DECREE No. 379 of 7th November 2016 concerning the approval of some products in the field of peaceful use of nuclear energy and ionising radiation and the carriage of radioactive or fissile material The State Office for Nuclear Safety stipulates, pursuant to § 236 of Act No 263/2016 Coll.,
the Atomic Act towards the implementation of § 9(4)(a) and (b), § 24(7), § 137(6),
§ 138(6)(a) to (c), § 141(3) and § 143(4):
§ 1 Subject matter This decree incorporates relevant Euratom regulations1) and regulates the type approval of certain products in the field of the peaceful use of nuclear energy and ionising radiation and the carriage of radioactive or fissile material.
§ 2 Definitions For the purposes of this implementing decree, the following definitions apply:
a) the value A1 is the value of activity of special form radioactive material listed in Table 2 of Annex 3 to this decree, or stipulated pursuant to Points 3 to 7 of Annex 3 to this decree, and used to stipulate activity limits for purposes of carriage; b) the value A2 is the value of activity of an other than special form radioactive material listed in Table 2 of Annex 3 to this decree, or stipulated pursuant to Points 3 to 7 of Annex 3 to this decree, and used to stipulate activity limits for purposes of carriage; c) a package is packaging with its radioactive content; d) a confinement system is the organisation of fissile material in packaging or the organisation of part of packaging in a manner necessary to control criticality; e) a containment system is the organisation of part of packaging in a manner necessary to prevent the escape of the radioactive or fissile material during transport; f) a freight container is a device for the carriage of packaged or unpackaged products via one or more modes of transport without the handling of individual items of its contents that has a permanent closure, is sufficiently durable for repeated use and has equipment that permits its handling, especially its transfer among means of transport from one mode of transport to another; freight containers are broken down into
- 1. small container with all external dimensions of less than 1.5 m or with an internal volume of less than 3 m3;
- 2. intermediate bulk container for unpackaged substances or items, which is mechanical portable container whose resistance to stress during handling and transport is verified by testing, and with an internal volume of no greater than 3 m3;
- 1)
Council Directive 2006/117/Euratom of 20 November 2006 on the supervision and control of shipments of radioactive waste and spent fuel.
Commission Decision 2008/312/Euratom of 5 March 2008, establishing the standard document for the supervision and control of shipments of radioactive waste and spent fuel referred to in Council Directive 2006/117/Euratom.
- 3. large container, which is any container not meeting the definitions in Points 1 and 2; g) an overpack is a protective case used by one carrier as one handling unit to facilitate the transport of one or more packages; h) a consignment is all packages or packagings or a load of radioactive or fissile substances handed over by the carrier for transport; i) exclusive use is the use of a conveyance or large container by one carrier, whose instructions govern all loading and unloading activity during the entire course of carriage; j) a low specific activity material is a radioactive material whose own specific activity is naturally limited, or a radioactive material whose mean specific activity has been intentionally limited; k) a low toxicity radionuclide source emitting alpha radiation (hereinafter a low toxicity alpha emitter) is natural uranium, depleted uranium, natural thorium, 235U, 238U, 232Th, 228Th, and 230Th contained in ores or in physical or chemical concentrates, or other radionuclide sources emitting alpha radiation (hereinafter alpha emitter) with transformation half-lives of less than 10 days; l) maximum normal operating pressure is the maximum overpressure that can occur in a retention system over the course of one year at a temperature and sunlight corresponding to ambient conditions during transport, assuming no ventilation, external cooling via an auxiliary system, or operating check during transport occur; m) a surface contaminated object is a solid object that is not itself radioactive but which has radioactive or fissile material distributed on its surface; n) unirradiated thorium is thorium containing not more than 10-7 g 233U per gram of 232Th; o) unirradiated uranium is uranium containing not more than 2.103 Bq of plutonium per gram of 235U, at most 9.106 Bq of fission products per gram of 235U, and at most 5.10-3 g 236U per gram of 235U; p) uranium
- 1. natural uranium, including chemically separated uranium, containing uranium isotopes in the following distribution: approximately 99.28 % by mass of 238U, approximately 0.72 % by mass of 235U, and an insignificant mass percentage of 234U;
- 2. depleted uranium with a smaller mass percentage of 235U than natural uranium; depleted uranium also contains an insignificant mass percentage of 234U;
- 3. enriched uranium with a higher mass percentage of 235U than 0.72 %; enriched uranium also contains an insignificant mass percentage of 234U; q) routine conditions of carriage are conditions during which no radiation emergency occurs; r) normal conditions of carriage are conditions during which a radiation emergency simulated by tests pursuant to Points 19 to 25 of Part II of Annex 1 to this decree occurs; s) accident conditions of carriage are conditions during which a radiation emergency simulated by tests pursuant to Points 26 to 37 of Part II of Annex 1 to this decree occurs.
§ 3 Carriage of a radioactive or fissile material requiring authorisation, classification of radioactive or fissile material and requirements imposed on radioactive or fissile material (Re § 9(4)(a) and (b) of the Atomic Act)
(1) Carriage requiring authorisation pursuant to § 9(4)(a) or (b) of the Atomic Act is carriage of
a) fissile material if the sum of the criticality safety indices of packages in one conveyance or shipping container is greater than 50; b) nuclear fuel; c) a package containing special form radioactive material with activity greater than 3.103 A1, radioactive material other than special form with activity greater than 3.103 A2 or radioactive material with activity greater than 1 000 TBq, depending on which of these values is lower; d) radioactive or fissile material in packaging of Type B(M) that is not designed for a temperature range of minus 40 ºC to plus 70 ºC or that is designed to permit occasional controlled ventilation; and e) radioactive or fissile material via a vessel intended for this purpose with a specified radiation protection programme.
(2) Carriage requiring authorisation pursuant to § 9(4)(a) or (b) of the Atomic Act, and in the case of international carriage also authorisation of the relevant authority of the state that the carriage concerns, is carriage of a) radioactive or fissile material containing radionuclides whose values of A1 and A2 not listed in Table 2 of Annex 3 to this decree were stipulated by calculation pursuant to Points 3 to 7 of Annex 3 to this decree; b) radioactive or fissile material contained in an instrument or product and containing radionuclides whose values for a package exception listed in column 5 of Table 2 of Annex 3 to this decree were replaced by values calculated according to principles and methods stipulated in Annex 6 to this decree; and c) fissile substances pursuant to Point 17(f) of Annex 3 to this decree.
(3) Classification of radioactive or fissile substances and packages and requirements imposed on them are provided in Points 1 and 8 to 34 of Annex 3 to this decree, and in Part I of Annex 1 to this decree.
§ 4 Packaging for the carriage, storage or deposit of radioactive or fissile material (Re § 9(4)(a) and (b) of the Atomic Act)
(1) Requirements for specification of the type of packaging for the transport of radioactive or fissile material, depending on the radioactive content of the package, are stipulated in Annex 3 to this decree.
(2) Types of packaging for the carriage of a radioactive or fissile material and corresponding packages are as follows:
a) packaging for a package exception and a package exception; b) Type IP-1 packaging and a Type IP-1 industrial package; c) Type IP-2 packaging and a Type IP-2 industrial package; d) Type IP-3 packaging and a Type IP-3 industrial package; e) Type A packaging and a Type A package; f)
Type B(U) packaging and a Type B(U) industrial package; g) Type B(M) packaging and a Type B(M) industrial package; h) Type C packaging and a Type C industrial package.
(3) Packaging for the transport of radioactive material that is not fissile material must, depending on its type, meet the requirements of Part I of Annex 1 to this decree, as follows:
a) every packaging must meet the requirements of Points 7 to 18 and of Points 19 to 21, if it is intended for air carriage; b) packaging for package exceptions must meet the requirements of Point 22; c) Type IP-1, IP-2, and IP-3 packaging must meet the requirements of Points 23 to 30; d) packaging for the transport of 0.1 kg or more of uranium hexafluoride must meet the requirements of Points 31 to 33, or of Point 34; e) Type A packaging must meet the requirements of Points 35 to 51; f)
Type B(U) packaging must meet the requirements of Points 52 to 66; g) Type B(M) packaging must meet the requirements of Points 67 and 68; and h) Type C packaging must meet the requirements of Points 69 to 72.
(4) Packaging for the transport of fissile material must, depending on its type, meet the requirements of (3)(a) to (h) and the requirements of Points 73 to 86 of Part I of Annex 1 to this decree. The requirements of Points 73 to 86 of Part I of Annex 1 to this decree do not apply to packages in a consignment containing only fissile material that meets the requirements of one of (a) through (f) of Point 17 of Annex 3 to this decree (hereinafter exceptions of fissile material).
(5) Type S packaging for the storage of radioactive or fissile material and type D packaging for the deposit of radioactive or fissile material must, depending on its type, meet the requirements of Annex 2 to this decree.
§ 5 Requirements regarding the content of documentation for authorisation of carriage of radioactive or fissile material (Re § 24(7) of the Atomic Act)
Documentation for authorisation of carriage of radioactive or fissile material contained in an instrument or product, and containing radionuclides for which values for excepting a package have been replaced by values calculated according to the principles and methods stipulated in Annex 6 to this decree, must for the purpose of the calculation of individual dosages for a transport worker and a representative individual, and collective dosages under routine conditions of carriage, normal conditions of carriage and under accident conditions of carriage, contain data on a) the expected use of the device or product and the radionuclides it contains; b) the maximum activity of the radionuclides contained in the device or product; c) the maximum radiation level on the surface and at a distance of 1 m from the device or product; d) the chemical and physical form of the radionuclides contained in the device or product; e) the design of the device or product, especially the containment system and radiation shielding for the radionuclides contained in the device or product; f) the management system used, including quality control, and that the device or product is manufactured according to the design type specifications; g) verification procedures to ensure that radionuclide activity and absorbed dose equivalent limits declared for the device or product are not exceeded, and h) the maximum number of devices or products that are to be shipped in one consignment, annually.
§ 6 The method of stipulating and maximum permissible values of the transport index (TI), the criticality safety index, unfixed contamination and absorbed equivalent dose, and the manner in which the package category is specified (Re § 141(3)(a) of the Atomic Act)
(1) The method for determining a) the transport index for a package, an overpack, a freight container, unpackaged material with low mass activity in group LSA-I, or an unpackaged surface contaminated item in group SCO-I is stipulated in Points 23 and 24 of Annex 4 to this decree; b) the criticality safety index for
- 1. a consignment, a freight container and an overpack are stipulated in Point 25 of Annex 4 to this decree; and
- 2. a package is stipulated in Points 84 to 86 of Part I of Annex 1 to this decree; and c) a package category is stipulated in Points 29 of Annex 4 to this decree.
(2) The maximum permissible values for the transport index, criticality safety index, and radiation level on the surface and at a given distance from it for a package, an overpack, and a conveyance are stipulated in Points 26 to 28, 66 to 69, and 73 of Annex 4 to this decree.
(3) The maximum permissible non-fixed contamination values for a package, an overpack, and a conveyance are stipulated in Points 8, 9, 13, and 14 of Annex 4 to this decree.
§ 7 Technical and organisational conditions of carriage and transport of radioactive or fissile material (Re § 141(3)(b) of the Atomic Act)
(1) Technical and organisational conditions that must be fulfilled a) prior to the initial and prior to every further carriage of radioactive or fissile material are stipulated in Points 1 to 3 of Annex 4 to this decree; b) to secure the carriage of individual package types are stipulated in Points 4 to 22 of Annex 4 to this decree; c) for the safe separation of packages, overpacks or containers containing radioactive or fissile material and some radioactive material from transport workers, the population, unexposed photographic film, and other dangerous items during carriage and stowage are stipulated in Points 62 and 63 of Annex 4 to this decree; d) for the safe placement of a consignment of packages on or in the means of transport and during stowage are listed in Points 64 to 67 of Annex 4 to this decree; and e) for the safe mutual separation of groups of packages containing fissile material during carriage and during stowage are listed in Points 68 to 70 of Annex 4 to this decree.
(2) Further requirements to ensure safe carriage are stipulated in Annex 4 to this decree, and if they apply to a) carriage documents and marking in general, in Points 45 to 61; b) carriage via rail and road, in Points 71 to 74; c) carriage via vessels, in Points 75 and 76; d) carriage via air, in Points 77 to 79; e) carriage via post, in Point 80;
f) other essentials of carriage, in Points 81 to 88.
§ 8 Requirements regarding the content, language and availability of documentation required for the carriage and transport of radioactive or fissile material (Re § 141(3)(c) of the Atomic Act)
(1) Requirements for a) the essentials of a description of a consignment in a carriage document are stipulated in Point 46 of Annex 4 to this decree; b) carriage documentation are stipulated in Points 47 to 53 of Annex 4 to this decree; and c) documentation and operating rules that the carrier must ensure are available to the consignor are stipulated in Points 54 to 56 of Annex 4 to this decree.
(2) During the cross-border carriage pursuant to § 9(4)(d) of the Atomic Act, documentation accompanying carriage must include also completed relevant standard documents provided in Annex 5 to this decree, specifically during carriage of a) radioactive waste standard documents A-1 and A-4a and also standard document A-5 in case of carriage based on common authorisation for multiple cross-border carriages, and b) spent nuclear fuel standard documents B-1 and B-4a and also standard document B-5 in case of carriage based on common authorisation for multiple cross-border carriages.
§ 9 The manner, scope and deadlines for notifying the administrative authorities for carriage (Re § 141(3)(d) of the Atomic Act)
The manner, scope, and deadlines for notifying a) the Office and the relevant authority of the state that international transport concerns are stipulated in Points 57 to 60 of Annex 4 to this decree; and b) the consignor by the carrier regarding necessary measures for carriage are stipulated in Points 54 to 56 of Annex 4 to this decree.
§ 10 The marking, appearance and method of use of labelling to mark a package, freight container and conveyance for carriage (Re § 141(3)(e) of the Atomic Act)
(1) The marking of a package and overpack with UN numbers and naming pursuant to Table 1 of Annex 3 to this decree is stipulated in Points 30 to 37 of Annex 4 to this decree.
(2) The use of labelling to mark a package, overpack, and freight container is stipulated in Points 38 and 39 of Annex 4 to this decree. The completion of these labels is stipulated in Points 40 to 42 of Annex 4 to this decree.
(3) The use of placards and tables to mark a freight container and conveyance is stipulated in Points 43 and 44 of Annex 4 to this decree.
(4) The appearance and dimensions of the trefoil radioactivity symbol, labels, placards, and tables are stipulated in Figures 1 to 7 of Annex 4 to this decree.
§ 11 Products subject to Product Type Approval (Re § 137(6) of the Atomic Act)
(1) Type approval applies to the following packaging intended for carriage, storage or deposit of radioactive or fissile material, including radioactive waste:
a) Type IP-1, IP-2, IP-3 and A for the carriage of fissile material, aside from excepted fissile material; b) for the carriage of 0.1 kg or more of uranium hexafluoride; in the event of international carriage of radioactive shipments pursuant to Point 34 of Part I of Annex 1 to this decree, type approval by the relevant authority of the state that the carriage concerns is also necessary; c) Type B(U), B(M) and C packaging for the carriage of radioactive or fissile material; in the event of international carriage of Type B(M) radioactive shipments pursuant to Point 67 of Part I of Annex 1 to this decree, type approval by the relevant authority of the state that the carriage concerns is also necessary; d) for the carriage of a radioactive or fissile material requiring multilateral approval pursuant to international treaties by which the Czech Republic is bound; e) Type D intended for the deposit of spent or irradiated nuclear fuel or radioactive waste produced by its reprocessing; and f)
Type S intended for the storage of radioactive or fissile material, including radioactive waste, specifically for special form radioactive material whose activity exceeds A1, or for radioactive material other than special form whose activity exceeds A2.
(2) Special form radioactive material with properties stipulated in Points 2 to 4 of Part I of Annex 1 to the draft decree and low dispersible radioactive material with properties stipulated in Point 5 of Part I of Annex 1 to the draft decree are subject to type approval.
§ 12 Documentation for a type approval application, tests or calculations and analyses and the contents of their documentation (Re § 138(6)(a) and (b) of the Atomic Act)
(1) The scope, contents and performance method of tests or calculations and analyses for a type approval application for special form radioactive material, low dispersible radioactive material or packaging for the carriage, storage or deposit of radioactive or fissile material are stipulated in Part II of Annex 1 to this decree.
(2) Documentation for an application for type approval of special form radioactive material, low dispersible radioactive material or packaging for the carriage, storage or deposit of radioactive or fissile material is product test documentation or documentation of calculations, safety assays and analyses, and their independent verification (hereinafter test documentation). Documentation for a product type approval application comprises, a) for packaging, test documentation pursuant to Points 13 to 37 of Part II of Annex 1 to this decree applicable to the given type of packaging with an evaluation of results in accordance with Points 1 and 2 of Part II of Annex 1 to this decree; evaluation of results
proves compliance with requirements stipulated for the given type of packaging in § 4(3) to (5);
b) for special form radioactive material, test documentation pursuant to Points 4 to 11 of Part II of Annex 1 to this decree with an evaluation of results in accordance with Points 1 and 2 of Part II of Annex 1 to this decree; evaluation of results proves compliance with requirements in Points 2 to 4 of Part I of Annex 1 to this decree; and c) for low dispersible radioactive material, test documentation pursuant to Points 3 and 12 of Part II of Annex 1 to this decree with an evaluation of results in accordance with Points 1 and 2 of Part II of Annex 1 to this decree; evaluation of results proves compliance with the requirements of Point 5 of Part I of Annex 1 to this decree.
§ 13 Requirements for an authorised corporate subject performing tests and independent verification of tests or calculations and analyses for a product type approval application; (Re § 138(6)(c) of the Atomic Act)
(1) A corporate entity that performs tests for type approval of a special form radioactive material, a low dispersible radioactive material or packaging for the transport, storage or deposit of radioactive or fissile material must a) have a facility equipped for the performance of tests pursuant to Part II of Annex 1 to this decree appropriate for the given product type; b) have drawn up procedures for the performance of tests pursuant to Part II of Annex 1 to this decree appropriate for the given product type; c) have workers trained for the performance of tests pursuant to Part II of Annex 1 to this decree appropriate for the given product type; d) have a quality management system in place; and e) be independent of the applicant.
(2) A corporate entity performing calculations and analyses or independent verification of these calculations and analyses instead of tests applicable to a given type of special form radioactive material, low dispersible radioactive material and packaging for the carriage, storage or deposit of radioactive or fissile material must, in accordance with Points 1 and 2 of Part II of Annex 1 to this decree:
a) use a calculation program for such calculations and analyses or independent verification of these calculations and analyses that ensures sufficient precision and accuracy of results; b) must have workers trained to perform the appropriate calculations and analyses or independent verification of these calculations and analyses; c) have a quality management system in place; and d) not be in a dependent relationship with the applicant when performing independent verification of calculations and analyses.
§ 14 Samples of standard documents used in the area of cross-border carriage of radioactive waste or spent nuclear fuel (Re § 143(4) of the Atomic Act)
Samples of standard documents used in the area of cross-border carriage of radioactive waste or spent nuclear fuel are provided in Annex 5 to this decree.
§ 15 Notification This decree was notified in accordance with Directive (EU) 2015/1535 of the European Parliament and of the Council of 9 September 2015 laying down a procedure for the provision of information in the field of technical regulations and of rules on Information Society services.
§ 16 Entry into force This implementing decree shall enter into force on 1st January 2017.
Chairperson:
Ing. Dana Drábová Ph.D., v. r.
Annex 1 to Decree No...
REQUIREMENTS AND TEST PROCEDURES FOR TYPE APPROVAL PART I I.
REQUIREMENTS FOR RADIOACTIVE OR FISSILE MATERIALS, PACKAGINGS, AND PACKAGES I.1. REQUIREMENTS FOR RADIOACTIVE OR FISSILE MATERIALS I.1.1 Requirements for a radioactive material with low specific activity material in group LSA-III
- 1.
A radioactive material with low specific activity in group LSA-III must be a solid material of such a nature that after the entire contents of the package are subjected to the test specified in Point 3 of Part II, the activity of water does not exceed 0.1 A2.
I.1.2 Requirements for special form radioactive material
- 2.
Special form radioactive material must have at least one dimension greater than 5 mm.
- 3.
Special form radioactive material shall be of such a nature or shall be so designed that a) it does not break or shatter under impact or pressure tests pursuant to Points 5 and 6 or pursuant to Point 9(a), and during bending tests pursuant to Point 7 of Part II; b) it does not melt or disperse during heat tests pursuant to Point 8 or 9(b) of Part II; c) the activity of water during the leaching test pursuant to Points 10 and 11 of Part II does not exceed 2 kBq, or for sealed sources, the leakage rate during volumetric leakage assessment test does not exceed the permitted limit pursuant to ISO 9978:1992 (E).
- 4.
When a sealed capsule constitutes part of the special form radioactive material, the capsule shall be so manufactured that it can be opened only by destroying it.
I.1.3 Requirements for low dispersible radioactive material
- 5.
Low dispersible radioactive material shall be such that the total amount of this radioactive material in a package shall meet the following requirements:
a) the radiation level at 3 m from unshielded radioactive material does not exceed 10 mSv/h; b) if subjected to tests specified in Points 36 and 37 of Part II, the airborne release in gaseous and particulate forms of up to 100 m aerodynamic equivalent diameter would not exceed 100 A2; a separate specimen may be used for each test; and c) if subjected to the test specified in Point 3 of Part II, the activity of water would not exceed 100 A2; in the application of this test, the damaging effects of the tests specified in (b) shall be taken into account.
I.1.4 Requirements for exception of fissile material
- 6.
An exceptions of fissile material pursuant to Point 17(f) of Annex 3 to this decree shall be subcritical without the need for accumulation control under conditions a) of Point 73(a);
b) consistent with requirements for assessing a set of packages under normal conditions of carriage pursuant to Point 84(b) and under accident conditions of carriage pursuant to Point 85(b); and c) of Point 83(a) for packages transported by air.
I.2. GENERAL REQUIREMENTS FOR PACKAGINGS AND PACKAGES
- 7.
A package shall be designed so that a) it can be easily and safely transported with regard to its mass, volume, and shape, and b) it can be secured in or on the conveyance during transport.
- 8.
A package shall be designed so that a) any lifting attachments on the package are functional, and if they fail, the fulfilment of other requirements of this decree is not threatened, and b) safety factors for snatch lifting of the package are met.
- 9.
Attachments and any other features on the outer surface of a package that could be used to lift it shall be designed either to support its mass in accordance with the requirements of Point 8. If the requirement in the first sentence is not met, they shall be removable or otherwise rendered incapable of being used during transport.
- 10.
As far as practicable, packaging shall be so designed that the external surfaces are free from protruding features and can be easily decontaminated.
- 11.
As far as practicable, the outer layer of a package shall be so designed as to prevent the collection and retention of water.
- 12.
Equipment carried together with a package shall not reduce its safety.
- 13.
A package shall be capable of withstanding the effects of any acceleration, vibration or vibration resonance that may arise under routine conditions of transport and repeated use so that a) there is no deterioration in the effectiveness of the closing devices on the various receptacles of the package; b) its integrity is not compromised; and c) nuts, bolts and other securing devices do not become loose or fall off.
- 14.
The material of the packaging and any components or structures shall be physically and chemically compatible with each other and with the radioactive contents; changes in their characteristics due to irradiation must also be taken into account.
- 15.
All valves through which the radioactive contents could escape shall be protected against unauthorised operation.
- 16.
The design of the package shall take into account ambient temperatures and pressures that are likely to be encountered in routine conditions of transport.
- 17.
A package shall be so designed that it provides sufficient shielding to ensure that, under routine conditions of transport and with the maximum design activity of its radioactive contents, the radiation level at any point on the external surface of the package does not exceed the values specified in Points 16, 27, and 28 of Annex 4 to this decree, taking into account Points 66(b) and 73 of Annex 4 to this decree.
- 18.
The design of a package must also take into account other properties of radioactive or fissile material pursuant to Point 7 of Annex 4 to this decree.
I.3. ADDITIONAL REQUIREMENTS FOR PACKAGES TRANSPORTED BY AIR
- 19.
For a package to be transported by air, the temperature of the accessible surfaces shall not exceed 50 °C at an ambient temperature of 38 °C with no account taken for insolation.
- 20.
A package to be transported by air shall be so designed that if it is exposed to ambient temperatures ranging from minus 40 °C to plus 55 °C, the integrity of the containment system would not be breached.
- 21.
A package to be transported by air shall be capable of withstanding an internal pressure that produces a pressure differential of not less than maximum normal operating pressure plus 95 kPa, without loss or dispersal of radioactive contents.
I.4. REQUIREMENTS FOR PACKAGE EXCEPTIONS
- 22.
A package exception shall be designed to meet the requirements of Points 7 to 18 and of Points 19 to 21, if carried by air.
I.5. REQUIREMENTS FOR INDUSTRIAL PACKAGES I.5.1. Requirements for Type IP-1
- 23.
A package exception shall be designed to meet the requirements of Points 7 to 18 and 36, and of Points 19 to 21, if carried by air.
I.5.2. Requirements for Type IP-2
- 24.
A Type IP-2 package shall be designed to meet the requirements for Type IP-1 as specified in Point 23, and so that performance of tests in Points 22 and 23 of Part II does not cause:
a) loss or dispersal of the radioactive contents; and b) more than a 20 % increase in the maximum radiation level on an arbitrary location on the external surface of the package.
I.5.3. Requirements for Type IP-3
- 25.
A Type IP-3 package shall be designed to meet the requirements for Type IP-1 as specified in Point 23, and requirements in Points 37 to 49.
I.5.4. Alternative requirements for Type IP-2 and Type IP-3
- 26.
A package may be used as Type IP-2 if:
a) it meets requirements for Type IP-2 specified in Point 23; b) it is designed to meet requirements for UN Packing Group I or II according to the United Nations Recommendations on the Transport of Dangerous Goods, Model Regulations; and c) performance of tests stipulated for UN Packing Group I or II does not result in
- 1. loss or dispersal of the radioactive contents; and
- 2. more than a 20 % increase in the maximum radiation level on an arbitrary location on the external surface of the package.
- 27.
A portable tanks may be used as Type IP-2 or Type IP-3, provided that:
a) it meets requirements for Type IP-1 specified in Point 23; b) it is designed so that
- 1. it meets the requirements of the United Nations Recommendations on the Transport of Dangerous Goods, Model Regulations, or other requirements guaranteeing the same or higher level of protection; and
- 2. is capable of withstanding a test pressure of 265 kPa; and c) is designed so that any additional shielding that is provided
- 1. withstands the static and dynamic stresses resulting from handling and routine conditions of transport; and
- 2. prevents more than a 20 % increase in the maximum radiation level on an arbitrary location on the external surface of the package.
- 28.
Tanks, other than portable tanks, may be used as Type IP-2 or Type IP-3 for transporting LSA-I and LSA-II liquids and gases as prescribed in Table 1 of Annex 4 to this decree, provided that:
a) it meets requirements for Type IP-1 specified in Point 23; b) it is designed so that
- 1. it complies with relevant requirements of the European Agreement concerning the International Carriage of Dangerous Goods by Road (ADR)2)or other requirements guaranteeing the same or greater level of protection; and
- 2. is capable of withstanding a test pressure of 265 kPa; and c) is designed so that any additional shielding that is provided
- 1. withstands the static and dynamic stresses resulting from handling under routine conditions of transport; and
- 2. prevents more than a 20 % increase in the maximum radiation level on an arbitrary location on the external surface of the package.
- 29.
A freight container with the characteristics of a permanent enclosure may be used as Type IP-2 or Type IP-3, provided that:
a) its radioactive contents are restricted to solid material;
- 2)
The European Agreement concerning the International Carriage of Dangerous Goods by Road (ADR),
decreed under No 64/1987, as amended.
b) it meets requirements for Type IP-1 specified in Point 23; and c) it is designed to meet requirements pursuant to ISO 1496:1990(E), except for dimensions and ratings. If subjected to the tests prescribed in the first sentence and to acceleration occurring during routine conditions of transport it would prevent:
- 1. loss or dispersal of the radioactive contents; and
- 2. more than a 20 % increase in the maximum radiation level on an arbitrary location on the external surface of the package.
- 30.
A metal intermediate bulk container may also be used as Type IP-2 or Type IP-3, provided that:
a) it meets requirements for Type IP-1 specified in Point 23; and b) it is designed to meet requirements for UN Packing Group I or II pursuant to the United Nations Recommendations on the Transport of Dangerous Goods -
Model Regulations. If subjected to the tests prescribed in the first sentence, but with the drop test performed with the most damaging orientation of the test container, it would prevent:
- 1. loss or dispersal of the radioactive contents; and
- 2. more than a 20 % increase in the maximum radiation level on an arbitrary location on the external surface of the package.
I.6. REQUIREMENTS FOR PACKAGES CONTAINING URANIUM HEXAFLUORIDE
- 31.
A package intended for the transport of uranium hexafluoride shall meet the requirements that pertain to the radioactive and fissile properties of the transported material. Except as allowed in Point 34, uranium hexafluoride in quantities of 0.1 kg or more shall be packaged and transported in accordance with ISO 7195:2005(E) and the requirements of Points 32 and 33.
- 32.
A package intended for contents of 0.1 kg or more of uranium hexafluoride shall be designed so that it shall:
a) withstand a pressure test specified in Point 18 of Part II without leakage and without unacceptable stress, as specified in ISO 7195:2005(E), except for cases specified in Point 34; b) withstand the free drop test specified in Point 22 of Part II without loss or dispersal of the uranium hexafluoride; and c) withstand the thermal test specified in Point 28 of Part II without rupture of the containment system, except as allowed in Point 34.
- 33.
A package intended for contents of 0.1 kg or more of uranium hexafluoride shall not be equipped with pressure relief devices.
- 34.
A package intended for contents of 0.1 kg or more of uranium hexafluoride that a) is designed to standards other than ISO 7195:2005(E) guaranteeing the same or higher degree of nuclear safety and radiation protection; b) withstands, without leakage and without unacceptable stress, a pressure test specified in point 18 of Part II only at a test pressure less than 2.76 MPa; or c) is designed to contain 9 000 kg or more of uranium hexafluoride and does not meet the requirements of Point 32(c);
may be used for carriage only if its type has been approved by the Office, and in the case of international carriage, also by the relevant authority of the state that the carriage concerns; other requirements in Points 31 to 33 must be fulfilled.
I.7. REQUIREMENTS FOR TYPE A PACKAGES
- 35.
A Type A package shall be designed to meet the requirements of Points 7 to 18, 36 to 51, and requirements of Points 19 to 21, if carried by air.
- 36.
The smallest overall external dimension of the package shall not be less than 10 cm.
- 37.
The outside of the package shall incorporate a feature such as a seal that is breakable with difficulties and which, while intact, will be evidence that the package has not been opened in an unauthorised manner.
- 38.
Any tie-down attachments on the package shall be so designed that, under normal and accident conditions of transport, the forces in those attachments shall not impair the ability of the package to meet the requirements of this decree.
- 39.
The design of the package shall take into account temperatures ranging from -
40 °C to +70 °C for the components of the packaging. Special attention shall be given to freezing temperatures for liquids and to the potential degradation of packaging material within the temperature range from -40 °C to +70 °C.
- 40.
The design and manufacturing techniques shall be in accordance with national, foreign or international standards or legislation if, during the use of the packaging for transport, they ensure the same or greater degree of nuclear safety, radiation protection, physical protection and handling of a radiation emergency as stipulated by the Atomic Act and its implementing legislation.
- 41.
The design of the package shall include a containment system securely closed by a positive fastening device that cannot be opened unintentionally or due to pressure that may arise within the package.
- 42.
Special form radioactive material may be considered part of the containment system.
- 43.
If the containment system forms a separate unit of the package, it shall be capable of being securely closed by a positive fastening device that is independent of any other part of the package.
- 44.
Any component of the containment system must be designed to withstand any radiolytic decomposition of liquids and other volatile materials and the generation of gas by chemical reaction and radiolysis.
- 45.
The containment system shall retain its radioactive contents during reduction of ambient pressure to 60 kPa.
- 46.
All valves, other than pressure relief valves, shall be provided with an enclosure to retain any leakage.
- 47.
A radiation shield that encloses a component of the package that is part of the containment system shall be so designed as to prevent the unintentional release of that component from the shielded area. Where the radiation shield pursuant to the first sentence forms a separate unit, it must be capable of being securely closed by a positive fastening device that is independent of any other part of the packaging.
- 48.
A package shall be so designed that if it were subjected to the tests specified in Points 19 to 24 of Part II, it would prevent:
a) loss or dispersal of the radioactive contents; and b) more than a 20 % increase in the maximum radiation level on an arbitrary location on the external surface of the package.
- 49.
The design of a package intended for liquid radioactive or fissile material shall expand with space to accommodate thermal changes in the volume of the liquid radioactive contents, dynamic effects and filling dynamics.
- 50.
A Type A package designed to contain liquid radioactive or fissile material shall meet the conditions specified in Point 48(a) if subjected to tests specified in Point 25 of Part II and a) contain sufficient absorbent material that
- 1. will absorb at least twice its volume of liquid contents; and
- 2. is suitably positioned so as to contact the liquid in the event of leakage; or b) be provided with a containment system composed of primary inner and secondary outer containment components designed to enclose the liquid contents completely and to ensure their retention within the secondary outer containment components, even if the primary inner components leak.
- 51.
A package designed for gases shall prevent loss or dispersal of the radioactive contents during tests specified in Point 25 of Part II, except for a Type A package designed for tritium gas or for noble gases.
I.8. REQUIREMENTS FOR TYPE B(U) PACKAGES
- 52.
A Type B(U) package shall be designed to meet the requirements of Points 7 to 18, 36 to 47, 48(b), 49, 53 to 66 and of Points 19 to 21 if carried by air.
- 53.
- 1. A package shall be so designed that heat generated within the package by its contents shall not negatively affect compliance with containment system and shielding requirements, as follows:
a) under ambient conditions specified in Points 56 and 57; b) under normal conditions of transport specified in Points 19 to 24 of Part II; and c) if left unattended for seven days.
- 2. Particular attention shall be paid to the effects of heat that may
a) alter the arrangement, the geometrical form, or the physical state of the radioactive contents; b) cause deformation or melting of the radioactive content, receptacle, or packaging enclosing the radioactive content; c) reduce the efficiency of the packaging through differential thermal expansion, cracking or melting of the shielding material; and d) accelerate corrosion when combined with moisture.
- 54.
Except for a package transported under exclusive use, a package shall be so designed that the temperature of an arbitrary part of an easily accessible surface shall not exceed 50 °C a) under ambient conditions specified in Point 56; and b) if it is not exposed to sunlight.
- 55.
- 1. Except for a package transported by air pursuant to Point 19, the maximum temperature of an arbitrary part of an easily accessible surface of a package shall not exceed 85 °C a) under conditions of exclusive use under ambient conditions pursuant to Point 56; b) if it is not exposed to sunlight; and c) if left unattended for seven days.
- 2. Barriers or screens intended for protection of transport workers may be taken into account without the need for these to be tested as packages.
- 56.
Ambient temperature is defined as 38 °C.
- 57.
Sunlight exposure conditions and their values are specified in Table 1.
- 58.
A package that includes thermal protection for the purpose of satisfying the requirements of the thermal test specified in Point 28 of Part II shall be so designed that such protection will remain effective if the package is subjected to the tests specified in Points 19 to 24, and further if subjected, depending on the mass, average specific mass and activity of the package according to rules specified in Point 59(b), to tests specified in Points 27(a) and 27(b), or in Points 27(b) and 27(c) of Part II. Thermal protection on the exterior of the package shall be designed so not to be rendered ineffective by ripping, cutting, skidding, abrading or rough handling.
Table 1 Insolation values Case Form and location of surface Insolation for 12 h per day (W/m2) 1 Flat surfaces transported horizontally downward facing 0
2 Flat surfaces transported horizontally upward facing 800 3
Surfaces transported vertically 200a) 4 Other downward facing (not horizontal) surfaces 200a) 5 All other surfaces 400a)
Legend:
a) Alternatively, a sine function may be used, with an absorption coefficient adopted and the effects of possible reflection from neighbouring objects neglected.
- 59.
- 1. A package shall be designed so that a) it restricts the loss of radioactive contents to not more than 10-6 A2 per hour after performance of tests specified in Part 19 to 24 of Part II; b) it retains sufficient shielding to ensure that the radiation level 1 m from the surface of the package does not exceed 10 mSv/hwith the maximum radioactive contents that the package is designed to contain, according to
- 1. Point 27(c) of Part II, if the package has a mass not greater than 500 kg, a mean density not greater than 1 000 kg/m3 based on its external dimensions, and radioactive contents greater than 1 000 A2 not as special form radioactive material; or
- 2. Point 27(a) of Part II for other packages; and c) the accumulated loss of radioactive contents in a period of seven days does not exceed 10 A2 for 85Kr and A2 for all other radionuclides after the performance of tests specified in (a) or (b).
- 2. Where mixtures of different radionuclides are present, the provisions of Points 5 to 7 of Annex 3 to this decree shall apply to the calculation of A2, except that for 85Kr an effective A2(i) value equal to 10 A2 may be used. When determining loss of radioactive contents pursuant to (1)(a), the assessment shall take into account the external contamination limits specified in Point 8 of Annex 4 to this decree.
- 60.
A package for the transport of radioactive contents with activity greater than 105 A2 shall be so designed that if it were subjected to the enhanced water immersion test specified in Point 30 of Part II, there would be no rupture of the containment system.
- 61.
Compliance with the permitted activity release limits shall depend neither upon filters nor upon a mechanical cooling system.
- 62.
A package shall not include a pressure relief system from the containment system that would allow the release of radioactive material to the environment under the conditions of the tests specified in Points 19 to 24 and 26 to 29 of Part II.
- 63.
A package shall be so designed that if it were at the maximum normal operating pressure and it were subjected to the tests specified in 19 to 24 and 26 to 29 of Part II, the levels of strains in the containment system would not attain values that would adversely affect the fulfilment of other requirements of this decree.
- 64.
A package shall not have a maximum normal operating pressure in excess of 700 kPa.
- 65.
A package containing low dispersible radioactive material shall be so designed that any features added to the low dispersible radioactive material that are not part of it, or any internal components of the packaging, shall not adversely affect the characteristics of the low dispersible radioactive material.
- 66.
A package shall be designed for an ambient temperature range of -40 °C to
+38 °C.
I.9. REQUIREMENTS FOR TYPE B(M) PACKAGES
- 67.
- 1. Type B(M) packages shall meet the requirements for Type B(U) packages specified in Point 52.
- 2. The requirements of (1) need not be met during carriage within the Czech Republic or during carriage solely between the Czech Republic and certain states if the Office or the Office and a relevant authority of those states approve the packaging type pursuant to requirements other than those specified in Points 37, 55 to 57 and 60 to 66. Notwithstanding, the requirements for Type B(U) packages specified in Points 55 and 60 to 66 shall be met as far as practicable.
- 68.
Intermittent venting of Type B(M) packages is possible provided the the Office stipulates this in a type approval decision or if, in the case of international carriage, the Office and the relevant authority of the state that the carriage concerns stipulate this.
I.10. REQUIREMENTS FOR TYPE C PACKAGES
- 69.
A Type C package shall be designed to meet the requirements of Points 7 to 21, 36 to 47, 48(b), 49, 53 to 57, 61 to 66 and 70 to 72.
- 70.
A package shall be capable of meeting the assessment criteria prescribed for tests in Points 59(b) and 63 after being placed in an environment defined by a thermal conductivity of 0.33 W/(m*K) and a temperature of 38 °C in the steady state.
Initial conditions for assessment of the package are that any thermal insulation of the package remains intact, the package is at the maximum normal operating pressure, and the ambient temperature is 38 °C.
- 71.
- 1. A package shall be designed so that a) at maximum normal operating pressure and after the performance of tests specified in Points 19 to 24, it would restrict the loss of radioactive contents to not more than 10-6 A2 per hour; and b) after performance of the series of tests specified in Point 34 of Part II
- 1. it retains sufficient shielding to ensure that the radiation level 1 m from the surface of the package does not exceed 10 mSv/h with the maximum radioactive contents that the package is designed to contain; and
- 2. the accumulated loss of radioactive contents in a period of seven days does not exceed 10 A2 for 85Kr and A2 for other radionuclides.
- 2. Where mixtures of different radionuclides are present, the provisions of Points 5 to 7 of Annex 3 to this decree shall apply to the calculation of A2, except that for 85Kr an effective A2(i) value equal to 10 A2 may be used. When determining loss of radioactive contents pursuant to (1), external non-fixed contamination limits specified in Point 8 of Annex 4 to this decree shall be taken into account.
- 72.
A package shall be so designed that if it were subjected to the enhanced water immersion test specified in Point 30 of Part II, there would be no rupture of the containment system.
I.11. REQUIREMENTS FOR PACKAGES CONTAINING FISSILE MATERIAL
- 73.
Fissile material shall be transported so as to:
a) Maintain subcriticality during routine, normal and accident conditions of transport; in particular, the following contingencies shall be considered:
- 1. leakage of water into or out of the package;
- 2. loss of efficiency of built-in neutron absorbers or moderators;
- 3. rearrangement of the contents either within the package or as a result of loss from the package;
- 4. reduction of spaces within or between packages;
- 5. packages becoming immersed in water or buried in snow; and
- 6. temperature changes; and b) meet the requirements:
- 1. of Point 36 except for unpackaged material when specifically allowed by Point 17(e) of Annex 3 to this decree;
- 2. of radioactive properties of fissile material stipulated by this decree;
- 3. of Point 37 unless the material is excepted by Point 17 of Annex 3 to this decree; and
- 4. of Points 76 to 86 unless the material is excepted by Point 17 of Annex 3 to this decree, and Point 74 or 75.
- 74.
A package containing fissile material that meets the requirements of (d) and one of the provisions of (a) to (c) is excepted from the requirements of Points 76 to 86 of Part I.
a) A package containing fissile material in any form provided that:
- 1. the smallest external dimension of the package is not less than 10 cm; and
- 2. the criticality safety index of the package does not exceed 10, where it is calculated using the following formula:
where is the mass of 235U in the package in grams, is the mass of other fissile radionuclides in the package in grams, Z are the values taken from Table 2.
b) A package containing fissile material in any form provided that:
- 1. the smallest external dimension of the package is not less than 30 cm;
- 2. the package, after being subjected to the tests specified in Points 19 to 24 of Part II, retains its fissile material contents, preserves the minimum overall outside dimensions of at least 30 cm, and prevents the entry of a 10 cm cube; and
- 3. the criticality safety index of the package does not exceed 10, where it is calculated using the following formula:
where is the mass of 235U in the package in grams, is the mass of other fissile radionuclides in the package in grams, Z are the values are taken from Table 2.
c) A package containing fissile material in any form provided that:
- 1. the smallest external dimension of the package is not less than 10 cm;
- 2. the package, after being subjected to the tests specified in Points 19 to 24 of Part II, retains its fissile material contents, preserves the minimum overall outside dimensions of at least 10 cm, and prevents the entry of a 10 cm cube;
- 3. the criticality safety index is calculated using the following formula:
where is the mass of 235U in the package in grams, is the mass of other fissile radionuclides in the package in grams and
- 4. the maximum mass of fissile radionuclides in any package does not exceed 15 g.
d) The total mass of beryllium, hydrogenous material enriched in deuterium, graphite and other allotropic forms of carbon in an individual package shall not be greater than the mass of fissile radionuclides in the package except where their total concentration does not exceed 1 g in any 1 000 g of material.
Beryllium incorporated in copper alloys up to 4 % by weight of the alloy does not need to be considered.
Table 2 Values of Z for calculation of the criticality safety index pursuant to Point 74 Enrichmenta)
Z Uranium enriched up to 1.5 %
2200 Uranium enriched up to 5%
850 Uranium enriched up to 10%
660 Uranium enriched up to 20%
580 Uranium enriched up to 100%
450 Legend:
a) If a package contains uranium with varying enrichments of 235U, then the value corresponding to the highest enrichment shall be used for Z.
- 75.
A package containing not more than 1 000 g of plutonium are excepted from the
requirements of Points 76 to 86 provided that:
a) not more than 20 % of the plutonium by mass is fissile radionuclides; b) the criticality safety index is calculated using the following formula:
where is the mass of plutonium in the package in grams and c) the amount of uranium contained along with plutonium in the package does not exceed 1 % of the mass of the plutonium.
I.11.1. Contents specification for assessments of package designs containing fissile material
- 76.
Where the chemical or physical form, isotopic composition, mass or concentration, moderation ratio or density, or geometric configuration is not known, the assessments of Points 80 to 85 shall be performed assuming that each unknown parameter has a value that gives the maximum neutron multiplication consistent with known conditions and parameters in these assessments.
- 77.
The assessment of irradiated nuclear fuel according to Points 80 to 85 shall be based on:
a) an isotopic composition demonstrated to provide maximum neutron multiplication during irradiation history; b) or a conservative estimate of the neutron multiplication for assessment of the package. After irradiation but prior to shipment, a measurement shall be performed to confirm the conservatism of the isotopic composition.
I.11.2. Geometry and temperature requirements
- 78.
A package, after being subjected to the tests specified in Points 19 to 24:
a) shall preserve minimum overall outside dimensions of at least 10 cm; and b) shall prevent the entry of a 10 cm cube.
- 79.
A package shall be designed for an ambient temperature range of -40 °C to
+38 °C unless the Office specifies otherwise in a type approval decision.
I.11.3. Assessment of an individual package in isolation
- 80.
For a package in isolation, it shall be assumed that water can leak into void spaces or out of all void spaces of the package, including those within the containment system. If the design incorporates special features to prevent leakage of water into void spaces or out of void spaces, even as a result of operator error, it may be assumed that water leaks neither into or out of these spaces. Special features are a) multiple high standard water barriers, not less than two of which would remain watertight if the package were subject to the tests prescribed in Point 85(b), and a high degree of quality control in the manufacture, maintenance and repair of packaging, and tests to demonstrate the closure of each package before each shipment; or b) for packages containing uranium hexafluoride with a maximum uranium enrichment of 5 % by mass 235U:
- 1. no physical contact between the valve and any other component of the packaging other than at its original point of attachment for the test
specified in Point 85(b), and perfectly leak-proof valves after the performance of tests specified in Point 28 of Part II; and
- 2. a high degree of quality control in the manufacture, maintenance and repair of packaging, and tests to demonstrate closure of each package before each shipment.
- 81.
When assessing an isolated package, it shall be assumed that the confinement system causes reflection of neutrons as would be caused by a layer of water at least 20 cm thick or bigger reflection of neutrons as may be caused by the surrounding material of the packaging. When it can be demonstrated that the confinement system remains within the packaging following the tests prescribed in Point 85(b), the reflection of neutrons by a layer of water at least 20 cm thick may be assumed in Point 82(c).
- 82.
A package shall remain subcritical under the assumptions of Points 80 and 81 and under conditions that result in the maximum neutron multiplication consistent with:
a) routine conditions of transport; b) the tests specified in Point 84(b); and c) the tests specified in Point 85(b).
- 83.
For a package transported by air:
a) the package shall be subcritical under conditions consistent with the Type C package tests specified in Point 34 of Part II, assuming reflection by at least 20 cm of water but no leakage of water into the package; and b) in the assessment pursuant to Point 82, special features pursuant to Point 80 are not allowed, unless following Type C package tests specified in Point 34 of Part II and water ingress tests for a package pursuant to Point 33 of Part II, leakage of water into void spaces and out of void spaces is prevented.
I.11.4. Assessment of package arrays under normal transport conditions
- 84.
A number N shall be derived, such that a set of five times N packages shall be subcritical for the arrangement and package conditions that provide the maximum neutron multiplication, where:
a) there shall not be any substance between the packages, and the package arrangement is exposed on all sides to neutron reflection as would be caused by a layer of water at least 20 cm thick; and b) the state of each package corresponds to a condition after the performance of tests specified in Points 19 to 24 of Part II.
I.11.5. Assessment of package arrays under accident conditions of transport
- 85.
A number N shall be derived, such that a set of two times N packages shall be subcritical for the arrangement and package conditions that provide the maximum neutron multiplication, where:
a) there is a hydrogen moderator between the packages, and the package arrangement is exposed on all sides to neutron reflection as would be caused by a layer of water at least 20 cm thick; b) the state of each package corresponds to a condition after the performance of tests specified in Points 19 to 24 of Part II and after the performance of the more limiting of the following tests:
- 1. for packages having a mass not greater than 500 kg and an overall density not greater than 1 000 kg/m3 based on external dimensions, according to Point 27(b), Point 27(c), Point 28, and either according to Point 29 or according to Points 31 to 33 of Part II; or
- 2. for other packages according to Point 27(a), Point 27(b), Point 28, and either according to Point 29 or according to Points 31 to 33 of Part II; and c) when part of the fissile material escapes from the containment system following the tests specified in Point 85(b), it shall be assumed that fissile material escaped from each package in the array. All of the fissile material shall be arranged and moderated to achieve maximum neutron multiplication and neutron reflection as would be caused by a layer of water at least 20 cm thick.
I.11.6. Stipulation of the criticality safety index
- 86.
The criticality safety index for packages containing fissile material is calculated according to the formula:
where N is the smaller of two values of N according to Points 84 and 85.
The value of the critical safety index may be zero, provided that an unlimited number of packages are subcritical (i.e. N is effectively equal to infinity in both cases).
PART II II. TEST PROCEDURES II.1. DEMONSTRATION OF COMPLIANCE
- 1.
Demonstration of compliance with the performance standards required in Part I shall be accomplished by one or more of the methods listed in (a) to (d). The methods are as follows:
a) a test with specimens representing LSA-III material, special form radioactive material, or low dispersible radioactive material, or with prototypes or samples of the packaging. The contents of the specimen or the packaging for the tests shall simulate as closely as practicable the expected range of radioactive contents. The specimens or packaging to be tested shall be prepared as presented for transport; b) presentation of documentation from a prior successful demonstration of conformance pursuant to (a), (c) and (d) of a sufficiently similar nature; c) tests with models of appropriate scale with features that are significant with respect to the tested properties, if engineering experience has shown the results of such tests to be suitable for design purposes; when a scale model is used, the need to adjust certain test parameters shall be taken into account; and d) calculation, or reasoned argument, when the calculation procedures and parameters are generally considered to be reliable and conservative.
- 2.
Appropriate assessment methods shall be used to assess tests performed on the specimen, prototype or sample. Test assessment must prove compliance with requirements stipulated in Part I and compliance of test procedures with requirements in Part II.
II.2. LEACHING TESTS FOR A GROUP LSA-III MATERIAL WITH LOW SPECIFIC ACTIVITY AND FOR A LOW DISPERSIBLE RADIOACTIVE MATERIAL
- 3.
A solid material sample representing the entire contents of the package shall be immersed for seven days in water at room temperature. The volume of water to be used in the test shall be sufficient to ensure that at the end of the seven-day test period, the free volume of the unabsorbed and unreacted water remaining shall be at least 10 % of the volume of the solid test sample. The water shall have an initial pH of 6 to 8 and a maximum conductivity of 1 mS/m at 20 °C. The total activity of the free volume of water shall be measured following the seven-day immersion of the test sample.
II.3. TESTS FOR SPECIAL FORM RADIOACTIVE MATERIAL II.3.1. General requirements
- 4.
Specimens that contain or simulate special form radioactive material shall be subjected to an impact test, the percussion test, the bending test and the heat test specified in Points 5 to 9. A different specimen may be used for each of the tests.
Following each test, a leaching assessment or volumetric leakage test shall be performed on the specimen by a method no less sensitive than the methods given in Point 10 for non-dispersible solid material or in Point 11 for encapsulated material.
II.3.2. Test methods
- 5.
Impact test: The specimen shall drop onto the target from a height of 9 m. The target shall be as defined in Point 17.
- 6.
Percussion test: The specimen shall be placed on a sheet of lead that is supported by a smooth solid surface and struck by the flat face of a mild steel bar so as to cause an impact equivalent to that resulting from a free drop of 1.4 kg through 1 m. The lower part of the bar shall be 25 mm in diameter with the edges rounded off to a radius of 3.0 +/- 0.3 mm. The lead sheet, of hardness number 3.5-4.5 on the Vickers scale and not more than 25 mm thick, shall cover an area greater than that covered by the specimen. A fresh surface of lead shall be used for each impact.
The bar shall strike the specimen so as to cause maximum damage.
- 7.
Bending test: The test shall apply only to long, slender sources with both a minimum length of 10 cm and a length to minimum width ratio of not less than
- 10. The specimen shall be rigidly clamped in a horizontal position so that one half of its length protrudes from the face of the clamp. The orientation of the specimen shall be such that the specimen will suffer maximum damage when its free end is struck by the flat face of a steel bar. The steel bar shall strike the specimen so as to
cause an impact equivalent to that resulting from a free vertical drop of 1.4 kg through 1 m. The lower part of the bar shall be 25 mm in diameter with the edges rounded off to a radius of 3.0 +/- 0.3 mm.
- 8.
Heat test: The specimen shall be heated in air to a temperature of 800 °C and held at that temperature for a period of 10 min. and shall then be allowed to cool.
- 9.
Specimens that comprise or simulate radioactive material enclosed in a sealed capsule may be excepted from:
a) the tests prescribed in Points 5 and 6, provided that the specimens are alternatively subjected to the impact test for the appropriate class pursuant to ISO 2919:2012(E):
- 1. the Class 4 impact test if the mass of the special form radioactive material is less than or equal to 200 g; or
- 2. the Class 5 impact test if the mass of the special form radioactive material is greater than 200 g but less than 500 g; and b) the tests prescribed in Point 8, provided that the specimens are alternatively subjected to the Class 6 heat test pursuant to ISO 2919:2012(E).
II.3.3. Leaching and volumetric leakage test methods
- 10.
For specimens that comprise or simulate non-dispersible solid material, a leaching assessment shall be performed as follows:
a) The specimen shall be immersed for seven days in water at room temperature.
The volume of water to be used in the test shall be sufficient to ensure that at the end of the seven-day test period, the free volume of the unabsorbed and unreacted water remaining shall be at least 10 % of the volume of the solid test sample itself. The water shall have an initial pH of 6 to 8 and a maximum conductivity of 1 mS/m at 20 °C; b) Then the water with the specimen shall then be heated to a temperature of 50 +/-
5 °C and maintained at this temperature for 4 h; c) Then the activity of the water shall then be determined; d) Then the specimen shall then be kept for at least seven days in still air at not less than 30 °C and with a relative humidity of not less than 90 %;
e) Then the specimen shall then be immersed in water of the same specification as that in (a) and the water with the specimen heated to 50 +/- 5 °C and maintained at this temperature for 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; f) Lastly the activity of the water shall then be determined.
- 11.
For specimens that comprise or simulate radioactive material enclosed in a sealed capsule, either a leaching assessment or a volumetric leakage assessment shall be performed as follows:
a) a leaching test:
The specimen shall be immersed in water at room temperature. The water shall have an initial pH of 6 to 8 and a maximum conductivity of 1 mS/m at 20 °C;
- 1. Then the water with the specimen shall then be heated to a temperature of 50 +/- 5 °C and maintained at this temperature for 4 h;
- 2. Then the activity of the water shall then be determined;
- 3. Then the specimen shall then be kept for at least seven days in still air at not less than 30 °C and with a relative humidity of not less than 90 %;
- 4. The process according to Points 1, 2, and 3 shall be repeated once; b) The alternative volumetric leakage assessment shall include any of the tests prescribed in ISO 9978:1992(E).
II.4. TESTS FOR LOW DISPERSIBLE RADIOACTIVE MATERIAL
- 12.
A specimen that comprises or simulates low dispersible radioactive material shall be subjected to the enhanced thermal test specified in Point 36 and the impact test specified in Point 37. A different specimen may be used for each of the tests.
Following the test in the first sentence, the specimen shall be subjected to the leach test specified in point 3. After each test it shall be determined if the applicable requirements of Point 5 of Part I have been met.
II.5. TESTS FOR PACKAGES II.5.1. Test specimen preparation
- 13.
All specimens shall be inspected before testing in order to identify and record faults or damage, including the following:
a) divergence from design; b) manufacturing defects; c) corrosion or other damage; and d) deformation.
- 14.
The containment system of the package shall be clearly specified.
- 15.
The external features of the specimen shall be clearly identified so that reference may be made simply and clearly to any part of such a specimen.
II.5.2. Testing the integrity of the containment system and shielding and assessing criticality safety
- 16.
After performance of tests specified in Points 18 to 37:
a) faults and damage shall be identified and recorded; b) it shall be determined whether the integrity of the containment system and shielding has been retained to the extent required in Part I for the package under test; and c) for a package containing fissile material, it shall be determined whether the assumptions and conditions used in the assessments required by Points 73 to 86 of Part I also apply to the tested package.
II.5.3. Target for drop tests
- 17.
The target for the drop test specified in Points 5, 22, 25(a), 27 and 35 shall be a flat, horizontal surface of such a character that any increase in its resistance to displacement or deformation upon impact by the specimen would not significantly increase damage to the specimen.
II.5.4. Test for package designed to contain uranium hexafluoride
- 18.
Specimens that comprise or simulate packagings designed to contain 0.1 kg or more of uranium hexafluoride shall be tested hydraulically at an internal pressure of at least 1.38 MPa. For stipulated periodic review of packaging, an equivalent non-destructive test may be applied that is stipulated in documentation used as the basis for a packaging type approval decision issued by the Office, and, in the case of international carriage, also by the relevant authority of the state that the carriage concerns.
II.5.5. Tests demonstrating the ability to withstand normal transport conditions
- 19.
Tests demonstrating the ability to withstand normal conditions of transport are the water spray test, the free drop test, the stacking test and the penetration test. A specimen of the package shall be subjected to the free drop test, the stacking test and the penetration test, preceded in each case by the water spray test. One specimen may be used for all the tests pursuant to the first sentence, provided that the requirements of Point 20 are fulfilled.
- 20.
The time interval between the conclusion of the water spray test and the subsequent test shall be such that the water has soaked in to the maximum extent, without appreciable drying of the exterior of the specimen. In the absence of any evidence to the contrary, this interval shall be taken to be 2 h if the water spray is applied from four directions simultaneously. However, if the water spray is applied from each of the four directions consecutively, the subsequent test shall be performed immediately after the end of the water spray test.
- 21.
Water spray test: The specimen shall be subjected to a water spray test that simulates exposure to rainfall of approximately 5 cm per hour for at least 1 h.
- 22.
Free drop test: The specimen shall drop onto the target so as to suffer maximum damage in respect of the safety features to be tested:
a) The height of drop measured from the lowest point of the specimen to the upper surface of the target shall be not less than the distance specified in Table 3 for the applicable package mass. The target shall meet the requirements of Point 17; and b) for rectangular fibreboard or wood packages not exceeding a mass of 50 kg, a separate specimen shall be subjected to a free drop onto each corner from a height of 0.3 m; or c) for cylindrical fibreboard not exceeding a mass of 100 kg, a separate specimen shall be subjected to a free drop onto each of the quarters of each rim from a height of 0.3 m.
- 23.
Stacking test: Unless the shape of the packaging effectively prevents stacking, the specimen shall be subjected, for a period of 24 h, to a compressive load greater of the following:
a) force equivalent to five times the maximum weight of the package; or b) force equivalent to the product of the vertically projected area of the package and a pressure of 13 kPa.
Table 3 Free drop distance for tests proving the ability of a package to withstand normal conditions of transport Mass of packaging with rated content (kg)
Free drop distance (m) less than 5 000 1.2 greater than or equal to 5 000 and less than 10 000 0.9 greater than or equal to 10 000 and less than 15 000 0.6 greater than or equal to 15 000 0.3
- 24.
Penetration test: The specimen shall be placed on a rigid, flat, horizontal surface that will not move significantly while the test is being carried out:
a) a bar 3.2 cm in diameter with a hemispherical end and a mass of 6 kg shall be dropped and directed to fall, with its longitudinal axis vertical, onto the centre of the weakest part of the specimen, so that, if it penetrates sufficiently far, it will hit the containment system. The bar shall not be significantly deformed by the test performance; and b) the height of drop of the bar measured from its lower end to the intended point of impact on the upper surface of the specimen shall be 1 m.
II.5.6. Additional tests for Type A package designed for liquids and gases
- 25.
A specimen, or separate specimens, shall be subjected to tests specified in (a) and (b). If it can be demonstrated that one test is more severe for the specimen, the specimen shall be subjected to the more severe test:
a) Free drop test: the specimen shall drop onto the target so as to cause the most damage to the containment system. The height of the drop measured from the lowest part of the specimen to the upper surface of the target shall be 9 m. The target shall be as defined in Part 17; and b) Penetration test: the specimen shall be subjected to the test specified in Point 24 with a drop height of 1.7 m.
II.5.7. Tests demonstrating the ability to withstand accident conditions during transport
- 26.
The specimen shall be subjected to the cumulative effects of the tests specified in Points 27 and 28, in that order. Following these tests, either this specimen or another separate specimen shall be subjected to the water immersion test as specified in Point 29, and in the case of a Type B(U) or Type B(M) package containing more than 105 A2 and a Type C package, also the test as specified in Point 30.
- 27.
Mechanical test: the mechanical test consists of three different drop tests:
a) drop test I: the specimen shall drop onto the target so as to suffer maximum damage, and the height of the drop measured from the lowest point of the specimen to the upper surface of the target shall be 9 m. The target shall be as defined Point 17.
b) drop test II: the specimen shall drop onto a bar rigidly mounted perpendicularly on the target so as to suffer maximum damage. The height of the drop measured from the intended point of impact of the specimen to the upper surface of the bar shall be 1 m. The bar shall be of solid mild steel of circular section, 15.0 +/- 0.5 cm in diameter and 20 cm long, unless a longer bar would cause greater damage. Otherwise a bar of sufficient length to cause maximum damage shall be used. The upper end of the bar shall be flat and horizontal with
its edge rounded off to a radius of not more than 6 mm. The target shall meet the requirements of Point 17; c) drop test III: the specimen shall be subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage by the drop of a 500 kg mass from 9 m onto the specimen. The mass shall consist of a 1 m x 1 m solid mild steel plate and shall fall in a horizontal attitude. The lower face of the steel plate shall have its edges and corners rounded off to a radius of not more than 6 mm. The height of the drop shall be measured from the underside of the plate to the highest point of the specimen. The target shall meet the requirements of Point 17.
Each specimen shall be subjected to the applicable drops, as specified in Point 59 or 85 of Part I. The order of the drop tests shall be such that, on completion of the mechanical test, the specimen shall have suffer maximum damage in the thermal test that follows.
- 28.
Thermal test: the specimen shall be in thermal equilibrium under conditions of an ambient temperature of 38 °C, subject to insolation conditions specified in Table 1 and subject to the design maximum rate of internal heat generation within the package from the radioactive contents. Any of these parameters are allowed to have different values prior to, and during, the test, provided due account is taken of them in the subsequent assessment of package response. The specimen must be exposed to the following in the specified order:
a) for a period of 30 min. to a thermal environment that provides a heat flux at least equivalent to that of a hydrocarbon fuel-air fire in sufficiently quiescent ambient conditions to give a minimum average flame emissivity coefficient of 0.9 and an average temperature of at least 800 °C, fully engulfing the specimen, with a surface absorptivity coefficient of 0.8 or that value that the package may be demonstrated to possess if exposed to the fire specified; and b) an ambient temperature of 38 °C, subject to insolation conditions specified in Table 1 and subject to the design maximum rate of internal heat generation within the package by the radioactive contents for a sufficient period to ensure that temperatures in the specimen are everywhere decreasing and/or are approaching initial steady state conditions. Any of these parameters are allowed to have different values prior to, and during, the test, provided due account is taken of them in the subsequent assessment of package response.
During and following the test, the specimen shall not be artificially cooled and any combustion of materials of the specimen shall be permitted to proceed naturally.
- 29.
Water immersion test: the specimen shall be immersed under at least 15 m of water for a period of not less than 8 h in the attitude that will lead to maximum damage. For demonstration purposes, an external gauge pressure of at least 150 kPa shall be considered to meet these conditions.
II.5.8. Enhanced water immersion test for Type B(U) and Type B(M) packages containing more than 105 A2 and for Type C packages
- 30.
Water immersion test: the specimen shall be immersed under at least 200 m of water for a period of not less than 1 h. For demonstration purposes, an external gauge pressure of at least 2 MPa shall be considered to meet these conditions.
II.5.9. Water immersion test for radioactive packages containing fissile material
- 31.
A package for which it has been assumed for purposes of assessment under Points 80 to 85 of Part I that water leaks in and out to the extent that results in greatest reactivity shall be excepted from the test specified in Point 33.
- 32.
Before the specimen is subjected to the water leakage test specified in Point 33, it shall be subjected to the tests in Point 27(b) and Point 27(a), or 727(c) and 28.
- 33.
The specimen shall be immersed under at least 0.9 m of water for a period of not less than 8 h in the attitude for which maximum leakage is expected.
II.5.10. Tests for type C packages
- 34.
Specimens shall be subjected to the following series of tests:
a) as specified Points 27(a), 27(c), 35, and 36, in that order; and b) as specified in (37).
Separate specimens may be used for the series of tests in (a) and for the test in (b).
- 35.
Puncture-tearing test: the specimen shall be subjected to the damaging effects of a vertical solid probe made of mild steel. The orientation of the package specimen and the impact point on the package surface shall be such as to cause maximum damage at the conclusion of the test sequence specified in Point 34(a).
a) A specimen representing a package having a mass of less than 250 kg, shall be placed on a target and subjected to a probe having a mass of 250 kg falling from a height of 3 m above the intended impact point. For this test the probe shall be a 20 cm diameter cylindrical bar with the striking end forming the frustum of a right circular cone with the following dimensions: 30 cm height and 2.5 cm diameter at the top with its edge rounded off to a radius of not more than 6 mm. The target on which the specimen is placed shall be as specified in Point 17.
b) For a package having a mass of 250 kg or more, the base of the probe shall be placed on a target and the specimen dropped onto the probe. The height of the drop, measured from the point of impact with the specimen to the upper surface of the probe, shall be 3 m. The probe for this test shall have the same properties and dimensions as specified in (a), except that the length and mass of the probe shall be such as to cause maximum damage to the specimen. The target on which the specimen is placed shall be as specified in Point 17.
- 36.
Enhanced thermal test: the conditions for this test shall be as specified in Point 28, except that the exposure to the thermal environment shall be for a period of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
- 37.
Impact test: The specimen shall be subject to an impact on a target at a velocity of not less than 90 m/s, at such an orientation as to suffer maximum damage. The target shall be as defined in Point 17, except that the target surface may be at any orientation as long as the surface is normal to the specimen path.
Annex 2 to Decree No REQUIREMENTS FOR TYPE D AND S PACKAGES
- 1.
Type D and S packaging:
a) shall have mechanical ruggedness demonstrably enough with regard to designed manner of manipulation; and b) shall be manufactured from materials whose service life demonstrably corresponds to the designed service life of the packaging. Materials with a shorter service life may be used for packaging components if are readily replaceable during the operation of the storage facility for radioactive waste or spent fuel or the radioactive waste repository.
- 2.
The contents of Type D or Type S packaging shall be sufficiently dried out and surrounded by a defined medium. The Office shall decide on the dryness criteria and parameters of this medium in the type approval decision when requested by the applicant.
- 3.
A Type D or S packaging shall be designed to comply with limits and conditions for the handling of radioactive waste, including relevant acceptability criteria, approved by the Office.
- 4.
Type S packaging shall be manufactured:
a) to meet the requirements specified in Points 7 to 11 and 13 to 16 of Part I of Annex 1 to this decree, and other requirements stipulated by the Office in the type approval decision, taking into account manner of use; b) to ensure feasibility of checking package leak-tightness during the operation of the storage facility for radioactive waste or spent fuel; c) to preserve adequate shielding during normal operation, abnormal operation, design basis accidents and beyond design basis accidents that are not serious accidents. The shielding of the package shall ensure that the radiation level on the exterior does not exceed 10 mSv/h, even at the maximum design contents of radioactive content; d) so that the heat generated inside the packaging by its radioactive contents does not under the normal conditions and at the ambient temperature of 38 °C have a negative effect on compliance with leak-tightness and shielding criteria if the packaging and its contents are left unattended for seven days; e) to eliminate the influence of generated heat, the heat shall not:
- 1. change the spacing, geometrical form or physical state of the radioactive contents, or if radionuclides are sealed within special capsule - cause deformation or melting of this capsule or its radioactive contents;
- 2. reduce the efficiency of the packaging through differential thermal expansion, cracking, or melting of the shielding material;
- 3. accelerate corrosion when combined with moisture; and
- 4. cause the interruption of the residual heat removal; elimination of residual heat shall also be ensured also under beyond design basis accident conditions that are not serious accidents.
Annex 3 to Decree No ACTIVITY LIMITS AND CLASSIFICATION
- 1. GENERAL REQUIREMENTS
- 1.
A radioactive or fissile material is assigned one of the UN numbers listed in Table 1, in accordance with the requirements of Points 8 to 34.
Table 1 Selected UN numbers, names and descriptions UN number NAME a) and description Excepted packages UN 2908 RADIOACTIVE MATERIAL, EXCEPTED PACKAGE - EMPTY PACKAGINGS UN 2909 RADIOACTIVE MATERIAL, EXCEPTED PACKAGE - PRODUCTS OF NATURAL URANIUM or DEPLETED URANIUM or THORIUM UN 2910 RADIOACTIVE MATERIAL, EXCEPTED PACKAGE - A LIMITED AMOUNT OF MATERIAL UN 2911 RADIOACTIVE MATERIAL, EXCEPTED PACKAGE - DEVICES or PRODUCTS UN 3507 RADIOACTIVE MATERIAL, EXCEPTED PACKAGE - URANIUM HEXAFLUORIDE, less than 0.1 kg in a package, excepted fissile material or non-fissile material Materials with low specific activity UN 2912 RADIOACTIVE MATERIAL, MATERIAL WITH LOW SPECIFIC ACTIVITY (LSA-I) excepted fissile material or non-fissile material UN 3321 RADIOACTIVE MATERIAL, MATERIAL WITH LOW SPECIFIC ACTIVITY (LSA-II) excepted fissile material or non-fissile material UN 3322 RADIOACTIVE MATERIAL, MATERIAL WITH LOW SPECIFIC ACTIVITY (LSA-III) excepted fissile material or non-fissile material UN 3324 RADIOACTIVE MATERIAL, MATERIAL WITH LOW SPECIFIC ACTIVITY (LSA-II),
FISSILE MATERIAL UN 3325 RADIOACTIVE MATERIAL, MATERIAL WITH LOW SPECIFIC ACTIVITY (LSA-III), FISSILE MATERIAL Surface contaminated objects UN 2913 RADIOACTIVE MATERIAL, SURFACE CONTAMINATED OBJECTS (SCO-I or SCO-II), excepted fissile substance or non-fissile substance UN 3326 RADIOACTIVE MATERIAL, SURFACE CONTAMINATED OBJECTS (SCO-I or SCO-II), FISSILE SUBSTANCE Type A packages UN 2915 RADIOACTIVE MATERIAL, TYPE A PACKAGE other than special form radioactive material, exceptions of fissile material or non-fissile material UN 3327 RADIOACTIVE MATERIAL, TYPE A PACKAGE, FISSILE MATERIAL other than special form radioactive material UN 3332 RADIOACTIVE MATERIAL, TYPE A PACKAGE, SPECIAL FORM RADIOACTIVE MATERIAL, exceptions of fissile material or non-fissile material UN 3333 RADIOACTIVE MATERIAL, TYPE A PACKAGE, SPECIAL FORM RADIOACTIVE MATERIAL, FISSILE MATERIAL Type B(U) packages UN 2916 RADIOACTIVE MATERIAL, TYPE B(U) PACKAGE exceptions of fissile material or non-fissile material UN 3328 RADIOACTIVE MATERIAL, TYPE B(U) PACKAGE, FISSILE MATERIAL
Type B(M) packages UN 2917 RADIOACTIVE MATERIAL, TYPE B(M) PACKAGE exceptions of fissile material or non-fissile material UN 3329 RADIOACTIVE MATERIAL, TYPE B(M) PACKAGE, FISSILE MATERIAL Type C packages UN 3323 RADIOACTIVE MATERIAL, TYPE C PACKAGE exceptions of fissile material or non-fissile material UN 3330 RADIOACTIVE MATERIAL, TYPE C PACKAGE, FISSILE MATERIAL Transport under special arrangement UN 2919 RADIOACTIVE MATERIAL, TRANSPORT UNDER SPECIAL ARRANGEMENT excepted fissile material or non-fissile material UN 3331 RADIOACTIVE MATERIAL, TRANSPORT UNDER SPECIAL ARRANGEMENT, FISSILE MATERIAL Uranium hexafluoride UN 2977 RADIOACTIVE MATERIAL, URANIUM HEXAFLUORIDE, FISSILE MATERIAL UN 2978 RADIOACTIVE MATERIAL, URANIUM HEXAFLUORIDE excepted fissile material or non-fissile material Legend:
a) NAME can be found in the 'NAME and description' field and is limited to the part written in CAPITAL LETTERS. In Items UN 2909, UN 2911, UN 2913, and UN 3326, only the appropriate NAME from alternative NAMES separated by the conjunction 'or'.
- 2. BASIC RADIONUCLIDE VALUES
- 2.
Table 2 lists basic radionuclide values:
a) A1 and A2 in TBq; b) activity concentration limits for exceptions of material in Bq/g; and c) activity limits for exceptions of material in Bq.
Table 2 Basic radionuclide values Radionuclide (atomic number)
A1
[TBq]
A2
[TBq]
Activity concentrati on limits for exceptions of material
[Bq/g]
Activity limits for an exceptions of consignme nt
[Bq]
Actinium (89)
Ac-225a) 8x10-1 6x10-3 1x101 1x104 Ac-227 (a) 9x10-1 9x10-5 1x10-1 1x103 Ac-228 6x10-1 5x10-1 1x101 1x106 Silver (47)
Ag-105 2x100 2x100 1x102 1x106 Ag-108m (a) 7x10-1 7x10-1 1x101(b) 1x106(b)
Ag-110m (a) 4x10-1 4x10-1 1x101 1x106 Ag-111 2x100 6x10-1 1x103 1x106 Aluminium (13)
Al-26 1x10-1 1x10-1 1x101 1x105
Americium (95)
Am-241 1x101 1x10-3 1x100 1x104 Am-242m (a) 1x101 1x10-3 1x100(b) 1x104(b)
Am-243 (a) 5x100 1x10-3 1x100(b) 1x103(b)
Argon (18)
Ar-37 4x101 4x101 1x106 1x108 Ar-39 4x101 2x101 1x107 1x104 Ar-41 3x10-1 3x10-1 1x102 1x109 Arsenic (33)
As-72 3x10-1 3x10-1 1x101 1x105 As-73 4x101 4x101 1x103 1x107 As-74 1x100 9x10-1 1x101 1x106 As-76 3x10-1 3x10-1 1x102 1x105 As-77 2x101 7x10-1 1x103 1x106 Astatine (85)
At-211 (a) 2x101 5x10-1 1x103 1x107 Gold (79)
Au-193 7x100 2x100 1x102 1x107 Au-194 1x100 1x100 1x101 1x106 Au-195 1x101 6x100 1x102 1x107 Au-198 1x100 6x10-1 1x102 1x106 Au-199 1x101 6x10-1 1x102 1x106 Barium (56)
Ba-131 (a) 2x100 2x100 1x102 1x106 Ba-133 3x100 3x100 1x102 1x106 Ba-133m 2x101 6x10-1 1x102 1x106 Ba-140 (a) 5x10-1 3x10-1 1x101(b) 1x105(b)
Beryllium (4)
Be-7 2x101 2x101 1x103 1x107 Be-10 4x101 6x10-1 1x104 1x106 Bismuth (83)
Bi-205 7x10-1 7x10-1 1x101 1x106 Bi-206 3x10-1 3x10-1 1x101 1x105 Bi-207 7x10-1 7x10-1 1x101 1x106 Bi-210 1x100 6x10-1 1x103 1x106 Bi-210m (a) 6x10-1 2x10-2 1x101 1x105 Bi-212 (a) 7x10-1 6x10-1 1x101(b) 1x105(b)
Berkelium (97)
Bk-247 8x100 8x10-4 1x100 1x104 Bk-249 (a) 4x101 3x10-1 1x103 1x106 Bromine (35)
Br-76 4x10-1 4x10-1 1x101 1x105 Br-77 3x100 3x100 1x102 1x106 Br-82 4x10-1 4x10-1 1x101 1x106 Carbon (6)
C-11 1x100 6x10-1 1x101 1x106 C-14 4x101 3x100 1x104 1x107
Calcium (20)
Ca-41 Unlimited Unlimited 1x105 1x107 Ca-45 4x101 1x100 1x104 1x107 Ca-47 (a) 3x100 3x10-1 1x101 1x106 Cadmium (48)
Cd-109 3x101 2x100 1x104 1x106 Cd-113m 4x101 5x10-1 1x103 1x106 Cd-115 (a) 3x100 4x10-1 1x102 1x106 Cd-115m 5x10-1 5x10-1 1x103 1x106 Cerium (58)
Ce-139 7x100 2x100 1x102 1x106 Ce-141 2x101 6x10-1 1x102 1x107 Ce-143 9x10-1 6x10-1 1x102 1x106 Ce-144 (a) 2x10-1 2x10-1 1x102(b) 1x105(b)
Californium (98)
Cf-248 4x101 6x10-3 1x101 1x104 Cf-249 3x100 8x10-4 1x100 1x103 Cf-250 2x101 2x10-3 1x101 1x104 Cf-251 7x100 7x10-4 1x100 1x103 Cf-252 1x10-1 3x10-3 1x101 1x104 Cf-253 (a) 4x101 4x10-2 1x102 1x105 Cf-254 1x10-3 1x10-3 1x100 1x103 Chlorine (17)
Cl-36 1x101 6x10-1 1x104 1x106 Cl-38 2x10-1 2x10-1 1x101 1x105 Curium (96)
Cm-240 4x101 2x10-2 1x102 1x105 Cm-241 2x100 1x100 1x102 1x106 Cm-242 4x101 1x10-2 1x102 1x105 Cm-243 9x100 1x10-3 1x100 1x104 Cm-244 2x101 2x10-3 1x101 1x104 Cm-245 9x100 9x10-4 1x100 1x103 Cm-246 9x100 9x10-4 1x100 1x103 Cm-247 (a) 3x100 1x10-3 1x100 1x104 Cm-248 2x10-2 3x10-4 1x100 1x103 Cobalt (27)
Co-55 5x10-1 5x10-1 1x101 1x106 Co-56 3x10-1 3x10-1 1x101 1x105 Co-57 1x101 1x101 1x102 1x106 Co-58 1x100 1x100 1x101 1x106 Co-58m 4x101 4x101 1x104 1x107 Co-60 4x10-1 4x10-1 1x101 1x105 Chromium (24)
Cr-51 3x101 3x101 1x103 1x107 Caesium (55)
Cs-129 4x100 4x100 1x102 1x105 Cs-131 3x101 3x101 1x103 1x106
Cs-132 1x100 1x100 1x101 1x105 Cs-134 7x10-1 7x10-1 1x101 1x104 Cs-134m 4x101 6x10-1 1x103 1x105 Cs-135 4x101 1x100 1x104 1x107 Cs-136 5x10-1 5x10-1 1x101 1x105 Cs-137 (a) 2x100 6x10-1 1x101(b) 1x104(b)
Copper (29)
Cu-64 6x100 1x100 1x102 1x106 Cu-67 1x101 7x10-1 1x102 1x106 Dysprosium (66)
Dy-159 2x101 2x101 1x103 1x107 Dy-165 9x10-1 6x10-1 1x103 1x106 Dy-166 (a) 9x10-1 3x10-1 1x103 1x106 Erbium (68)
Er-169 4x101 1x100 1x104 1x107 Er-171 8x10-1 5x10-1 1x102 1x106 Europium (63)
Eu-147 2x100 2x100 1x102 1x106 Eu-148 5x10-1 5x10-1 1x101 1x106 Eu-149 2x101 2x101 1x102 1x107 Eu-150 (with short half-life) 2x100 7x10-1 1x103 1x106 Eu-150 (with long half-life) 7x10-1 7x10-1 1x101 1x106 Eu-152 1x100 1x100 1x101 1x106 Eu-152m 8x10-1 8x10-1 1x102 1x106 Eu-154 9x10-1 6x10-1 1x101 1x106 Eu-155 2x101 3x100 1x102 1x107 Eu-156 7x10-1 7x10-1 1x101 1x106 Fluorine (9)
F-18 1x100 6x10-1 1x101 1x106 Iron (26)
Fe-52 (a) 3x10-1 3x10-1 1x101 1x106 Fe-55 4x101 4x101 1x104 1x106 Fe-59 9x10-1 9x10-1 1x101 1x106 Fe-60 (a) 4x101 2x10-1 1x102 1x105 Gallium (31)
Ga-67 7x100 3x100 1x102 1x106 Ga-68 5x10-1 5x10-1 1x101 1x105 Ga-72 4x10-1 4x10-1 1x101 1x105 Gadolinium (64)
Gd-146 (a) 5x10-1 5x10-1 1x101 1x106 Gd-148 2x101 2x10-3 1x101 1x104 Gd-153 1x101 9x100 1x102 1x107 Gd-159 3x100 6x10-1 1x103 1x106 Germanium (32)
Ge-68 (a) 5x10-1 5x10-1 1x101 1x105 Ge-71 4x101 4x101 1x104 1x108 Ge-77 3x10-1 3x10-1 1x101 1x105
Hafnium (72)
Hf-172 (a) 6x10-1 6x10-1 1x101 1x106 Hf-175 3x100 3x100 1x102 1x106 Hf-181 2x100 5x10-1 1x101 1x106 Hf-182 Unlimited Unlimited 1x102 1x106 Mercury (80)
Hg-194 (a) 1x100 1x100 1x101 1x106 Hg-195m (a) 3x100 7x10-1 1x102 1x106 Hg-197 2x101 1x101 1x102 1x107 Hg-197m 1x101 4x10-1 1x102 1x106 Hg-203 5x100 1x100 1x102 1x105 Holmium (67)
Ho-166 4x10-1 4x10-1 1x103 1x105 Ho-l66m 6x10-1 5x10-1 1x101 1x106 Iodine (53)
I-123 6x100 3x100 1x102 1x107 I-124 1x100 1x100 1x101 1x106 I-125 2x101 3x100 1x103 1x106 I-126 2x100 1x100 1x102 1x106 I-129 Unlimited Unlimited 1x102 1x105 I-131 3x100 7x10-1 1x102 1x106 I-132 4x10-1 4x10-1 1x101 1x105 I-133 7x10-1 6x10-1 1x101 1x106 I-134 3x10-1 3x10-1 1x101 1x105 I-135 (a) 6x10-1 6x10-1 1x101 1x106 Indium (49)
In-111 3x100 3x100 1x102 1x106 In-113m 4x100 2x100 1x102 1x106 In-114m (a) 1x101 5x10-1 1x102 1x106 In-115m 7x100 1x100 1x102 1x106 Iridium (77)
Ir-189 (a) 1x101 1x101 1x102 1x107 Ir-190 7x10-1 7x10-1 1x101 1x106 Ir-192 1x100(c) 6x10-1 1x101 1x104 Ir-194 3x10-1 3x10-1 1x102 1x105 Potassium (19)
K-40 9x10-1 9x10-1 1x102 1x106 K-42 2x10-1 2x10-1 1x102 1x106 K-43 7x10-1 6x10-1 1x101 1x106 Krypton (36)
Kr-79 4x101 2x100 1x103 1x105 Kr-81 4x101 4x101 1x104 1x107 Kr-85 1x101 1x101 1x105 1x104 Kr-85m 8x100 3x100 1x103 1x1010 Kr-87 2x10-1 2x10-1 1x102 1x109 Lanthanum (57)
La-137 3x101 6x100 1x103 1x107
La-140 4x10-1 4x10-1 1x101 1x105 Lutetium (71)
Lu-172 6x10-1 6x10-1 1x101 1x106 Lu-173 8x100 8x100 1x102 1x107 Lu-174 9x100 9x100 1x102 1x107 Lu-174m 2x101 1x101 1x102 1x107 Lu-177 3x101 7x10-1 1x103 1x107 Magnesium (12)
Mg-28 (a) 3x10-1 3x10-1 1x101 1x105 Manganese (25)
Mn-52 3x10-1 3x10-1 1x101 1x105 Mn-53 Unlimited Unlimited 1x104 1x109 Mn-54 1x100 1x100 1x101 1x106 Mn-56 3x10-1 3x10-1 1x101 1x105 Molybdenum (42)
Mo-93 4x101 2x101 1x103 1x108 Mo-99 (a) 1x100 6x10-1 1x102 1x106 Nitrogen (7)
N-13 9x10-1 6x10-1 1x102 1x109 Sodium (11)
Na-22 5x10-1 5x10-1 1x101 1x106 Na-24 2x10-1 2x10-1 1x101 1x105 Niobium (41)
Nb-93m 4x101 3x101 1x104 1x107 Nb-94 7x10-1 7x10-1 1x101 1x106 Nb-95 1x100 1x100 1x101 1x106 Nb-97 9x10-1 6x10-1 1x101 1x106 Neodymium (60)
Nd-147 6x100 6x10-1 1x102 1x106 Nd-149 6x10-1 5x10-1 1x102 1x106 Nickel (28)
Ni-59 Unlimited Unlimited 1x104 1x108 Ni-63 4x101 3x101 1x105 1x108 Ni-65 4x10-1 4x10-1 1x101 1x106 Neptunium (93)
Np-235 4x101 4x101 1x103 1x107 Np-236 (with short half-life) 2x101 2x100 1x103 1x107 Np-236 (with long half-life) 9x100 2x10-2 1x102 1x105 Np-237 2x101 2x10-3 1x100(b) 1x103(b)
Np-239 7x100 4x10-1 1x102 1x107 Osmium (76)
Os-185 1x100 1x100 1x101 1x106 Os-191 1x101 2x100 1x102 1x107 Os-191m 4x101 3x101 1x103 1x107 Os-193 2x100 6x10-1 1x102 1x106 Os-194 (a) 3x10-1 3x10-1 1x102 1x105 Phosphorus (15)
P-32 5x10-1 5x10-1 1x103 1x105 P-33 4x101 1x100 1x105 1x108 Protactinium (91)
Pa-230 (a) 2x100 7x10-2 1x101 1x106 Pa-231 4x100 4x10-4 1x100 1x103 Pa-233 5x100 7x10-1 1x102 1x107 Lead (82)
Pb-201 1x100 1x100 1x101 1x106 Pb-202 4x101 2x101 1x103 1x106 Pb-203 4x100 3x100 1x102 1x106 Pb-205 Unlimited Unlimited 1x104 1x107 Pb-210 (a) 1x100 5x10-2 1x101(b) 1x104(b)
Pb-212 (a) 7x10-1 2x10-1 1x101(b) 1x105(b)
Palladium (46)
Pd-103 (a) 4x101 4x101 1x103 1x108 Pd-107 Unlimited Unlimited 1x105 1x108 Pd-109 2x100 5x10-1 1x103 1x106 Promethium (61)
Pm-143 3x100 3x100 1x102 1x106 Pm-144 7x10-1 7x10-1 1x101 1x106 Pm-145 3x101 1x101 1x103 1x107 Pm-147 4x101 2x100 1x104 1x107 Pm-148m (a) 8x10-1 7x10-1 1x101 1x106 Pm-149 2x100 6x10-1 1x103 1x106 Pm-151 2x100 6x10-1 1x102 1x106 Polonium (84)
Po-210 4x101 2x10-2 1x101 1x104 Praseodymium (59)
Pr-142 4x10-1 4x10-1 1x102 1x105 Pr-143 3x100 6x10-1 1x104 1x106 Platinum (78)
Pt-188 (a) 1x100 8x10-1 1x101 1x106 Pt-191 4x100 3x100 1x102 1x106 Pt-193 4x101 4x101 1x104 1x107 Pt-193m 4x101 5x10-1 1x103 1x107 Pt-195m 1x101 5x10-1 1x102 1x106 Pt-197 2x101 6x10-1 1x103 1x106 Pt-197m 1x101 6x10-1 1x102 1x106 Plutonium (94)
Pu-236 3x101 3x10-3 1x101 1x104 Pu-237 2x101 2x101 1x103 1x107 Pu-238 1x101 1x10-3 1x100 1x104 Pu-239 1x101 1x10-3 1x100 1x104 Pu-240 1x101 1x10-3 1x100 1x103 Pu-241 (a) 4x101 6x10-2 1x102 1x105 Pu-242 1x101 1x10-3 1x100 1x104 Pu-244 (a) 4x10-1 1x10-3 1x100 1x104
Radium (88)
Ra-223 (a) 4x10-1 7x10-3 1x102(b) 1x105(b)
Ra-224 (a) 4x10-1 2x10-2 1x101(b) 1x105(b)
Ra-225 (a) 2x10-1 4x10-3 1x102 1x105 Ra-226 (a) 2x10-1 3x10-3 1x101(b) 1x104(b)
Ra-228 (a) 6x10-1 2x10-2 1x101(b) 1x105(b)
Rubidium (37)
Rb-81 2x100 8x10-1 1x101 1x106 Rb-83 (a) 2x100 2x100 1x102 1x106 Rb-84 1x100 1x100 1x101 1x106 Rb-86 5x10-1 5x10-1 1x102 1x105 Rb-87 Unlimited Unlimited 1x104 1x107 Rb (natural)
Unlimited Unlimited 1x104 1x107 Rhenium (75)
Re-184 1x100 1x100 1x101 1x106 Re-184m 3x100 1x100 1x102 1x106 Re-186 2x100 6x10-1 1x103 1x106 Re-187 Unlimited Unlimited 1x106 1x109 Re-188 4x10-1 4x10-1 1x102 1x105 Re-189(a) 3x100 6x10-1 1x102 1x106 Re (natural)
Unlimited Unlimited 1x106 1x109 Rhodium (45)
Rh-99 2x100 2x100 1x101 1x106 Rh-101 4x100 3x100 1x102 1x107 Rh-102 5x10-1 5x10-1 1x101 1x106 Rh-102m 2x100 2x100 1x102 1x106 Rh-103m 4x101 4x101 1x104 1x108 Rh-105 1x101 8x10-1 1x102 1x107 Radon (86)
Rn-222 (a) 3x10-1 4x10-3 1x101(b) 1x108(b)
Ruthenium (44)
Ru-97 5x100 5x100 1x102 1x107 Ru-103 (a) 2x100 2x100 1x102 1x106 Ru-105 1x100 6x10-1 1x101 1x106 Ru-106 (a) 2x10-1 2x10-1 1x102(b) 1x105(b)
Sulfur (16)
S-35 4x101 3x100 1x105 1x108 Antimony (51)
Sb-122 4x10-1 4x10-1 1x102 1x104 Sb-124 6x10-1 6x10-1 1x101 1x106 Sb-125 2x100 1x100 1x102 1x106 Sb-126 4x10-1 4x10-1 1x101 1x105 Scandium (21)
Sc-44 5x10-1 5x10-1 1x101 1x105 Sc-46 5x10-1 5x10-1 1x101 1x106 Sc-47 1x101 7x10-1 1x102 1x106 Sc-48 3x10-1 3x10-1 1x101 1x105
Selenium (34)
Se-75 3x100 3x100 1x102 1x106 Se-79 4x101 2x100 1x104 1x107 Silicon (14)
Si-31 6x10-1 6x10-1 1x103 1x106 Si-32 4x101 5x10-1 1x103 1x106 Samarium (62)
Sm-145 1x101 1x101 1x102 1x107 Sm-147 Unlimited Unlimited 1x101 1x104 Sm-151 4x101 1x101 1x104 1x108 Sm-153 9x100 6x10-1 1x102 1x106 Tin (50)
Sn-113 (a) 4x100 2x100 1x103 1x107 Sn-117m 7x100 4x10-1 1x102 1x106 Sn-119m 4x101 3x101 1x103 1x107 Sn-121m (a) 4x101 9x10-1 1x103 1x107 Sn-123 8x10-1 6x10-1 1x103 1x106 Sn-125 4x10-1 4x10-1 1x102 1x105 Sn-126 (a) 6x10-1 4x10-1 1x101 1x105 Strontium (38)
Sr-82 (a) 2x10-1 2x10-1 1x101 1x105 Sr-85 2x100 2x100 1x102 1x106 Sr-85m 5x100 5x100 1x102 1x107 Sr-87m 3x100 3x100 1x102 1x106 Sr-89 6x10-1 6x10-1 1x103 1x106 Sr-90 (a) 3x10-1 3x10-1 1x102(b) 1x104(b)
Sr-91 (a) 3x10-1 3x10-1 1x101 1x105 Sr-92 (a) 1x100 3x10-1 1x101 1x106 Tritium (1)
T(H-3) 4x101 4x101 1x106 1x109 Tantalum (73)
Ta-178 (with long half-life) 1x100 8x10-1 1x101 1x106 Ta-179 3x101 3x101 1x103 1x107 Ta-182 9x10-1 5x10-1 1x101 1x104 Terbium (65)
Tb-157 4x101 4x101 1x104 1x107 Tb-158 1x100 1x100 1x101 1x106 Tb-160 1x100 6x10-1 1x101 1x106 Technetium (43)
Tc-95m (a) 2x100 2x100 1x101 1x106 Tc-96 4x10-1 4x10-1 1x101 1x106 Tc-96m (a) 4x10-1 4x10-1 1x103 1x107 Tc-97 Unlimited Unlimited 1x103 1x108 Tc-97m 4x101 1x100 1x103 1x107 Tc-98 8x10-1 7x10-1 1x101 1x106 Tc-99 4x101 9x10-1 1x104 1x107 Tc-99m 1x101 4x100 1x102 1x107
Tellurium (52)
Te-121 2x100 2x100 1x101 1x106 Te-121m 5x100 3x100 1x102 1x106 Te-123m 8x100 1x100 1x102 1x107 Te-125m 2x101 9x10-1 1x103 1x107 Te-127 2x101 7x10-1 1x103 1x106 Te-127m (a) 2x101 5x10-1 1x103 1x107 Te-129 7x10-1 6x10-1 1x102 1x106 Te-129m (a) 8x10-1 4x10-1 1x103 1x106 Te-131m (a) 7x10-1 5x10-1 1x101 1x106 Te-132 (a) 5x10-1 4x10-1 1x102 1x107 Thorium (90)
Th-227 1x101 5x10-3 1x101 1x104 Th-228 (a) 5x10-1 1x10-3 1x100(b) 1x104(b)
Th-229 5x100 5x10-4 1x100(b) 1x103(b)
Th-230 1x101 1x10-3 1x100 1x104 Th-231 4x101 2x10-2 1x103 1x107 Th-232 Unlimited Unlimited 1x101 1x104 Th-234 (a) 3x10-1 3x10-1 1x103(b) 1x105(b)
Th (natural)
Unlimited Unlimited 1x100(b) 1x103(b)
Titanium (22)
Ti-44 (a) 5x10-1 4x10-1 1x101 1x105 Thallium (81)
Tl-200 9x10-1 9x10-1 1x101 1x106 Tl-201 1x101 4x100 1x102 1x106 Tl-202 2x100 2x100 1x102 1x106 Tl-204 1x101 7x10-1 1x104 1x104 Thulium (69)
Tm-167 7x100 8x10-1 1x102 1x106 Tm-170 3x100 6x10-1 1x103 1x106 Tm-171 4x101 4x101 1x104 1x108 Uranium (92)
U-230 (rapid lung retention) (a)(d) 4x101 1x10-1 1x101(b) 1x105(b)
U-230 (medium lung retention) (a)(e) 4x101 4x10-3 1x101 1x104 U-230 (slow lung retention) (a)(f) 3x101 3x10-3 1x101 1x104 U-232 (rapid lung retention) (d) 4x101 1x10-2 1x100(b) 1x103(b)
U-232 (medium lung retention) (e) 4x101 7x10-3 1x101 1x104 U-232 (slow lung retention) (f) 1x101 1x10-3 1x101 1x104 U-233 (rapid lung retention) (d) 4x101 9x10-2 1x101 1x104 U-233 (medium lung retention) (e) 4x101 2x10-2 1x102 1x105 U-233 (slow lung retention) (f) 4x101 6x10-3 1x101 1x105 U-234 (rapid lung retention) (d) 4x101 9x10-2 1x101 1x104 U-234 (medium lung retention) (e) 4x101 2x10-2 1x102 1x105 U-234 (slow lung retention) (f) 4x101 6x10-3 1x101 1x105 U-235 (all types of lung retention)
(a)(d)(e)(f)
Unlimited Unlimited 1x101(b) 1x104(b)
U-236 (quick retention) (d)
Unlimited Unlimited 1x101 1x104
U-236 (medium retention rate) (e) 4x101 2x10-2 1x102 1x105 U-236 (slow retention) (f) 4x101 6x10-3 1x101 1x104 U-238 (all types of lung retention)
(d)(e)(f)
Unlimited Unlimited 1x101(b) 1x104(b)
U (natural)
Unlimited Unlimited 1x100(b) 1x103(b)
U (enriched up to 20 % or less) (g)
Unlimited Unlimited 1x100 1x103 U (depleted)
Unlimited Unlimited 1x100 1x103 Vanadium (23)
V-48 4x10-1 4x10-1 1x101 1x105 V-49 4x101 4x101 1x104 1x107 Wolfram (74)
W-178 (a) 9x100 5x100 1x101 1x106 W-181 3x101 3x101 1x103 1x107 W-185 4x101 8x10-1 1x104 1x107 W-187 2x100 6x10-1 1x102 1x106 W-188 (a) 4x10-1 3x10-1 1x102 1x105 Xenon (54)
Xe-122 (a) 4x10-1 4x10-1 1x102 1x109 Xe-123 2x100 7x10-1 1x102 1x109 Xe-127 4x100 2x100 1x103 1x105 Xe-131m 4x101 4x101 1x104 1x104 Xe-133 2x101 1x101 1x103 1x104 Xe-135 3x100 2x100 1x103 1x1010 Yttrium (39)
Y-87 (a) 1x100 1x100 1x101 1x106 Y-88 4x10-1 4x10-1 1x101 1x106 Y-90 3x10-1 3x10-1 1x103 1x105 Y-91 6x10-1 6x10-1 1x103 1x106 Y-91m 2x100 2x100 1x102 1x106 Y-92 2x10-1 2x10-1 1x102 1x105 Y-93 3x10-1 3x10-1 1x102 1x105 Ytterbium (70)
Yb-169 4x100 1x100 1x102 1x107 Yb-175 3x101 9x10-1 1x103 1x107 Zinc (30)
Zn-65 2x100 2x100 1x101 1x106 Zn-69 3x100 6x10-1 1x104 1x106 Zn-69m (a) 3x100 6x10-1 1x102 1x106 Zirconium (40)
Zr-88 3x100 3x100 1x102 1x106 Zr-93 Unlimited Unlimited 1x103(b) 1x107(b)
Zr-95 (a) 2x100 8x10-1 1x101 1x106 Zr-97 (a) 4x10-1 4x10-1 1x101(b) 1x105(b)
Legend:
(a) For the listed parent radionuclides, the values A1 and A2 include contributions from radioactive decay products with a decay half-life of less than 10 days:
Mg-28 Al-28 Ar-42 K-42 Ca-47 Sc-47
Ti-44 Sc-44 Fe-52 Mn-52m Fe-60 Co-60m Zn-69m Zn-69 Ge-68 Ga-68 Rb-83 Kr-83m Sr-82 Rb-82 Sr-90 Y-90 Sr-91 Y-91m Sr-92 Y-92 Y-87 Sr-87m Zr-95 Nb-95m Zr-97 Nb-97m, Nb-97 Mo-99 Tc-99m Tc-95m Tc-95 Tc-96m Tc-96 Ru-103 Rh-103m Ru-106 Rh-106 Pd-103 Rh-103m Ag-108m Ag-108 Ag-110m Ag-110 Cd-115 In-115m In-114m In-114 Sn-113 In-113m Sn-121m Sn-121 Sn-126 Sb-126m Te-118 Sb-118 Te-127m Te-127 Te-129m Te-129 Te-131m Te-131 Te-132 I-132 I-135 Xe-135m Xe-122 I-122 Cs-137 Ba-137m Ba-131 Cs-131 Ba-140 La-140 Ce-144 Pr-144m, Pr-144 Pm-148m Pm-148 Gd-146 Eu-146 Dy-166 Ho-166 Hf-172 Lu-172 W-178 Ta-178 W-188 Re-188 Re-189 Os-189m Os-194 Ir-194 Ir-189 Os-189m Pt-188 Ir-188 Hg-194 Au-194 Hg-195m Hg-195 Pb-210 Bi-210 Pb-212 Bi-212, Tl-208, Po-212 Bi-210m Tl-206 Bi-212 Tl-208, Po-212 At-211 Po-211 Rn-222 Po-218, Pb-214, At-218, Bi-214, Po-214 Ra-223 Rn-219, Po-215, Pb-211, Bi-211, Po-211, Tl-207 Ra-224 Rn-220, Po-216, Pb-212, Bi-212, Tl-208, Po-212 Ra-225 Ac-225, Fr-221, At-217, Bi-213, Tl-209, Po-213, Pb-209 Ra-226 Rn-222, Po-218, Pb-214, At-218, Bi-214, Po-214 Ra-228 Ac-228
Ac-225 Fr-221, At-217, Bi-213, Tl-209, Po-213, Pb-209 Ac-227 Fr-223 Th-228 Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208, Po-212 Th-234 Pa-234m, Pa-234 Pa-230 Ac-226, Th-226, Fr-222, Ra-222, Rn-218, Po-214 U-230 Th-226, Ra-222, Rn-218, Po-214 U-235 Th-231 Pu-241 U-237 Pu-244 U-240, Np-240m Am-242m Am-242, Np-238 Am-243 Np-239 Cm-247 Pu-243 Bk-249 Am-245 Cf-253 Cm-249 (b) Parent radionuclides and products of their radioactive decay corresponding to permanent equilibrium:
Sr-90 Y-90 Zr93 Nb-93m Zr-97 Nb-97 Ru-106 Rh-106 Ag-108m Ag-108 Cs-137 Ba-137m Ce-144 Pr-144 Ba-140 La-140 Bi-212 Tl-208 (0.36), Po-212 (0.64)
Pb-210 Bi-201, Po-210 Pb-212 Bi-212, Tl-208 (0.36), Po-212 (0.64)
Rn-222 Po-218, Pb-214, Bi-214, Po-214 Ra-223 Rn-219, Po-215, Pb-211, Bi-211, Tl-207 Ra-224 Rn-220, Po-216, Pb-212, Bi-212, Tl-208 (0.36), Po-212 (0.64)
Ra-226 Rn-222, Po-218, Pb-214, Bi-214, Po-214, Pb-210, Bi-210, Po-210 Ra-228 Ac-228 Th-228 Ra-224, Rn-220, Po-216, Pb212, Bi-212, Tl208 (0.36), Po-212 (0.64)
Th-229 Ra-225, Ac-225, Fr-221, At-217, Bi-213, Po-213, Pb-209 Th natural Ra-228, Ac-228, Th-228, Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208(0.36), Po-212(0.64)
Th-234 Pa-234m U-230 Th-226, Ra-222, Rn-218, Po-214 U-232 Th-228, Ra-224, Rn-220, Po-216, Pb-212, Bi-212, Tl-208 (0.36), Po-212 (0.64)
U-235 Th-231 U-238 Th-234, Pa-234m U natural Th-234, Pa-234m, U-234, Th-230, Ra-226, Rn-222, Po-218, Pb-214, Bi-214, Po-214, Pb-210, Bi-210, Po-210 Np-237 Pa-233 Am-242m Am-242 Am-243 Np-239 (c) Activity may be determined from a measurement of the rate of decay or a measurement of the radiation level at a prescribed distance from the radionuclide source of ionising radiation.
(d) These values apply only to uranium compounds UF6, U2F2 and UO2(NO3)2 in both normal and accident conditions of transport.
(d) These values apply only to uranium compounds UO3, UF4, UCl4 and hexavalent uranium compounds in both normal and accident conditions of transport.
(f) These values apply to all compounds of uranium other than those specified in (d) and (e).
(g) These values apply to unirradiated uranium only.
- 3. DETERMINATION OF BASIC RADIONUCLIDE VALUES
- 3.
- 1. For a radionuclide not listed in Table 2, specific activity limits for material exception and activity limits for package exception shall be calculated in accordance with principles and methods stipulated in Annex 6 to this decree, or
values in Table 3 shall be used. The value of A2 may also be calculated using the dose coefficient for the relevant lung absorption type, according to International Atomic Energy Agency recommendations, where the calculation shall take into account the chemical form of each radionuclide under normal conditions of transport and under accident conditions of transport.
- 2. For a radionuclide enclosed or contained in an instrument or product that meets the requirements of Point 23(c), an alternative basic value may be used to the basic value for the specific activity limit for material exception listed in Table 2.
This alternative value shall be calculated in accordance with procedures and methods described in Annex 6 to this decree.
- 4.
In the calculations of A1 a A2 for a radionuclide not in Table 2:
a) a single radioactive decay chain in which the radionuclides are present in their naturally occurring proportions, and in which no daughter nuclide has a half-life either longer than 10 days or longer than that of the parent nuclide shall be considered as a single radionuclide; and the activity to be taken into account and the A1 and A2 values to be applied shall be those corresponding to the parent nuclide of that chain; or b) a radioactive decay chain in which any daughter nuclide has a half-life either longer than 10 days or greater than that of the parent nuclide, the parent and such daughter nuclides shall be considered as mixtures of different nuclides.
- 5.
For mixtures of radionuclides for which basic radionuclide values are provided in Table 2, basic values shall be determined using the formula:
i m
i X
i f
X
)
(
)
(
1 Where f(i) is the fraction of activity or activity concentration of radionuclide i in the mixture; X(i) is the appropriate value of A1 or A2 or the activity concentration for exempt material or the activity limit for an exempt consignment for the relevant radionuclide i; and Xm is the basic value derived for a mixture from A1 or A2, or the activity concentration for exempt material or the activity limit for an exempt consignment.
- 6.
When the identity of each radionuclide is known but the individual activities of some of the radionuclides are not known, the radionuclides may be grouped according to the type of emitted radiation (alpha, beta, or gamma) with known overall activities for the given group, and calculations may be performed according to formulas in Points 5 and 30 using appropriate lowest radionuclide values from A1, A2,, specific activity limits for exempt material, or activity limits for the exempt consignment in each group. For groups based on total alpha activity, the lowest radionuclide values for alpha emitters in the given group shall be used. For groups based on the total beta or gamma activity, the lowest radionuclide values for radionuclide sources emitting beta or gamma radiation (hereinafter an beta or gamma emitter) in the given group shall be used.
- 7.
For radionuclides or for mixtures of radionuclides for which relevant data for the use of Table 2 is not available, the values shown in Table 3 shall be used.
Table 3 Basic radionuclide values for unknown radionuclides or mixtures Radioactive contents A1 A2 Activity concentratio n limits for exception of material Activity limits for an exempt consignment
[TBq]
[TBq]
[Bq/g]
[Bq]
Only beta or gamma emitters are known to be present 0.1 0.02 1x101 1x104 Alpha emitters are known to be present, but radionuclide sources emitting neutrons are not known to be present 0.2 9x10-5 1x10-1 1x103 Radionuclide sources emitting neutrons are known to be present or no relevant data are available 0.001 9x10-5 1x10-1 1x103
- 4. MATERIAL CLASSIFICATION 4.1. Materials with low specific activity
- 8.
A radioactive or fissile material is classified as material with low specific activity if a) it conforms to the definition in § 2(j);
b) it meets the requirements of Points 9 to 11; and c) it meets relevant requirements of Points 17 to 22 of Annex 4 to this decree.
- 9.
- 1. A material with low specific activity is classified in group LSA-I, LSA-II, or LSA-III.
- 2. Group LSA-I includes:
a) uranium and thorium ores, their concentrates, and other ores containing naturally occurring radionuclides; b) natural or depleted uranium, natural thorium or their compounds or mixtures, which have not been irradiated and are in solid or liquid form; c) a radioactive material for which A2 is unlimited; of fissile material, only an exempt fissile material may be included; and d) other radioactive material in which activity is uniformly distributed throughout their volume, and the calculated mean specific activity does not exceed 30 times the specific activity limit for material exemption stipulated pursuant to Points 2 and 7, where external shielding materials surrounding the LSA material are not taken into account in determining the mean specific activity; of fissile material, only an exempt fissile material may be included.
- 3. Group LSA-II includes:
a) water with tritium with concentration up to 0.8 TBq/l; and
b) other materials in which activity is uniformly distributed throughout their volume, and the calculated mean specific activity does not exceed 10-4 A2/g for solids and gases and 10-5 A2/g for liquids, where external shielding materials surrounding the LSA material are not taken into account in determining the mean specific activity.
- 4. Group LSA-III includes solids, except for powdered materials, that meet the requirements of Point 1 of Part I of Annex 1 to this decree, and in which:
a) the radioactive or fissile material is uniformly distributed throughout the volume of the solid material or in an array of several solid objects, or is relatively uniformly distributed in a compact bonding agent; b) the radioactive or fissile material is relatively insoluble or is contained in a relatively insoluble matrix in such a manner that even in the event of loss of packaging, the loss of radioactive or fissile material from one package through leaching in water for 7 days does not exceed 0.1 A2; and c) the calculated mean specific activity of solid material without shielding does not exceed 2.10-3 A2/g, where external shielding materials surrounding the LSA material are not taken into account in determining the mean specific activity.
- 10.
A package with non-flammable solid material of group LSA-II or LSA-III must not contain activity greater than 3 000 A2 when being transported by air.
- 11.
The radioactive contents in a single package of LSA material shall be so restricted that the radiation level specified in Point 17 of Annex 4 to this decree shall not be exceeded, and the activity in a single package shall be so restricted that the activity limits for a conveyance specified in Point 22 of Annex 4 to this decree shall not be exceeded.
4.2. Surface contaminated object
- 12.
A radioactive or fissile material is classified as a surface contaminated object (SCO) if:
a) it conforms to the definition in § 2(m);
b) it meets the requirements of Points 13 and 14; and c) it meets relevant requirements of Points 17 to 22 of Annex 4 to this decree.
- 13.
- 1. A surface contaminated object is classified in group SCO-I or SCO-II.
- 2. Group SCO-I includes a solid object for which:
a) non-fixed contamination on the accessible surface averaged over 300 cm2 (or the entire surface if less than 300 cm2) does not exceed:
- 1. 4 Bq/cm2 for beta and gamma emitters and low toxicity alpha emitters;
- 2. or 0.4 Bq/cm2 for all other alpha emitters; b) fixed contamination on the accessible surface averaged over 300 cm2 (or the entire surface if less than 300 cm2) does not exceed:
- 1. 4.104 Bq/cm2 for beta and gamma emitters and low toxicity alpha emitters, or
- 2. 4.103 Bq/cm2 for all other alpha emitters; and c) the sum of fixed and non-fixed contamination on the accessible surface averaged over 300 cm2 (or the entire surface if less than 300 cm2) does not exceed:
- 1. 4.104 Bq/cm2 for beta and gamma emitters and low toxicity alpha emitters, or
- 2. 4.103 Bq/cm2 for all other alpha emitters.
- 3. Group SCO-II includes a solid object on which either the fixed or non-fixed contamination on the surface exceeds the applicable limits specified in (2) and for which:
a) non-fixed contamination on the accessible surface averaged over 300 cm2 (or the entire surface if less than 300 cm2) does not exceed:
- 1. 400 Bq/cm2 for beta and gamma emitters and low toxicity alpha emitters;
- 2. 40 Bq/cm2 for all other alpha emitters; b) fixed contamination on the accessible surface averaged over 300 cm2 (or the entire surface if less than 300 cm2) does not exceed:
- 1. 8.105 Bq/cm2 for beta and gamma emitters and low toxicity alpha emitters, or
- 2. 8.104 Bq/cm2 for all other alpha emitters; and c) the sum of fixed and non-fixed contamination on the accessible surface averaged over 300 cm2 (or the entire surface if less than 300 cm2) does not exceed:
- 1. 8.105 Bq/cm2 for beta and gamma emitters and low toxicity alpha emitters, or
- 2. 8.104 Bq/cm2 for all other alpha emitters.
- 14.
The radioactive contents in a package with an SCO shall be so restricted that the radiation level specified in Point 17 of Annex 4 to this decree shall not be exceeded, and the activity in a single package shall be so restricted that the activity limits for a conveyance specified in Point 22 of Annex 4 to this decree shall not be exceeded.
4.3. Special form radioactive material
- 15.
A radioactive or fissile material is classified as a special form radioactive material if:
a) it meets the requirements of Points 2 to 4 of Part I of Annex 1 to this decree, and b) it is type-approved as a special form radioactive material pursuant to
§ 137(1)(b) of the Atomic Act.
4.4. Low dispersible radioactive material
- 16.
A radioactive or fissile material is classified as a slow dispersible radioactive material if:
a) it meets the requirements of Point 5 of Part I of Annex 1 to this decree; b) it is type-approved as a low dispersible radioactive material pursuant to
§ 137(1)(c) of the Atomic Act; and c) the package containing it meets the requirements of Point 65 of Part I of Annex 1 to this decree.
4.5. Fissile material
- 17.
Fissile material and a package containing fissile material shall be classified as FISSILE MATERIAL under the relevant entry in Table 1. Assuming that they are
transported in packages that meet the requirements of Point 36 of Part I of Annex 1 to this decree, and pursuant to the requirements of Point 70 of Annex 4 to this decree, the following are exempt from the above requirement:
a) uranium enriched with 235U to a maximum of 1 % by mass, and with a total plutonium and 233U content not exceeding 1 % of the mass of 235U provided that the fissile nuclides are distributed essentially homogeneously throughout the material. If 235U is present in metallic, oxide or carbide forms, it shall not form a lattice arrangement.
b) liquid solutions of uranyl nitrate enriched with 235U to a maximum of 2 % by mass, with a total plutonium and 233U content not exceeding 0.002 % of the mass of uranium, and with a minimum nitrogen (N) to uranium (U) atomic ratio of 2 (2 N/U);
c) uranium enriched with 235U to a maximum of 5 % by mass, assuming:
- 1. the mass of 235U is no greater than 3.5 g per package;
- 2. total plutonium and 233U content does not exceed 1 % of the mass of 235U per package; and
- 3. transport of the package is restricted by limits for a consignment specified in Point 70(c) of Annex 4 to this decree; d) fissile radionuclides with total mass not exceeding 2 g per package, assuming that transport of the package is restricted by limits for a consignment specified in Point 70(d) of Annex 4 to this decree; e) fissile radionuclides with a total mass not exceeding 45 g in packaging or unpackaged, assuming that transport is restricted by limits for a consignment specified in Point 70(e) of Annex 4 to this decree; and f) fissile materials that meet the requirements of Point 70(b) of Annex 4 to this decree and Point 6 of Part I of Annex 1 to this decree; if they are transported, except for unpackaged fissile radionuclides pursuant to (e),
in a package whose smallest external overall dimension is greater than or equal to 10 cm.
- 18.
The contents of a package containing fissile material must meet the requirements stipulated for package design by this decree or a type approval decision.
4.6. Uranium hexafluoride
- 19.
Uranium hexafluoride is classified under one of the following UN numbers:
a) UN 2977, RADIOACTIVE MATERIAL, URANIUM HEXAFLUORIDE, FISSILE MATERIAL; b) UN 2978, RADIOACTIVE MATERIAL, URANIUM HEXAFLUORIDE, exempt fissile material or non-fissile material; c) UN 3507 URANIUM HEXAFLUORIDE, RADIOACTIVE MATERIAL, PACKAGE EXCEPTIONS - less than 0.1 kg in package, exempt fissile material or non-fissile material.
- 20.
Packages containing uranium hexafluoride shall comply with the following:
a) the mass of uranium hexafluoride shall correspond to this permitted mass for the given package type; b) the mass of uranium hexafluoride shall not be greater than a value that would lead to an ullage smaller than 5 % at the maximum temperature of the package as specified for facilities where the package shall be used; and
c) the uranium hexafluoride shall be in solid form and the internal pressure shall not be greater than atmospheric pressure when handed over for carriage.
- 5. CLASSIFICATION OF PACKAGES
- 21.
The quantity of radioactive or fissile material in a package shall not exceed the relevant limits for the given package type in Points 22 to 33.
5.1. Classification as a package exception
- 22.
A packages is classified as a package exception if:
a) it is an empty package that had contained radioactive material; b) it contains an instrument or product whose activity does not exceed limits specified in Table 4; c) it contains a product manufactured from natural uranium, depleted uranium, or natural thorium; d) it contains a radioactive material whose activity does not exceed the limits specified in Table 4; or e) it contains less than 0.1 kg of uranium hexafluoride, whose activity does not exceed the limits specified in the column Materials - Package limits in Table 4.
Table 4 Activity limits for package exception Physical state of contents (phase)
Device or product Materials -
Package limitsa)
Item limitsa)
Package limitsa)
Solids:
special form radioactive material 10-2A1 A1 10-3A1 radioactive material other than special form 10-2A2 A2 10-3A2 Liquid 10-3A2 10-1A2 10-4A2 Gases:
Tritium (3H) 2x10-2A2 2x10-1A2 2x10-2A2 special form radioactive material 10-3A1 10-2A1 10-3A1 radioactive material other than special form 10-3A2 10-2A2 10-3A2 Legend:
a) For mixtures of radionuclides, see Points 4 to 6.
- 23.
- 1. Radioactive material that is enclosed in or contained in an instrument or product may be classified under UN 2911, RADIOACTIVE MATERIAL, PACKAGE EXCEPTION - DEVICES or PRODUCTS, if:
a) the radiation level at 10 cm from any point on the external surface of any unpackaged instrument or product is less than or equal to 0.1 mSv/h; b) each device or product is marked 'RADIOACTIVE'. Marking is not required for:
- 1. the faces of timepieces or other devices marked with radioluminescent paint;
- 2. consumer products that have either received type approval from the Office or do not individually exceed the activity limit for an exempt
consignment in the column marked Activity limit for an exempt consignment [Bq] in Table 2, provided that they are transported in a package that is marked RADIOACTIVE on an internal surface in such a manner that it is visible when the package is opened; and
- 3. other devices or products that are too small to be marked with RADIOACTIVE, if they are transported in packaging that is marked RADIOACTIVE on an internal surface in such a manner that is visible when the package is opened; c) the radioactive material is completely enclosed by a non-active compound; a device performing the sole function of containing radioactive material shall not be considered to be an instrument or product pursuant to Point 23; and d) the activity limits specified in the column Item limits in Table 4 are met for an instrument or product, and the activity limits specified in the column Package limits in Table 4 are met for a package.
- 24.
Radioactive material in forms other than as specified in Point 23 and with an activity not exceeding the limits specified in the column Materials - Package limits of Table 4 is classified under UN 2910, RADIOACTIVE MATERIAL, PACKAGE EXCEPTION - LIMITED QUANTITY OF MATERIAL, provided that:
a) the package retains its radioactive contents under routine conditions of transport; and b) the package is marked RADIOACTIVE
- 1. on an internal surface in such a manner that is visible when the package is opened, or
- 2. elsewhere than on the package if marking the internal surface is not feasible.
- 25.
Uranium hexafluoride, if its activity does not exceed the limits specified in the column Materials - Package limits of Table 4 is classified under UN 3507 URANIUM HEXAFLUORIDE, RADIOACTIVE MATERIAL, PACKAGE EXCEPTION - less than 0.1 kg in the package, exempt fissile material or non-fissile material, if:
a) the mass of uranium hexafluoride in the package is less than 0.1 kg, and b) the requirements of Points 20 and 24 are met.
- 26.
Articles manufactured of natural uranium, depleted uranium or natural thorium and articles in which the sole radioactive material is unirradiated natural uranium, unirradiated depleted uranium or unirradiated natural thorium may be classified under UN 2909, RADIOACTIVE MATERIAL, PACKAGE EXCEPTION -
PRODUCTS MADE FROM NATURAL URANIUM or DEPLETED URANIUM or THORIUM, if the outer surface of the uranium or thorium is enclosed in an inactive sheath made of metal or some other substantial material.
5.2. Additional requirements and controls for transport of empty packagings
- 27.
An empty packaging that had previously contained radioactive material may be classified under UN
- 2908, RADIOACTIVE
- MATERIAL, PACKAGE EXCEPTION - EMPTY PACKAGING, if:
a) it is defect-free condition and securely closed;
b) the outer surface of any uranium or thorium in its structure is covered with an inactive sheath made of metal or some other substantial material; c) the level of internal non-fixed contamination does not exceed one hundred times the limits specified in Point 8 of Annex 4 to this decree; and d) any labels which may have been displayed on it in conformity with Point 38 of Annex 4 to this decree are no longer visible.
5.3. Classification as a Type A radioactive package
- 28.
A package containing radioactive or fissile material is classified as a Type A package if it adheres to the requirements of Points 29 and 30.
- 29.
Type A packages shall not contain activities greater than the following::
a) A1 for special form radioactive material; and b) A2 for radioactive material other than special form.
- 30.
For mixtures of radionuclides whose identities and activities are known, the following condition shall apply to the radioactive contents of a Type A package:
where B(i) is the activity of radionuclide i as special form radioactive material; A1(i) value of A1 for radionuclide i; C(j) is the activity of radionuclide j as other than special form radioactive material; and A2(j) is the value of A2 for radionuclide j.
5.4. Classification as a Type B(U), B(M), and C radioactive package
- 31.
A Type B(U), Type B(M) and Type C package shall be classified in accordance with a type approval decision issued by the Office or in accordance with document issued by a competent authority of the country of origin of design.
- 32.
A Type B(U), Type B(M) and Type C package shall meet specifications in a type approval decision issued by the Office or specifications in a document issued by a competent authority of the country of origin of the design.
- 33.
A Type B(U) and Type B(M) package, if transported by air, shall meet the requirements of Point 32 and shall not contain activities greater than the following:
a) for low dispersible radioactive material, activity values approved for the given design; b) for special form radioactive material, 3 000 A1 or 100 000 A2, whichever is less; c) for other than special form radioactive material, 3000 A2.
- 6. TRANSPORT UNDER SPECIAL ARRANGEMENTS
- 34.
Radioactive or fissile material shall be classified as transported under special arrangements if it is carried pursuant to § 9(4)(c) of the Atomic Act.
Annex 4 to Decree No TECHNICAL AND ORGANISATIONAL CONDITIONS OF CARRIAGE AND TRANSPORT OF RADIOACTIVE OR FISSILE MATERIAL
- 1. REQUIREMENTS BEFORE THE FIRST SHIPMENT
- 1.
Before a packaging is first used to transport radioactive or fissile material:
a) it shall be confirmed that it has been manufactured in conformity with design specifications, and b) meets the following requirements:
- 1. if the design pressure of the containment system exceeds 35 kPa, the containment system of each packaging shall conform to approved design requirements relating to the capability of that system to maintain its integrity under that pressure;
- 2. the effectiveness of shielding and containment and, where necessary, the heat transfer characteristics and the effectiveness of the confinement system of packaging intended for use as a Type B(U), Type B(M) or Type C package and packaging intended for the carriage of fissile material shall be within the limits of the approved design; and
- 3. packaging intended for the carriage of fissile material it shall be capable of ensuring effectiveness of the criticality safety features within the limits applicable to or specified for the design. Where, in order to comply with the requirements of Point 73 of Part I of Annex 1 to this decree, neutron poisons are included in the packaging, checks shall be performed to confirm the presence and distribution of those neutron poisons.
- 2. REQUIREMENTS BEFORE EACH SHIPMENT
- 2.
Before shipment of a package, it shall be ensured that it contain:
a) radionuclides different from those specified for the package design; and b) contents in a form, or physical or chemical state, different from those specified for the package design.
- 3.
Before shipment of a package:
a) lifting attachments that do not meet the requirements of Point 8 of Part I of Annex 1 to this decree shall be removed or otherwise rendered incapable of being used for lifting the package, in accordance with Point 9 of Part I of Annex 1 to this decree; b) a Type B(U), Type B(M) and Type C package shall achieve equilibrium conditions sufficient to demonstrate compliance with the requirements for temperature and pressure, pursuant to the packaging type approval decision issued by the Office or a relevant authority of the state of origin of the packaging; c) closures, valves or other openings of the containment system through which the radioactive contents of a Type B(U), B(M) or C package might escape are closed and, where feasible, sealed in a manner where checks or suitable tests
are capable of demonstrating compliance with the requirements of Points 59 and 71 of Part I of Annex 1 to this decree; and d) for a package containing fissile material, the measurements specified in Point 77(b) of Part I of Annex 1 to this decree and the tests to demonstrate closure of the package as specified in Point 80 of Part I of Annex 1 to this decree shall be performed.
- 3. TRANSPORT OF OTHER GOODS
- 4.
A package may contain only instruments necessary for the handling of the radioactive content. The interaction between these instruments and the package, under the conditions of transport applicable to its design, shall not reduce the its safety.
- 5.
Freight containers, IBCs, packagings, and overpacks used for the transport of radioactive or fissile material may be used for the storage or transport of other goods if after their decontamination, the value of non-fixed surface contamination:
a) is less than 0.4 Bq/cm2 for beta and gamma emitters and low-toxicity alpha emitters; and b) is less than 0.04 Bq/cm2 for all other alpha emitters.
- 6.
A consignment shall be segregated from other dangerous goods during transport in compliance with the relevant regulations for carriage of dangerous goods of the country of origin, transit and destination; regulations of a qualified carrier may also be used if they ensure the same or a greater level of protection.
- 4. OTHER DANGEROUS PROPERTIES OF CONTENTS
- 7.
Any other dangerous properties of the contents of the package, such as explosiveness, flammability, pyrophoricity, chemical toxicity and corrosiveness, shall be taken into account in the packing, labelling, marking, placarding, storage and transport.
- 5. REQUIREMENTS FOR DETECTING CONTAMINATION AND FOR SECURING LEAKING PACKAGES
- 8.
The non-fixed contamination on the external surfaces of a package shall be kept as low as practicable and, under routine conditions of transport, shall not exceed the following limits:
a) 4.0 Bq/cm2 for gamma and beta emitters and low-toxicity alpha emitters; and b) 0.4 Bq/cm2 for all other alpha emitters; these limits are applicable when averaged over any area of 300 cm² of any part of the surface.
- 9.
The level of non-fixed contamination on the external and internal surfaces of a freight container, IBC, packaging, and overpack shall not exceed the limits specified in Point 8.
- 10.
If there is suspicion or it is evident that a package is damaged or that radioactive contents are leaking, access to the package shall be restricted and a qualified person shall assess the extent of contamination and the resultant radiation level of the package. The assessment shall include the package, the conveyance, the adjacent loading and unloading areas and, if necessary, all other material that has been carried on or in the conveyance.
- 11.
A damaged package or a package leaking radioactive contents in excess of allowable limits for normal conditions of transport shall be repaired or otherwise restored to a functional state and decontaminated prior to being forwarded for further carriage. Until it is forwarded for further carriage, it may be temporarily placed in a monitored location.
- 12.
A conveyance and equipment used regularly for the transport of radioactive or fissile material shall be periodically checked to determine the level of contamination. The frequency of such checks shall be correspond to the likelihood of contamination and the extent to which radioactive or fissile material is being transported.
- 13.
A conveyance, part thereof, or equipment that has become contaminated above the limits specified in Point 8 during the transport of radioactive or fissile material, or that shows a radiation level in excess of 5 Sv/h, shall be decontaminated by a qualified person. They may be reused if:
a) non-fixed contamination does not exceed the limits specified in Point 8; b) the radiation level resulting from fixed contamination does not exceed 5 Sv/h on the external surface.
- 14.
A freight container, tank, IBC or conveyance dedicated to the transport of unpackaged material under exclusive use shall be excepted from the requirements for non-fixed contamination on the internal surface of Points 9 and 13 for as long as it remains under exclusive use.
- 6. REQUIREMENTS AND CONTROLS FOR TRANSPORT OF PACKAGE EXCEPTIONS
- 15.
- 1. A package exception need only meet the requirements of Points 3 to 5, 7 to 13, 16, 30 to 33, 45, 46 introductory sentence, 46(a), 46(k), 50, 53, 55, 56, 61, 64, 82 and 83; all other relevant requirements of this decree shall be met.
- 2. If the package exception contains fissile material, one of the conditions in Point 17(a) to (f) of Annex 3 to this decree for an exempt fissile material must be met.
- 16.
The radiation level at any point on the external surface of a package exception shall not exceed 5 Sv/h.
- 7. REQUIREMENTS AND CONTROLS FOR TRANSPORT OF LSA MATERIAL AND SCO ITEMS IN INDUSTRIAL PACKAGES OR UNPACKAGED
- 17.
The quantity of LSA material or SCO in a single Type IP-1, IP-2, IP-3 package, or object or collection of objects shall be so restricted that the external radiation level at 3 m from the unshielded material or object or collection of objects does not exceed 10 mSv/h.
- 18.
LSA material and SCO that are or contain fissile material that do not meet conditions for use in one of the exceptions pursuant to Point 17(a) to (f) of Annex 3 to this decree for an exempt fissile material shall meet the applicable requirements of Points 68 and 69.
- 19.
LSA material and SCO that are or contain fissile material shall meet the applicable requirements of Point 73.
- 20.
LSA material and SCO in groups LSA-I and SCO-I may be transported, unpackaged, under the following conditions:
a) other than ores containing only naturally occurring radionuclides, they are transported in such a manner that under routine conditions of transport there will be no escape of the radioactive contents from the conveyance nor loss of shielding; b) they conveyance shall be under exclusive use, except when only transporting SCO-I on which the contamination on the accessible and the inaccessible surfaces is not greater than the limit specified in Point 8; c) for SCO-I where it is suspected that non-fixed contamination exists on inaccessible surfaces in excess of the values specified in Point 13(2)(a) of Annex 3 to this decree, measures shall be taken to ensure that the radioactive or fissile material is not released into the conveyance; and d) unpackaged fissile material meets the requirements of Point 17(e) of Annex 3 to this decree.
- 21.
LSA material and SCO, except as otherwise specified in Point 20, shall be packaged in accordance with the requirements of Table 1.
Table 1 Industrial package requirements for materials with low mass activity and surface contaminated items Radioactive contents Industrial package type Transport under exclusive use Transport not under exclusive use LSA-I Solid a)
Liquid Type IP-1 Type IP-1 Type IP-1 Type IP-2 LSA-II Solid Liquid and gas Type IP-2 Type IP-2 Type IP-2 Type IP-3 LSA-III Type IP-2 Type IP-3 SCO-I a)
Type IP-1 Type IP-1 SCO-II Type IP-2 Type IP-2 Legend:
a) Under the conditions specified in Point 20, LSA-I material and SCO-I may be transported unpackaged.
- 22.
The total activity in a single hold or compartment of an inland waterway craft, or in another conveyance, for carriage of LSA material or SCO in a Type IP-1, IP-2 or IP-3 package or unpackaged, shall not exceed the limits shown in Table 2.
Table 2 Activity limits for materials with low mass activity and surface contaminated items in industrial packages or transported as unpackaged Type of material or object Activity limit for conveyances other than inland waterway craft Activity limit for a hold or compartment of an inland waterway craft LSA-I Unlimited Unlimited LSA-II and LSA-III non-combustible solids Unlimited 100 A2 LSA-II and LSA-III combustible solids and all liquids and gases 100 A2 10 A2 SCO 100 A2 10 A2
- 8. DETERMINATION OF THE TRANSPORT INDEX
- 23.
The transport index for a package, freight container, overpack, unpackaged material in group LSA-I or unpackaged object in group SCO-I is a number derived in accordance with the following procedure:
a) multiply the maximum radiation level in units of millisieverts per hour (mSv/h) at a distance of 1 m from the external surfaces of the package, freight container, overpack or unpackaged LSA-I or SCO-I by 100. For uranium and thorium ores and their concentrates, the maximum radiation level at any point 1 m from the external surface of the load may alternatively be taken as:
- 2. 0.3 mSv/h for chemical concentrates of thorium;
- 3. 0.02 mSv/h for chemical concentrates of uranium, other than uranium hexafluoride; b) for tanks, freight containers and unpackaged LSA-I materials and unpackaged SCO-I items, the value determined in step (a) shall be multiplied by the appropriate factor from Table 3; and c) the value obtained in steps (a) and (b) shall be rounded up to the first decimal place, except for values of 0.05 or less, which may be considered to be zero.
Table 3 Multiplication factors for large loads Load dimensions a)
Multiplication factor load dimensions 1 m2 1
1 m2 < load dimensions 5 m2 2
5 m2 < load dimensions 20 m2 3
load dimensions > 20 m2 10 Legend:
a) Largest cross-sectional area of the load being measured.
- 24.
The transport index shall be determined, for:
a) a non-rigid overpack, as the sum of the TIs of packages it contains; and b) a freight container, overpack or conveyance, as either the sum of the TIs of all the packages it contains, or by direct measurement of radiation level.
- 9. DETERMINATION OF THE CRITICALITY SAFETY INDEX FOR FREIGHT CONTAINERS, OVERPACKS, AND CONSIGNMENTS
- 25.
The critical safety index for a freight container, overpack, consignment, or conveyance shall be determined as the sum of the individual critical safety indexes of all the packages it contains.
- 10. LIMITS FOR THE TRANSPORT INDEX, CRITICALITY SAFETY INDEX, AND RADIATION LEVELS FOR PACKAGES AND OVERPACKS
- 26.
- 1. Except for consignments under exclusive use, the transport index of any package or overpack shall not exceed 10.
- 2. The critical safety index of any package or overpack shall not exceed 50.
- 27.
The radiation level at any point on the external surface of a package or overpack shall not exceed 2 Sv/h. The requirement of the introductory sentence does not apply to packages or overpacks transported under exclusive use by rail or by road in accordance with the conditions specified in Point 73(a), or under exclusive use and special arrangement by vessel or by air in accordance with the conditions specified in Point 75 or 79.
- 28.
The radiation level at any point on the external surface of a package or overpack transported under exclusive use shall not exceed 10 Sv/h.
- 11. CATEGORY
- 29.
Packages, freight containers and overpacks shall be placed in either category I-WHITE, II-YELLOW, or III-YELLOW pursuant to the requirements specified in Table 4 and pursuant to the requirements of (a) to (d):
a) if the transport index satisfies the condition for one category but the surface radiation level satisfies the condition for a different category, the package, freight container or overpack shall be assigned to the higher category; category I-WHITE is regarded as the lowest category; b) the TI shall be determined via the procedures specified in Points 23 and 24; c) except for Point 30, a package transported under special arrangements is placed in category III-YELLOW; and d) except for Point 30, an overpack containing packages transported under special arrangement is placed in category III-YELLOW.
Table 4 Categories of packages and overpacks Conditions Transport index Maximum radiation level at any point on the external surface Category 0 a) at most 0.0005 mSv/h I-WHITE more than 0, but not more than 1 a) more than 0.005 mSv/h, but not more than 0.5 mSv/h II-YELLOW more than 1, but not more than 10 more than 0.5 mSv/h, but not more than 2 mSv/h III-YELLOW more than 10 more than 2 mSv/h, but not more than 10 mSv/h III-YELLOW b)
Legend:
a) If the measured transport index is not greater than 0.05, the TI value may be considered to be zero in accordance with Point 23(c).
b) Shall also be transported under exclusive use except for freight containers, see Table 6.
- 12. MARKING, LABELLING, AND PLACARDING
- 30.
- 1. A package or overpack shall be assigned a UN number and named pursuant to Table 1 of Annex 3 to this decree.
- 2. In cases of international transport of packages requiring competent authority approval of design or shipment, for which packaging type approval or transport authorisation by the relevant authority of the country the shipment concerns, the UN number, proper shipping name, categorisation, labelling and marking shall be in accordance with the decision of the relevant authority of the country of origin of the design.
12.1. Marking
- 31.
- 1. A package shall be legibly and durably marked on the outside of the packaging with an identification of either the consignor or consignee, or both.
- 2. If the markings of all the packages within the overpack are not clearly visible, the outside of the overpack shall be legibly and durably marked with an identification of either the consignor or consignee, or both.
- 32.
- 1. A package shall be legibly and durably marked on the outside with the UN marking as specified in Table 5.
- 2. If the markings of all the packages within the overpack are not clearly visible, the overpack shall be legibly and durably marked with the word OVERPACK and the UN marking as specified in Table 5.
Table 5 UN markings for packages and overpacks Item UN marking a)
Package (other than a package exception)
UN
- number, preceded by the letters 'UN',and its proper shipping name Package exception UN number, preceded by the letters UN Overpack (other than an overpack UN number, preceded by the letters UN
containing only package exceptions) for each applicable UN number in the overpack, followed by the proper shipping name in the case of a non-excepted package Overpack containing only package exceptions UN number, preceded by the letters UN for each applicable UN number in the overpack Legend:
a)for a list of UN numbers and proper shipping names, see Table 1 of Annex 3 to this decree.
- 33.
A package of gross mass exceeding 50 kg shall have its permissible gross mass legibly and durably marked on the external surface.
- 34.
A package that conforms to:
a) an IP-1, IP-2, or IP-3 design shall be legibly and durably marked on the outside of the packaging with TYPE IP-1, TYPE IP-2 or TYPE IP-3, as appropriate; b) a Type A package design shall be legibly and durably marked on the outside of the packaging with TYPE A; c) an IP-2, IP-3, or a Type A package design shall be legibly and durably marked on the outside of the packaging with the international vehicle registration code (VRI code) of the country of origin of design and either the name of the manufacturer or identification of the packaging specified by the Office.
- 35.
The packaging manufactured pursuant to a type approval decision shall be legibly and durably marked with the following on the outside surface:
a) the type identification mark in accordance with a type approval decision issued by the Office; b) a serial number to uniquely identify each packaging of approved type; and c) for Type B(U), B(M), and C packages, TYPE B(U), TYPE B(M), and TYPE C, as applicable.
- 36.
A package that conforms to a Type B(U), Type B(M), and Type C design shall have the outside of its packaging marked by embossing, stamping or other means resistant to the effects of fire and water with the trefoil symbol. Table 1 contains an example of the trefoil symbol.
- 37.
LSA-I material or an SCO-I object that is contained in receptacles or wrapping materials and is transported under exclusive use pursuant to Point 20 shall be marked on the outer surface of these receptacles or wrapping materials with RADIOACTIVE LSA-I or RADIOACTIVE SCO-I, as appropriate.
Figure 1 Basic trefoil symbol with proportions based on a central circle of radius X. The minimum permitted size of X is 4 mm.
12.2. Labelling
- 38.
- 1. Except for Point 43, a package, overpack, and freight container shall bear labels conforming to the models in:
a) Figure 2 for the category I-WHITE; b) Figure 3 for the category II-YELLOW; c) Figure 4 for the category III-YELLOW.
- 2. Except for an exempt fissile material pursuant to Point 17 of Annex 3 to this decree, a package, overpack, and freight container containing fissile material shall also bear labels conforming to the model in Figure 5.
- 3. Other labels that are not related to the contents shall be removed or covered.
- 39.
- 1. Labels conforming to the models in Figures 2, 3 or 4 shall be affixed to two opposite sides of the outside of a package or overpack or on the outside of all four sides of a freight container or tank.
- 2. The label conforming to the model in Figure 5 shall be affixed adjacent to the labels specified in (1).
- 3. The labels shall not cover the markings specified in Points 31 to 36.
Figure 2 Category I-WHITE label. The background colour of the label shall be white, the colour of the trefoil and the printing shall be black, and the colour of the category bar shall be red.
12.3. Labelling for radioactive contents
- 40.
Each label conforming to the models in Figures 2, 3 and 4 shall be completed with the following information on a) content:
- 1. except for LSA-I material, the names of the radionuclides pursuant to Table 2 of Annex 3 to this decree, using the symbols prescribed therein.
For mixtures of radionuclides, the most restrictive nuclides must be listed to the extent the space on the line permits. For materials in an LSA group or objects in an SCO group, the names of the radionuclides shall be followed by LSA-II, LSA-III, SCO-I, or SCO-II as applicable; and
- 2. for LSA-I material, the term LSA-I shall be filled in.
b) activity: the maximum activity of the radioactive contents during transport expressed in units of becquerels with the appropriate SI prefix symbol. For fissile material, the total mass of fissile nuclides in units of grams, or multiples thereof, may be used in place of activity. For an overpack or freight container, the contents and activity entries on the label shall bear the information in
accordance with Letter (a) and (b). Labels for an overpack or freight container containing a mixed load of packages containing different radionuclides, entries in the content and activity rows may read: See Transport Documents; and c) transport index: the number determined in accordance with Points 23 and 24; no transport index entry is required for Category I-WHITE.
12.4. Labelling for criticality safety
- 41.
Each label conforming to the model in Figure 5 shall be completed with the critical safety index as stated in the transport authorisation or packaging type approval decision issued by the Office, in a decision issued by the relevant authority of the country of origin of the packaging or the country of origin of carriage in the case of international carriage, or in accordance with the requirements of Point 74 or 75 of Part I to Annex 1 to this decree.
- 42.
For an overpack or freight container, the label conforming to the model in Figure 5 shall bear the sum of the critical safety indexes of all the packages contained therein.
12.5. Placarding
- 43.
A large freight container carrying packages other than package exceptions, and a tank shall bear placards that conform to the model given in Figure 6. The placards shall be affixed in a vertical orientation to the front, each side wall and to the rear wall of the large freight container or tank. Other labels that do not relate to the contents shall be removed. Instead of using both labels and placards, it is possible to use only enlarged labels as shown in Figures 2, 3, 4, or 5, enlarged so they have the minimum dimensions as specified in the model in Figure 6.
Figure 3 Category II-YELLOW label. The background colour of the upper half of the label shall be yellow and the lower half white, the colour of the trefoil and the printing shall be black, and the colour of the category bars shall be red.
- 44.
- 1. Where a consignment of unpackaged LSA-I or SCO-I being shipped in a freight container or tank is or a consignment of packaged radioactive material being shipped under exclusive use can be marked with a single UN number, the UN number for the consignment shall be displayed in black digits not less than 65 mm high:
a) in the lower half of the placard shown in Figure 6 on a white background; or b) on a placard pursuant to the model shown in Figure 7.
- 2. When marking pursuant to (1)(b), the subsidiary placard pursuant to the model in Figure 7 shall be affixed immediately adjacent to the main placard pursuant to the model in Figure 6 on all four sides of the freight container or tank.
Figure 4 Category III-YELLOW label. The background colour of the upper half of the label shall be yellow and the lower half white, the colour of the trefoil and the printing shall be black, and the colour of the category bars shall be red.
- 13. THE CARRIER'S OBLIGATIONS
- 45.
Unless otherwise specified in this decree, no radioactive or fissile material shall be provided for transport unless it is properly marked, labelled, placarded, described in transport documents, includes a declaration of the carrier or confirmation of freight container or conveyance loading, as applicable, and is in every aspect suitable for transport.
Figure 5 Criticality safety index label. The background colour of the label shall be white, the colour of the printing shall be black.
13.1. Particulars of consignment description in the carriage document
- 46.
- 1. In the transport documents accompanying a consignment, the carrier shall include identification of the consignor and consignee, in the case of a natural person their name(s), surname and addresses, and in the case of a corporate entity its name and registered address, and the relevant information in the following order:
a) the UN number assigned to the radioactive or fissile material, preceded by the letters UN; b) the proper shipping name assigned to the radioactive or fissile material; c) UN class number 7; d) subsidiary hazard class numbers corresponding to the label numbers required if the radioactive or fissile material is also classified in other classes or subclasses of dangerous goods; the subsidiary hazard class numbers shall follow the primary hazard class number in brackets; e) the name or symbol of each radionuclide or, for mixtures of radionuclides, an appropriate general description or a list of the most restrictive nuclides; f) a description of the physical and chemical form of the radioactive or fissile material, or information that the material is special form radioactive material or low dispersible radioactive material; the chemical form may be stated as a chemical formula;
g) the maximum activity of the radioactive contents during transport expressed in units of becquerels with the appropriate SI prefix symbol. In place of activity, the following may be provided:
- 1. for fissile material, total mass in grams or multiples thereof; and
- 2. for a mixture of fissile radionuclides, the mass of each fissile nuclide present in grams or multiples thereof; h) the category of the package, i.e. I-white, II-yellow, or III-yellow; i) the transport index for categories II-YELLOW and III-YELLOW; j) for fissile material:
- 1. shipped under one of the exceptions in Point 17(a) to (f) of Annex 3 to this decree, a reference to this provision;
- 2. shipped under one of the exceptions in Point 17(c) to (e) of Annex 3 to this decree, the total mass of fissile radionuclides;
- 3. shipped in a package with the use of one of the provisions of Point 74(a) to (c) of Annex 1 to this decree, a reference to this provision; and
- 4. the criticality safety index; k) the identification mark of a type approval or transport authorisation decision issued by the Office, and in the case of international transport, also the identification mark of the authorisation of the relevant authority of the country the transport concerns that is required for the consignment; l) for a consignment shipped under exclusive use, the statement EXCLUSIVE USE SHIPMENT; and m) for a consignment of LSA-II, LSA-III, SCO-I and SCO-II, the total activity of the consignment as a multiple of A2; for a consignment of radioactive or fissile material for which the A2 value is unlimited, the multiple of A2 is equal to zero.
- 2. For a consignment of more than one package, the information pursuant to (1)(a) to (k) shall be given for each package. For packages in an overpack, freight container, or conveyance, a detailed statement of the contents of a package within the overpack, freight container or conveyance and, where appropriate, of each overpack, freight container or conveyance shall be included. If packages are to be removed from the overpack, freight container or conveyance at a point of intermediate unloading, appropriate transport documents for these packages shall be made available.
Figure 6 Placard Except for Point 71, minimum dimensions shall be as shown; when different dimensions are used, the relative proportions shall be maintained. The numeral 7 shall not be less than 25 mm high. The background colour of the upper half of the label shall be yellow and the lower half white, the colour of the trefoil and the printing shall be black. The use of the word RADIOACTIVE in the bottom half is optional, to allow the alternative use of this placard to display the appropriate UN number for the consignment.
Figure 7 Placard for separate display of UN number. The background colour of the placard shall be orange and the border and UN number shall be black. The symbol denotes the space in which the appropriate UN number for radioactive material is to be displayed, as specified in Table 1 of Annex 3 to this decree.
13.2. Consignors declaration
- 47.
The consignor shall include the following in the transport documents: I hereby declare that the contents of this consignment are fully and accurately described above by the proper shipping name and are classified, packaged, marked and labelled/placarded, and are in all respects in proper condition for transport pursuant to applicable international agreements and the legislation of the Czech Republic, and in the case of international transport, also pursuant to the legislation of the state that the carriage concerns.
- 48.
The consignor need not provide a declaration pursuant to Point 47 for that part of the transport covered by the obligation to provide a declaration with similar content stipulated by an international convention by which the Czech Republic is bound.
- 49.
The declaration pursuant to Point 47 shall be signed and dated by the consignor.
- 50.
Documentation for the transport of dangerous goods may be provided to the carrier in writing, or with his/her approval, electronically.
- 51.
During marine transport of radioactive or fissile material placed or loaded into a freight container or on a vehicle, those responsible for loading the container or vehicle shall provide a container/vehicle packing certificate specifying the container/vehicle identification number and certifying that the operation has been carried out in accordance with international requirements.
- 52.
The information required in the transport documents and the container/vehicle packing certificate may be incorporated into a single document or attached one to each other. If the information is incorporated into a single document, the document shall include a signed declaration stating:
I hereby declare that the packing and loading of radioactive or fissile material into the container/vehicle has been carried out in accordance with the applicable provisions.
- 53.
The declaration pursuant to Point 52 shall be dated and the person signing it shall be identified in the document. The declaration shall be made on the transport document that contains the information specified in Point 46.
13.3. Information for carriers
- 54.
The consignor shall provide in the transport documents instructions regarding actions that must be taken by the carrier. The instructions shall be in the languages required by the carrier, the Office and, in the case of international transport, also the appropriate authority of the country the transport concerns. The instructions include at least the following:
a) supplementary requirements for loading, stowage, carriage, handling and unloading of the package, overpack, or freight container, including any special stowage provisions for the safe dissipation of heat, or instructions that no such requirements are necessary; b) information regarding restrictions on the mode of transport or conveyance and any necessary routing instructions; c) instructions regarding emergency arrangements for the given consignment.
- 55.
The consignor shall retain a copy of each of the transport documents containing the information specified in Points 46, 47, 51, 52 and 54 for at least three months.
When the documents are kept electronically, the consignor shall be able to convert them into paper form.
- 56.
The type approval decision and transport authorisation need not accompany the consignment. However, the consignor shall make them available to the carrier(s) before loading and unloading.
13.4. Notification of administrative authorities
- 57.
Before the first shipment of any package requiring type approval or authorisation for transport, the consignor shall ensure that copies of the type approval or authorisation for transport documents have been submitted to the competent authority of the country that the transport concerns.
- 58.
- 1. The consignor shall notify the Office, and in the case of international transport, also the competent authority of the country that the transport concerns, regarding transport:
a) of Type C packages containing radioactive or fissile material with activity greater than 3.103 A1 or 3.103 A2 or 1 000 TBq, whichever is less; b) of Type B(U) packages containing radioactive or fissile material with activity greater than 3.103 A1 or 3.103 A2 or 1 000 TBq, whichever is less; c) of Type B(M) packages; and d) under special arrangement.
- 2. The Office and other competent authorities must receive notification pursuant to (1) at least seven days prior to the start of transport.
- 59.
The consignment notification shall include:
a) information enabling the identification of the package or packages, including all identification marks in accordance with a type approval decision issued by the Office, and in the case of international transport, also identification marks for the authorisation of the competent authority of the country that the transport concerns; b) information on the date of shipment, the expected date of arrival, and the proposed route; c) the names of the radioactive or fissile material or radionuclides; d) a description of the physical and chemical form of the radioactive or fissile material, or information that the material is special form radioactive material or low dispersible radioactive material; and
e) information regarding the maximum activity of the radioactive contents during transport expressed in units of becquerels with the appropriate SI prefix symbol. In place of activity, the following may be provided:
- 1. for fissile material, total mass in grams or multiples thereof; and
- 2. for a mixture of fissile radionuclides, the mass of each fissile nuclide present in grams or multiples thereof;
- 60.
The consignor is not required to send a separate notification pursuant to Points 58 and 59 if the required information has been included in the transport approval application.
13.5. Documents and operating rules the consignor must have available
- 61.
The consignor shall have available a copy of a decision of the decision of the Office regarding transport, and in the case of international transport, also a copy of a decision of the competent authority of the country that the transport concerns, a copy of the instructions with regard to the proper closing of the package, and preparations for shipment, before making any shipment.
- 14. TRANSPORT AND STORAGE IN TRANSIT 14.1. Segregation during transport and storage in transit
- 62.
A package, overpack, or freight containers containing radioactive or fissile material and unpackaged material shall be segregated during transport and during storage in transit from:
a) workers in regularly occupied working areas by distances calculated using a maximum permissible effective dose criterion of 5 mSv in a year and conservative model parameters; b) members of the public in areas where the public has regular access by distances calculated using a maximum permissible effective dose criterion of 1 mSv in a year and conservative model parameters; c) undeveloped photographic film by distances calculated using a maximum dose criterion of 0.1 mGy due to the transport of one consignment of radioactive or fissile material on this film; and d) other dangerous goods in accordance with Point 6.
- 63.
Category II-YELLOW or III-YELLOW packages or overpacks shall not be carried in compartments occupied by passengers, except those exclusively reserved for couriers specially authorised to accompany such packages or overpacks.
14.2. Stowage on or in the conveyance during transport and storage in transit
- 64.
During transport and storage, the consignment shall be securely stowed so that it cannot move, turn over or fall.
- 65.
- 1. A package or overpack may be carried or stored among other packaged cargo without any special stowage provisions, if:
a) its average surface heat flux does not exceed 15 W/m2, and b) the immediate surrounding cargo is packaged in a manner other than sacks or bags.
- 2. The provisions of (1) shall not be applied if the Office, and in the case of international transport, also the competent authority of the country that the transport concerns, specifies otherwise in a type approval decision.
- 66.
For the loading of freight containers and accumulation of packages, overpacks and freight containers, the following applies:
a) except under the condition of exclusive use, and for consignments of LSA-I material, the total number of packages, overpacks, and freight containers on or in a single conveyance shall not exceed the values shown in Table 6; b) the radiation level under routine conditions of transport shall not exceed 2 mSv/h at any point on, and 0.1 mSv/h at 2 m from, the external surface of the conveyance; for consignments transported under exclusive use by road or rail, radiation limits around the vehicle are stipulated in Points 73(b) and (c); and c) the sum of the critical safety indexes s in a freight container and on or in a conveyance shall not exceed the values shown in Table 7.
Table 6 Transport index limits for freight containers and conveyances not under exclusive use Type of freight container or conveyance Limit on total sum of transport indexes in a freight container or aboard a conveyance Freight container small Large 50 50 Vehicle 50 Aircraft passenger Cargo 50 200 Inland waterway vessel 50 Seagoing vessel a)
(1) Hold, compartment or defined deck area:
packages, overpacks or small freight containers large freight containers (2) Total vessel:
packages, overpacks or small freight containers large freight containers 50 200 200 unlimited Legend:
a) Packages or overpacks on vehicles that meet the requirements of Point 73 may be transported by vessels provided that they are not removed from the vehicle at any time while it is on board the vessel.
- 67.
Packages or overpacks with a transport index greater than 10 and consignments with a criticality safety index greater than 50 shall be transported only under exclusive use.
14.3. Additional transport and storage requirements during transport of fissile material
- 68.
The number total sum of the criticality safety indexes in a group of packages, overpacks or freight containers containing fissile material stored in transit shall not exceed 50 in a storage area. The distance between individual groups pursuant to the first sentence shall be at least 6 m.
Table 7 Critical safety index limits for freight containers and conveyances containing fissile material Type of freight container or conveyance Limit on total sum of criticality safety indexes in a freight container or aboard a conveyance Other transport Transport under exclusive use Freight container small Large 50 50 100 Vehicle 50 100 Aircraft passenger Cargo 50 50 100 Inland waterway vessel 50 100 Seagoing vessel a):
(1) Hold, compartment or defined deck area packages, overpacks or small freight containers large freight containers (2) Total seagoing vessel packages, overpacks or small freight containers large freight containers 50 50 200 b) unlimited b) 100 100 200 c) unlimited c)
Legend:
a) Packages or overpacks on a vehicle that meets the requirements of Point 73, may be transported by vessel provided that they are not removed from the vehicle at any time while on board the vessel. In this case the entries under the heading Under exclusive use apply.
b) The consignment shall be so handled and stowed that the total sum of critical safety indexes in any group does not exceed 50, and that each group is handled and stowed so that the groups are separated from each other by at least 6 m.
c) The consignment shall be so handled and stowed that the total sum of critical safety indexes in any group does not exceed 100, and that each group is handled and stowed so that the groups are separated from each other by at least 6 m. The intervening space between groups may be occupied by other cargo in accordance with Point 6.
- 69.
Where the total sum of the criticality safety indexes on board a conveyance or in a freight container exceeds 50, storage shall be such as to maintain a spacing of at least 6 m from other groups of packages, overpacks or freight containers containing fissile material or other conveyances carrying radioactive material.
- 70.
Additional requirements relating to transport of fissile material classified pursuant to one of Point 17(a) to (f) of Annex 3 to this decree are as follows:
a) for a consignment, one in Point 17(a) to (f) of Annex 3 to this decree may be used; b) a consignment may carry only one exempted fissile material in packages pursuant to Point 17(f) of Annex 3 to this decree, unless specified otherwise by the Office, and in the case of international transport, also the competent authority of the country that the transport concerns, in the authorisation for transport;
c) exempted fissile material in packages pursuant to Point 17(c) of Annex 3 to this decree shall be transported in a consignment containing at most 45 g of fissile radionuclides; d) exempted fissile material in packages pursuant to Point 17(d) of Annex 3 to this decree shall be transported in a consignment containing at most 15 g of fissile radionuclides; and e) unpackaged and packaged exempted fissile material in packages pursuant to Point 17(e) of Annex 3 to this decree shall be transported in a consignment containing at most 45 g of fissile radionuclides, and must be transported under exclusive use.
14.4. Additional requirements relating to transport by rail and road
- 71.
- 1. Rail and road vehicles carrying packages, overpacks or freight containers labelled with any of the labels shown in Figure 2, 3, 4 or 5 or carrying consignments under exclusive use shall display the placards shown in Figure 6:
a) on the two external lateral walls in the case of a rail vehicle; or b) on the two external lateral walls and the rear wall in the case of a road vehicle.
- 2. In the case of a vehicle without sides, the placards may be affixed directly on the chassis carrying the cargo provided that they are readily visible; in the case of large-volume tanks or freight containers, the placards shall be placed only on them. In the case of vehicles which have insufficient area to allow the fixing of larger placards with dimensions as described in Figure 6, the dimensions the sides of the placard may by reduced to 100 mm. Other labels that do not relate to the radioactive contents of the vehicle shall be removed.
- 72.
- 1. Where a consignment of unpackaged LSA-I or SCO-I being on or in a vehicle or a consignment of packaged radioactive or fissile material being shipped under exclusive use on or in a vehicle can be marked with a single UN number, the UN number for the consignment shall be displayed in black digits not less than 65 mm high:
a) on a white background in the lower half of the placard shown in Figure 6; or b) on a placard pursuant to the model shown in Figure 7.
- 2. When marking pursuant to (1)(b), the placard pursuant to the model in Figure 7 shall be affixed immediately adjacent to the main placard pursuant to the model in Figure 6 on the two external lateral walls in the case of a rail vehicle or on the two external lateral walls and the rear wall in the case of a road vehicle.
- 73.
For consignments under exclusive use, the radiation level shall not exceed:
a) 10 mSv/h at any point on the external surface of any package or overpack; the radiation level shall however not exceed 2 mSv/h in the following situations:
- 1. the vehicle is not equipped with an enclosure that during routine conditions of transport prevents unauthorised persons from accessing the interior of the enclosure;
- 2. provisions are not made to secure the package or overpack so that its position within the vehicle remains fixed during routine conditions of transport; and
- 3. there is loading or unloading during the shipment; b) 2 mSv/h at any point:
- 1. on the outer surfaces of an enclosed vehicle, including roof and floor areas; or
- 2. on a vertical plane projected from the outer edge of an open vehicle, the surface of the load and the lower external surface of the vehicle; and c) 0.1 mSv/h at any point 2 m from:
- 1. the external surface of a vertical plane of an enclosed vehicle; or
- 2. the vertical plane that intersects the external edge of an open vehicle.
- 74.
In the case of road vehicles, no persons other than the driver and assistants shall be permitted in vehicles carrying packages, overpacks or freight containers bearing category II-YELLOW or III-YELLOW labels.
14.5. Additional requirements relating to transport by vessels
- 75.
Packages or overpacks having a surface radiation level greater than 2 mSv/h shall not be transported by vessel. The provision of the first sentence does not apply to packages or overpacks:
a) transported under exclusive use in accordance with Table 6, column Transport under exclusive use or on a vehicle that meets the requirements of Point 73, provided that they are not unloaded from the vehicle during its presence on board the vessel; or b) transported under special arrangement.
- 76.
The transport of consignments by means of a special use vessel is exempt from the requirements specified in Point 66 if:
a) a radiation protection programme for the shipment has been drawn up and has been approved by the Office or a competent authority of the flag state of the vessel, if the operator of the special use vessel is a foreign entity, and also, if requested, by the competent authority at each port of call; b) stowage arrangements shall be predetermined for the entire route including any consignments to be loaded at ports of call en route; c) the loading, carriage and unloading of the consignments shall be supervised by persons qualified in the transport of radioactive and fissile material.
14.6. Additional requirements relating to air transport
- 77.
Type B(M) packages and consignments under exclusive use shall not be transported on passenger aircraft.
- 78.
Vented Type B(M) packages, packages that require external cooling by an auxiliary cooling system, packages subject to operational controls during transport, and packages containing liquid pyrophoric material shall not be transported by air.
- 79.
Packages or overpacks having a surface radiation level greater than 2 mSv/h shall not be transported by aircraft. The provision of the first sentence does not apply to packages or overpacks transported under special arrangements.
14.7. Transport by post
- 80.
The transport of radioactive or fissile material via post is prohibited in the Czech Republic.
- 15. OTHER REQUIREMENTS
- 81.
Customs inspection of the radioactive contents of a package shall be performed in a location with facilities required to limit and monitor radiation exposure, and in the presence of qualified individuals.
- 82.
A package opened upon the instructions of the Customs Office must be returned to its original condition prior to being handed over for further transport.
- 83.
A package that cannot be delivered must be placed in a safe location. The Office must be informed of this fact immediately.
- 16. CARRIAGE DOCUMENTS KEPT BY AND AVAILABLE FROM THE CARRIER
- 84.
A carrier shall not accept a consignment for transport unless copies of the transport documents, other documents, or information have been handed over, or provided electronically.
- 85.
The information applicable to the consignment shall accompany the consignment to final destination and must be given to the consignee upon delivery.
- 86.
Information applicable to the consignment given to the carrier in electronic form shall be available to the carrier at all times during transport to the final destination, and it must be possible convert it into paper form at any time.
- 87.
The carrier shall retain a copy of the transport document and additional information and documentation pursuant to this decree for at least three months.
- 88.
When the documents pursuant to this decree are kept electronically, the consignor shall be able to convert them into paper form.
Annex 5 to Decree No SAMPLES OF STANDARD DOCUMENTS General Comments Parts A-1 to A-6 are filled in for shipment of radioactive waste Parts B-1 to B-6 are filled in for shipment of spent fuel (including spent fuel intended for final deposit, which is therefore classified as waste).
Part A-1 or B-1 (application for shipment authorisation): filled in by the applicant, which depending on the type of shipment, is a holder in the case of shipment between Member States (Type MM) or export from the Community to third countries (type ME);
a recipient in the case of import to the Community from a third country (Type IM);
a person responsible for shipment in a Member State through which radioactive waste or spent fuel enters the Community in the case of transit through the Community (Type TT).
Part A-2 or B-2 (acknowledgement of receipt): to be filled in by the competent authorities, which depending on the type of shipment, are the competent authorities of the country of origin in the case of a Type MM or ME shipment; the destination country in the case of Type IM shipment; the country where the shipment first enters the Community in the case of a Type TT shipment, and all competent authorities of any transit Member States.
Part A-3 or B-3 (consent or refusal): to be filled in by all relevant competent authorities.
Part A-4a/A-4b or B-4a/B-4b (consent or refusal of transport): to be filled in by the competent authority responsible for issuing the authorisation, which depending on the type of shipment, is the competent authority of the country of origin in the case of Type MM and ME shipment; the destination Member State in the case of type IM shipment; or the first Member State where the shipment enters the Community, in the case of a Type TT shipment.
Part A-5 or B-5 (a description of the consignment/list of packagings): filled in by the applicant stipulated in Part A-1 or B-1.
Part A-6 or B-6 (acknowledgement of receipt of the shipment): to be filled in by the recipient (for shipment Type MM and IM) or the holder (for a Type ME shipment), or the person responsible for shipment (in the case of a Type TT shipment).
- 100 -
- 101 -
Annex 6 to Decree No REQUIREMENTS FOR CALCULATION OF ACTIVITY VALUES FOR EXCEPTION OF A PACKAGE FOR TRANSPORT OF RADIOACTIVE OR FISSILE MATERIAL IN INSTRUMENTS OR PRODUCTS Principles and methods for calculation of activity values for exception of a package for transport of radioactive or fissile material in instruments or products are stipulated in IAEA document Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards, General Safety Requirements, IAEA Safety Standards Series No. GSR, Part 3, International Atomic Energy Agency, Vienna, 2014.