- 05000368/LER-1982-002-03, /03L-0:on 820119,control Power Fuse in Motor Control Ctr for Valve Operation Found Open.Cause Not Stated. Fuse Replaced,Tested & Returned to Svc.Engineering Investigation Underway + (ML20041B162)
- IR 05000289/1981013 + (ML20041B163)
- ML20041B166 + (ML20041B166)
- ML20041B168 + (ML20041B168)
- ML20041B170 + (ML20041B170)
- ML20041B171 + (ML20041B171)
- ML20041B172 + (ML20041B172)
- ML20041B173 + (ML20041B173)
- ML20041B174 + (ML20041B174)
- ML20041B175 + (ML20041B175)
- ML20041B177 + (ML20041B177)
- ML20041B178 + (ML20041B178)
- ML20041B179 + (ML20041B179)
- ML20041B180 + (ML20041B180)
- ML20041B181 + (ML20041B181)
- ML20041B183 + (ML20041B183)
- IR 05000528/1982001 + (ML20041B184)
- IR 05000508/1981021 + (ML20041B185)
- ML20041B186 + (ML20041B186)
- ML20041B188 + (ML20041B188)
- 05000316/LER-1982-002, Forwards Updated LER 82-002/01X-1 + (ML20041B189)
- PNO-III-82-022A, on 820217,stop Work Order Issued by Util Due to Vendor Mislabeling of Stainless Steel Welding Electrode as Low Hydrogen Mild Steel E-7018.Nonconformance Rept Issued.Corrective Actions Under Review + (ML20041B191)
- PNO-I-82-020, on 820217,two Contractor Employees Observed Smoking One Pipe Containing Unidentified Substance in Protected Area Yard.Site Access Terminated + (ML20041B192)
- 05000316/LER-1982-002-01, Essential Svc Water Valves WMO-734 & 738 Were Not Tested as Required by Tech Specs.Caused by Valves WMO-734 & 738 Being Inadvertently Omitted During Oct 1979 Procedure Revision + (ML20041B195)
- ML20041B196 + (ML20041B196)
- ML20041B197 + (ML20041B197)
- ML20041B200 + (ML20041B200)
- IR 05000361/1982004 + (ML20041B202)
- ML20041B203 + (ML20041B203)
- ML20041B204 + (ML20041B204)
- 05000255/LER-1982-003, Forwards LER 82-003/03L-0 + (ML20041B205)
- B10407, Confirms Results of Util 820107 Meeting W/Nrc Re Status of SEP for Facility.Integrated Assessment Rept Will Be Submitted During Third Quarter 1982.Schedule for Resolving Open Items Encl + (ML20041B207)
- 05000255/LER-1982-003-03, /03L-0:on 820118,three Hose Stations Were Isolated in Violation of Tech Specs.Caused by Need to Repair Frozen Manual Valve in Fire Supression Sys Piping.Blank Flange Installed on Valve as Temporary Repair + (ML20041B208)
- ML20041B209 + (ML20041B209)
- ML20041B210 + (ML20041B210)
- ML20041B212 + (ML20041B212)
- ML20041B216 + (ML20041B216)
- 05000244/LER-1982-003-01, /01T-0:on 820125,B Generator Experienced Tube Failure.Caused by Axial Burst Rupture of Tube Due to Mechanical Loading Mechanism on Tube 1 Between First Support Plate Tube Sheet.Tube Will Be Plugged + (ML20041B217)
- ML20041B218 + (ML20041B218)
- ML20041B219 + (ML20041B219)
- IR 05000010/1982001 + (ML20041B221)
- IR 05000313/1981032 + (ML20041B222)
- ML20041B223 + (ML20041B223)
- ML20041B224 + (ML20041B224)
- IR 05000266/1981023 + (ML20041B225)
- ML20041B226 + (ML20041B226)
- 05000247/LER-1982-002, Forwards LER 82-002/03L-0 + (ML20041B227)
- ML20041B229 + (ML20041B229)
- ML20041B231 + (ML20041B231)
- 05000247/LER-1982-002-03, /03L-0:on 820110,during Full Power Operation,Weld Channel & Penetration Pressurization Sys Air Consumption Exceeded Tech Spec Limits.Caused by Excessive Seat Leakage in Fischer Valve 1192.Valve Removed & Seat Replaced + (ML20041B232)
- ML20041B233 + (ML20041B233)