Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20033D164 + (ML20033D164)
- IR 05000348/1981024 + (ML20033D165)
- ML20033D166 + (ML20033D166)
- ML20033D167 + (ML20033D167)
- ML20033D168 + (ML20033D168)
- ML20033D169 + (ML20033D169)
- ML20033D170 + (ML20033D170)
- ML20033D173 + (ML20033D173)
- ML20033D175 + (ML20033D175)
- IR 05000348/1981019 + (ML20033D176)
- IR 05000324/1981027 + (ML20033D177)
- ML20033D178 + (ML20033D178)
- AECM-81-469, Interim Deficiency Rept Re Bubbled & Blistered Teflon Coating on Drywell Purge Compressor After Coolers,Initially Reported 811029.Final Rept Expected by 820129.Deficiency Found Not Reportable Per Part 21 + (ML20033D179)
- ML20033D183 + (ML20033D183)
- AECM-81-470, Interim Deficiency Rept Re Unqualified Bettis Air Actuators on Henry Pratt Valves,Initially Reported 811029. Investigation Incomplete.Safety Implications Not Determined. Final Rept Will Be Submitted by 820129 + (ML20033D185)
- ML20033D186 + (ML20033D186)
- ML20033D187 + (ML20033D187)
- ML20033D188 + (ML20033D188)
- ML20033D191 + (ML20033D191)
- ML20033D195 + (ML20033D195)
- ML20033D196 + (ML20033D196)
- ML20033D197 + (ML20033D197)
- IR 05000369/1981023 + (ML20033D199)
- ML20033D200 + (ML20033D200)
- ML20033D201 + (ML20033D201)
- ML20033D202 + (ML20033D202)
- IR 05000413/1981020 + (ML20033D203)
- ML20033D204 + (ML20033D204)
- ML20033D205 + (ML20033D205)
- IR 05000416/1981050 + (ML20033D207)
- ML20033D208 + (ML20033D208)
- ML20033D209 + (ML20033D209)
- ML20033D210 + (ML20033D210)
- ML20033D212 + (ML20033D212)
- IR 05000413/1981023 + (ML20033D213)
- ML20033D214 + (ML20033D214)
- ML20033D215 + (ML20033D215)
- ML20033D217 + (ML20033D217)
- ML20033D218 + (ML20033D218)
- IR 05000338/1981026 + (ML20033D219)
- 05000296/LER-1981-065, Forwards LER 81-065/03L-0 + (ML20033D220)
- ML20033D222 + (ML20033D222)
- ML20033D224 + (ML20033D224)
- 05000296/LER-1981-065-03, /03L-0:on 811031,RCIC Steam Supply Isolation Valve 3-FCV-71-3 Could Not Be Closed Electrically.Caused by Failed Motor Due to Open Field Winding.Will Replace Motor & Submit Results of Evaluation + (ML20033D225)
- ML20033D226 + (ML20033D226)
- IR 05000416/1981047 + (ML20033D227)
- 05000298/LER-1981-023, Forwards LER 81-023/03L-0.Detailed Event Analysis Submitted + (ML20033D228)
- ML20033D230 + (ML20033D230)
- ML20033D231 + (ML20033D231)
- ML20033D232 + (ML20033D232)
- BSEP-81-2223, Ro:Average Release Rate of Offgas from Main Condenser Vacuum Sys from 811109-11 Exceeded Level in Section 2.5.2f of Ets. Caused by Fuel Cladding Deficiencies.Defective Fuel Elements Will Be Replaced + (ML20033D234)