NRC 2004-0121, Registration of NUHOMSR-32PT Casks WNHOMS-32-017 and WNHOMS-32-018

From kanterella
(Redirected from NRC 2004-0121)
Jump to navigation Jump to search
Registration of NUHOMSR-32PT Casks WNHOMS-32-017 and WNHOMS-32-018
ML043360236
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 11/22/2004
From: Koehl D
Nuclear Management Co
To:
Document Control Desk, NRC/NMSS/SFPO
References
+sispmjr200506, FOIA/PA-2005-0236, NRC 2004-0121
Download: ML043360236 (3)


Text

Point Beach Nuclear Plant NMI Committed to NlearExcelle Operated by Nuclear Management Company, LLC November 22, 2004 NRC 2004-0121 10 CFR 72.212 ATTN: Document Control Desk Director, Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 Point Beach Nuclear Plant, Units 1 and 2 Dockets 50-266, 50-301, and 72-005 License Nos. DPR-24 and DPR-27 Registration of NUHOMSR-32PT Casks WNHOMS-32-017 and WNHOMS-32-018 In accordance with the requirements of 10 CFR 72.212(b)(1)(ii), Nuclear Management Company, LLC, is providing the enclosed information to register the use of two approved spent fuel storage casks at the Point Beach Nuclear Plant (PBNP) Independent Spent Fuel Storage Installation (ISFSI).

This letter contains no new commitments and no revisions to existing commitments.

Dennis L. Koehl Site Vice-President, Point Beach Nuclear Plant Nuclear Management Company, LLC Enclosure cc: Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW 6610 Nuclear Road

  • Two Rivers, Wisconsin 54241-9516 .-M Telephone: 920.755.2321
  • Fax: 920.755.6233 NOlu

- Document Control Desk Page 2 bcc: J. F. Becka L. H. Bohn J. W. Connolly D. E. Cooper H. J. Kocourek (OSRC) T. Holt D. L. Koehl F. D. Kuester (P460) S. L. Leblang K. M. Locke (2) J. H. McCarthy G. C. Packard J. G. Schweitzer J. D. Shaw J. J. Walsh File D. A. Weaver (P346) E. J. Weinkam III

ENCLOSURE I CASK REGISTRATION INFORMATION Licensee's Name: Nuclear Management Company, LLC Licensee's Address: 700 First Street, Hudson, WI 54016 Reactor License Nos.: DPR-24 and DPR-27 Reactor Docket Nos.: 50-266 and 50-301 ISFSI Docket No.: 72-005 Cask Certificate No.: 1004 Cask Model No.: NUHOMS-32PT

Contact:

J. F. Becka Project Manager (920) 755-7500 Cask Horizontal Dry Shielded Dry Shielded Date Identification Storage Canister Canister Placed Number Number Number Heat Load in Service WNHOMS-32-017 WHSM-001 WDSC-32-001 14.237 kW November 2, 2004 WNHOMS-32-018 WHSM-002 WDSC-32-002 15.192 kW November 13, 2004 Page 1 of I