PLA-5574, November 2002 Monthly Operating Report for Susquehanna Steam Electric Station
ML023610188 | |
Person / Time | |
---|---|
Site: | Susquehanna ![]() |
Issue date: | 12/13/2002 |
From: | Richard Anderson Susquehanna |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
PLA-5574, R41-2A | |
Download: ML023610188 (7) | |
Text
't I i Richard L. Anderson PPL Susquehanna, LLC Vice President - Nuclear Operations 769 Salem /Boulevard Berwick, PA 18603 Tel. 570.542.3883 Fax 570.542.1504 RLAnderson @pplweb corn
- TM December 13, 2002 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Station OPI-17 Washington, D.C. 20555 SUSQUEHANNA STEAM ELECTRIC STATION MONTHLY OPERATING REPORTS Docket Nos. 50-387/NPF-14 and 50-3881NPF-22 PLA-5574 R41-2A The November 2002 Monthly Operating Reports for Susquehanna SES Units I and 2 are attached.
Very truly yours, JJHI/cmm cc: NRC Region 1 NRC Sr. Resident Inspector, Mr. S. Hansell NRC Sr. Project Manager, Mr. T. G. Colburn NRC Project Manager, Mr. E. M. Thomas
OPERATING DATA REPORT DOCKET NO. 50-387 UNIT One DATE 12/13/02 COMPLETED BY J. J. Hennings TELEPHONE (570) 542-3747 OPERATING STATUS
- 1. Unit Name: Susquehanna Steam Electric Station (U 1)
- 2. Reporting Period: November 2002
- 3. Design Electrical Rating (Net MWe): 1115
- 4. Maximum Dependable Capacity (Net MWe): 1105 This Month Yr.-to-Date Cumulative
- 5. Hours in Reporting Period 720 8,016 170,785
- 6. Number of Hours Reactor Was Critical 720 6,818.3 141,120.5
- 7. Hours Generator On-Line 720 6,749.8 138,909.8
- 8. Unit Reserve Shutdown Hours 0 0 0
- 9. Net Electrical Energy Generated (MWH) 801,384 7,194,733 142,421,642 NOTES:
Page 1 of 1
UNIT SHUTDOWNS DOCKET NO. 50-387 UNIT One DATE 12/13/02 COMPLETED BY J. J. Hennings TELEPHONE (570) 542-3747 REPORT MONTH November 2002 No. Date Type Duration Reason Method of Cause & Corrective Action I (Hours) 2 Shutting To Prevent Recurrence Down Reactor 3 No Shutdowns this month.
Summary: The only significant power change during November was a reduction to 82% for a control rod sequence exchange on 11/23102.
I1. 2. 3.
F. Forced Reason: Method:
S. Scheduled A - Equipment Failure (Explain) 1 - Manual B - Maintenance or Test 2 - Manual Scram C - Refueling 3 - Automatic Scram D - Regulatory Restriction 4 - Continuation from previous month E - Operator Training & Licensee Exam 5 - Other F - Administrative G - Operational Error (Explain)
Page 1 of I
SUSQUEHANNA STEAM ELECTRIC STATION Docket Number: 50-387 Dale: 12/13/02 Completed by: J. J. Hennings Telephone: (570) 542-3747 Challenjes to Main Steam Safety Relief Valves None.
OPERATING DATA REPORT DOCKET NO. 50-388 UNIT Two DATE 12/13/02 COMPLETED BY J. J. Hennings TELEPHONE (570) 542-3747 OPERATING STATUS
- 1. Unit Name: Susquehanna Steam Electric Station (U2)
- 2. Reporting Period: November 2002
- 3. Design Electrical Rating (Net MWe): 1117
- 4. Maximum Dependable Capacity (Net MWe): 1111 This Month Yr.-to-Date Cumulative
- 5. Hours in Reporting Period 720 8016 ,156,025
- 6. Number of Hours Reactor Was Critical 720 7,748.4 135,405.4
- 7. Hours Generator On-Line 720 7,696 0 ,133,462.7
- 8. Unit Reserve Shutdown Hours 0 0 0
- 9. Net Electrical Energy Generated (MWH) 802,039 8,479,103 139,283,933 NOTES:
Page 1 of 1
UNIT SHUTDOWNS DOCKET NO. 50-388 UNIT Two DATE 12/13/02 COMPLETED BY J. J. Hennings TELEPHONE (570) 542-3747 REPORT MONTH November 2002 No. Date Type Duration Reason Method of Cause & Corrective Action 1 (Hours) 2 Shutting to Prevent Recurrence Down Reactor 3
No shutdowns in November.
Summary: A control rod sequence exchange was performed on 11/02/02, at 83% power. Power reductions of approximately 10% were conducted for control rod adjustments on 11/9, 11/16 and 11/30.
- 1. 2. 3.
F. Forced Reason: Method:
S. Scheduled A - Equipment Failure (Explain) 1 - Manual B - Maintenance or Test 2 - Manual Scram C - Refueling 3 - Automatic Scram D - Regulatory Restriction 4 - Continuation from previous month E - Operator Training & Licensee Exam 5 - Other F - Administrative G - Operational Error (Explain)
Page 1 of 1
SUSQUEHANNA STEAM ELECTRIC STATION Docket Number: , 50-388 Datei 12/13/02 Completed by: J. J. Hennings Telephone: (570) 542-3747 Challenges to Main Steam Safety Relief Valves None.