Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20069L236 + (ML20069L236)
- ML20069L245 + (ML20069L245)
- ML20069L246 + (ML20069L246)
- 05000348/LER-1983-011-03, /03L-0:on 830322,during Control Room Train A-B Ventilation Operability Test,Train Control Room Emergency Ventilation Sys B Declared Inoperable.Caused by Failed Damper Due to Breaker Overload.Overloads Reset + (ML20069L249)
- ML20069L253 + (ML20069L253)
- 05000395/LER-1983-029-03, /03L-0:on 830320,w/reactor Bldg Purge Initiated, Radiation Monitor RM-A4 Read Higher than Normal Pump RM-A4 & Detector Secured to Change Filter,Leaving Purge Unmonitored for 5 Minutes.No Activity Released During Event + (ML20069L254)
- ML20069L257 + (ML20069L257)
- ML20069L266 + (ML20069L266)
- ML20069L268 + (ML20069L268)
- 05000261/LER-1983-003, Forwards LER 83-003/01T-0 + (ML20069L270)
- ML20069L276 + (ML20069L276)
- 05000261/LER-1983-003-01, /01T-0:on 830410,svc Water Leak Discovered on Containment Fan Cooler HVH-3.Caused by Corrosion/Erosion of Cooler Tubing.Leak Repaired + (ML20069L277)
- ML20069L288 + (ML20069L288)
- ML20069L309 + (ML20069L309)
- ML20069L317 + (ML20069L317)
- 05000260/LER-1983-012, Forwards LER 83-012/03L-0 + (ML20069L323)
- ML20069L329 + (ML20069L329)
- ML20069L333 + (ML20069L333)
- ML20069L336 + (ML20069L336)
- 05000328/LER-1983-049, Forwards LER 83-049/03L-0 + (ML20069L338)
- 05000260/LER-1983-012-03, /03L-0:on 830323,during Startup Testing at 50.4% Power,Discovered Process Computer Contained Nonconservative Kf Factor.Caused by Increased Recirculation Stops at End of Previous Cycle for Increased Flow Operation + (ML20069L345)
- 05000328/LER-1983-049-03, /03L-0:on 830324,while in Mode 1,ice Condensor Intermediate Deck Door in Bay 11 Found Frozen Closed During Routine Insp.Caused by Leaks in Condensate Drain Lines of Air Handling Units 13 & 14.Update Rept Will Be Sent Later + (ML20069L348)
- PY-CEI-NRR-0039, Forwards Rev 2 to Containment Annulus Concrete Design, Const & Testing for Perry Nuclear Power Plant + (ML20069L353)
- GO2-83-333, Final Deficiency Rept Re Failure of Temp Control Modules WMA-TS-12A & 12B During Qualification Testing (Condition 238).Initially Reported on 830310.Printed Circuit Board Traces Replaced W/Wire Jumpers.Condition Not Reportable + (ML20069L358)
- A03049, Forwards Response to Generic Ltr 83-10C Re Plans & Schedules for Resolving NUREG-0737,Item II.K.3.5, Automatic Trip of Reactor Coolant Pumps. Trip Can Be Achieved Safely & Reliably by Operator,When Required + (ML20069L360)
- ML20069L365 + (ML20069L365)
- 05000269/LER-1983-005, Forwards LER 83-005/03L-0.Detailed Event Analysis Encl + (ML20069L370)
- 3F0694-05, Forwards Rev 6-4 to Physical Security Plan.Rev Withheld (Ref 10CFR73.21) + (ML20069L373)
- ML20069L375 + (ML20069L375)
- ML20069L376 + (ML20069L376)
- ML20069L377 + (ML20069L377)
- L-83-242, Final Deficiency Rept Re Ground Fault in Reactor Protection Sys.Initially Reported on 830310.Condition Not Reportable Under 10CFR50.55(e) & Part 21.No Adverse Effect Would Result If Occurrence Left Uncorrected & Cables Left in Place + (ML20069L379)
- ML20069L381 + (ML20069L381)
- ML20069L382 + (ML20069L382)
- ML20069L383 + (ML20069L383)
- ML20069L386 + (ML20069L386)
- ML20069L388 + (ML20069L388)
- 05000269/LER-1983-005-03, /03L-0:on 830316,engineering Evaluation Revealed That Double Isolation Criteria Not Met for Standby Shutdown Facility Makeup Water Pump tie-ins to Fuel Transfer Tubes. Caused by Design Deficiency.Procedures Will Be Revised + (ML20069L394)
- ML20069L403 + (ML20069L403)
- ML20069L406 + (ML20069L406)
- ML20069L409 + (ML20069L409)
- ML20069L411 + (ML20069L411)
- HL-4616, Monthly Operating Repts for May 1994 for Ei Hatch Nuclear Plant for Units 1 & 2 + (ML20069L412)
- ML20069L414 + (ML20069L414)
- 05000313/LER-1983-008, Forwards LER 83-008/03L-0 + (ML20069L415)
- PY-CEI-NRR-1813, Monthly Operating Rept for May 1994 for Perry Nuclear Power Plant,Unit 1 + (ML20069L418)
- GO2-83-295, Amends Response to NRC Re Violations Noted in IE Insp Rept 50-397/82-21.Corrective Actions:Fsar Rev & Rev 2 to Electrical Separation Practices Document Will Be Issued by 830415 + (ML20069L419)
- ML20069L421 + (ML20069L421)
- ML20069L423 + (ML20069L423)
- ML20069L425 + (ML20069L425)
- ML20069L432 + (ML20069L432)