 Issue dateTitleTopic
ML20207M92312 March 1999Amended Part 21 Rept Re Cooper-Bessemer Ksv EDG Power Piston Failure.Total of 198 or More Pistons Have Been Measured at Seven Different Sites.All Potentially Defective Pistons Have Been Removed from Svc Based on Encl Results
ML20207E93126 February 1999Part 21 Rept Re Sprague Model TE1302 Aluminum Electrolytic Capacitors with Date Code of 9322H.Caused by Aluminum Electrolytic Capacitors.Affected Capacitors Replaced
ML20199M08922 January 1999Part 21 Rept Re Failure of Square Root Converters.Caused by Failed Aluminum Electrolytic Capacitory Spargue Electric Co (Model Number TE1302 with Mfg Date Code 9322H).Sent Square Root Converters Back to Mfg,Barker Microfarads,Inc
ML20248F35321 May 1998Part 21 Rept Re Electronic Equipment Repaired or Reworked by Integrated Resources,Inc from Approx 930101-980501.Caused by 1 Capacitor in Each Unit Being Installed W/Reverse Polarity. Policy of Second Checking All Capacitors Is Being AdoptedReverse polarity
ML20140A96629 May 1997Part 21 Rept Re Ksv Emergency Diesel Generator Power Piston Failure.Caused by Jacket Water in Combustion Chamber. Recommends That Users Verify That Crown Thickness at Valve Cutout Be 100 MinimumFinite Element Analysis
ML20137G62625 March 1997Svcs Part 21 Rept Re Emergency Generators Installed at Zion Station Which Developed Significant Drop in Crankcase Lube Oil Level.Caused by Crack in Liner Wall,Allowing Jacket Water to Enter ChamberFinite Element Analysis
ML20117G46414 May 1996Part 21 Rept Re Cooper Bessemer Reciprocating Products,Div of Cooper Cameron Corp,Issued Ltr to Define Utils/Plants Containing Similar Equipment as Supplied on Cooper Bessemer Ksv & Enterprise Dsr EDGs
ML20083R91026 April 1995Final Part 21 Rept Re Kepco,Inc Model RMX24-D-20804 Power Supplies in Which Transistors Q15 &/Or Q16 Failed to Open & R1 Was Open.Replacement of Transmitters w/XSIS-095 Along W/ Replacement of Electrolytic Capacitors Provides Solution
ML20077D34329 November 1994Part 21 Rept Re Suspect Master Connecting Rods & Contains Info Location in Engine for Rods
ML20078G3059 November 1994Rev to Part 21 Rept Re Potential Problem W/Master Power Connecting Rods.Vendor Recommends Listed Utils Perform Visual Insp of Master Rods to Determine Applicability of Rept
ML20058G59817 November 1993Part 21 Rept Re Westronics Recorders,Model 2100C.Signal Input Transition Printed Circuit Board Assembly Redesigned to Improve Recorder Immunity to Electromagnetic Interference.List of Affected Recorders & Locations Encl
ML20057G1517 October 1993Part 21 Rept Re Westronics Model 2100C Series Recorders. Informs That Over Several Tests,Observed That Recorder Would Reset During Peak Acceleration & Door Being Forced Off Recorder.Small Retaining Clips Added to Bottom of Door
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20127P58623 November 1992Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl
ML20043A60927 April 1990Part 21 Rept Re Defective Axial Cracks in Pump Shaft in Region Immediately Above Impeller & in Reactor Recirculation Pumps.Probably Caused by Crack Growth as Thermal Fatigue. Technical Advisory Bulletin Will Be Sent to Each Util
ML20247D30112 July 1989Part 21 Rept 10CFR21-0047 Re Control Wiring Insulation of Inner Jacket Used on General Motors Diesel Generator Sets Identified as 999 or MP Series.Encl List of Owners of Units Notified
ML20246K74026 April 1989Part 21 Rept Re Incorrectly Stamped Name Plates on Certain Asco Nuclear Qualified Valves.Vendor Will Contact Each Affected Facility & Furnish Correctly Stamped Plates & in Near Future Discontinue Sale of Rebuild Kits for Valves
ML20206H72121 November 1988Part 21 Rept Re Defect in Design of Component Mfg by Cooper Energy Svcs.Initially Reported on 881115.Util Became Aware of Problem on 881103.Div I Emergency Diesel Generator Declared Inoperable & Valve Reclassified
ML20207N46412 October 1988Part 21 Rept Re Potential Problem W/Emd 20-645E4,Type 999 Excitation Sys Circuit Breaker & Wiring.Potential for Field Circuit Breaker to Trip Due to Combined Air Temps & Field Current Exists at All Plants W/Model 999 Sys
ML20153B28122 February 1988Part 21 Rept Re Defect in Operation of Gas Monitors Using Fixed Filters.Initially Reported on 880212.Caused by Error in Software for Monitors.Vendor Testing Mod to Software & in Interim Recommends Changing Filters Every 48 H
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20210F8672 February 1987Part 21 Rept Re Use of Improperly Designed S&W Electrical Manhole Duct Seals.Initially Reported on 870123.Manhole Covers Redesigned by S&W to Prevent Flooding of Manhole. Covers Installed Prior to Initial CriticalitySafe Shutdown
ML20209H19831 January 1987Amended Final Deficiency Rept Re Inadequate Flow Rate for Hydrogen Recombiners Supplied by Rockwell.Blower Impeller Orientation for Both Trains Corrected & Tested. Cause of Improper Installation Will Be Submitted by 870213
ML20212Q88626 January 1987Part 21 Rept Re Improper Seating of GE-supplied Agastat GP Series Relays.Defect Attributed to Inadequate Original Installation,Workers Coming in Contact W/Installed Relays or Both.Corrective Actions ListedSafe Shutdown
ML20207J26421 November 1986Interim Deficiency Rept (55(e)-86-22) Re Insufficient Flow Rate for Hydrogen Recombiners.Initially Reported on 861015. Extensive Trouble Shooting During Preoperational Testing Program Underway.Final Rept Will Be Submitted by 861205
ML20215M73723 October 1986Final Deficiency Rept (55(e)-86-21) Re Inadvertent Closure of Automatic Fire Suppression Control Valve.Initially Reported on 860918.Drawing Fsk 23-6c Revised to Change Isolation Valve 2DFR-V128 to Open PositionSafe Shutdown
ML20197B36121 October 1986Final Deficiency Rept (55(e)-86-18) Re Cracked Latching Roller Found on One MSIV & Problems W/Closure Time of Msivs. Initially Reported on 860806 & 15,respectively.MSIVs Capable of Performing Required Design FunctionsFinite Element Analysis
ML20197B03620 October 1986Final Deficiency Rept (55(e)-86-20) Re MSIV Leakage Rates. Initially Reported on 860909.Actions Being Taken to Restore Valves to Acceptable Condition & Reduce Wearing Stress to Acceptable LevelHydrostatic
Liquid penetrant
NMP2L0896, Interim Deficiency Rept 50.55(e)-86-20 Re Excessive Leakage of Msiv.Initially Reported on 860909.Meeting Scheduled for 861015 in Bethesda,Md to Discuss Rept8 October 1986Interim Deficiency Rept 50.55(e)-86-20 Re Excessive Leakage of Msiv.Initially Reported on 860909.Meeting Scheduled for 861015 in Bethesda,Md to Discuss ReptHydrostatic
ML20214T39212 September 1986Interim Deficiency Rept (55(e)86-00-19) Re Failure of MSIV 2MSS*HYV7B to Unlatch & Close within 3-5 as Required by Design.Initially Reported on 860815.Matter Under Investigation.Final Rept Will Be Submitted by 861020
ML20214T31711 September 1986Interim Deficiency Rept 86-00-18 Re Cracked Latch Roller Bearing on MSIV 2MSS*HYV7A.Initially Reported on 860808. Problem Under Investigation.Final Rept Will Be Submitted by 861020
ML20214M3184 September 1986Potential Part 21 Rept Re Contromatics Actuator W/Jackscrew/ Handwheel Emergency Override Operator.Jackscrew/Handwheel Should Be Used for Emergency Manual Operation Only.Encl Ltr Also Sent to Listed Utils/Ae Firms
ML20203M03120 August 1986Final Deficiency Rept (55(e)86-17) Re Cracks in Contact Levers for MSIV Limit Switches (Namco EA180).Initially Reported on 860717.Visual Insp of Contact Levers Performed & Cracked Parts Replaced
ML20215M5278 August 1986Final Deficiency Rept Re Problem W/Response Time of Moderate Energy Line Cracking Temp Sensing Devices.Initially Reported on 860708.W/o Encl
ML20211F7073 August 1986Final Deficiency Rept (55(e)-86-14) Re Control Cable Length Verification.Initially Reported on 860703.Design Changes Issued to Correct Circuits Where Unacceptable Conditions Occurred to Reduce Circuit Resistance of Cables
ML20203D21314 July 1986Part 21 Rept Re Cracks in Plastic Contact Lever Assembly EA188-30007 Found in 14 EA180 Limit Switches During S&W Insp.Replacement of Contact Lever Arms in All Category I safety-related Limit Switches Proposed.Tests Initiated
ML20209G07814 July 1986Part 21 Rept Re Possible Defect in Namco Contact Lever Assembly Part EA188-30007 for Series EA180 Limit Switches. Program Will Be Initiated to Determine If Cracks Caused Switch Failure
ML20207G95314 July 1986Corrected Part 21 Rept Re Cracks in Plastic Contact Lever Assembly EA188-30007 in Series EA180 Limit Switches. Replacement of Contact Lever Arms in All Category I safety-related Limit Switches Proposed.Tests Initiated
ML20215M53910 July 1986Final Deficiency Rept (55(e)-86-11) Re Category I Components in non-Category I Stair Tower.Initially Reported on 860610. Stair Tower Will Be Braced to Resist Seismic Forces Prior to Fuel Load
ML20215M7323 July 1986Final Deficiency Rept (55(e)-86-12) Re Problem W/Air Start Valve Seat Inserts for Div I & II Emergency Diesel Generators.Initially Reported on 860619.Inserts Replaced.Air Start Distributors for Diesels Readjusted
ML20204J0581 July 1986Final Deficiency Rept (55(e)-86-07) Re Excessive Vibrations in Low Pressure Fuel Oil Supply Lines of Div I & II Standby Diesel Generators.Initially Reported on 860508.Damaged Fuel Lines Replaced
ML20206S08430 June 1986Part 21 Rept Re Possible Cut Wires in Wire Harness of Bbc Brown Boveri K600/K800 Circuit Breakers.Initially Reported on 860509.Safety Implications Listed.Gear Guard Designed to Prevent Cut Wires
ML20212D26527 June 1986Forwards Final Deficiency Rept Re Cracks in Delivery Valve Holders for Div I & II Emergency Diesel Generators.Initially Reported on 860528.W/o Encl
ML20211K55720 June 1986Part 21 Rept Re Inadequate Thread Engagement on Motor Hold Down Bolts for Plant Svc Water Sys Pump/Motor,Per NRC .No Further Action Necessary.Customer Initiated Change in Bolt Length
ML20215M54216 June 1986Final Deficiency Rept (55(e)-86-09) Re Borg Warner electro- Hydraulic Actuator Oil Leak on Dc Motor.Initially Reported on 860516.Valves Returned to Mfg & Rebuilt to Include New Seals & Qualified Pao Hydraulic Fluid
ML20215M53510 June 1986Final Deficiency Rept (55(e)-86-08) Re Failure of Elgar Class 1E Inverters Fuse Block Connection.Initially Reported on 860508.Vendor-recommended Mods Which Provide Proper Block to Bar Connection Will Be Completed by 860701
ML20215M7219 June 1986Interim Deficiency Rept (55(e)-86-07) Re Damaged Fuel Lines in Divs I & II Diesel Generators.Initially Reported on 860508.Investigation Continuing.Final Rept Will Be Submitted by 860701
ML20211H3595 June 1986Final Deficiency Rept (55(e)-86-06) Re Rosemount Loose Environ Seal Installations.Initially Reported on 860506. Loose Fittings & All Units w/90-degree Fittings Will Be Modified Prior to Fuel Load
ML20211H4042 June 1986Final Deficiency Rept (55(e)-86-05) Re Incorrect Category I Cable.Initially Reported on 860501.S&W Replaced Unqualified vendor-supplied Cables w/NJP-14 Type Cable for Flow Switches 2HVRKFE/FS 18A & 18C
ML20198E4586 May 1986Deficiency Repts (55(e)-85-00-22) Re Reliance Motors on Limitorque Operators & (55(e)-84-00-48) Re Separation of Cable in Free Air.First Item Not Reportable.Extended Cable Tray Covers Will Be Installed Before Fuel Load