024)
- BSEP-98-0098, Documents Util Responses,Provided to NRC During 980330 & 0414 Telcons Re Core Shroud re-inspection Plan + (23:59:24, 1 December 2024)
- ML20247R769 + (23:59:24, 1 December 2024)
- 05000298/LER-1989-015, :on 890503,discovered That Safety/Relief Valve Setpoint Variance Not within Tech Spec Limit.Caused by Corrosion Bonding of Pilot Disc to Seat & Setpoint Drift. Valves Inspected,Refurbished & Tested + (23:59:26, 1 December 2024)
- ML20247R763 + (23:59:27, 1 December 2024)
- ML20247R762 + (23:59:27, 1 December 2024)
- ML20247R759 + (23:59:28, 1 December 2024)
- JPN-89-036, Forwards Application for Amend to License DPR-59,revising Tech Spec 4.5.1.b to Change Flow Rate Test Requirements of Core Spray Pumps + (23:59:29, 1 December 2024)
- ML20247R757 + (23:59:29, 1 December 2024)
- ML20247R754 + (23:59:30, 1 December 2024)
- ML20247R749 + (23:59:31, 1 December 2024)
- ML20247R751 + (23:59:31, 1 December 2024)
- ML20247R746 + (23:59:32, 1 December 2024)
- ML20247R744 + (23:59:33, 1 December 2024)
- ML20247R740 + (23:59:34, 1 December 2024)
- ML20247R741 + (23:59:34, 1 December 2024)
- ML20247R738 + (23:59:35, 1 December 2024)
- ML20247R735 + (23:59:37, 1 December 2024)
- ML20247R736 + (23:59:37, 1 December 2024)
- ML20247R731 + (23:59:38, 1 December 2024)
- ML20247R732 + (23:59:38, 1 December 2024)
- 05000395/LER-1988-012, :on 881202,identified Design Deficiency W/Class 1E 125 Volt Dc Distribution Sys.Caused by Design Deficiency. Mods to Dc Sys Appear to Be Ultimate Resolution to Design Problem + (23:59:40, 1 December 2024)
- ML20247R729 + (23:59:41, 1 December 2024)
- JPN-89-034, Forwards Application for Amend to License DPR-59,revising Tech Spec to Reflect LPCI loop-selection-logic Mod & to Eliminate Redundant & Unnecessary Surveillance Testing by Making Terminology Used Consistent W/Existing Criteria + (23:59:42, 1 December 2024)
- ML20247R726 + (23:59:43, 1 December 2024)
- ML20247R725 + (23:59:43, 1 December 2024)
- ML20247R721 + (23:59:44, 1 December 2024)
- ML20247R723 + (23:59:44, 1 December 2024)
- ML20247R719 + (23:59:45, 1 December 2024)
- ML20247R718 + (23:59:46, 1 December 2024)
- ML20247R717 + (23:59:46, 1 December 2024)
- ML20247R715 + (23:59:47, 1 December 2024)
- B13295, Proposed Tech Specs Re Limiting Conditions for Operation & Surveillance Requirements & RCS Operational Leakage + (23:59:48, 1 December 2024)
- ML20247R710 + (23:59:49, 1 December 2024)
- ML20247R708 + (23:59:49, 1 December 2024)