Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20127C853 + (ML20127C853)
- IR 05000155/1992017 + (ML20127C855)
- ML20127C857 + (ML20127C857)
- 05000369/LER-1985-013-01, :on 850502,during Refueling,Gearcase Lubricating Grease Found in Electrical Compartments of Limitorque Motor Operated Valve Actuators 1VX-1A & 1VX-2B. Caused by Error During Previous Maint Work + (ML20127C860)
- ML20127C861 + (ML20127C861)
- ML20127C863 + (ML20127C863)
- 05000482/LER-1985-028, :on 850516,auxiliary Feedwater Actuation Signal Initiated When Steam Generator D Decreased Below lo-lo Actuation Setpoint.Caused by Personnel Error.Personnel Counseled & Required to Read LER + (ML20127C864)
- IR 05000424/1984014 + (ML20127C866)
- ML20127C870 + (ML20127C870)
- ML20127C872 + (ML20127C872)
- ML20127C873 + (ML20127C873)
- ML20127C874 + (ML20127C874)
- ML20127C876 + (ML20127C876)
- ML20127C877 + (ML20127C877)
- ML20127C878 + (ML20127C878)
- ML20127C879 + (ML20127C879)
- ML20127C880 + (ML20127C880)
- ML20127C882 + (ML20127C882)
- ML20127C883 + (ML20127C883)
- L-82-457, Forwards Updated Const Status Rept as of 820930.Info for Inclusion in NUREG-0030 + (ML20127C884)
- ML20127C886 + (ML20127C886)
- ML20127C889 + (ML20127C889)
- ML20127C890 + (ML20127C890)
- ML20127C893 + (ML20127C893)
- 3F0485-04, Responds to Violations Noted in Insp Rept 50-302/85-05. Util Disagrees W/Stated Violation.Bioassay Program Not Included in Nov 1972 Reg Guide 1.33,App A,Therefore,Util Not in Violation of Tech Spec 6.8.1 + (ML20127C894)
- ML20127C897 + (ML20127C897)
- ML20127C898 + (ML20127C898)
- ML20127C899 + (ML20127C899)
- PLA-1401, Forwards Updated Const Status Repts as of 820930.Info for Inclusion in NUREG-0030.Unit 1 Has Loaded Fuel & in Operations Startup Mode + (ML20127C900)
- 05000369/LER-1985-017-01, :on 850515,diesel Generator 1A Experienced Invalid Automatic Start Due to Unit Blackout Signal.Caused by Electrical Disturbance to Power Transmission Sys During Severe Storm & Listed Design Deficiency + (ML20127C902)
- IR 05000155/1992019 + (ML20127C903)
- ML20127C904 + (ML20127C904)
- ML20127C905 + (ML20127C905)
- ML20127C906 + (ML20127C906)
- IA-92-368, Summary of Minutes of 42ND ACNW Meeting on 920422-24 + (ML20127C906)
- ML20127C908 + (ML20127C908)
- ML20127C910 + (ML20127C910)
- ML20127C912 + (ML20127C912)
- ML20127C913 + (ML20127C913)
- ML20127C914 + (ML20127C914)
- ML20127C915 + (ML20127C915)
- ML20127C918 + (ML20127C918)
- ML20127C919 + (ML20127C919)
- ML20127C920 + (ML20127C920)
- 05000295/LER-1985-017-04, :on 850514,during Insp of safety-related Snubbers,Two of Eight Pulled Due to Low Fuel Levels & Declared Inoperable.Caused by Poor Seal Conditions Allowing Leakage of Hydraulic Fluid + (ML20127C922)
- ML20127C923 + (ML20127C923)
- ML20127C925 + (ML20127C925)
- ML20127C926 + (ML20127C926)
- ML20127C929 + (ML20127C929)
- ML20127C931 + (ML20127C931)
- ML20127C933 + (ML20127C933)