Deficiency & Part 21 Rept Re Quench Cracks Discovered in Sure Loc,Inc ASME Class 2 Hex Nuts.Supplier Notified.Nuts Will Be Replaced as Necessary
ML20101P201
Person / Time
Site: McGuire, Mcguire  Duke Energy icon.png
Issue date: 12/26/1984
From: Tucker H
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-84, REF-PT21-85-008-000 PT21-85-008-000, PT21-85-8, NUDOCS 8501070061
Download: ML20101P201 (2)


Text

. .

b DUKE Powna Goxiwxy ' VStum %;g P.O. HOK G3180 c.

OHAMLOT TE, N.O. 28242 ' ' /SGfa .[

HAL B. TUCKER h $m,,,,oy

-- m ar-December 26, 1984 MC g 4 8,*

Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Altanta, Georgia 30323

Subject:

McGuire Nuclent Station Docket Nos. 50-369, -370 10 CFR Part 21 Notification

Dear Mr. O'Reilly:

Pursuant to 10 CFR Part 21, and confirming a telephone call on December 21, 1984 with Virgil Brownlee, Duke Power Company hereby reports a component defect which could be a safety hazard:

(i) Name and address of the individual or individuals informing the Commission.

R. L. Gill 422 South Church Street Charlotte, North Carolina (ii) identification of the facility, the activity, or the basic component supplied for such activity within the United States which fails'to comply or contains a defect.

McGuire Nuclear Station Component: ASME Class 2, SA 194 2H, Hex Nuts, 1" Heat # - 33292 ID# - NDS (iii) Identification of the firm constructing the facility or supplying the basic component which fails to comply or contains a defect.

Supplier: Sure Loc Inc.

2302 Dunavant Street Charlotte, N. C. 28203 (iv) Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

Visual indication and subsequent metallurgica10FFICIAC COPY evaluation of quench cracks. ,

85010 61 841226 [ '

1D pDR ADOCK 05000369 S PDR

/p),.- - - - - - -

. , , - Mr. Jcmet P. O'Railly, R gionti Adcinistrator December 26, 1984 Page 2 (v) The date on which the information of such defect or failure to comply was obtained.

December 20, 1984 (vi) In the case of a basic component which contains a defect or fails to comply, the number and location of all such components in use at, supplied for, or being supplied for one or more facilities or activities subject to the regulations in this part.

' Lot of 500 supplied to Duke under P0 E56766-73 Disposition is under investigation.

(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of. time that has been or will ,

be taken to complete the action.

Notify supplier.

Determine distribution within Duke.

Replace as necessary.

Time taken to complete actions is unknown.

(viii) Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or licensees.

No advice will be given to purchaser or licensees. Duke will advise supplier of defective material.

Very truly yours, ,

hb. V lhg Hal B. Tucker RLG/mjf cc: Mr. W. T. Orders NRC Resident Inspector

.McGuire Nuclear Station Mr. Darl Hood U. S. Nuclear Regulatory Commission Region 11 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 i