ML20069L383

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for May 1994 for Waterford 3
ML20069L383
Person / Time
Site: Waterford Entergy icon.png
Issue date: 05/31/1994
From: Becker T, Burski R
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
W3F1-94-0081, W3F1-94-81, NUDOCS 9406170378
Download: ML20069L383 (7)


Text

_ _.

t W ENTERGY f"'*"" [*;'"*"** '"*-

R. F. Durski W3F1-94-0081 A4.05 PR June 15, 1994 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Monthly Operating Report Gentlemen:

Attached is the subject monthly report which covers the operating statistics for the month of May,1994.

This report is submitted per Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility Operating License No. NPF-38.

Very truly yours, 2

/.

(i b

pR{F.Julcsi

,/l

/

.j t., /

Direct'or Nuclear Safety RFB/ssf Attachment cc:

L.J. Callan, (NRC Region IV)

R.B. McGehee N.S. Reynolds F. Yost (Utility Data Institute, Inc.)

J.T. Wheelock (INPO Records Center)

/p NRC Resident Inspectors Office (WADM526) g 9406170378 940531

.n,,,L.L PDR ADOCK 050003B2 R

PDR

NRC MONTHLY OPERATING REPORT

SUMMARY

OF OPERATIONS WATERFORD 3 MAY 1994 The unit operated at an average reactor power of 99.7% and experienced no shutdowns or significant power reductions during the period.

j j

l PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES WATERFORD 3 During the month of May 1994, there were no pressurizer safety valve failures or challenges.

4 OPEF ATING DATA REPORT DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: JUNE,1994 COMPLETED BY:

T.S. BECKER TELEPHONE: 504-739-6683 OPERATING STATUS 1.

Reporting Period: May,1994 Gross Hours in Reporting Period: 744 2.

Currently Authorized Power Level (MWt): 3390 Maximum Dependable Capacity (Net MWe): 1075 Design Electrical Rating (Net MWe): 1104 3.

Power Level to which Restricted (if any) (Net MWe): N/A 4.

Reasons for Restriction (if any): N/A THIS MONTH YR TO DATE CUMULATIVE 5.

Number of Hours Reactor was Critical 744.0 2,485.8 63,585.8 6.

Reactor Reserve Shutdown Hours 7.

Hours Generator was On-line 744.0 2,430.3 62,718.5 8.

Unit Reserve Shutdown Hours 0- 9.

Gross Thermal Energy Generated (MWH) 2,515,334 8,057,936 207,086,413

10. Gross Electrical Energy Generated (MWH) 833,310 2,640,350 69,061,130
11. Net Electrical Energy Generated (MWH) 799,050 2,508,592 65,819,037
12. Reactor Service Factor 100.0 68.6 83.5
13. Reactor Availability Factor 100.0 68.6 83.5
14. Unit Service Factor 100.0 67.1 82.4
15. Unit Availability Factor 100.0 67.1 82.4
16. Unit Capacity Factor (using MDC) 99.9 64.4 80.4
17. Unit Capacity Factor (Using DER) 97.3 62.7 78.3
18. Unit Forced Outa0e Rate 0.0 0.8 3.4

OPERATING DATA REPORT DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: JUNE,1994 COMPLETED BY:

T.S. BECKER TELEPHONE: 504-739-6683 OPERATING DATA REPORT (Con't) 19.

Shutdowns Scheduled over next 6 Months (type, date and duration of each):

N/A 20.

If Shutdown at end of report period, estimated date of startup:

21.

Unit in Commercial Operation THIS MONTH YR TO DATE CUMULATIVE

22. Hours in Reporting Period 744.0 3623.0 76,128.0
23. Unit Forced Outage Hours 0.0 20.3 2,199.0 24.

Nameplate Rating (Gross MWe): 1200 25.

If Changes Occur in Capacity Ratings (Items Number 2 and 24) Since Last Report, Give Reasons: N/A

AVERAGE DAILY UNIT POWER LEVEL DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: JUNE,1994 COMPLETED BY:

T.S. BECKER TELEPHONE: 504 739 6683 MONTH MAY.1994 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-NET)

(MWo-NET) 1 1077 17 1065 2

1077 18 1076 3

1073 19 1079 4

1074 20 1078 5

1077 21 1078 6

1077 22 1079 7

1081 23 1079 8

1080 24 1077 9

1080 25 1077 10 1080 26 1078 11 1079 27 990 l

12 1080 28 1074 13 1081 29 1075 14 1080 30 1061 15 1077 31 1075 16 1078 lNSTRUCTIONS On this format, list the average daily unit power level in MWo-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

4-UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: JUNE,1994 COMPLETED BY:

T.S. BECKER TELEPHONE: 504-739 4683 REPORT FOR MAY.1994 Type Method of Shutting F = Forced Duration Down the Reactor or Cause, Comments and Number Date S = Scheduled (Hours)

Reason (1)

Reducino Power (2)

Corrective Actions NONE i

(t) REASON (2) METHOD A=

Equipment Failure (explain) 1=

Manual B=

Maintenance or Test 2=

Manual Scram C=

Refueling 3=

Automatic Scram D=

Regulatory Restriction 4.=

Continuation frorn Previous Period E=

Operator Training and 5=

Power Reduction License Examination 6=

Other (explain)

F=

Administrative G=

Operational Error (explain)

H=

Other (explain)

,