Forwards Revised Draft Statement of Work Proposed for Task Order 009, Continuing Exercise Support to NRC Operations Ctr,Electronic Transmission of Plant Parameters During Exercises, for Contract NRC-05-86-170
ML20237D668
Person / Time
Site: Zion, 05000000
Issue date: 03/04/1987
From: Schultz D
COMEX CORP.
To: Priebe R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
Shared Package
ML20235G519 List: ... further results
References
CON-NRC-05-86-170, CON-NRC-5-86-170, FOIA-87-737 NUDOCS 8712240116
Download: ML20237D668 (4)


Text

%.g [ d l[ G N5 Y i ' 4 k h jji k.3 Q 2 L ;s k l @ h M ] g h g; c h;b i gz Q lj d 3 Q M ~

l

= =. _

=

_

~

=

=

a::===r-EEi!liF EEE

==-

M CORPORATION I

f
j 4 March 1987

]

Mr. Ray.Priebe, Chief 1

Section B s

Incident Response Branch

}

Office of Inspection and Enforcement j'

U.

S. Nuclear Regulatory Commission l

Washington, D. C.

20555

-l

)j

Subject:

Draft Statement of Work, Revised, for Task Order $9, q

Contract NRC-05-86-170 i

]

Dear Mr. Priebe:

(1 Enclosed is the revised draft Statement of Work proposed for Task j

Order #9, " Continuing Exercise Support to NRC Operations Center, 1.

Electronic Transmission of Plant Parameters During Exercises".

3 ((D This revised statement incorporates ~NRC staff comments on the 1

original submitted for consideration on 20 February 1987.

.4j Mr. Bethke and I will be in Bethesda the week of 9' March 1987 to L1 discuss this tasking and others, as you may desire.

If you have f,

any questions before then, feel free to contact-me through 206 j

786-8388, or at 206 692-0153.

.a y

Respectfully, l

David H.

Schultz Vice President

}

hj j

Id I

'7 li si i

a

.d j

'I d

1419 Sweetwater Loop P.O. Box 1735 17016 Dace Drive f.l Olympla, Washington 98502 Lake Oswego, Oregon 97034 Rockville, Maryland 20855 206/786-8388 301/921 0494 1

8712240116 871210 l

]

PDR-FOIA 1

q SHOLLYB7-737 PDR 8

d,a i L

%$1UdhhmdMik;ducM[." ' aNh&219;MEESMd.2$$2s.g;;i. l 1

1 ENCLOSURE

?

a

'l Task Order No.OO9

-()

Title:

Continuing Exercise Support to NRC Operations Center, Electronic Transmission of Plant Parameters During Exercises I

A.

Description l

This Task Order is being issued under work area 1 of Contract NRC-05-86-170. A requirement has been identified to provide for electronic transmission of plant parameters, including if j

!j possible, thermal-hydraulic, radiological, and meteorological data, during ' selected Full-scale exercises involving the NRC l

Operations Center.

The first opportunity involving j

participation by NRC incident response personnel is the second j

Federal Field Exercise (FFE-2) being conducted in conjunction with the full-scale exercise at Zion Nuclear Power Station 23-I 25 June 1987.

f B. Statemen,t of Work q

a L]i Three phases of the work have been identified -

l

]

1) investigative 1
2) implementation I
3) exercise performance K~#,

The following tasks have been identified in this effort:

3 d)

1) Identify the parameters that are suitable for transmission from Zion station to NRC Headquarters during the exercise.

The parameters should be as close to the list of parameters for ERDS as is possible.

Coordinate this list with NRC and Commonwealth Edison Company (CECO).

Parameters will be selected from those available on only one CECO computer I

/

system.

2) Obtain from Zion station personnel all necessary plant E

information to permit conversion and interpretation of I

transmitted plant parameters, and provide this information

<i to NRC incident response personnel in useable note-pad s

format.

Example: the plant vent effluent activity may be

?j in " cpm"; the contractor should provide all conversion data j

and plant procedures to permit calculation of a release q

rate in curies per second if desired by Operations Center

,j i

personnel.

No computer-based work (other than text g

editing) will be required.

l

3) Provide assistance to CECO personnel in extracting data f

1 from the FFE-2 scenario; prepare the data for transmission i

from CECO to the Ops Center.

Data shall be transmitted at I

!(

one minute intervals during the scenario for days 1 and 2.

j Q, COMEXl 1.i

._G

' ) < ' w :

"2 ' L u t[d h w df.il: x n & s s i d s t d.yu is k u n g k d L$G4 %

.i.

j Work shall icelude:

~

N

'I Reaching agreement with CECO regarding data transmission protocol and data formats.

~

Preparation of test data that can be used for implementation debugging (including tests of data transmission) without concern for its secrecy.

i l

Reaching agreement with CECO regarding access to its l

data transmission facilities from time to time for

]

implementation debugging.

1 Li Prior to the FFE, a demonstration of data transmission and

]

an FFE Dry-run exercise will also be conducted.

The date for j

the demonstration of data transmission will be mutually agreed by the contractor, CECO, and NRC.

4) Investigate, recommend, and implement a suitable h.j hardware / software environment for the NRC Headquarters-located functions of this system.

These functions shall include:

i!

Receiving data transmissions f rom CECO.

j

]

Storing data in a database or file system which can supply data to the display functions.

Displaying data to users concurrently at three 1coations j

in the Operations Center, with printing capability at

p#

two of them; and, in addition, at the cognizant NRC

.g Regional Office, with printing. capability.

j The display functions shall include:

?

Columnar screen displays of parameters vs time, in pre-defined, single-screenful groupings, with the most recent column on the right.

These displays will be updated with newly received data automatically (without user input).

The only user control will be the 1

selection of the parameter grouping to be displayed.

j Users will not be able to select the time range to be L.)

displayed.

.j' j

Printout showing all data received in each minute update, with most recent data on the bottom.

j X-Y plotting of one or two parameters (on Y-axis) vs 1

time (on I-axis).

Users will specify the parameter (s) and the time range.

Printing of X-Y plots generated by. users.

Printing 3

using either characters or dot graphics is acceptable.

2

,1 v

2 COMEXl e

n

U.n2.w Lw1w

< m.hM :;.uzid:endi.;2.w:u.awu.. amu.ukas.a: ada; sus;Guxhkaa

?!

i i

5) The contractor shall provido support service during a

'i demonstration of data transmission prior to the FFE Dry-run.

The contractor shall also provide support

'l.( )

service during the FFE Dry-run and the FFE exercise at

)j both the site and the NRC Operations Center to ensure operability of the system.

1 ej

6) Training shall be provided for up to six users.

The

]

O trainees can be assumed to have had some work-related i

experience in using IBM-compatible Personal Computers.

The l

training shall be initiated no later than one week prior to i

the FFE Dry-run and continue until the FFE exercise.

)

i]

Suitable user documentation shall be provided so that the trained users can use the display functions of the system without further contractor assistance.

}

7) Software and system management procedures utilized during d

the FFE-2 shall be documented so that an experienced J

computer specialist could re-establish the capabilities of y

this system for a subsequent NRC exercise.

'1 C. Period of Performance

')

The task shall commence upon award and be completed by 15 August 1987.

3 I

D. Reporting

.! ih#

j Monthly report requirements shall be in accordance with Paragraph F.1.1 of the basic contract.

i

j E.

Estimated Level of Effort: 100 Man-days

?.j F. Government Furnished Equipment

]Li NRC will provide most equipment and software products required for development, training, demonstrations, and live j

usage.

The contractor is authorized to expend funds not to exceed $1,000.00 for "off-the-shelf" software, and o,

d miscellaneous, small-cost, hardware components, e.g.,

cables i

and connectors.