 Issue dateTitleTopic
ML20236P0458 July 1998Part 21 Rept Re non-conformance & Potential Defect in Component of Nordberg Model FS1316HSC Standby Dg.Caused by Outer Spring Valves Mfg from Matl That Did Not Meet Specifications.Will Furnish Written Rept within 60 Days
ML20198J04328 July 1997Update to Amended Interim Part 21 Rept Re Harness/Positive Plate Lug Disconnect on List Ish Round Cell Battery.Requests 7-10 Day Extension to Complete Review
ML20134L10810 October 1996Part 21 Rept Re Defect in Component of Nordberg Model FS1316HSC Sdg.Nak Engineering,Inc Has Established & Adopted Procedures to Assemble Fuel Oil Lines & Climinate Possible Defective Condition
ML20116H2035 August 1996Part 21 Rept Re Potential Defect on Condition in Component of Nordberg Model FS1316HSC Sdg W/Fuel Injection Line Assembly Which Connects Fuel Pump to Injector.Caused by Loose Fuel Line Sleeve
ML20086D9903 July 1995Part 21 Rept Re Two Failures of Model Vtr 500 Turbochargers Supplied by Abb Turbo Systems Ltd.Failure of Turbocharger Renders Associated EDG Incapable of Providing Rated Output. Seventeen Hole Jet Assist Wall Plates ReplacedEnforcement Discretion
Commercial Grade
ML20073S95427 June 1994Part 21 Rept Re Incorrect Matl Supply Discovered on Unshipped Order.Pump Div Will Notify Enertech W/ Recommendation That Items Supplied W/Incorrect Matl Be Removed & Destroyed
ML20070A14422 June 1994Part 21 Rept Re Conditions Which Affect Hydraulic Valve Operators Supplied by Bw/Ip to Enertech Co & Listed Utils. Vendor Will Notify Enertech W/Recommendations That All Items Supplied W/Incorrect Matl Be Removed & Destroyed
ML20126J59631 December 1992Part 21 Rept Re Potential Loss of RHR Cooling During Nozzle Dam Removal.Nozzle Dams May Create Trapped Air Column Behind Cold Leg Nozzle Dam.Mod to Nozzle Dams Currently Underway. Ltrs to Affected Utils EnclHydrostatic
ML20125C7167 December 1992Part 21 Rept Re Possibility for Malfunction of Declutching Mechanisms in SMB/SB-000 & SMB/SB/SBD-00 Actuators. Malfunction Only Occurs During Seismic Event.Balanced Levers May Be Purchased from Vendor.List of Affected Utils EnclStroke time
Anchor Darling
ML20127P58623 November 1992Followup to 921005 Part 21 Rept Re Potential Defect in SB/SBD-1 Housing Cover Screws.Procedure Re Replacement of SBD-1 Spring Cover Bolts Encl.All Fasteners Should Be Loosened & Removed.List of Affected Utils Encl
ET-NRC-92-3707, Part 21 Rept Re Degraded Performance Condition of Westinghouse Protection Sys Overtemp Delta Temp Reactor Trip Function.Issue Not Reportable,Per 10CFR21,based on Diversity of Westinghouse Protection Sys,Per WCAP-730615 June 1992Part 21 Rept Re Degraded Performance Condition of Westinghouse Protection Sys Overtemp Delta Temp Reactor Trip Function.Issue Not Reportable,Per 10CFR21,based on Diversity of Westinghouse Protection Sys,Per WCAP-7306
ML20055E48329 June 1990Part 21 Rept Re Defective Steam Generators Supplied by Westinghouse.Util Will Continue to Rept Any Defects or Other Info Reportable Under 10CFR21 Upon Discovery &/Or During Litigation
ML20043G76422 May 1990Part 21 Rept Re Potential Defect W/Speed Transmitter in Diesel Engine Control Panel of Dsrv Standby Diesel Generator.Estimate of Completion of Corrective Actions Not Possible,Since Correction Made by Other CompaniesOverspeed trip
ML17348A16227 March 1990Part 21 Rept Re Matls W/Programmatic Defects Supplied by Dubose Steel,Inc.Customers,Purchase Order,Items & Affected Heat Numbers Listed
ML19351A2949 October 1989Part 21 Rept Re Potential of Ambient Compensated Molded Case Circuit Breakers to Deviate from Published Info. Instantaneous Trip Check Will Be Instituted on All Class 1E Thermal/Magnetic Ambient Breakers Prior to Shipment
ML20245D9546 September 1988Part 21 Rept Re Condition Involving Inconel 600 Matl Used to Fabricate Steam Generator Tube Plugs & Found to Possess Microstructure Susceptible to Stress Corrosion Cracking
ML20211P72123 February 1987Part 21 Rept Re Rockbestos Coaxial Cable Used in Sorrento Electronics Digital & Analog high-range Radiation Monitor. Insulation Resistance at High Temp Not High Enough for Ion Chamber & Associated Electronics to Operate Properly
ML20214M3184 September 1986Potential Part 21 Rept Re Contromatics Actuator W/Jackscrew/ Handwheel Emergency Override Operator.Jackscrew/Handwheel Should Be Used for Emergency Manual Operation Only.Encl Ltr Also Sent to Listed Utils/Ae Firms
ML20206S08430 June 1986Part 21 Rept Re Possible Cut Wires in Wire Harness of Bbc Brown Boveri K600/K800 Circuit Breakers.Initially Reported on 860509.Safety Implications Listed.Gear Guard Designed to Prevent Cut Wires
ML20137K96010 December 1985Part 21 Rept Re Actuators Having Only One of Required Two Springs Which Could Result in Reduction of Integrity of Reactor Coolant Boundary.Valves Supplied to McGuire Units 1 & 2 & Catawba Unit 2.Catawba Unit 2 Valve Corrected
ML20127E31119 June 1985Part 21 Rept Re Potential Separation of Aluminum Nameplate from Hevi-Duty Type Sbw or Szo Transformers in Nelson Electric Class 1,035-volt Motor Control Ctrs,W/Potential Short Circuit.Initially Reported on 850618
ML20101P20126 December 1984Deficiency & Part 21 Rept Re Quench Cracks Discovered in Sure Loc,Inc ASME Class 2 Hex Nuts.Supplier Notified.Nuts Will Be Replaced as Necessary
ML20091P6778 June 1984Part 21 Rept Responding to Re QA Problems W/Hvac Equipment Mfg by Bahnson Co.Equipment Will Be Reviewed to Determine Deficiencies,Including Catawba & Oconee Air Handling Units
ML20091G20724 May 1984Part 21 Rept Re Bug in Detector Computer Code Resulting in Possible Miscalculation of Tech Spec Parameters for Enthalpy Rise Peaking Factor.Problem Corrected & Responsible Parties Notified
ML20092P66924 May 1984Potential Part 21 Rept Re Bug in Detector Computer Code for in-core Detectors.Bug Incorrectly Calculated Enthalpy Rise Peaking Factor.Bug Corrected
ML20081H4803 November 1983Followup to Part 21 Rept Re Potential Failure of Westinghouse Type SA-1 Relays (IE Info Notice 83-63).Addl Potential Problems Discussed in Encl Ltr Re Tantalum Capacitor Leaking Electrolyte.Not Reportable Per Part 21
ML20081K5201 November 1983Followup Part 21 Rept Re Leaking Tantalum Capacitors in Class IE,SA-1 Relays (Ref IE Info Notice 83-63).Customers Given Option of Returning Relays or Performing Field Mod
ML20070C76310 December 1982Part 21 Rept Re Problem W/Brown Boveri Electric,Inc Low Voltage Circuit Breakers W/Solid State Trip Devices.Units from San Onofre 2 & 3 Failed Due to long-term Degradation of Filter Capacitor C205.Suspect Trip Units Should Be Tested
ML20069D54713 September 1982Interim Deficiency Rept Re Rotork Model NA-2 Electric Motor Switch Problems.Initially Reported on 820623.Clear Plastic Switches on Unit 1 Replaced.Unit 2 Switch Replacement Scheduled.Also Reported Per Part 21Eddy Current Testing
ML20054C08614 April 1982Part 21 Rept Re Airlock Door Seals Presenting Potential Safety Problem.Seals Should Not Be Used After Startup W/O Recertification.Seals Will Be Replace If Approved Test & Insp Program Cannot Be Developed
ML20005B45529 June 1981Part 21 Rept Re Failure of Presray Inflatable Seal Located on Personnel Air Lock.Cause Under Investigation
ML19343C50717 March 1981Significant Deficiency Rept 369-370/80-02 Re Steam Generator narrow-range Level Transmitter Cable Failure to Meet Environ Qualification Requirements.Cable in Unit 1 for Steam Generator Level Transmitters Replaced in Aug 1980
ML20003A33228 January 1981Advises That Corrective Actions Re Significant Deficiency Repts 50-369/80-20 & 50-369/80-21 Have Been Completed for Mode 6 Sys.Remaining Sys Will Be Completed by 810301
ML20002E1489 January 1981Suppl 1 to Significant Deficiency Repts SD 369/80-21 & 370/ 80-16 Re Failure to Consider Containment Vessel Dynamic Movements Due to Postulated Loca,Initially Reported 801126. Analysis Revised
ML19343B81517 December 1980Forwards Supplemental Response to Significant Deficiency Repts SD 369/80-18 & 370/80-13 Re Defective Coils in Valcor Solenoid Valves,Per NRC 801114 Request.Coils in Valves of Sys Required for Fuel Loading Will Be Replaced by 810109
ML19345C33426 November 1980Deficiency Rept Re Improper Loads Used for Support/Restraint Design (Loca,Valve Discharge,Mismatch).Comprehensive Program Initiated to Identify Support/Restraints Affected,Revise Design Sketches & Perform Hardware ChangesEarthquake
ML19345C48626 November 1980Significant Deficiency Repts SD 369/80-21 & SD 370/80-16 Re LOCA Pressure Effects Not Considered in Analysis of Piping W/Cold Penetrations Initially Reported 801031.Comprehensive Program Initiated to Correct Problems
ML19345C48526 November 1980Significant Deficiency Repts SD 369/80-20 & SD 370/80-15 Re Improper Loads for Design of Pipe Support/Restraints Initially Reported 801028.Comprehensive Program Initiated to Correct Problems
ML19343B49918 November 1980Part 21 Rept Re Improper Operation of E-max Isolator Part Number 1750115.Single Channel Isolators 1750141 & 1750115 Will Be Changed Out W/Part 1750146
ML19343A65514 November 1980Significant Deficiency Repts 369/80-19 & 370/80-14 Re Review of Piping Affecting Pipe Rupture Environ in Vital Equipment Areas.Main Steam Drain Lines Not Considered for Pipe Rupture Effects
ML20002A24930 October 1980SD-369/80-18 & 370/80-18:on 800930,Valcor Solenoid Valves V70900-21-3 Failed.Caused by Coil Failure Due to Incompatibility Between Polyimide Magnet Wire Insulation & Polyvinyl Butyral Binding Agent.All Coils to Be Replaced
ML19344B39610 October 1980Deficiency Repts SD 369/80-17 & 370/80-12 Re Improper Operation of E-max Instruments,Inc Model 175C141 Optical Isolator When Driving Loads W/Greater than 1 Amp Inrush Current.Parts Will Be Replaced W/Model 175C146
ML20008E3418 October 1980Part 21 Rept Re Brand Rex Conductor.Absence of Cured Conductor Results in Unqualified Class IE Equipment. Verification of All Current & Future Components Has Been Implemented
ML19338E61726 September 1980Deficiency Rept Re Possible Overvoltage During Ground Faults of Potential Transformers/Cables Connected to Diesel Generators.Potential Transformers Will Be Replaced W/ phase-to-phase & open-delta Connected Transformers
ML19338E07818 September 1980Significant Deficiency Rept SD 369/80-15:on 800917, Pressurizer Cavity Exceeded Design Temp.Caused by Insufficient Ventilation Cooling Flow & Higher than Design Heat Loads.Permanent Temp Monitoring Sys Will Be Installed
ML19331D94528 August 1980Significant Deficiency Rept Re Loose Impeller Cap & Jam Nuts on RHR Pump 1A.Caused by Inadequacy of IR Recommendation Re IE Circular 79-19.Util Has Informed I-R That Recommendation Will Not Resolve Problem
ML19344D93218 August 1980Deficiency Rept SD 369/80-13 Re Mechanical Shock Arrestors Damaged During Installation.Arrestors Have Been Functionally Checked.Damaged Arrestors Have Been Replaced.Insp Procedures Revised to Require Functional Check
ML19344E03412 August 1980Suppl to Significant Deficiency Repts SD 369/80-07 & 370/80-06 Re Inadequate Min Flow Through Centifugal Charging Pumps.Westinghouse Evaluated Impact of Operating Procedure Mods.Interim Mod II Implemented for Corrective Action
ML19338C63211 August 1980Significant Rept SD 369/80-11 Re Valve Operator Orientation. Review of ASME Code Class 1,2 & 3 & Util Class F Valve Power Operator Orientations Revealed Several Valves Erected Outside Design Tolerances.Stds Being Revised
ML19331B9497 August 1980Deficiency Rept Re Defective Coil Leads on Valcor Solenoid Valves Model V70900-21-3.Vendor Insp Revealed One Valve Failed by Magnet Wire Shorting Solenoid Housing.Second Valve Start Wire Lead Joint Touching Windings.Valves Replaced