Integrated Inspection Report 05000382/2024002
ML24215A277
Person / Time
Site: Waterford 
Issue date: 08/08/2024
From: John Dixon
NRC/RGN-IV/DORS/PBD
To: Sullivan J
Entergy Operations
References
IR 2024002
Download: ML24215A277 (21)


Text

August 8, 2024

SUBJECT:

WATERFORD STEAM ELECTRIC STATION, UNIT 3 - INTEGRATED INSPECTION REPORT 05000382/2024002

Dear Joseph Sullivan:

On June 30, 2024, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Waterford Steam Electric Station, Unit 3. On July 17, 2024, the NRC inspectors discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.

One finding of very low safety significance (Green) is documented in this report. This finding involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.

If you contest the violation or the significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:

Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; the Director, Office of Enforcement; and the NRC Resident Inspector at Waterford Steam Electric Station, Unit 3.

If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; and the NRC Resident Inspector at Waterford Steam Electric Station, Unit 3. This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, John L. Dixon, JR, Chief Reactor Projects Branch D Division of Operating Reactor Safety Docket No. 05000382 License No. NPF-38

Enclosure:

As stated

Inspection Report

Docket No.

05000382

License No.

NPF-38

Report No.

05000382/2024002

Enterprise Identifier:

I-2024-002-0007

Licensee:

Entergy Operations Inc.

Facility:

Waterford Steam Electric Station, Unit 3

Location:

Killona, LA 70057

Inspection Dates:

April 1, 2024, to June 30, 2024

Inspectors:

D. Childs, Resident Inspector

N. Greene, Senior Health Physicist

J. O'Donnell, Senior Health Physicist

A. Sanchez, Senior Project Engineer

C. Speer, Project Manager

Approved By:

John L. Dixon, Jr., Chief

Reactor Projects Branch D

Division of Operating Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an integrated inspection at Waterford Steam Electric Station, Unit 3, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

Failure of Auxiliary Component Cooling Water Pump Motor a During Oil Sample Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000382/2024002-01 Open/Closed

[H.12] - Avoid Complacency 71152A The inspectors reviewed a self-revealed Green finding and associated non-cited violation of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix B, Criterion V,

Instructions, Procedures, and Drawings, for failure to provide adequate guidance and instructions when taking an oil sample from an operating pump motor which caused a bearing failure and the pump to become inoperable.

Additional Tracking Items

None.

PLANT STATUS

Waterford, Unit 3, began the inspection period in shutdown in Mode 5 due a plant trip from a fire in main transformer B on March 21, 2024. The unit remained shutdown in Mode 5 until Waterford made the decision to start up the plant and operate with only main transformer A available; however, this constraint limited reactor power to 53 percent. Plant startup commenced on May 7, 2024, reaching Mode 1 on May 14, 2024, and 53 percent power on May 16, 2024. The unit remained in Mode 1 at 53 percent until down powering to 18 percent power and taking the main turbine offline to complete the replacement of main transformer B on June 9, 2024. The unit remained in Mode 1 at 18 percent power until replacement and testing of main transformer B was completed on June 14, 2024. Replacement transformer B is reduced in capacity and constrains reactor power to approximately 94 percent. Waterford, Unit 3, commenced raising power from 18 percent on June 14, 2024, and achieved 93 percent power on June 15, 2024. On June 16, 2024, an automatic trip occurred due to a lightning strike that caused an electrical perturbation that resulted in inadvertent trip signals being sent to the plants core protection calculators. The unit remained in Mode 3 until commencing plant startup on June 19, 2024, reaching Mode 1 on June 19, 2024, and 94 percent power on June 20, 2024. The unit remained at 94 percent power due to the reduced capacity of main transformer B for the remainder of the inspection period.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors performed activities described in IMC 2515, Appendix D, Plant Status, observed risk significant activities, and completed on-site portions of IPs. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

REACTOR SAFETY

71111.01 - Adverse Weather Protection

Seasonal Extreme Weather Sample (IP Section 03.01) (1 Sample)

(1) The inspectors evaluated readiness for seasonal extreme weather conditions prior to the onset of seasonal hot temperatures for the following systems: ultimate heat sink, emergency diesel generator system, and safety related switchgears on May 29, 2024.

Impending Severe Weather Sample (IP Section 03.02) (1 Sample)

(1) The inspectors evaluated the adequacy of the overall preparations to protect risk -significant systems from impending severe weather and tornadic conditions on April 9, 2024.

71111.04 - Equipment Alignment

Partial Walkdown Sample (IP Section 03.01) (1 Sample)

The inspectors evaluated system configurations during partial walkdowns of the following systems/trains:

(1)emergency diesel generator A and 4160kv switchgear A while emergency diesel generator B was inoperable due to an emergent turbocharger issue on June 27, 2024

Complete Walkdown Sample (IP Section 03.02) (1 Sample)

(1) The inspectors evaluated system configurations during a complete walkdown of the essential chilled water system on April 30, 2024.

71111.05 - Fire Protection

Fire Area Walkdown and Inspection Sample (IP Section 03.01) (4 Samples)

The inspectors evaluated the implementation of the fire protection program by conducting a walkdown and performing a review to verify program compliance, equipment functionality, material condition, and operational readiness of the following fire areas:

(1)fire areas ROOF E-001 and W-001, elevation +46.00' reactor containment building roof on April 15, 2024 (2)fire areas NS-TB-001 and -002, elevation +15.00' turbine building east and west on May 8, 2024 (3)fire area FHB-001, elevations -35.00' to +46.00' fuel handling building on June 3, 2024 (4)fire area RAB 20-001, elevation +21.00' reactor auxiliary building component cooling water pump AB on June 7, 2024

71111.07A - Heat Exchanger/Sink Performance

Annual Review (IP Section 03.01) (1 Sample)

The inspectors evaluated readiness and performance of:

(1) auxiliary component cooling water system trains A and B

71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance

Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01) (2 Samples)

(1) The inspectors observed and evaluated licensed operator performance in the control room during startup activities on May 14, 2024.
(2) The inspectors observed and evaluated licensed operator performance in the control room during grid sync on June 16, 2024.

Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)

(1) The inspectors observed and evaluated operator training in the simulator for feedwater control and reactor trip override systems, and the new standing order to mitigate effects of an identified deficiency in the feedwater control system on April 17, 2024.

71111.12 - Maintenance Effectiveness

Maintenance Effectiveness (IP Section 03.01) (2 Samples)

The inspectors evaluated the effectiveness of maintenance to ensure the following structures, systems, and components (SSCs) remain capable of performing their intended function:

(1)auxiliary component cooling water system train B after failure of the auxiliary component cooling pump B on May 24, 2024 (2)essential chilled water trains A and B following multiple issues challenging operability on June 13, 2024

71111.13 - Maintenance Risk Assessments and Emergent Work Control

Risk Assessment and Management Sample (IP Section 03.01) (3 Samples)

The inspectors evaluated the accuracy and completeness of risk assessments for the following planned and emergent work activities to ensure configuration changes and appropriate work controls were addressed:

(1)yellow risk due to reactor coolant system drain down to mid-loop with fuel in the core to remove a seal on reactor coolant pump 2A on April 12, 2024 (2)yellow risk due to reactor coolant system drain down to mid-loop with fuel in the core to install a new seal on reactor coolant pump 2A on April 16, 2024 (3)elevated risk due to emergent turbocharger maintenance on emergency diesel generator B the week of June 24, 2024

71111.15 - Operability Determinations and Functionality Assessments

Operability Determination or Functionality Assessment (IP Section 03.01) (2 Samples)

The inspectors evaluated the licensee's justifications and actions associated with the following operability determinations and functionality assessments:

(1)safety related Rosemount transmitters operability determination after issues with environmental qualifications were identified through Entergy operating experience (2)excore nuclear instrument channel C operability determination after observed erratic behavior on May 14, 2024

71111.18 - Plant Modifications

Temporary Modifications and/or Permanent Modifications (IP Section 03.01 and/or 03.02) (1 Sample)

The inspectors evaluated the following temporary or permanent modifications:

(1)temporary modification EC-0054128322 to provide a temporary offsite power source to the safety-related 4.16kv bus 2B due to the loss of startup transformer B on April 12, 2024

71111.20 - Refueling and Other Outage Activities

Refueling/Other Outage Sample (IP Section 03.01) (1 Sample)

(1) The inspectors evaluated refueling outage 25 activities from April 1 to May 14, 2024, which completes the partial sample documented in Waterford Inspection Report 05000382/2024001, section 71111.20.

71111.24 - Testing and Maintenance of Equipment Important to Risk

The inspectors evaluated the following testing and maintenance activities to verify system operability and/or functionality:

Post-Maintenance Testing (PMT) (IP Section 03.01) (1 Sample)

(1)shield building ventilation system train A following replacement of a faulty contactor and performance of preventative maintenance activities associated with pressure and temperature loops on May 20, 2024

Surveillance Testing (IP Section 03.01) (5 Samples)

(1)local leak rate surveillance testing of reactor containment building equipment hatch on April 24, 2024 (2)emergency diesel generator A loaded run surveillance test on April 29, 2024 (3)safety injection actuation signal train B surveillance test on May 22, 2024 (4)safety injection actuation signal train A surveillance test on May 30, 2024 (5)containment spray pump A surveillance test on June 10, 2024

Inservice Testing (IST) (IP Section 03.01) (2 Samples)

(1)safety injection tank 1A discharge check valve quarterly inservice testing on April 25, 2024 (2)emergency feedwater train A flow control valve quarterly inservice testing on June 3, 2024

Diverse and Flexible Coping Strategies (FLEX) Testing (IP Section 03.02) (1 Sample)

(1) Operational testing of the N diesel generator on May 15,

RADIATION SAFETY

71124.01 - Radiological Hazard Assessment and Exposure Controls

Radiological Hazard Assessment (IP Section 03.01) (1 Sample)

(1) The inspectors evaluated how the licensee identifies the magnitude and extent of radiation levels and the concentrations and quantities of radioactive materials and how the licensee assesses radiological hazards.

Instructions to Workers (IP Section 03.02) (1 Sample)

(1) The inspectors evaluated how the licensee instructs workers on plant-related radiological hazards and the radiation protection requirements intended to protect workers from those hazards.

Contamination and Radioactive Material Control (IP Section 03.03) (2 Samples)

The inspectors observed/evaluated the following licensee processes for monitoring and controlling contamination and radioactive material:

(1)licensee surveys of potentially contaminated material leaving the radiologically controlled area (RCA)

(2)workers exiting the RCA at Unit 1 during a forced outage period

Radiological Hazards Control and Work Coverage (IP Section 03.04) (4 Samples)

The inspectors evaluated the licensee's control of radiological hazards for the following radiological work:

(1)radiation work permit (RWP) 20240304, Forced Outage - Minor Maintenance Activities, task 1, to work on decontaminating the flash tank room below a contamination area, on the -4-foot elevation of the reactor auxiliary building (RAB)

(2)contamination controls for workers exiting the Unit 1 containment (3)radiation protection staff surveying items as workers exit the Unit 1 containment (e.g. camera and tools)

(4) RWP 20240304, task 1, to work on checking high pressure safety injection valve leakage in a contaminated area outside of containment High Radiation Area and Very High Radiation Area Controls (IP Section 03.05) (5 Samples)

The inspectors evaluated licensee controls of the following high radiation areas (HRAs) and very high radiation areas (VHRAs):

(1) HRA - spent resin tank pump room on the -35-foot elevation of the RAB
(2) HRA - south letdown heat exchanger valve gallery on the -4-foot elevation of the RAB
(3) HRA - purification ion exchanger rooms A and B on the -4-foot elevation of the RAB
(4) HRA - process shield #1 in the radwaste solidification building
(5) HRA - boric acid pre-concentration filter cubicles A and B on the -35-foot elevation of the RAB Radiation Worker Performance and Radiation Protection Technician Proficiency (IP Section 03.06) (1 Sample)
(1) The inspectors evaluated radiation worker and radiation protection technician performance as it pertains to radiation protection requirements.

71124.04 - Occupational Dose Assessment

Source Term Characterization (IP Section 03.01) (1 Sample)

(1) The inspectors evaluated licensee performance as it pertains to radioactive source term characterization.

External Dosimetry (IP Section 03.02) (1 Sample)

(1) The inspectors evaluated how the licensee processes, stores, and uses external dosimetry.

Internal Dosimetry (IP Section 03.03) (1 Sample)

The inspectors evaluated the following internal dose assessments:

(1) The inspectors reviewed the internal dose assessment records of a facial contamination.

Special Dosimetric Situations (IP Section 03.04) (1 Sample)

The inspectors evaluated the following special dosimetric situations:

(1) The inspectors reviewed the records for three declared pregnant workers.

OTHER ACTIVITIES - BASELINE

===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:

MS05: Safety System Functional Failures (SSFFs) Sample (IP Section 02.04)===

(1) April 1, 2023, through March 31, 2024

MS06: Emergency AC Power Systems (IP Section 02.05) (1 Sample)

(1) April 1, 2023, through March 31, 2024

MS07: High Pressure Injection Systems (IP Section 02.06) (1 Sample)

(1) April 1, 2023, through March 31, 2024

OR01: Occupational Exposure Control Effectiveness Sample (IP Section 02.15) (1 Sample)

(1) July 1, 2023, through March 31, 2024 PR01: Radiological Effluent Technical Specifications/Offsite Dose Calculation Manual Radiological Effluent Occurrences (RETS/ODCM) Radiological Effluent Occurrences Sample (IP Section 02.16) (1 Sample)
(1) July 1, 2023, through March 31, 2024

71152A - Annual Follow-up Problem Identification and Resolution Annual Follow-up of Selected Issues (Section 03.03)

The inspectors reviewed the licensees implementation of its corrective action program related to the following issues:

(1)ground trucks used in resistance testing for safety related pumps providing inaccurate results on June 13, 2024 (2)auxiliary component cooling water pump B bearing failure on June 28,

INSPECTION RESULTS

Failure of Auxiliary Component Cooling Water Pump Motor A During Oil Sample Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000382/2024002-01 Open/Closed

[H.12] - Avoid Complacency 71152A The inspectors reviewed a self-revealed Green finding and associated non-cited violation of Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for failure to provide adequate guidance and instructions when taking an oil sample from an operating pump motor which caused a bearing failure and the pump to become inoperable.

Description:

On August 31, 2023, mechanics were attempting to collect an oil sample from the running pump motor bearing oil reservoir of auxiliary component cooling water (ACCW)pump A using a manual suction pump in accordance with OP-002-001, Auxiliary Component Cooling Water, revision 320. This had been a common, routine, licensee maintenance practice. During this time, the mechanics withdrew approximately 20-30 ml of the required 100 ml of oil from the motor oil reservoir, when the mechanics encountered problems with the manual suction pump. The mechanics left the jobsite to retrieve another pump. Work order 53035401 did not include any notes or cautions warning the mechanics about leaving the oil level lower than normal and they failed to recognize the need to add the amount of oil they had removed back into the oil reservoir.

While the mechanics were acquiring a new suction pump, motor bearing temperature started increasing steadily over the next 15 minutes. The main control room received a high vibration alarm at 9:17 a.m. on ACCW pump A inboard motor bearing. Operations tried to reset the alarm which did not reset. The main control room dispatched a non-licensed auxiliary operator to investigate. Upon arrival, a grumbling sound was heard that had not existed during normal rounds. A sheen of oil was observed on the inboard motor casing, pedestal, and floor. There was no visible oil level in the motor inboard bearing sight glass. Control room operators secured the pump at 9:33 a.m. Operators observed no coast down of the motor when the pump was secured, as it came to an immediate stop. The licensee entered the action statement for Technical Specification 3.7.3 declaring the ACCW A pump inoperable.

Following replacement of the pump motor, ACCW pump A was declared operable on September 4, 2023.

2 of fleet procedure EN-DC-310, Predictive Maintenance Program, revision 12, states that an individual trained in oil sampling techniques should obtain the oil sample, or adequate work instructions should be provided. Maintenance and operations training at each site in conjunction with Predictive Maintenance, determines the level of training and qualification required to perform oil sampling. Waterford made the decision to take all oil samples on running motors without recognizing that small reservoir motors were at higher risk for damage due to minimal oil being available to keep the bearing lubricated during the sampling process.

Section 4.1.3 of fleet procedure EN-MA-106, Planning, revision 6, states, that the planner is responsible for developing work packages in accordance with this procedure that ensure error-free maintenance and maintain design. Additionally, this procedure states that the planner is responsible for ensuring work instruction level of detail is consistent with the training and qualification program for the minimum qualified worker and/or skill of the craft.

Work order 53035401, used for acquiring the ACC pump A motor bearing oil sample, did not provide sufficient information to acquire the oil sample safely, without subjecting the pump motor to a potentially detrimental condition. With no information or cautions in the work order related to the concern of removing oil from the motor bearings for a prolonged period, the mechanics were unaware of the consequences. Removing a quantity of oil from the motor bearings without immediately replacing the oil was not recommended and could prove destructive to the motor bearings. Specifically, the mechanics did not recognize that they were to remove 100 ml from a 250 ml oil reservoir; they did not recognize that removing 20-30 ml of oil for a prolonged time of 15 minutes would attribute to bearing temperature rise and failure. Additionally, engineering, who controls the engineering owned oil sample Preventive Maintenance, failed to understand the risk of removing oil while the motor was running. Following consultation, the vendor recommended that the site stop taking oil samples while the equipment is running; instead, secure the equipment, immediately take the oil sample, replace the oil, then return to service.

Corrective Actions: Incorporate into work order documents to stop certain motors prior to taking future oil samples. Also, engineering will review and provide better guidance for taking oil samples. Training was performed on this event with the new requirement of securing certain motors prior to taking oil samples.

Corrective Action References: condition report CR-WF3-2023-15311

Performance Assessment:

Performance Deficiency: The inspectors determined that the failure to have adequate instructions in the work order for withdrawing an oil sample from an operating pump motor was a performance deficiency. Specifically, the licensee failed to provide work instructions that appropriately indicated the risks involved with removing oil from an operating safety related pump motor bearing or appropriate actions to mitigate that risk.

Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the Equipment Performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the ACCW pump motor failed due to the licensee not providing sufficient training or instructions to adequately take an oil sample from an operating pump motor.

Significance: The inspectors assessed the significance of the finding using Inspection Manual Chapter 0609 Appendix A, The Significance Determination Process (SDP) for Findings At-Power. The inspectors determined the finding was of very low safety significance (Green)because the finding was a deficiency affecting the design or qualification of a mitigating structure, system, or component (SSC) and the SSC maintained its operability or functionality.

Cross-Cutting Aspect: H.12 - Avoid Complacency: Individuals recognize and plan for the possibility of mistakes, latent issues, and inherent risk, even while expecting successful outcomes. Individuals implement appropriate error reduction tools. Specifically, the licensee failed to consider the potential impacts of removing oil from the bearing of running pump for an extended period.

Enforcement:

Violation: Title 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, states, Activities affecting quality shall be prescribed by documented instructions, procedures, or drawings, of a type appropriate to the circumstances and shall be accomplished in accordance with these instructions, procedures, or drawings. Instructions, procedures, or drawings shall include appropriate quantitative or qualitative acceptance criteria for determining that important activities have been satisfactorily accomplished.

Contrary to the above, prior to August 31, 2023, instructions, procedures, or drawings did not include appropriate quantitative or qualitative guidance to safely accomplish the acquisition of an oil sample from a running, safety related motor, without causing the motor to fail.

Specifically, the skill of the craft training, and instructional guidance in work order 53035401 for safely removing an oil sample from a running, operational, safety related motor was inadequate to prevent failure of the motor.

Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.

Minor Performance Deficiency 71152A Minor Performance Deficiency Minor Performance Deficiency: The inspectors identified a minor performance deficiency for failure to provide adequate induction motor testing procedures. Specifically, licensee procedures ME-004-330, 4kV Induction Motor Testing, and ME-004-340, 7kV Induction Motor Testing, did not include resistance checks on ground trucks prior to use for motor testing. It was found that the ground trucks used in resistance testing were providing low resistance values which made test results appear worse than actual. For example, component cooling water pump B degraded from 698 MOhms to 69 MOhms between the 2019 to 2022 tests.

Testing results still met minimum acceptance criteria; however, these results make the pumps insulation appear to be degrading faster than actuality in the Motor Component Monitoring Program (i.e., conservatively).

Screening: The inspectors determined the performance deficiency was minor. The inspectors determined the performance deficiency to be minor because the inaccurate resistance values provided were conservative in nature and made pump insulation appear to be degrading faster than actuality; therefore, there were no instances for which actual insulation degradation remained undetected.

Significance: The inspectors assessed the significance of the finding using Inspection Manual Chapter 0609 Appendix A, The Significance Determination Process (SDP) for Findings At-Power. This failure to provide an adequate procedure constitutes a minor performance deficiency that is not subject to enforcement action in accordance with the NRCs Enforcement Policy. The licensee generated condition report CR-WF3-2023-13327 to address this issue in their corrective action program.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On May 10, 2024, the inspectors presented the occupational radiation safety inspection results to Joseph Sullivan, Site Vice President, and other members of the licensee staff.
  • On July 17, 2024, the inspectors presented the integrated inspection results to Joseph Sullivan, Site Vice President, and other members of the licensee staff

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.01

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

24-02759

71111.01

Miscellaneous

WT-WF3-2023-

2011757

24 Summer Reliability Plan

07/17/2023

71111.01

Procedures

EN-FAP-WM-016

Seasonal Reliability

71111.04

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

24-01046, 2023-18122, 2023-17856, 2023-17628

71111.04

Procedures

OP-002-004

Chilled Water System

25

71111.04

Procedures

OP-009-002

Emergency Diesel Generator

360

71111.05

Fire Plans

FHB-001

Fuel Handling Building

71111.05

Fire Plans

NS-TB-001

Turbine Building Ground Floor +15.00 East

71111.05

Fire Plans

NS-TB-002

Turbine Building Ground Floor +15.00 West

71111.05

Fire Plans

RAB 20-001

Component Cooling Water Pump A/B

71111.05

Fire Plans

ROOF E-001

Reactor Containment Building +46.00' Elevation

71111.05

Fire Plans

ROOF W-001

Reactor Containment Building +46.00' Elevation

71111.07A

Engineering

Changes

EC-0054003619

Relaxation of Thermal Performance Testing Frequency for

ACCW System per GL 89-13 Requirements

71111.07A

Miscellaneous

ER-W3-2001-

25-000

CCW Monitoring Plan

71111.07A

Miscellaneous

ER-W3-2001-

25-001

CCW Monitoring Plan Clarifications

71111.07A

Procedures

CE-002-003

Maintaining Auxiliary Component Cooling Water Chemistry

2

71111.11Q

Procedures

OP-003-033

Main Feedwater

330

71111.11Q

Procedures

OP-003-035

Auxiliary Feedwater

313

71111.11Q

Procedures

OP-010-003

Plant Startup

366

71111.11Q

Procedures

OP-901-521

Severe Weather and Flooding

343

71111.12

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

24-01345, 2024-01290, 2024-01083, 2024-01905,

24-00219, 2024-00092, 2023-17500, 2023-17164,

23-017150

71111.12

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

23-17150, 2023-17164, 2023-17500, 2024-01743

71111.12

Procedures

EN-DC-205

Maintenance Rule Monitoring

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.13

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

24-01755, 2024-02020

71111.13

Procedures

EN-OM-132

Nuclear Risk Management Process

71111.13

Procedures

EN-OP-119

Protected Equipment Postings

71111.13

Procedures

PLG-009-014

Control of Outages

21

71111.13

Work Orders

54127178, 54127227, 54127271

71111.15

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

24-01097, 2024-01706, 2024-00994

71111.15

Miscellaneous

LPL-EQA-8.1A

Environmental Qualification Assessment on Rosemount

Transmitters Type 1152 Used in the Waterford SES Unit No.

71111.15

Miscellaneous

LPL-EQMI-08.01

Rosemount Model 1153 Series A, B & D, 1154 & 1154

Series H Transmitters and 1159 Remote Seals

71111.15

Miscellaneous

TD-R369.0140

Rosemount 1153 Series B Aphaline Nuclear Pressure

Transmitter Reference Manual 4302

71111.15

Miscellaneous

W3-DBD-012

Design Basis Document Plant Protection System

71111.15

Procedures

OP-500-009

Control Room Cabinet K

71111.18

Engineering

Changes

EC-0054128117

Temporary Power 4AB to 2B Bus

71111.18

Engineering

Changes

EC-0054128322

Temp Power Source for 4.16kv bus 2B

71111.18

Engineering

Changes

FCR-54132262

Testing Requirement Changes to EC-54128322

71111.18

Procedures

EN-DC-136

Temporary Modifications

71111.24

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

24-02319

71111.24

Miscellaneous

FIG-001

FLEX Implementing Guide

71111.24

Procedures

OP-009-002

Emergency Diesel Generator

360

71111.24

Procedures

OP-903-029

Safety Injection Actuation Signal Test

71111.24

Procedures

OP-903-033

Cold Shutdown IST Valve Tests

71111.24

Procedures

OP-903-069

Emergency Diesel Generator and Subgroup Relay

Operability Verification

27

71111.24

Procedures

OP-903-121

Safety Systems Quarterly IST Valve Tests

71111.24

Procedures

STA-001-004

Local Leak Rate Testing

20

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71111.24

Work Orders

54136059, 54127437, 54127242, 54081318, 53019766,

54122234

71124.01

ALARA Plans

RWP 20230705

Refuel 25 - Reassembly of Reactor Head and Associated

Work Activities including Staging/Destaging of Equipment

01/24/2024

71124.01

Corrective Action

Documents

CR-WF3-YYYY-

XXXXX

22-07357, 2023-16223, 2023-16474, 2023-16822,

23-17095, 2023-17230, 2023-17690, 2023-17984,

23-18161, 2023-18463, 2024-00699

71124.01

Miscellaneous

High Radiation Area, Locked High Radiation Area, & Very

High Radiation Area Weekly Checklist

05/12/2024

71124.01

Miscellaneous

Personnel Contamination Events Log

05/06/2024

71124.01

Procedures

EN-NF-200

Special Nuclear Material Control

71124.01

Procedures

EN-RE-220

PWR Control of Miscellaneous Material in the Spent Fuel

Pool

71124.01

Procedures

EN-RP-100

Radiation Worker Expectations

71124.01

Procedures

EN-RP-101

Access Control for Radiologically Controlled Areas

71124.01

Procedures

EN-RP-102

Radiological Control

71124.01

Procedures

EN-RP-106

Radiological Survey Documentation

71124.01

Procedures

EN-RP-108

Radiation Protection Posting

71124.01

Procedures

EN-RP-109

Hot Spot Program

71124.01

Procedures

EN-RP-110

ALARA Program

71124.01

Procedures

EN-RP-121

Radioactive Material Control

71124.01

Procedures

EN-RP-122

Alpha Monitoring

71124.01

Procedures

EN-RP-131

Air Sampling

71124.01

Procedures

UNT-005-014

Offsite Dose Calculation Manual

309

71124.01

Radiation

Surveys

WF3-2403-00087

-35 Reactor Auxiliary Building Spent Resin Tank Pump

Room, Waste Condensate IX

03/13/2024

71124.01

Radiation

Surveys

WF3-2403-00202

-4 Reactor Containment Building

03/26/2024

71124.01

Radiation

Surveys

WF3-2403-00219

-11 Reactor Containment Building

03/26/2024

71124.01

Radiation

Surveys

WF3-2404-00012

Reactor Auxiliary Building -35, Boric Acid Pre-Concentrator

Filters

04/01/2024

71124.01

Radiation

Surveys

WF3-2404-00076

Radwaste Solidification Building

04/05/2024

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71124.01

Radiation

Surveys

WF3-2404-00085

Monthly Survey of +46 Fuel Handling Building

04/05/2024

71124.01

Radiation

Surveys

WF3-2405-00005

-4 Reactor Auxiliary Building

05/01/2024

71124.01

Radiation

Surveys

WF3-2405-00038

-4 Reactor Auxiliary Building Flash Tank/Purification Filter

Area Monthly Survey

05/03/2024

71124.01

Radiation

Surveys

WF3-AS-101823-

275

+46 Unit 1 Reactor Containment Building Upper Cavity

10/18/2023

71124.01

Radiation

Surveys

WF3-AS-101823-

276

+46 Unit 1 Reactor Containment Building Cavity, General

Area, Disassembly

10/18/2023

71124.01

Radiation

Surveys

WF3-AS-110623-

0788

-11 Reactor Containment Building, Work on Reactor Coolant

Pump Heat Exchanger

11/06/2023

71124.01

Radiation Work

Permits (RWPs)

230510

RF25 - Install/Remove Steam Generator Nozzle Dams

Verification and Closeout

71124.01

Radiation Work

Permits (RWPs)

230515

Remove/Install RCP 1A Motor, RCP Seal, Rotating Baffle,

RCP Heat Exchanger

71124.01

Radiation Work

Permits (RWPs)

240011

Restricted Tours, Inspections, and Work Activities in the

Radiologically Controlled Area (RCA)

71124.01

Radiation Work

Permits (RWPs)

240306

Forced Outage - Minor Maintenance Activities (including

scaffold and insulation), Operation task, Walkdowns,

Surveillances and Inspections, Sampling, RP,

Processing/Shipping, Various Decon

71124.01

Self-Assessments LO-WLO-2022-

00086 CA-00001

Radiological Hazard Assessment and Exposure Controls

2/06/2024

71124.04

ALARA Plans

23-0515 Post

Job Review

Removal/Install RCP 1A Motor, RCP Seal, Rotating Baffle,

RCP Heat Exchanger

04/29/2024

71124.04

ALARA Plans

23-0610 In

Progress Review

Refuel 25 - Erect/Dismantle Scaffolding in the Reactor

Containment Building

11/08/2023

71124.04

ALARA Plans

23-0708 Post

Job Review

Refuel 25 - Heater Junction Thermocouple (2) and Stinger

(3) Replacement Work Activities

11/10/2023

71124.04

ALARA Plans

23-2027

Station 5-Year Exposure Reduction Plan

2/01/2022

71124.04

Calibration

Records

FastScan

Calibration of the Mirion Fast Scan WBC System

04/12/2024

71124.04

Corrective Action

CR-WF3-YYYY-

23-15263, 2023-16223, 2023-16822, 2023-16873,

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Documents

XXXXX

23-16898, 2023-17095, 2023-17324, 2023-17598,

23-017690, 2023-17787, 2023-17796, 2023-017802,

23-17861, 2024-01751, 2024-01912

71124.04

Corrective Action

Documents

Resulting from

Inspection

CR-HQN-YYYY-

XXXXX

24-00572, 2024-02504

71124.04

Engineering

Evaluations

WF-AS-110123-

0634

Dose Assessment for an Uptake on 11/01/2023

11/13/2023

71124.04

Miscellaneous

Personnel Contamination Log

23

71124.04

Miscellaneous

100518-0

NVLAP Accreditation Certificate

01/01/2024

71124.04

Miscellaneous

23

DLR Monitoring Period Established Background

04/24/2024

71124.04

Miscellaneous

L103525

Report of Analysis/Certificate of Conformance

2/29/2023

71124.04

Miscellaneous

WF3-RPT-2-001

2 Dry Fuel Storage Neutron Dosimetry Evaluation

01/13/2020

71124.04

Miscellaneous

WF3-RPT-20-002

Waterford 3 2019 Fourth Quarter Background Subtraction

Study

04/27/2020

71124.04

Miscellaneous

WF3-RPT-21-004

Waterford 3 Plant Characterization

11/04/2021

71124.04

Procedures

EN-RP-110

ALARA Program

71124.04

Procedures

EN-RP-122

Alpha Monitoring

71124.04

Procedures

EN-RP-131

Air Sampling

71124.04

Procedures

EN-RP-152

Conduct of Radiation Protection

71124.04

Procedures

EN-RP-201

Dosimetry Administration5

71124.04

Procedures

EN-RP-202

Personnel Monitoring

71124.04

Procedures

EN-RP-203

Dose Assessment

71124.04

Procedures

EN-RP-204

Special Monitoring Requirements

71124.04

Procedures

EN-RP-205

Prenatal Monitoring

71124.04

Procedures

EN-RP-208

Whole Body Counting / In-Vitro Bioassay

71124.04

Procedures

EN-RP-503

Selection, Issue and Use of Respiratory Protection

Equipment

71124.04

Radiation

Surveys

RF25

RF 25 Post Outage ALARA Report

71124.04

Radiation

Surveys

WF3-AS-103123-

0579

Particulate Sample Report

10/31/2023

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71124.04

Radiation

Surveys

WF3-AS-103123-

0580

Lapel Sample Report

10/31/2023

71124.04

Radiation

Surveys

WF3-AS-103123-

0581

Lapel Sample Report

10/31/2023

71124.04

Radiation

Surveys

WF3-AS-110123-

0637

Particulate Sample Report

11/01/2023

71124.04

Radiation

Surveys

WF3-AS-110123-

0638

Lapel Sample Report

11/01/2023

71124.04

Radiation

Surveys

WF3-AS-110123-

0643

Particulate Sample Report

11/01/2023

71124.04

Radiation

Surveys

WF3-AS-110123-

0644

Lapel Sample Report

11/01/2023

71124.04

Radiation

Surveys

WF3-AS-110123-

0646

Lapel Sample Report

11/01/2023

71124.04

Radiation Work

Permits (RWPs)

23-0511 Post

Job Review

RF25 Perform Eddy Current Work/Tube Plugging

04/15/2024

71124.04

Self-Assessments LO-WLO-2022-

00086-00001

IP 71124.04 Occupational Dose Assessment

2/01/2024

71151

Miscellaneous

W3F1-2023-0032

Annual Radioactive Effluent Release Report (ARERR) 2022

with Revised ODCM

04/27/2023

71151

Procedures

EN-RP-113

Response to Contaminated Spills/Leaks

71152A

Corrective Action

Documents

CR-HQN-YYYY-

NNNN

CR-HQN-2023-03094

71152A

Corrective Action

Documents

CR-WF3-YYYY-

NNNN

23-13327, 2023-14263, 2023-17142, 2023-17522,

23-17528, 2023-17934, 2023-18508, 2024-00276,

24-01357, 2008-00421, 2023-15311

71152A

Engineering

Changes

EC-54076164

LPSI A - Input to Operability

71152A

Procedures

EN-DC-310

Predictive Maintenance Program

71152A

Procedures

EN-DC-310

Predictive Maintenance Program

71152A

Procedures

EN-FAP-LI-001

Performance Improvement Review Group (PRG) Process

71152A

Procedures

EN-WM-100

Work Order Generation, Screening and Classification

71152A

Procedures

FLP-MMT1-LUBE

Training Material Title: Lubrication

71152A

Procedures

ME-004-330

4kV Induction Motor Maintenance

307

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71152A

Procedures

ME-004-330

4kV Induction Motor Maintenance

306

71152A

Procedures

ME-004-340

7kV Induction Motor Maintenance

307

71152A

Procedures

ME-004-340

7kV Induction Motor Maintenance

306

71152A

Procedures

UNT-005-007

Plant Lubrication Program

307

71152A

Work Orders

53030774, 53034053, 54058512, 584014, 54047113,

53035401-01, 54046166-29