- IR 05000206/1986003 + (ML20153E205)
- 05000219/LER-1988-015, :on 880805,reactor Isolation Signal Inadvertently Initiated During Intermediate Range Neutron Monitor Front Panel Surveillance.Caused by Circuit Not Configured to Facilitate Testing.Fuse Replaced + (ML20153E213)
- ML20153E217 + (ML20153E217)
- ML20153E220 + (ML20153E220)
- 05000289/LER-1998-009, Forwards LER 98-009-00 Re Potential Loss of HPI During Postulated LOCA with Most Limiting Single Failure.Caused by Misapplication of Design Inputs When Operating Procedures Were Changed Prior to Startup for Current Operating Cy + (ML20153E221)
- 05000354/LER-1988-021, :on 880728,cracks Discovered in Ductwork of Filtration,Recirculation & Ventilation Sys D.Caused by Design Deficiency.Stiffeners & Support Added to Flow Straighteners + (ML20153E223)
- ML20153E224 + (ML20153E224)
- ML20153E227 + (ML20153E227)
- 05000289/LER-1998-009-01, :on 980820,discovered Potential Loss of HPI During Postulated Loca.Caused by Misapplication or Interpretation of Design Inputs.Revised OL Was Implemented & Mut Pressure & Level Limits Analysis Revised + (ML20153E228)
- ML20153E230 + (ML20153E230)
- ML20153E233 + (ML20153E233)
- ML20153E234 + (ML20153E234)
- ML20153E237 + (ML20153E237)
- IR 05000445/1988026 + (ML20153E238)
- ML20153E242 + (ML20153E242)
- ML20153E246 + (ML20153E246)
- ML20153E251 + (ML20153E251)
- ML20153E256 + (ML20153E256)
- ML20153E257 + (ML20153E257)
- ML20153E259 + (ML20153E259)
- ML20153E265 + (ML20153E265)
- ML20153E266 + (ML20153E266)
- IR 05000368/1988003 + (ML20153E268)
- ML20153E274 + (ML20153E274)
- IR 05000312/1986003 + (ML20153E276)
- ML20153E278 + (ML20153E278)
- ML20153E279 + (ML20153E279)
- ML20153E280 + (ML20153E280)
- IR 05000498/1988019 + (ML20153E286)
- ML20153E290 + (ML20153E290)
- ML20153E292 + (ML20153E292)
- ML20153E296 + (ML20153E296)
- ML20153E298 + (ML20153E298)
- ML20153E300 + (ML20153E300)
- ML20153E303 + (ML20153E303)
- ML20153E304 + (ML20153E304)
- ML20153E309 + (ML20153E309)
- ML20153E310 + (ML20153E310)
- ML20153E311 + (ML20153E311)
- ML20153E317 + (ML20153E317)
- ML20153E318 + (ML20153E318)
- ML20153E321 + (ML20153E321)
- ML20153E326 + (ML20153E326)
- ML20153E327 + (ML20153E327)
- ML20153E328 + (ML20153E328)
- ML20153E331 + (ML20153E331)
- ML20153E332 + (ML20153E332)
- ML20153E333 + (ML20153E333)
- ML20153E334 + (ML20153E334)
- 05000304/LER-1986-004-01, :on 860120,inadvertent Closing of Valve 2MOV-VC8100 Occurred Due to Failure of Test Switch.Switch Replaced + (ML20153E335)